PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS U200
5
en
Instructions for use
6
en
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafe
placeforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Thisapplianceisnottobeusedbypersons(including
children)withimpairedphysical,sensoryormental
capacitiesorinsufficientexperienceandknowledge,
unlesstheyaresupervisedbysomeonewhoisrespon-
siblefortheirsafetyorgivenassistancewiththeuseof
thisappliance.Childrenshouldbesupervisedtoensure
thattheydonotplaywiththeappliance(fig.1).
• Useonlytheoriginaladapterprovidedforoperatingthe
unit.Theadapterprovidedmaynotbeusedforother
units.
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Onlyoperatetheappliancewhenitiscompletelyas-
sembled.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Donotpourwaterintothemistoutletoftheappli-
ance(5).
• Placethehumidifieronadry,levelsurface.
• Donotplacetheappliancedirectlyonthefloor,nextto
aheatingventorinthevicinityofelectricalequipment.
Ifthereleasedmistreachesthefloororobjectsbefore
ithasfullyevaporated,itmaycausedamagetothem(6).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotsubmergethemainbodyinwaterorother
liquids(28).
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Disconnectpowersupplybeforeservicing.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contamination-free,cold,freshtap
waterinyourhumidifier.Ifyourwatersourceiscontam-
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Whenfragrancingtheair,usethefragrancecontainer
provided(alsoseesection«Useoffragrances»).Donot
addanyadditivessuchasessentialoilsdirectlyintothe
watertankorthewaterbase(9).Theseadditiveswill
damageyourappliance!Appliancesthataredamaged
byadditivesareexcludedfromthewarranty.
• Theappliancedoesnothaveanintegratedhygrostat.
Useanexternalhygrostattoavoiddamagethrough
over-humidification.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
• Themanufacturerrejectsallliabilityfordamage
causedbynonobservanceoftheseinstructionsforuse.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
8
en
Proper use:
Theappliancemustonlybeusedforthehumidificationof
theairindoors.
Unpacking
• Carefullyremovetheunitfromitsbox.
• Removetheunitfromtheplasticbag(10).
• Removethedemineralizationcartridgeandtheadapter
fromthesmallcardboardbox.Openthesealedbagto
removethedemineralizationcartridge(11).
• Removethewatertankcapfromthewatertankand
screwthedemineralizationcartridgeontotheinsideof
thecap(12).
• Reviewtheinformationgivenontheratingplateabout
thepowersupply.
Foreword
CongratulationsonchoosingtheUltrasonicHumidifierU200!
Description of the appliance/
Scope of delivery
Nebulizerspace
Fragrancecontainer
On/Offswitch
forblueillumination
Adapter
Mistoutlet(rotating)
Evaporationchamber
HydroCell
Watertankhandle
Waterlevelindicator
Watertank
Brush
Demineralizationcartridge
Mainbody
Rotaryswitch
Watertankcap
Membrane
Receptacle
Fleecepad(forfragance)
Airinlet
10
12
11
9
en
14
Putting into operation
• Removetheplasticcoveroftheadapterandinsertthe
countryspecificplug(13).
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,
furniture,orotherobjects(14).Keepdistanceofat
least20inches(50cm).
• Soakthedemineralizationcartridgeinabowlofwater
foratleast24hoursbeforeusingit.Thegranuleshave
toabsorbwatertoreachmaximumperformance.Ifthe
cartridgeissoakedinthetank,makesuretoexchange
thewaterandemptythewaterfromthebasebefore
usingthehumidifier.
• Onaveragethedemineralizationcartridgeshouldbe
replacedevery2–3months.Thisintervalcanbe
shorterorlongerdependingonthehardnessofyour
water.Thecartridgemustbeexchangedatthelatest
after6monthsortheunitwillnotreachitsfull
performancecapability.See«Replacementofthe
demineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»forfilling
thewatertank.
• Placethewatertankontothebase(17).
• Connecttheadaptertotheunitandtheelectrical
socketandswitchontheunitusingtherotaryswitch
(18).
• Theappliancewillreachfullcapacityabout10to
15minutesafterbeingswitchedon.
• Makesurethatthepowercordisnotpinched
anywhere.Donotoperatetheapplianceifthecord
isdamaged(2).
13
Filling the tank
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebulizer
spacewhiletheapplianceisrunning!
Toprotecthealth safetyandproper humidi-
fier function use only clean, contamination-
free,cold,freshtapwaterinyourhumidifier.If
yourwatersourceiscontaminatedorifyouare
uncertainofitssafetyusedistilledwater.
Donotoperatetheappliancewhenthewatertankisempty!
Whenthewaterreachestheminimumlevel,theunitswit-
chesoffautomatically.
• Makesurethattherearenoforeignobjectsinsidethe
watertank.
• Removethewatertankcapfromthetank(15).Fillthe
tankwithclean,coldtapwater(16).Closethecapof
thewatertanksecurely!Placethewatertankontothe
base(17).Donotaddanyadditivestothewater!
• Connecttheadaptertotheunitandtheelectrical
socketandswitchontheunitusingtherotaryswitch
(18).Theemptyindicatorlightmaystayilluminatedfor
somesecondsuntilthebaseisfilledwithwater.
15
10
en
Water quality maintenance
TheHydroCellkeepshumidifiersoperatingattheirhighest
levelbetweenrecommendedcleanings.Goodforapproxi-
matelyonetotwomonths,dependingonthewaterquality,
theHydroCellensuresthehumidifier’sfunctionalitywhile
providing fresh humidification performance. It starts to
workassoonasitcomesintocontactwithwater,even
iftheunitisturnedoff.TheHydroCellshouldbechanged
everyonetotwomonths*.Lookatpicture19/20forthepo-
sitionoftheHydroCellinthewatertankoftheunit.Switch
offtheunitfirst.Contactyourlocalretaileror checkour
websitewww.airoswiss.netforreorderinformation.
*Dependingonthewaterquality.
18 21
19
17
16
22
20
11
en
Use of fragrances
Ontheoutsideofthemainbodyisafragrancecontainer
(21).Removethefragrancecontainerbypushingitbriefly.
Fragrancescanbedribbledontothefleecepadinthecon-
tainer.Afewdropsaresufficient–liquidmustnotbepresent
inthecontainer.Applyfragrancesonlyontothefleecepad
oracotton-woolpadandneveradddirectlytothecontai-
ner(22)!Wateradditives(e.g.ethericoils,fragrances,water
purifiers)mustNOTbeaddedtothewatertankordirectly
intothenebulizerspace!Evenasmallamountcandamage
theplasticofthesepartsorcreatecracks.Appliancesthat
aredamagedbyadditivesarenotcoveredbythewarranty.
Remove the fragrance container before emp-
tyingandcleaningtheappliance.
A) On-off switch and regulation of mist
output
Turningtherotaryswitchclockwiseswitchestheappliance
onandatthesametimeregulatesthemistoutputfrom
lowtohigh.
B) Water level indicator
Thewaterlevelindicatorclearlyshowshowmuchwateris
intheappliance.Theapplianceswitchesoffautomatically
whenthewatertankisempty.Thewaterlevelindicatorillu-
minatesred.Forfurtherinformationpleasereadthesection
«Fillingthetank».Afterinsertingthefulltank,itmaytakea
fewsecondsuntiltheredlightgoesout.
C) Switching blue illumination on/off
Theblueilluminationcanbeswitchedonandoffwiththe
slidingswitchonthebacksideofthemainbody.Thered
illuminationcannotbeswitchedoff.
Operation
12
en
Cleaning/Maintenance
Alwaysswitchtheapplianceoffbeforeremoving
thewatertank.Donotreachinsidethenebulizer
spacewhiletheapplianceisrunning!
EZCalandEZCalProaretheonlyrecommended
cleaninganddescalingsolutions. Do NOT use
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalandEZCalProwillvoidthewarranty.
Caution:watermustnotbeallowedtoenterthe
ventilationopening!Thiswilldamagetheappli-
ance(23).
Caution – risk of electric shock and
damage of the product!
• Switchtheapplianceoffandunplugtheadapterfrom
theappliance(24).
• Removethefragrancecontainerbypressingit
briefly(25).
• Cleanthewatertankandthenebulizerspaceregularly
onceaweek(26/31).
• UseEZCalandEZCalProcustomcleaninganddesca-
lingagentsonlytoremovedepositsfromthememb-
raneregularly(27).ThereisasampleofEZCalincluded
inthepackagingofyourhumidifier.Instructionsfor
usingareonthepacket.Onlyuse1packetfor32
ozofwater.Donotchangetheratio.DoNOTrunthe
unitwhenusingEZCalandEZCalPro.Thiscancause
damagetotheproductandvoidsthewarranty.Tho-
roughlyrinsethebasewithtapwaterafterusingEZCal
andEZCalProandmakesurenoEZCalandEZCalPro
residueremainsinthebase.
Removingthemistoutlet(28):useeitherthebrushor
aspoontoliftthemistoutletthroughtheopeningto
removeit.
Important
• Makesurethatnowatergetsintothelowerpartofthe
mainbody(29).
• Cleantheinnerpartswithasoftcloth.Neveruseany
solventsoraggressivecleaningagents(30).
• Onlyusethebrushtocleanthemembrane(31).This
shouldbedoneonceaweek.
• Changethewaterinthetankatleastevery3days.
14
en
Replacement of the demineralization
cartridge
Alwaysswitchofftheappliancebeforeremoving
thewatertank.Donotreachinsidethenebulizer
spacewhiletheapplianceisrunning!
The cartridge must be replaced every 2 – 3 months. If
the water is very hard, it may be necessary to replace
thecartridgeearlier.Whitedustaroundtheapplianceisa
suresignthatthecartridgeneedsreplacing.Ifwhiteresi-
duecontinuestoformaround theapplianceafteranew
cartridge has been inserted, please make sure that the
wateryouareusingisuntreated.Ifthewaterflowsthrough
adomesticwatersoftenersystembeforeitisusedinthe
unit,saltwillprecipitatearoundtheappliance.
Thedemi-
neralizationcartridgeorthegranulesmustbeexchangedat
thelatestafter6monthsortheunitdoesnotreachitsfull
performanceanymore.
Option A: Replace the granules
• Removethewatertankfromthebaseandunscrewthe
watertankcap(32).
• Thedemineralizationcartridgeisattachedtotheinside
ofthecap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(33).Important:doNOT
disposeofthetankcap!
• Openthecartridge(34).
•Throwthecontent(granules)intothewaste(35).Atten-
tion!Disposedgranulescanmakethefloorslippery!
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge(36).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(37).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(38).
•Turntheplasticcupandcartridgeoverandshakeuntil
allgranulesareinthecartridge(39).
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(40)andretainforfutureuse(the
refillresinconsistsof3refillbags)(41).
32
33 38
3934 35
36 37
15
en
46
40 45
41 42
43 44 47
• Closethecap(42).
• Soakthedemineralizationcartridgeinabowlofwater
foratleast24hoursbeforeuse(45).Thegranuleshave
toabsorbwatertoreachmaximumperformance.
• Nowscrewthecartridgeontothewatertankcap(46).
Closethetankcapsecurely!Placethewatertankonto
thebase(47).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: Replace the entire cartridge
• Removethewatertankfromthebaseandunscrewthe
watertankcap(32).
• Thedemineralizationcartridgeisattachedtotheinside
ofthetankcap.Unscrewthecartridgefromthecapby
turningitcounter-clockwise(33).Important:doNOT
disposeofthetankcap!
• Disposeoftheoldcartridge(43).
• Unpackthenewcartridge(44).
• Soakthenewcartridgeinabowlofwaterforatleast
24hoursbeforeuse(45).Thegranuleshavetoabsorb
watertoreachmaximumperformance.
• Nowscrewthecartridgeontothewatertankcap(46).
Closethetankcapsecurely!Placethewatertankonto
thebase(47).
16
en
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
TheAC/DCadapteriscUL-listed.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website
www.airoswiss.netforreorderinformation.
Customer Service
CustomerService(USA)1-800-336-0326
www.airoswiss.net
Problem Possible cause What to do
Unitdoesnotoperate Appliancehasnopower Connectappliancetopowersocket
Nowaterinthetank Filltankwithwater
(Redwaterlevelindicatorisilluminated)
Nomistoutput Mistoutputsettingtoolow Increasemistoutput
 Residueofcleaningagent Rinsewithclearwater
Demineralizationcartridgeisclogged Remove2-3teaspoonsofgranulesfromthe
cartridgeanddisposeofthem.
Soakcartridgeinwaterfor24hours
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum.The
appliancewillworkproperlyagain
after10minutes.
Mineraldepositsonmembrane Cleanmembrane
Whitedepositaroundthe Demineralizationcartridgeexhausted Replacedemineralizationcartridgeorgranules
appliance Usedgranulesmustgoinwaste
Troubleshooting
Technical data
Electricalvoltage 100–240V/50-60Hz
Powerconsumptionupto 20W
Humidityoutputupto 1.8gallons/24h(6.8L/24h)
Suitableforroomsupto 430sqft(40m
2
)
Dimensions(LxWxH) 9.5x4.7x10.4inches
(24x12x26.3cm)
Weight(empty) 4lbs(1.8kg)
Operatingnoiselevel <25dB(A)
Accessories 7531Demineralizationcartridge
HydroCellA200
 EZCalA7417
EZCalProA100
17
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleavingen-
oughmoisturefortheair.Ifthewindowisleftopen,
thenthisallowsmoisturetoescapetheroom.Ano-
therfactorisalotoftimestheunitisplacednextto
aheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects
(dryoutandeventuallycracksappear),discomfort,
sickness,anddriesoutnasalmembranes.
Over-humidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefree-standingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thesedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfromthebaseand
thewatertank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization
cartridge (DMC)?
A.TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobe
soakedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverse-osmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis
18
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter1-2
monthswhenyouuseveryhardwater(forsofterwater
after2-3months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapre-installedwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi-
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverse-Osmosiswater(R-Owater)insteadofdis-
tilledwaterandremovethedemineralizationcartridge.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimatic
conditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchanged
severaltimesperday–thehumidifierneedstostarts
itsworkfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–high-risebuil-
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan
2timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunit-ifitisplacedclosetoadoor,
windoworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailerwheretheunit
waspurchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnot
flashingyoumighthavesetthedesiredhumiditytoo
lowandthecurrenthumiditylevelintheroomis
higher.Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after2-3months,inareaswithhardwaterexchange
thecartridgeafter1-2months.However,thedemi-
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.
Q.Water tank cap is too tight to unscrew
A. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthe
watertankcaptoreleaseairfromthewatertank.
Continuetodothisuntilyouareabletounscrewthe
watertankcap.
Q.Unit is running intermittently.
A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If2-3monthshavepassed,
itistimetoreplacethecontentsofthecartridge.
Howeverthedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6
monthsortheunitdoesnotreachitsfullperformance
anymore.
•Ifthecontentsofthecartridgewerejustreplacedthere
areprobablytoomanygranulesinthecartridge.Re-
move2tablespoonsofgranulesfromthecartridge.
19
en
Accessories
Q.Do I need to keep any parts before I replace the
demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiece
thatattachesthedemineralizationcartridgetothe
watertank).
Q.What is the Hydro Cell and how long is it good for?
A. TheHydroCellkeepshumidifiersoperatingattheir
highestlevelbetweenrecommendedcleanings.Good
forapproximatelyonetotwomonths,dependingonthe
waterquality,theHydroCellensuresthehumidifier’s
functionalitywhileprovidingfreshhumidification
performance.Itneedstobereplacedeveryonetotwo
months*.
*Dependingonthewaterquality.
Q.Placement of the Hydro Cell
A.Pleaseseepicture19/20forinstructions.
Q.What is EZCal and EZCal Pro?
A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalandEZCalProare
usedforcleaninganddescalinganyofthehumidifiers
andcleansmineralbuild-up.EZCalandEZCalProare
theonlyrecommendedcleaninganddescalingsolu-
tions.DoNOTuseanyothercleaningsolutionssinceit
candamagetheproduct.Anyuseofcleaningsolutions
apartfromEZCalandEZCalProwillvoidthewarranty.
Instructionsforusingareonthepacket.Onlyuse1pa-
cketfor32ozofwater.Donotchangetheratio.Itcan
alsobeusedforotherhumidifierbrands.Thoroughly
rinsethebasewithtapwaterandmakesurenoEZCal
andEZCalProresiduesremainsinthebase!EZCaland
EZCalProareavailableatselectedretailstoresand
onlinewww.airoswiss.net.
Please check our website www.airoswiss.net
for further information.
AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland
38276-01
/