Magnescale LY72 Owner's manual

Type
Owner's manual

Magnescale LY72 is a versatile and precise digital readout that offers a wide range of features for various measurement applications. With its advanced display resolution capabilities, you can customize the unit and decimal place settings to suit your specific needs.

The LY72 allows you to toggle between different display modes, including length, angle, and diameter, providing flexibility for various measurement tasks. It also features a polarity reversal function, enabling you to change the counting direction as required.

Furthermore, the LY72 offers the option to change the display resolution independently for each input axis. This allows you to optimize the readout for different measurement units and scales, ensuring accurate and consistent readings.

Magnescale LY72 is a versatile and precise digital readout that offers a wide range of features for various measurement applications. With its advanced display resolution capabilities, you can customize the unit and decimal place settings to suit your specific needs.

The LY72 allows you to toggle between different display modes, including length, angle, and diameter, providing flexibility for various measurement tasks. It also features a polarity reversal function, enabling you to change the counting direction as required.

Furthermore, the LY72 offers the option to change the display resolution independently for each input axis. This allows you to optimize the readout for different measurement units and scales, ensuring accurate and consistent readings.

LY72 Change of display resolution (polarity) 1/2
When the display is , press key three times.
When the display is , press key twice..
The display will be . (Measurement unit disassembly)
Ver.1 (2021.1) CS&S
Purpose of change Operation Explanation
Change the measurement unit
resolution
Change the length measurement unit resolution
in the basic settings. And check the display
resolution in the detailed settings.
Change the display resolution Change the display resolution in the detailed
settings
Change the display polarity
(Counting direction is reversed)
Change the display resolution in the detailed
settings
Diameter display (double count value) Change to diameter display with display
resolution in the detailed settings
Basic settings Input axis Change
Input 1
Input 2
LY72
When ABC is selected
in the label setting
Input 3
LY72 Change of display resolution (polarity)
The operation method for changing the display resolution differs depending on the purpose and conditions of the change.
Select the purpose and conditions to be changed from the table below and perform the operation.
Advanced Settings Display resolution Change
Advanced Settings Display resolution Change polarity
Basic settings Input axis Change
Advanced Settings Display resolution Diameter display
* If you do not know the output resolution of the measurement unit, refer to the separate "Initial setup manual".
Power ON About 2 sec
Set to basic settings mode.
Turn key “ON” while the AC adapter is energized.
Press and hold key for 3 seconds after the lamp changes from blinking to off.
Press key once to automatically switch to advanced settings mode.
The display will be .
Press key, the display becomes the normal display.
Switch from basic settings to normal count mode.
Press key once and the display will change to .
Press key once and the display will change to .
Press key of the axis you want to change and select
the measurement unit resolution.
When you have made your selection, press key to save your settings.
Press key of the axis you want to change and select
the measurement unit resolution.
When you have made your selection, press key to save your settings.
Display example when inputting 3 axes
Standard Expansion
Extended key
Selection of measurement
unit resolution
When XYZ is selected
in the label setting
LY72 Change of display resolution (polarity) 2/2
Advanced Settings Display resolution Change polarity
Advanced Settings Display resolution Change
Advanced Settings Display resolution Diameter display
Diameter display
Press key once to get the display resolution of each axis.
Press key of the axis you want to change to the diameter display and turn on the lamp.
If the resolution changes, press key again.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Set to advanced settings mode.
Press key in normal count mode
The display will be .
Press key once to display .
Set to advanced settings mode.
Press key in normal count mode
The display will be .
Press key once to display .
Press key once to get the display resolution of each axis.
Press key for the axis for which you want to change the polarity,
and then press key.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Set to advanced settings mode.
Press key in normal count mode
The display will be .
Press key once to display .
Press key once to display the display resolution of each axis.
Press key of the axis you want to change and select the resolution.
Please note that the lamp lights up once every two times
and the diameter display is set.
When you have made your selection, press key to save your settings.
Press key to return to the normal counting state.
Angle display
Length display
NOTE 1: Selection of a value smaller than the basic settings measurement unit
resolution is not displayed.
NOTE 2: The angle display can be set when the angle resolution is selected in
the basic settings.
NOTE 1 NOTE 2
Selection of display resolution
Expansion
Extended key
Before After
Change polarity
Example of changing the polarity of the display in the middle row
  • Page 1 1
  • Page 2 2

Magnescale LY72 Owner's manual

Type
Owner's manual

Magnescale LY72 is a versatile and precise digital readout that offers a wide range of features for various measurement applications. With its advanced display resolution capabilities, you can customize the unit and decimal place settings to suit your specific needs.

The LY72 allows you to toggle between different display modes, including length, angle, and diameter, providing flexibility for various measurement tasks. It also features a polarity reversal function, enabling you to change the counting direction as required.

Furthermore, the LY72 offers the option to change the display resolution independently for each input axis. This allows you to optimize the readout for different measurement units and scales, ensuring accurate and consistent readings.

Ask a question and I''ll find the answer in the document