IKEA HB G15 S Program Chart

Type
Program Chart

IKEA HB G15 S is a gas cooktop with four burners of different sizes, allowing you to cook various dishes simultaneously. The large burner is suitable for large pots, while the medium and small burners can accommodate smaller pans and cookware. The cooktop features an electric ignition system that generates a spark to ignite the burners, eliminating the need for matches or lighters. Additionally, the cooktop is equipped with a safety system that prevents gas emission if the flame accidentally extinguishes.

IKEA HB G15 S is a gas cooktop with four burners of different sizes, allowing you to cook various dishes simultaneously. The large burner is suitable for large pots, while the medium and small burners can accommodate smaller pans and cookware. The cooktop features an electric ignition system that generates a spark to ignite the burners, eliminating the need for matches or lighters. Additionally, the cooktop is equipped with a safety system that prevents gas emission if the flame accidentally extinguishes.

FRAMTID HGA4K PRODUCT DESCRIPTION SHEET
CZ SK RU
5019 619 01346
HB G15
Operation of burners
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame setting .
At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
If the burner fails to light, repeat the above steps.
Note:
Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat
the operation with the knob turned to the
small flame setting .
The burner safety system serves to prevent the
emission of gas if the flame should be extinguished
accidentally (draughts, interruptions in gas supply,
dousing with liquids, etc.).
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed
Large flame
Maximum opening/
delivery
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CAT. II2H3B/P
Eletric Supply: 230 V ~ 50 Hz
Type of gas used Type of
burner
Injector
marking
Nominal
heating
capacity
kW
Nominal
consumption
Reduced
heat capacity
kW
Gas Pressure
(mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
large
medium
small
Y 115
H2 98
X 72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G30
large
medium
small
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
25 30 35
LIQUID
PETROLEUM GAS
(Cylinder) G31
large
medium
small
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
25 30 35
Type of gas used Appliance
model
Nominal heating
capacity
kW
Total nominal
consumption
Air necessary ( m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G30 30 mbar 4 gas 7.30 531 g/h 30.94
G31 30 mbar 4 gas 7.30 531 g/h 30.94
IKEA of Sweden AB
SE - 343 81 Älmhult
  • Page 1 1
  • Page 2 2

IKEA HB G15 S Program Chart

Type
Program Chart

IKEA HB G15 S is a gas cooktop with four burners of different sizes, allowing you to cook various dishes simultaneously. The large burner is suitable for large pots, while the medium and small burners can accommodate smaller pans and cookware. The cooktop features an electric ignition system that generates a spark to ignite the burners, eliminating the need for matches or lighters. Additionally, the cooktop is equipped with a safety system that prevents gas emission if the flame accidentally extinguishes.