Air-O-Swiss AOS 7142 Owner's manual

Category
Humidifiers
Type
Owner's manual
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS 7135
5
en
Instructions for use
6
en
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafeplace
forlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonlyper
mittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contaminationfree,cold,freshtapwa
terinyourhumidifier.Ifyourwatersourceiscontam
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
8
en
Foreword
Congratulations on choosing the Ultrasonic humidifier
7135!
Didyouknowthatdryroomair:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
Acomfortableatmosphereindoorsisreachedwithare
lativehumiditylevelbetween40and 60%.Yourhumidi
fier automatically controls the humidity level according
todesiredsetting.Iftheairistoodry,thehumidifierwill
automaticallyswitchon.Assoonasthedesiredhumidity
levelisreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandlebasemayfallandwillbeda
maged(11).
• Warning:Themistoutletispackedinaredbaginside
theboxinsert.Makesurethatyouremovethemist
outletfromthepackaging(12).
• Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
12
9
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,
furniture,orotherobjects(13).Keepdistanceofat
least20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(14).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshould
bereplacedevery2–3monthsdependingonyour
waterhardness.Someareasmayneedtoreplacethe
cartridgesooner,somemaylastlonger.Thecartridge
mustbeexchangedatthelatestafter6monthsorthe
unitdoesnotreachitsfullperformanceanymore.
 See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(15and16).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).
• About10to15minutesafteritisswitchedonthe
devicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
Membrane
Controlpanel
Airinlet
Mistoutlet(rotating)
Demineralizationcartridge
Watertank
Evaporationchamber
Brush
Waterbase
Powerplug
Waterlevelsensor
Mainbody
Description of the appliance
Watertankcap
HydroCell
24 h
14
13
10
en
17
18
16
15
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyand proper humidi-
fierfunctionuseonlyclean,contaminationfree,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewaterreachestheminimumlevel,theunit
switchesoffthenebulizerfunctionautomatically.Thered
lightcomesonindicatingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(15).Caution:themistoutletisloose!
• Makesurethatnoforeignobjectsareinthewater
tank.
• Fillthetankwithclean,coldwaterfromthetap(16).
Closethecapofthewatertanksecurely,placethe
watertankontothebase(17).Thewaterisnow
runningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(18).
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).Theredempty
indicatorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
19
11
en
C) Timer
Using button C, the operation time can be set adjusta
blebetween 1and9 hours orco(continious operation).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/9h/co).Thedisplaywillautomat
icallyshowthecurrentvalueafterafewseconds.
D) Mist output (regulating mist output)
The mist output can be regulated by pressing button
Dseveral times. If thered bars aredisplayed,youhave
selectedthehighestlevelofmistoutput(symbol H).
E) Operation with water pre-heating
(warm mist)
ButtonEisusedforswitchingthepreheatingonandoff
(symbol Ilightsup).Asaresult,thewaterispreheated
toatemperature of 176°F(80°C)beforeentering the
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnow leavesthe
humidifieratapleasanttemperatureof104°F(40°C).The
advantageofthisisthattheroomtemperaturedoesnot
dropand,in addition, it significantlyimproves thewater
qualitymaintenance.
F) Automatic mode and Sleep mode
Theautomaticandsleepmodescanbeactivatedbypres
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempera
ture.Controltakesplacebymeansofoutputquantityand
presettargetvalue. If the sleep function is switchedon
(thesymbol Kappearsonthedisplay),thetargethumidity
is60%;theoperationtimeisautomaticallysetat8hours;
theheatingisswitchedon.Inaddition,theoutputquantityis
alsocontrolledsubjecttothedifferencebetweenthetarget
valueandtheactualvalue.
TheTimercannotbechangedineithermode.Ifotherbut
tonsarepressed,theunitwillnolongerbeinautoorsleep
mode.
A) On / Off button
YoucanswitchtheunitonoroffbypressingbuttonA.This
buttonisalsousedtoresetthecleaningindicatorlight(by
holdingdown).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity
level in %. A relative humidity between 40% and 60%
isrecommended.Theaccuracyofmeasurementis+/5%.
Theunitwillswitchoffwhenthemoisturelevelexceedsthe
desiredsetting.Thedevicedoesnotswitchoffifthedis
playissetto«Co»(continuousoperation).Duringselection
thetargetvalueisdisplayed.Thedisplaywillautomatically
showthecurrentvalueafterafewseconds.
Operation 7135 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolL).
Pleasereadthechapter«Fillingthetank»formoreinforma
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolMand«CLEAN»appearonthedisplay,theappli
anceshouldbecleanedasrecommendedbythemanufac
turer.Thissymbolcomesonautomaticallyevery2weeks,
dependingonthelevelofuse.The display can be reset
by holding down button A until the light disappears.
A
BC
DEF
M
LG
HIKJ
12
en
ACID
22
2521
24
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheapplianceandunplugitfromthesocket
beforecleaningit(20).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(21).
• UseEZCalandEZCalProcustomcleaninganddesca
lingagentsonlytoremovedepositsfromthememb
raneregularly(22and23).ThereisasampleofEZCal
includedinthepackagingofyourhumidifier.Instruc
tionsforusingareonthepacket.Onlyuse1packetfor
32ozofwater.Donotchangetheratio.DoNOTrunthe
unitwhenusingEZCalandEZCalPro.Thiscancause
damagetotheproductandvoidsthewarranty.Tho
roughlyrinsethebasewithtapwaterafterusingEZCal
andEZCalProandmakesurenoEZCalandEZCalPro
residuesremainsinthebase.
23
20
26
13
en
27
Water quality maintenance
TheHydroCellkeepshumidifiersoperatingattheirhighest
levelbetweenrecommendedcleanings.Goodforapproxi
matelyonetotwomonths,dependingonthewaterquality,
theHydroCellensuresthehumidifier’sfunctionalitywhile
providing fresh humidification performance. It starts to
workassoonasitcomesintocontactwithwater,even
iftheunitisturnedoff.TheHydroCellshouldbechanged
everyonetotwomonths*.Lookatpicture27/28forthepo
sitionoftheHydroCellinthewatertankoftheunit.Switch
offtheunitfirst.Contactyourlocalretailerorcheckour
websitewww.airoswiss.netforreorderinformation.
*Dependingonthewaterquality.
28
EZCalandEZCalProaretheonlyrecommended
cleaninganddescalingsolutions.DoNOT use
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalandEZCalProwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• Thecleaningindicatorstillappearsonthedisplayafter
cleaning.ToresetitholddowntheON/OFFbuttonuntil
thecleanlightstopsflashing.
• Cleantheinnerpartswithasoftcloth.Donotuseany
solventsoraggressivecleaningagentstocleanthe
appliance(25).
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoftbristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.
14
en
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Thewatertankisequippedwithademineralizationcartridge.
This cartridgehas to be replacedevery 2 – 3 months. If
thewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Pleasenotewhitedust
isnotharmful.Ifwhiteresiduestillformsaroundthedevice
afteranewcartridgehasbeeninserted,pleasemakesure
thatthewateryouareusingisuntreated.Ifthewaterflows
throughadecalcificationsystem–suchasanionexchanger
–(sodiumisaddedtoremovecalcium)inthebuildingbefore
itisusedinthehumidifier,saltcanprecipitateaswhitedust
aroundthedevice.Thedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6monthsor
theunitdoesnotreachitsfullperformanceanymore.
Option A: replace the resin
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(31).
•Throwthecontentintothewaste(Attention!Disposed
resincanmakethefloorslippery!)(32).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(33).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(34).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(35).
•Turntheplasticcupandcartridgeoverandshakeuntil
allresinisinthecartridge(36).
29
30
31 32
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(37)andretainforfutureuse(the
refillresinconsistsof3refillbags)(38).
•Closethecartridge(39).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(44).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(40).
•Unpackthenewcartridge(41).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).Close
tankcapwellandplacethetankonthemainbody
(44).
16
en
Technical data
Electricalvoltage 120V/60Hz
Powerconsumptionupto 45W/(140W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m
2
Dimensions(LxWxH) 15x8.7x13.8in
38x22x35cm
Weight(empty) 7.7lbs/3.5kg
Accessories 7531Demineralizationcartridge
HydroCellA200
 EZCalA7417
EZCalProA100
*whenusedwithpreheatingto176°F(80°C)
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscULlisted.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website www.
airoswiss.netforreorderinformation.
Customer Service
CustomerService(USA)18003360326
www.airoswiss.net
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCalandEZCalPro
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow
withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandEZCalProandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
17
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleavingen
oughmoisturefortheair.Ifthewindowisleftopen,
thenthisallowsmoisturetoescapetheroom.Ano
therfactorisalotoftimestheunitisplacednextto
aheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects(dry
outandeventuallycracksappear),discomfort,sick
ness,anddriesoutnasalmembranes.
Overhumidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefreestandingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization
cartridge (DMC)?
A. TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobeso
akedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverseosmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
18
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter12
monthswhenyouuseveryhardwater(forsofterwater
after23months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapreinstalledwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverseOsmosiswater(ROwater)insteadofdis
tilledwaterandremovethedemineralizationcartridge.
•Cleaning light is illuminated (digital models)
Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donot
submergethebase!Visuallyinspectthebasefordirt
ormineralbuildup.Ifsoftwaterisuseddecalcifying
theunitevery4weekswithEZCalissuggested.Ifhard
waterisusedtheunitshouldbedecalcifiedevery2
weeks.Donotforgettoresetthecleanlightafter
resettingtheunit.
Q.Reset cleaning light (digital models)
A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)
untilthelightstopsflashing.Thelightautomatically
comesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimaticcon
ditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchangedse
veraltimesperday–thehumidifierneedstostartsits
workfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–highrisebuil
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan2
timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunitifitisplacedclosetoadoor,win
doworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnotflas
hingyoumighthavesetthedesiredhumiditytoolow
andthecurrenthumiditylevelintheroomishigher.
Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after23months,inareaswithhardwaterexchange
thecartridgeafter12months.However,thedemi
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.
19
en
Q.Water tank cap is too tight to unscrew
A. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthe
watertankcaptoreleaseairfromthewatertank.
Continuetodothisuntilyouareabletounscrewthe
watertankcap.
Q.Unit is running intermittently.
A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If23monthshavepassed,
itistimetoreplacethecontentsofthecartridge.
Howeverthedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6
monthsortheunitdoesnotreachitsfullperformance
anymore.
•Ifthecontentsofthecartridgewerejustreplacedthere
areprobablytoomanygranulesinthecartridge.Re
move2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the
demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiece
thatattachesthedemineralizationcartridgetothe
watertank).
Q.What is the Hydro Cell and how long is it good for?
A.TheHydroCellkeepshumidifiersoperatingattheir
highestlevelbetweenrecommendedcleanings*.Good
forapproximatelyonetotwomonths,dependingonthe
waterquality,theHydroCellensuresthehumidifier’s
functionalitywhileprovidingfreshhumidification
performance.Itneedstobereplacedeveryonetotwo
months*.
*Dependingonthewaterquality.
Q.Placement of the Hydro Cell
A.Pleaseseepicture27/28forinstructions.
Q.What is EZCal and EZCal Pro?
A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalandEZCalProare
usedforcleaninganddescalinganyofthehumidifiers
andcleansmineralbuildup.EZCalandEZCalProare
theonlyrecommendedcleaninganddescalingsolu
tions.DoNOTuseanyothercleaningsolutionssinceit
candamagetheproduct.Anyuseofcleaningsolutions
apartfromEZCalandEZCalProwillvoidthewarranty.
Instructionsforusingareonthepacket.Onlyuse1pa
cketfor32ozofwater.Donotchangetheratio.Itcan
alsobeusedforotherhumidifierbrands.Thoroughly
rinsethebasewithtapwaterandmakesurenoEZCal
andEZCalProresiduesremainsinthebase!EZCaland
EZCalProareavailableatselectedretailstoresand
onlinewww.airoswiss.net.
Please check our website www.airoswiss.net
for further information.
AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland
33557-03
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Air-O-Swiss AOS 7142 Owner's manual

Category
Humidifiers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI