  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM290/IX Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How do I ignite the burners on my Whirlpool AKM290/IX cooktop?
    What should I do if the burner fails to ignite?
    Does the Whirlpool AKM290/IX cooktop have a safety system?
    What is the rated heat capacity for a natural gas (Methane) G20 cooktop?
    What is the total rated heat capacity for an LPG (Cylinder) G30 or G31 cooktop?
AKM 290 PRODUCT DESCRIPTION SHEET
DE
5019 319 01394
Operation of burners
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame setting .
At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
If the burner fails to light, repeat the above steps.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety system serves to prevent the
emission of gas if the flame should be
extinguished accidentally (draughts,
interruptions in gas supply, dousing with liquids,
etc.).
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded
circle
Tap closed
Large flame Maximum opening/ delivery
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CAT.
11
2ELL3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Typ e o f g as us e d Typ e o f
burner
Injector
marking
Rated
heat
capacity
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
large
medium
small
Y 115
H2 98
X 72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Methane) G25
large
medium
small
F3 134
Y 98
F1 77
3.00
1.65
1.00
332 l/h
183 l/h
111 l/h
0.60
0.35
0.30
18 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G30
large
medium
small
S 75
M 57
H2 45
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.85
0.52
0.46
42.5 50 57.5
LIQUID
PETROLEUM GAS
(Cylinder) G31
large
medium
small
S 75
M 57
H2 45
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.85
0.52
0.46
42.5 50 57.5
Type of gas used Appliance
model
Total rated heat
capacity
kW
Total rated
consumption
Air necessary (m
3
) for
the combustion of 1 m
3
of gas
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G25 25 mbar 4 gas 7.30 809 l/h 8.187
G30 50 mbar 4 gas 7.30 531 g/h 30.94