ML Accessories VFRSGICW, VFRDGICB, VFRSGICB, VFRSGICC, VFRSGICCBR, VFRSHGICCBR, VFRSHGICW User manual

  • Hello! I am an AI chatbot trained to assist you with the ML Accessories VFRSGICW User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION & MAINTENANCE MANUAL
VFRDGICxx / VFRSGICxx / VFRSHGICxx
These instructions should be read carefully and retained after installation by the
end-user for future reference and maintenance.
These instructions should be used to aid the installation of the following
products: VFRDGICxx / VFRSGICxx / VFRSHGICxx
GENERAL INSTRUCTIONS
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring
Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified
electrician
• Please isolate mains prior to installation or maintenance
• Please note the IP (Ingress Protection) rating of this fitting when deciding the
location for installation
If used under insulation, the insulation should be laid unbroken over the fitting (not packed
around it). Only mineral wool style insulation may be used
This product is Class I and must be earthed
The VFRDGICxx and VFRSGICxx series is IP20 rated, the VFRSHGICxx
series is IP65 (IP20 from above)
INSTALLATION
• Provide power to the required point of installation
Cut a suitable hole in the mounting surface as per the cut-out details
(see Fig. 1) ensuring not to infringe with any joists, gas/water pipes or electrical cables
INSTRUCTIONS VFRxxxx
These instructions should be read carefully and retained after installation by the end-user for future reference
and maintenance.
These instructions should be used to aid the installation of the following products:
VFRDGICxx / VFRSGICxx / VFRSHGICxx
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Please note the IP (Ingress Protection) rating of this fitting when deciding the location for installation
If used under insulation, the insulation should be laid unbroken over the fitting (not packed around it).
Only mineral wool style insulation may be used
This product is Class I and must be earthed
The VFRDGICxx and VFRSGICxx series is IP20 rated and, the VFRSHGICxx series is IP65 rated
INSTALLATION
Provide power to the required point of installation
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to
infringe with any joists, gas/ water pipes or electrical cables
Fig .1
Fold-out the terminal bracket until it locks into position (see Fig. 2)
Part code
Cut-out
VFRDGICxx
72mm
VFRSGICxx
84mm
VFRSHGICxx
72mm
Part code Cut-out
VFRDGICxx 72mm
VFRSGICxx 84mm
VFRSHGICxx 70mm
Fold out the terminal bracket until it locks
into position (see Fig. 2)
Replace Fig 2;
Replace Fig 3;
Fig. 1
Fig. 2
Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 3): L -
Live (brown), E - Earth (green/yellow), N - Neutral (blue). Two cables can be inserted into the push-fit
terminal block in order to achieve loop in / loop-out wiring
Fig. 3
Secure the mains cable under the cable clamp by closing the lid tightly
Lift both spring clips on the sides of the fitting and push into the ceiling (see Fig. 4)
Fig. 4
Remove the bezel by turning anti-clockwise (see Fig. 5), insert a suitable GU10 lamp into the bezel,
and connect the lamp to the lamp holder
Fig. 5
Insert the lamp into the body of the downlight and secure by turning the bezel clockwise. If using the
VFCFIPxx series, please ensure both gaskets are in place. One gasket is in the bezel and the other is
around the base of the fitting (see Fig. 6)
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
VFCFBC / VFCFC / VFCFW / VFCFIPBC / VFCFIPC / VFCFIPW / VFCFTBC / VFCFTC / VFCFTW
SAFETY
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with insulation)
This product is Class I and must be earthed
The VFCFxx and VFCFTxx series are IP20 rated; the VFCFIPxx series is IP65 rated
INSTALLATION
Provide power to the required point of installation
Cut a suitable hole in the mounting surface as per the cut-out details (see Fig. 1) ensuring not to
infringe with any joists, gas/water pipes or electrical cables
Fig. 1
Slot the terminal block into position on the fitting, and open the terminal access cover with the aid of a
flat-head screwdriver (see Fig. 2)
Fig. 2
Fig. 3
Fig. 4
Open the terminal access cover with the aid of a slotted screwdriver (see Fig. 3)
Connect the fitting to the mains supply ensuring that correct polarity is observed
(see Fig. 4): L - Live (Brown), E - Earth (Green/Yellow), N - Neutral (Blue)
Connect the luminaire to the mains supply ensuring the correct polarity is observed (see Fig. 3): L -
Live (brown), E - Earth (green/yellow), N - Neutral (blue). Two cables can be inserted into the push-fit
terminal block in order to achieve loop in / loop-out wiring
Fig. 3
Secure the mains cable under the cable clamp by closing the lid tightly
Lift both spring clips on the sides of the fitting and push into the ceiling (see Fig. 4)
Fig. 4
Remove the bezel by turning anti-clockwise (see Fig. 5), insert a suitable GU10 lamp into the bezel,
and connect the lamp to the lamp holder
Fig. 5
Insert the lamp into the body of the downlight and secure by turning the bezel clockwise. If using the
VFCFIPxx series, please ensure both gaskets are in place. One gasket is in the bezel and the other is
around the base of the fitting (see Fig. 6)
Replace Fig 4
Replace Fig 6
Fig. 5
Fig. 6
Ensure the strain relief is used to secure the mains input cable
Loop in/loop out wiring can be achieved with the push-fit terminal block
Lift both spring clips on the sides of the fitting and push into the ceiling (see Fig. 5)
Remove the bezel by turning anti-clockwise 45°, insert a suitable GU10 lamp into the lock ring
lamp clip and connect a lamp to the lamp holder (see Fig. 6)
Push the lamp and lock-ring up into position in the body of the downlight and secure the
lock-ring by turning clockwise 45°
For VFRSHGICxx series, please ensure both gaskets are in place. One gasket is
pre-installed with the bezel and the second gasket should be installed around the
base of the fitting (see Fig. 7)
Switch on and check for correct operation.
Fig. 7
GENERAL
This product should be recycled in the correct manner when it reaches the end of its life.
Check local authorities for where facilities exist.
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which
may damage the product.
This product is dimmable dependent on lamp type.
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product
in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper
use, or removal of the batch code will invalidate the warranty. If this product should fail
within its warranty period, it should be returned to the place of purchase for a free of
charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML
Accessories reserve the right to alter product specification without prior notice.
ML Accessories Limited LU5 4LT
www.mlaccessories.co.uk
DCAUG21_V5
08
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
INTERNATIONAL
CONTACT DETAILS
IC
RATED
/