Dryflow HDDFJFPLH-GRP Operating instructions

Type
Operating instructions

Dryflow HDDFJFPLH-GRP is a high-speed, energy-efficient hand dryer with a hygienic "no-touch" design. It features a tamper-proof timer to prevent misuse and an antibacterial coating on the air filter cover for added hygiene. Choose between "hot" or "cool" air and set the heater to "auto" or "all time" heating.

Dryflow HDDFJFPLH-GRP is a high-speed, energy-efficient hand dryer with a hygienic "no-touch" design. It features a tamper-proof timer to prevent misuse and an antibacterial coating on the air filter cover for added hygiene. Choose between "hot" or "cool" air and set the heater to "auto" or "all time" heating.

Instructions
Jet Force Plus Hand Dryer
Instructions
Thank you for your purchase. Please read these instructions before
installation and/or use and keep in a safe place for future reference
Dryflow, 7 Riverside Court, Don Road, Sheffield, S9 2TJ. UK.
+44 (0)114 3540047 | [email protected] | www.dryflow.co.uk
HOW TO USE................................................
TROUBLESHOOTING.....................................
ROUTINE CLEANING....................................
WARNING.....................................................
FEATURES......................................................
CONTENTS
INSTALLATION METHODS.............................
COMPONENTS.............................................
SPECIFICATION............................................
1
2
3
4
8
9
9
3
HOW TO USE
TROUBLESHOOTING
HOW TO DRY THE HANDS
Place the hands in to
the drying cavity Slowly draw the hands
out Stop when the hands
are dry
If the following problems occur, please perform these checks and actions
Problem Check Action
No air blows when
hands are inserted
The unit doesn’t stop
running when the
hands are removed
No hot air comes out
the hand dryer
The indicator light is
flashing
If the above actions do not work, turn off the power and the ground-fault circuit breaker and contact the
company you bought the hand dryer from for further advice.
Do the display indicators
light up?
Is the power switch on?
Are the hands fully inserted
to activate the sensor?
Is the sensor blocked by dirt
or dust?
Is the heater switch on the
"hot"
setting?
Is the heater setting switch on
"A uto Heating" setting or "All
Time Heating" setting?
Is the heater element faulty?
- Turn the heater switch to the ""hot" setting.
- Turn the heater setting switch to the "All Time Heating" setting.
- Turn the power switch off. Remove the front cover, then
remove the cover of the teminal box. Check the 3 fuses
(terminal connector) for any faults.
Check for problems with the
power supply
Turn the power switch off. Check all the indicators in the
display indicator have gone off (after around 40
seconds), then turn on the power switch again.
Turn the power switch off. Wait for the indicator lights
to go out then remove any dirt or dust from the sensor.
- Turn the ground fault circuit breaker on
- Turn the power switch on
- Put the hands all the way into the cavity to activate
the sensor.
ROUTINE CLEANING
WARNING If you don’t use this unit properly or
follow the safety guidelines carefully, it
may lead to serious personal injury
Prohibited
Do not place
near excessive
water sources
Disassembling
is prohibited
instructions
with all
comply
Please
Earth
grounding
connection
• Do not open the front panel, otherwise this may cause an
electric shock.
• Do not install the hand dryer too close to excessive water sources
such as bathtubs, showers and basins, otherwise this may cause
electric shock or unit malfunction.
• Do not modify or disassemble the unit unnecessarily as this may
lead to fire, electric shock or personal injury.
• Use a single phase AC 220-240V/50/60Hz power supply.
• Use within the required voltage, as voltage exceeding 220V +
10% will cause the unit to fail. Using an incorrect power supply may
lead to fire, electric shock or unit malfunction.
• Ensure each unit has its own dedicated power cable that is not
shared with any other appliance to avoid the risk of fire.
• Turn off the power switch before any maintenance or cleaning
takes place on the hand dryer. Otherwise this may cause an
electric shock.
• Ensure the unit is properly grounded. Otherwise it may cause an
electric shock or short circuit.
• Installation work should be done by a qualified technician to
avoid the risk of electric shock or fire.
• Be sure to install a residual current circuit breaker, otherwise this
may cause an electric shock.
• Use contact points that are at least 3mm apart
- Please only use products that comply with your countries Safety
Standards.
- Recommended residual current circuit breaker (for ground fault
protection). (Use a single phase 2-line, AC 220-240V50/60Hz cable
with a 20A rated current, 15mA-type rated operating current).
Cleaning the main body
Perform regularly
Emptying and cleaning the drain tank
Check at least once a week
Cleaning the air filter
Perform approx once a week
• Clean the unit with a damp soft cloth.
If the unit gets excessively dirty, clean with a soft cloth dampened with a neutral
detergent, then use a dry soft cloth to finish.
• Remove dirt and dust from the sensor to prevent malfunction.
WARNING
• Before you clean the unit,
turn off the power switch.
• Do not use excessive
amounts of water on the unit.
Caution
• Wear gloves when cleaning
Note
• Only use neutral detergent / cleaning agents
• Do not use thinner, acidic or alkaline cleaners, or a nylon
brush, otherwise this may damage the hand dryer cover
• Only use alcohol (disinfecting concentration below 83%) on
the hand drying area, nowhere else on the hand dryer.
• If using chemical cloths, be sure to read their instructions
before use.
• Strong disinfecting agents may damage the unit.
• The antibacterial coating is effective when
bacteria is exposed to the coated surfaces
• The antibacterial coating is less effective
when the surfaces are dirty
• Water blown off the hands will enter the drain tank.
• It is advisable to check the drain tank regularly to avoid exceeding
the full level.
• Leaving water in the drain tank for a significant period of time could
lead to unpleasant smells.
Pull the drain tank out in a horizontal
direction
This ensures that the water
doesn’t spill or splatter
Full Level Drain Tank
Cover
Cover
Full Level
Full Level
1. Open the cover and empty the
water.
Pull the cover up with your fingers in
the direction of the arrow on top of
the cover, then remove the cover
completely.
2. Wash out the interior of the drain
tank.
3. Close the drain tank cover and
replace it back in the unit.
Check that the drain tank is firmly
inserted back in place.
Add 200ml of water through the
drain hole to prevent it from
getting clogged.
Continue to use the unit after
confirming the drain tank is in
place.
Drain Hole
• Remove the air filter.
Pull the air filter out by the
handle.
Handle
1. Cleaning the air filter.
Beat it lightly by hand or use a
vacuum cleaner.
If it is very dirty, wash with cold or
warm water*.
2. Replace the air filter into the
unit.
Make sure it is inserted all the
way into the unit until it stops. If it
is not in place, dirt and dust will
enter the unit and shorten its
service life.
Air Filter
Note
• *If you wash the air filter with water you need to
make sure it is completely dry before replacing it
to the unit.
• Do not expose the filter to fire.
WARNING
FEATURES
INSTALLATION METHODS
• “No touch” hand drying ensures complete hygiene.
• High-speed, low cost hand drying.
• A tamperproof timer prevents misuse*.
• No need for paper towels; ease of maintenance.
• Air filter with antibacterial coating on cover.
*To prevent misuse, the tamperproof built in timer will automatically stop the unit after 30 seconds of
continuous sensor activation. Once the hands are removed and put back into the drying cavity the
hand dryer will activate again as normal.
If you don’t use this unit properly or
follow the safety guidelines carefully, it
may lead to serious personal injury
Prohibited
instructions
with all
comply
Please
• Always use the unit with the drain tank and air filter in place. If water
is allowed to enter the inside of the unit it may cause short circuit or
electric shock.
• If the unit does not start or works abnormally, turn off the power
switch and ground fault breaker and contact the place where you
purchased the unit to arrange inspection or repair.
• Do not use in the following places:
- Where the unit may come into direct contact with excessive water.
- Where the unit is under direct or strong sunlight (this may cause the
sensor to malfunction).
- Where condensation may form within the unit.
• Safety precautions before installing the unit:
- Do not attempt to install the unit with the power on, otherwise this
may cause an electric shock.
- The installation location should be strong enough to support the unit.
The unit should be installed firmly to the wall. Otherwise this may lead
to personal injury if the unit falls.
• Ensure children are not allowed to play with the
hand dryer and are supervised at all times.
INSTALLATION METHODS COMPONENTS
SPECIFICATION
Rated Voltage
Rated Frequency
Rated Power
Motor Power
Ingress Protection
Air Speed
Drying Time
Overall Size (mm)
AC220-240V
AC110-127V
50/60HZ
800W +
(PTC 850W)
800W
IPX4
90m/s
10s
300 x 220 x 687
Switch Panel
Power Indicator Self-Check Indicator
Blue LED Lights
Hand Drying Area
Sensor
Main Body
Drain Hose
Air Filter
Drain Tank
Full Level Indicator
• Before starting to operate the hand dryer.
- Turn on the power switch (located on the lower part of the switch panel).
- The power indicator light at the top of the hand dryer will light up.
- The blue LED lights in the hand dryer cavity will light up.
• PTC heater control: There are 2 switches in the upper part of the switch panel.
- The switch to the right allows for a “Hot” or “Cool” setting. This turns the heater element on or off, respectively.
- When the “Hot” setting is chosen, the switch to the left allows for an “Auto Heating” or “All Time Heating” setting.
1. When set to “Auto Heating” the heater element is automatically activated when the ambient temperature of the room is
less than approx. 25oC and automatically inactive above this temperature.
2. When set to “All Time Heating” the heater element is active at all times no matter what the ambient temperature of the
room is.
INSTALLATION METHODS INSTALLATION METHODS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Dryflow HDDFJFPLH-GRP Operating instructions

Type
Operating instructions

Dryflow HDDFJFPLH-GRP is a high-speed, energy-efficient hand dryer with a hygienic "no-touch" design. It features a tamper-proof timer to prevent misuse and an antibacterial coating on the air filter cover for added hygiene. Choose between "hot" or "cool" air and set the heater to "auto" or "all time" heating.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI