Trakker Antares 2481

Intermec Trakker Antares 2481, Trakker Antares 2480, Trakker Antares 2485, Trakker Antares 2486 Install Manual

  • Hello! I am an AI chatbot trained to assist you with the Intermec Trakker Antares 2481 Install Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Part No. 068251-002
TRAKKER Antares 248X COM4 Adapter Cable Installation
Instruction Sheet
You can attach the COM4 adapter cable (Part No. 067185) to a TRAKKER
Antares
2480,
2481, 2485, or 2486 (T248X) terminal to use an additional serial port for RS-232 serial
communications. COM4 is only available on a T248X with the option for the enhanced
input/output board.
To install the adapter cable
1. Use a Phillips screwdriver to remove the six screws on the back panel.
2. Remove the back panel and place it on a clean surface.
3. Connect the COM4 adapter cable to the COM4 connector.
248XIC4C.001
Back panel
Screw
(6 places)
Cable
restraint
bar
Scissors
seal
COM4
connector
COM4
adapter
cable
9-pin
RS-232
connector
Cable
restraint
4. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the
COM4 adapter cable under the cable restraint. Tighten the screw to secure the cable.
5. Route the COM4 adapter cable under the cable restraint bar and through the scissors seal.
6. With the seal facing toward the terminal, place the back panel on the back of the terminal.
7. Use a Phillips screwdriver to tighten the six screws to 19 in-lb torque.
8. Connect the 9-pin RS-232 connector from a serial device to the COM4 adapter cable on the
back of the terminal.
9. Configure COM4. For help, see the TRAKKER Antares 248X Stationary Terminal User’s
Manual (Part No. 066960).
Pin Assignments
The next illustrations show the pin assignments for the 9-pin connector (host connection) and
the 10-pin connector (terminal connection) on the adapter cable.
9-Pin Connector Pin Assignments
Not connected - 6
Request to send (RTS) - 7
Clear to send (CTS) - 8
Not connected - 9
1 - Not connected
2 - Received data (RXD)
3 - Transmit data (TXD)
4 - Data terminal ready (DTR)
5 - Ground (GND)
248XIC4C.003
10-Pin Connector Pin Assignments
1 - Received data (RXD)
3 - Transmit data (TXD)
5 - Data terminal ready (DTR)
7 - Ground (GND)
9 - Not connected
Request to send (RTS) - 2
Clear to send (CTS) - 4
Not connected - 6
Not connected - 8
Not connected - 10
248XIC4C.003
6001 36th Avenue West
P.O. Box 4280
Everett, WA 98203-9280
© 1998 Intermec
All Rights Reserved
P/N 068251-002
/