Skyfan SKYWCM-2 User manual

Type
User manual

Skyfan SKYWCM-2 is a wall control module designed for Skyfan DC ceiling fans without light. It allows you to control fan speed, set a timer, select different modes like Normal, Eco, and Sleep, and change the fan's direction from downdraft to updraft, making it an ideal solution for both summer and winter seasons.

Skyfan SKYWCM-2 is a wall control module designed for Skyfan DC ceiling fans without light. It allows you to control fan speed, set a timer, select different modes like Normal, Eco, and Sleep, and change the fan's direction from downdraft to updraft, making it an ideal solution for both summer and winter seasons.

INSTRUCTION MANUAL
Images are for reference only and may vary slightly from actual product.
Wall Control Module Installation Manual Rev 1
WARNING: FOR YOUR SAFETY, ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A
LICENSED ELECTRICIAN IN ACCORDANCE WITH AS/NZS 3000 WIRING RULES.
A CIRCUIT BREAKER (10A) TYPE C ACCORDING TO AS/NZS 60898-1 SHALL BE INSTALLED.
WALL CONTROL MODULE: SKYWCM-2
(Suits Skyfan DC models without light)
NOTE: WITHOUT LIGHT MODELS ONLY
CAUTION
Read Instructions Carefully For Safe
Installation and Fan Operation
MUST BE INSTALLED
BY A LICENSED
ELECTRICIAN
DIY
INSTRUCTION MANUAL
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN IN
ACCORDANCE WITH AS/NZ3000 WIRING RULES.
l Using 1 wall controller to control 1 Skyfan DC Ceiling fan.
ELECTRICAL WIRING DIAGRAM
OPERATION
N1
2
ELECTRICAL WIRING DIAGRAM
1. Connect “LIVE” supply to “L” on the controller,
2. Connect fan to “L1” of the wall controller.
3. Connect” NEUTRAL” to “N” of the wall controller.
4. Turn isolation switch “ON” a beep’ sound will be heard, and within 20 seconds, press and hold
on the wall controller for 3 seconds. The fan will emit another ‘beep beep’ sound to
indicate the pairing process is activated.
• Using 1 wall controller to control 1 x Skyfan DC Without Light Ceiling Fan.
N
L1
L
N
N1
L1
(AC 220-240V)
(CAN BE LEFT VACANT
OR USED AS “N” OUT)
(AC 220-240V)
(TO FAN)
(TO FAN)
L
Using 1 wall controller to control 2 or more Skyfan DC Without Light Ceiling fans.
NOTE: ONLY 1 (MASTER) FAN CAN BE CONNECTED TO CONTROL BOX. MAX 80 WATTS.
1. Connect “LIVE” supply to “L1” on the terminal controller.
2. Connect master fan to “L” of the wall controller.
3. Connect ”NEUTRAL” to “N” on the wall controller.
Pair the Master fan.
Pair the Master Fan rst. Turn isolation switch “ON” , a beep sound will be heard.
Within 20 seconds, press and hold button for 3 seconds The fan will emit another ‘beep
beep’ sound to indicate pairing has been successful.
1. Connect “LIVE” supply to “L” of the wall controller, connect fan “L” to “L1of the wall controller.
2. Connect “NEUTRAL” supply to “N” of the wall controller.
3. Turn isolation switch ON’, a ‘beep beep’ sound will be heard, and within 20 seconds, press and hold FAN or
on the wall controller for 3 seconds. The fan will emit another ‘beep beep sound to indicate the pairing
process is activated.
l Using 1 wall controller to control 2 or more Skyfan DC Ceiling fans.
1. Connect “LIVE” supply to “L1” of the wall controller, connect master fan “L” to “L” of the wall controller.
2. Connect “NEUTRAL” supply to “N” of the wall controller.
3. Choose the fan you wish to pair with.
4. Turn isolation switch ON’, a ‘beep beep’ sound will be heard, and within 20 seconds, press and hold FAN or
on the wall controller for 3 seconds. The fan will emit another ‘beep beep’ sound to indicate the pairing
process is activated.
5. Repeat steps 3 and 4 to pair with more fans.
WALL CONTROL OPERATION
N
L1
Master Fan
L
NStandard wall
(isolating) switch.
Not provided.
Standard wall
(isolating) switch.
Not provided.
Secondary Fans
N1
N
L1
L
N1
1. Connect “LIVE” supply to “L” of the wall controller, connect fan “L” to “L1of the wall controller.
2. Connect “NEUTRAL” supply to “N” of the wall controller.
3. Turn isolation switch ON’, a ‘beep beep’ sound will be heard, and within 20 seconds, press and hold FAN or
on the wall controller for 3 seconds. The fan will emit another ‘beep beep sound to indicate the pairing
process is activated.
l Using 1 wall controller to control 2 or more Skyfan DC Ceiling fans.
1. Connect “LIVE” supply to “L1” of the wall controller, connect master fan “L” to “L” of the wall controller.
2. Connect “NEUTRAL” supply to “N” of the wall controller.
3. Choose the fan you wish to pair with.
4. Turn isolation switch ON’, a ‘beep beep’ sound will be heard, and within 20 seconds, press and hold FAN or
on the wall controller for 3 seconds. The fan will emit another ‘beep beep’ sound to indicate the pairing
process is activated.
5. Repeat steps 3 and 4 to pair with more fans.
WALL CONTROL OPERATION
N1
N
L1
L
3
ELECTRICAL WIRING DIAGRAM CONTINUED
INSTALLING THE WALL CONTROLLER
Pair the Secondary fans.
Turn secondary fan isolation switch “ON” , a beep’ sound will be heard, and within 20
seconds, press and hold on the master wall controller for 3 seconds. The fan will emit
another ‘beep beep’ sound to indicate the pairing process has been successful. Repeat this process
for each of the secondary fans.
IMPORTANT NOTES FOR MULTI FAN OPERATION.
- All secondary fans should be within a 12m radius of the Master Wall controller to ensure reliable
connectivity.
- The Multi fan wiring format is different from the Single fan format. This allows the isolation switch
to cut power to the Master fan while still being able to operate the other secondary fans.
- It is possible to pair multiple secondary fans at once, as long as all fans can be paired within the
20 second pairing time restriction.
- All secondary fans should have their own isolating switch (not supplied).
Terminal
Housing
Fascia Base
1. Fix the wall controller base to the wall with two screws supplied.
2. Plug male connector of fascia into female connector of base piece (see diagram).
3. Secure the connector into the terminal housing
4. Clip fascia onto base ensuring cables are positioned in space provided.
4
WALL CONTROL OPERATION
Power ‘ON’ and ‘OFF’ (Isolation switch)
FAN Fan ‘ON’ and ‘OFF’
Increases fan speed until Max (speed 5)
Decreases fan speed until Min (speed 1)
TIMER Run on Timer with 12 setting options (1hr to 12hrs)
MODE ECO, SLEEP, and NORMAL
ECO MODE 1st press - Fan will operate at peak energy efciency
level, usually somewhere between speeds 1 and 2
SLEEP MODE 2nd press - Fan will reduce by 1 speed every 30mins
until speed 1. (select preferred starting speed level rst)
NORMAL
3rd Press - cancels mode and returns to normal function
Please note:
‘SLEEP’ or ‘ECO’ modes.
F/R
Press to change between Forward and reverse. ‘F’ and ‘R’ will be
visible on display screen
Forward - downdraft for cooling (summer mode)
Reverse - updraft for heat circulation (winter mode)
Model: SKYWCM-2
Suitable for all Skyfan DC Without Light Models
+
+ and will not operate during
-
-
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Skyfan SKYWCM-2 User manual

Type
User manual

Skyfan SKYWCM-2 is a wall control module designed for Skyfan DC ceiling fans without light. It allows you to control fan speed, set a timer, select different modes like Normal, Eco, and Sleep, and change the fan's direction from downdraft to updraft, making it an ideal solution for both summer and winter seasons.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI