ALTV2416220 Series

Altronix ALTV2416220 Series Installation guide

  • Hello! I've reviewed the installation guide for the Altronix ALTV2416220 series CCTV power supplies. This document provides details on models with 16 fuse or PTC protected outputs, operating at either 24VAC or 28VAC. It covers installation, voltage selection, and features like surge suppression and LED indicators. Feel free to ask me any questions about the setup or specifications.
  • What is the input voltage for these power supplies?
    How many outputs do these power supplies have?
    What type of output protection is provided?
    What are the output voltage options?
Rev. 120105 More than just power.TM
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
ALTV2416220 Series
16-Output CCTV Power Supplies
Models Include:
ALTV2416220
- 24VAC @ 8A (200VA) or
28VAC @ 7A (200VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416350220
- 24VAC @ 14A (350VA) or
28VAC @ 12.5A (350VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416300M220
- 24VAC @ 12.5A (300VA) or
28VAC @ 10A (300VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416600220
- 24VAC @ 28A (700VA) or
28VAC @ 25A (700VA).
- Sixteen (16) Fuse Protected Outputs.
ALTV2416CB220
- 24VAC @ 8A (200VA) or
28VAC @ 7A (200VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416350CB220
- 24VAC @ 14A (350VA) or
28VAC @ 12.5A (350VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416300CBM220
- 24VAC @ 12.5A (300VA) or
28VAC @ 10A (300VA).
- Sixteen (16) PTC Protected Outputs.
ALTV2416600CB220
- 24VAC @ 28A (700VA) or
28VAC @ 25A (700VA).
- Sixteen (16) PTC Protected Outputs.
Installation Guide
- 2 - ALTV2416220 Series Installation Guide
Overview:
Altronix ALTV2416220 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen(16) fuse or
PTC protected outputs for powering CCTV cameras, heaters and other video accessories.
Sixteen (16) Output ALTV2416220 Reference Chart:
Altronix
Model Number
Output Voltage
Total Output
Current (Power)
Number of
Outputs
PTC Protected
Outputs
(auto-resettable)
Fuse Protected
Outputs
Output Current
(max. per output)
Main
Fuse Ratings
220VAC
50/60Hz Input
Current
ALTV2416220 24VAC 8A
16
P3.5A 5A/
250V 0.5A
28VAC 7A
ALTV2416CB220 24VAC 8A P– 2.5A
28VAC 7A
ALTV2416350220 24VAC 14A P3.5A
15A/
250V
1.5A
28VAC 12.5A
ALTV2416350CB220 24VAC 14A P– 2.5A
28VAC 12.5A
ALTV2416300M220 24VAC 12.5A P3.5A
28VAC 10A
ALTV2416300CBM220 24VAC 12.5A P– 2.5A
28VAC 10A
ALTV2416600220 24VAC 28A P3.5A
3A
28VAC 25A
ALTV2416600CB220 24VAC 28A P– 2.5A
28VAC 25A
Specifications:
Agency Listing:
• CE European Conformity.
Input:
• 220VAC, 50/60Hz.
Output:
• Sixteen (16) fuse or PTC protected outputs.
• 24VAC or 28VAC supply current.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• AC power LED.
• Power ON/OFF switch.
Spare fuses provided.
(all models w/primary and/or secondary fuses).
Features (cont’d):
Unit maintains camera synchronization.
Ease of installation saves time & eliminates
costly labor.
Spare fuses included (on fuse protected models).
Enclosure Dimensions:
ALTV2416220 and ALTV2416CB220:
8.5” x 7.5” x 3.5”
(215.9mm x 190.5mm x 88.9mm).
ALTV2416300M220 and ALTV2416300CBM220:
8.5” x 7.5” x 3.875”
(215.9mm x 191mm x 98.4mm).
ALTV2416350220, ALTV2416350CB220,
ALTV2416600220, and ALTV2416600CB220:
13.5” x 13” x 3.25”
(342.9mm x 330.2mm x 82.6mm).
ALTV2416220 Series Installation Guide - 3 -
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in theenclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install three fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 9-12). Secure enclosure to earth ground.
2. Slide switch on PD board to the OFF position for models ALTV2416220 and ALTV2416CB220 (Fig. 1, pg. 4).
Turn OFF main switch on all other models, (Figs. 2-5, pgs. 5-8).
3. All units are factory set for 24VAC operation. For 28VAC operation adjust unit prior to mounting and applying
power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked
[P] and the yellow wire [24V] is connected to the terminal marked [S].
4. Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to
the terminal marked , Line connects to the terminal marked [L], and Neutral connects to the terminal
marked [N] of the Inlet Appliance Connector. (Figs. 1-5, pgs. 4-8).
Use 18 AWG or larger for all power connections.
5. Slide switch SW1 to the ON position on models ALTV2416220 and ALTV2416CB220 (Fig. 1, pg. 4).
Turn main switch on all other models to the “RESET” (ON) position (Figs. 2, 3, pgs. 5, 6).
6. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P - 8P] are positive of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before
adjusting the output voltage.
7. Slide switch on PD board to the OFF position for models ALTV2416220 and ALTV2416CB220
(Fig. 1, pg. 4). Turn OFF main switch on all other models, (Figs. 2-5, pgs. 5-8).
8. Connect devices to the terminals marked [1P - 1N] through [8P - 8N] on PD8/PD8CB board (Fig. 5, pg. 8)
or terminals marked [1P - 1N] through [16P - 16N] on PD16W/PD16WCB board (Figs. 1-4, pgs. 4-7),
carefully observing polarity.
9. Slide switch on PD board to the ON position for models ALTV2416220 and ALTV2416CB220
(Fig. 1, pg. 4). Turn main switch on all other models to the “RESET” (ON) position (Figs. 2-5, pgs. 5-8).
10. Green LED will illuminate when unit is powered.
11. Upon completion of wiring, secure enclosure door with screws (supplied).
CAUTION: Equipment to be installed / serviced by authorized / trained personnel only.
Shut branch circuit power before installing / servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to the National
Electrical Code and all local codes.
Terminal Identification:
PD8/PD8CB - Distribution Module
1P - 8P AC output.
1N - 4N AC output.
PD16W/PD16WCB - Distribution Module
1P - 16P AC output.
1N - 16N AC output.
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
PD8
ON OFF
1 2 3 4 5 6 7 8
N P S
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
PD8
ON OFF
1 2 3 4 5 6 7 8
N P S
PTCs
used on
ALTV2416CB220
Input 220VAC 50/60Hz, 0.5A
1A
250V
- 4 - ALTV2416220 Series Installation Guide
Fig. 1 - ALTV2416220 and ALTV2416CB220
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
PD8
ON OFF
1 2 3 4 5 6 7 8
N P S
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
PD8
ON OFF
1 2 3 4 5 6 7 8
N P S
PTCs
used on
ALTV2416CB220
Input 220VAC 50/60Hz, 0.5A
1A
250V
Enclosure Door Back Panel of Enclosure
NP S
NP S
24VAC
Output
(Yellow) (Black)
(Black) (Yellow)
28VAC
Output
Voltage Selection
Configuration
ALTV2416220 Series Installation Guide - 5 -
Fig. 2 - ALTV2416350220 and ALTV2416350CB220
Input
220VAC
50/60Hz,
1.5A
4A
250V
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
N P S
PD8
1 2 3 4 5 6 7 8
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
N P S
PD8
1 2 3 4 5 6 7 8
PTCs
used on
ALTV2416175CB220
Illuminated
Power Switch
NP S
NP S
24VAC
Output
(Yellow) (Black)
(Black) (Yellow)
28VAC
Output
Voltage Selection
Configuration
- 6 - ALTV2416220 Series Installation Guide
Fig. 3 - ALTV2416300M220 and ALTV2416300CBM220
N
PD16W
XFMR INPUT SP
P N
312 45678
PROTECTED
OUTPUTS
OUTPUTS
COMMON
111091213
P
161514
N
PTCs
used on
ALTV2416300CBM220
Illuminated
Power Switch
3.5A 250V
4A
250V
Input 220VAC
50/60Hz, 1.5A
NP S
NP S
24VAC
Output
(Yellow) (Black)
(Black) (Yellow)
28VAC
Output
Voltage Selection
Configuration
ALTV2416220 Series Installation Guide - 7 -
Fig. 4 - ALTV2416600220 and ALTV2416600CB220
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
N P S
PD8
1 2 3 4 5 6 7 8
INPUT
MAIN FUSE
FUSED POWER OUTPUTS
COMMON POWER OUTPUTS
N
P
N P S
PD8
1 2 3 4 5 6 7 8
PTCs
used on
ALTV2416600CB220
Illuminated
Power Switch
Input 220VAC,
50/60Hz, 3A
4A
250V
NP S
NP S
24VAC
Output
(Yellow) (Black)
(Black) (Yellow)
28VAC
Output
Voltage Selection
Configuration
- 8 - ALTV2416220 Series Installation Guide
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of
sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-
tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
ALTV2416220 Series Installation Guide - 9 -
Notes:
- 10 - ALTV2416220 Series Installation Guide
7.25” (184.2mm)
3.625” (92mm)
1.25”
(31.8mm)
3.5” (88.9mm)
6.05” (153.7mm)
1.125”
(28.6mm)
1.125”
(28.6mm)
0.6” (15.2mm)0.6” (15.2mm)
0.6” (15.2mm)0.6” (15.2mm)
2” (50.8mm)2” (50.8mm)
8.125” (206.4mm)
1”
(25.4mm)
1”
(25.4mm)
1”
(25.4mm)
1.25”
(31.75mm)
1.25”
(31.75mm)
1”
(25.4mm)
1”
(25.4mm)
5.25” (133.35mm)
6.05” (153.7mm)
3.5” (88.9mm)
Enclosure Dimensions (H x W x D) for:
• ALTV2416220 • ALTV2416CB220
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
ALTV2416220 Series Installation Guide - 11 -
3.63” (92.2mm) 1.25” (31.75mm)
3.85” (97.79mm)
7.25” (184.15mm)
1.75” (44.45mm) 1” (25.4mm)
0.6” (15.24mm) 0.6” (15.24mm)
0.9” (22.86mm)
0.9” (22.86mm)
8.13” (206.5mm)
3.85” (97.79mm)
1.25” (31.75mm)
1” (25.4mm)
1” (25.4mm) 1” (25.4mm)
1” (25.4mm)
1” (25.4mm)
1.25” (31.75mm)
1” (25.4mm)
1.25” (31.75mm)
0.6” (15.24mm) 0.6” (15.24mm)
Enclosure Dimensions (H x W x D) for:
• ALTV2416300M220 • ALTV2416300CBM220
8.5” x 7.5” x 3.875” (215.9mm x 191mm x 98.4mm)
- 12 - ALTV2416220 Series Installation Guide
1.40”
(35.6mm)
1.40”
(35.6mm)
1.40”
(35.6mm)
4.85” (123.2mm) 4.85” (123.2mm)
3.25” (82.6mm)
0.75”
(19.1mm)
0.75”
(19.1mm)
11.0” (279.4mm)
12.5” (317.5mm)
1.20”
(30.5mm)
1.20”
(30.5mm)
0.9375” (23.8mm)
0.9375” (23.8mm)
5.10” (129.5mm)
1.40”
(35.6mm)
5.10” (129.5mm)
6.5625” (166.7mm)
3.25” (82.6mm)3.25” (82.6mm)
3.25” (82.6mm)
10.5” (266.7mm)
1.0”
(25.4mm)
1.0”
(25.4mm)
1.0” (25.4mm)
13.0” (330.2mm)
5.10” (129.5mm)
1.20”
(30.5mm)
Enclosure Dimensions (H x W x D) for:
• ALTV2416350220 • ALTV2416350CB220• ALTV2416600220 • ALTV2416600CB220
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
Altronix is not responsible for any typographical errors.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIALTV2416220 Series C21V MEMBER
/