WATTECO 50-70-168 Installation guide

Type
Installation guide

The WATTECO 50-70-168 is a versatile indoor sensor that measures temperature, humidity, CO2, VOCs, atmospheric pressure, light, and motion. With its ability to detect a wide range of environmental factors, it's ideal for monitoring air quality, energy consumption, and building occupancy, among other applications.

The WATTECO 50-70-168 is a versatile indoor sensor that measures temperature, humidity, CO2, VOCs, atmospheric pressure, light, and motion. With its ability to detect a wide range of environmental factors, it's ideal for monitoring air quality, energy consumption, and building occupancy, among other applications.

33-70-035-003
Indoor THR
50-70-162
50-70-191
Indoor T°C
50-70-167
Vaqa’O
50-70-168
Vaqa’O +
50-70-074
Move’O
50-70-220
Démarrer
Start
5 sec 3 sec 3 sec
Association
Red LED Green LED :
Network searching
LED rouge LED verte :
Recherche réseau
LED verte / Green LED
>1sec
Attendre / Wait Attendre / Wait
ON
OFF
>5 sec 3 sec 3 sec
Red LED
LED rouge
Red LED : Switching off
LED rouge : Extinction
Attendre / Wait
Provisionner l’appareil sur
votre réseau LoRaWAN
®
avec les clefs mises à
dispositions sur une
plateforme sécurisée.
Provision the device on
your LoRaWAN
®
network
with the keys available on
a secure platform.
Vue de côté
Side view
Vue face
Front view
Vue de côté
Side view
LEDs
Vue face
Front view
50-70-162
50-70-167
50-70-191
50-70-074
50-70-168
50-70-220
Vidéo / Video :
ON - OFF
https://youtu.be/
SiErE0zy4Q0
Installation
Setting up
L’installation doit se faire sur un mur à 1m50 du sol et qui nest pas en contact avec
l’extérieur. Le capteur doit être placé loin des fenêtres, d’un apport de chaleur (soleil,
radiateur, ventilation, entrée d’air).
The installation must be done on a wall at 1.5m from the ground and not in contact
with the outside. The collector should be placed away from windows, heat input (sun,
radiator, ventilation, air intake).
Mur intérieur
Interior wall
Mur extérieur
Exterior wall
~1m50
Installation
Setting up
Il faut dégrafer le capot du socle avec un tournevis à tête plate.
The cover of the base must be removed with a athead
screwdriver.
Placer les chevilles et visser le
socle au mur, dans le sens indiqué.
Place the dowels and screw the
base to the wall, in the direction
indicated.
Montage mural
Wall mounting
Installation du couvercle /
Installation of the cover :
1
2
1
2
50-70-162
50-70-167
50-70-191
50-70-074
50-70-168
50-70-220
Pour que le capteur fonctionne correctement, le nombre d’obstacles doit
être limité an d’éviter une atténuation excessive des ondes radio.
For the sensor communicates correctly, the number of obstacles should
be limited to avoid excessive radio attenuation.
Propagation radioélectrique
Radio propagation
Vérier la couverture
radio avec par exemple le
Netw’O.
Check the radio coverage
with the Netw’O.
IT 7IT 6
0.02
Tolérances générales en plasturgie selon la
norme NFT 58000 classe réduite.
General tolerances in plasturgie according to
standard NFT 58000 classifies reduced.
3
± 0.1
>3 à 6
± 0.1
>6 à 30
± 0.14
>30 à 120
± 0.23
>120 à 400
± 0.36
10
± 1°
10 à 50
± 30 ± 20
Dimensions linéaires
Linear dimensions
Dimensions angulaires
Angular dimensions
>50 à 120
< 10
>18 à 30
0.050.02
>30 à 100
0.1
>300
0.2 0.4 0.3
Axial
Radial
0.2
Tol. générales en
mécanique.
General tol. in
mechanics
Caractéristiques
Characteritics
Référence /
Reference
50-70-168 50-70-074 50-70-162
50-70-191 50-70-167 50-70-220
Classe /
Class
A A A A A
Niveau de puissance /
Power Level
+14 dBm +14 dBm +14 dBm +14 dBm +14 dBm
Mesures /
Measures :
T°C
Humidité /
Humidity
CO2
COV
Pression atmosphérique /
Atmospheric pressure
Luminosité /
Light
Détection mouvement /
Motion detection
Antenne /
Antenna
Interne
Internal
Interne
Internal
Interne
Internal
Interne
Internal
Interne
Internal
Matériaux du boîtier /
Casing materials
ABS UL94 V0 ABS UL94 V0 ABS UL94 V0 ABS UL94 V0 ABS UL94 V0
Indice de protection /
IP rating
IP30 IP30 IP30 IP30 IP30
xxx
xx
xx
xx
xx
xx
x
xx
xx
SITE SUPPORT CERTIFICATIONS
https://support.watteco.com/
Watteco représenté par JC LE BLEIS, déclare que l'équipement radioélectrique du type 50-70-168 / 50-70-074 /
50-70-162 / 50-70-167 / 50-70-220 / 50-70-191 est conforme à la directive 2014/53/UE (RED). Le texte complet
de la déclaration UE de conformité est disponible à l'adresse internet suivante: https://www.watteco.fr/assistance/
centre-de-telechargement/
Watteco represented by JC LE BLEIS, declares that the radio equipment type 50-70-168 / 50-70-074 / 50-70-162
/ 50-70-167 / 50-70-220 / 50-70-191 is in conformity with Directive 2014/53/EU (RED) and UKCA. The full text of
the EU and UKCA Declaration of Conformity is available at the following web address: https://www.watteco.com/
assistance/download-center/
Merci d’avoir choisi
les produits WATTECO
IoT device manufacturer
Thanks for choosing
WATTECO devices
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

WATTECO 50-70-168 Installation guide

Type
Installation guide

The WATTECO 50-70-168 is a versatile indoor sensor that measures temperature, humidity, CO2, VOCs, atmospheric pressure, light, and motion. With its ability to detect a wide range of environmental factors, it's ideal for monitoring air quality, energy consumption, and building occupancy, among other applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages