PR LED Studio 3500T User manual

Category
Floodlights
Type
User manual

This manual is also suitable for

LED Studio 3500D
LED Studio 3500T
PR-3500D
PR-3500T
This product manual contains important information about the safe installation and use of this lighting fixture.
Please read and follow these instructions carefully and keep this manual in a safe place for future reference.
PR LIGHTING LTD.
http://www.pr-lighting.com
2/12
INDEX
SAFE USAGE OF THE LIGHTING FIXTURE
3
INSTALLING THE LIGHTING FIXTURE
4
CONTROL SYSTEM AND POWER CONNECTIONS
4
DMX TERMINATOR
5
SETUP OPTIONS- LIGHTING FIXTURE CONFIGURATION
6
TO SET THE DMX START ADDRESS
6
OPERATION MENU
7
DMX PROTOCOL
7
INDICATION OF LED DISPLAY
7
MAINTENANCE
8
TROUBLESHOOTING
8
TECHNICAL DATA
9
ELECTRICAL DIAGRAM
10
COMPONENT ORDER CODES
11
Please note that as part of our ongoing commitment to continuous product development, specifications are subject to change without notice. Whilst
every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improvement. The
publishers cannot be held responsible for the accuracy of the information herein, or any consequence arising from them.
Every unit is tested completely and packed properly by the manufacturer. Please make sure the packing and / or the unit are in good condition
before installation and use. Should there be any damage caused by transportation, consult your dealer and do not use the unit. Any damage caused
by improper use will not be assumed by the manufacturer and / or dealer.
ACCESSORIES
These items are packed together with the lighting fixture
Name Quantity Unit Remark
Clamp 2 Pcs
Safety cord 2 Pcs
5-pin XLR Plug(Female) 1 Pc
5-pin XLR Plug(male) 1 Pc
User’s Manual 1 pc
SAFE USAGE OF THE LIGHTING FIXTURE
When unpacking and before disposing of the carton, check there is no transportation damage before using the lighting fixture.
there
be any damage caused by transportation, consult your dealer and do not use the apparatus.
The lighting fixture can be only used indoors, IP20.
The lighting fixture is not designed or intended to be mounted directly on to inflammable surfaces.
The
lighting fixture is only intended for installation, operation and maintenance by qualified personnel.
Do not project the beam onto inflammable surfaces, minimum distance is
Avoid direct exposure to the light from the lamp. The light is harmful to eyes.
Do not attempt to dismantle and/or modify the lighting fixture in any way.
Electrical connection must only be carried out by qualified personnel.
Before installation,
ensure that the voltage and frequency of power supply match the power requirements of the lighting fixture.
It is essential that each lighting fixture is correctly earthed and that electrical installation conforms to all relevant sta
Do not conne
ct this device to any other types of dimmer apparatus.
Make sure that the power-
cord is never crimped or damaged by sharp edges. Never let the
Only handle the power-
cord by the plug. Never pull out the plug
When the lighting fixture is hanged to a high place, please use a safety cord provided to pass through the lighting fixtures
secondary safety fixing for safety seasons. For details, refer toINSTALL THE LIGHTING
Exterior surface temperatures of the lighting fixture after 5 minutes operation is 45
There is no user serviceable parts inside the lighting fixture, do not open the housing and never operate
covers removed.
If you have any questions, dont hesitate to consult your dealer or manufacturer.
Always disconnect the fixture
3/12
SAFE USAGE OF THE LIGHTING FIXTURE
When unpacking and before disposing of the carton, check there is no transportation damage before using the lighting fixture.
be any damage caused by transportation, consult your dealer and do not use the apparatus.
The lighting fixture can be only used indoors, IP20.
The lighting fixture is not designed or intended to be mounted directly on to inflammable surfaces.
lighting fixture is only intended for installation, operation and maintenance by qualified personnel.
Do not project the beam onto inflammable surfaces, minimum distance is
2m. 2m
Avoid direct exposure to the light from the lamp. The light is harmful to eyes.
Do not attempt to dismantle and/or modify the lighting fixture in any way.
Electrical connection must only be carried out by qualified personnel.
ensure that the voltage and frequency of power supply match the power requirements of the lighting fixture.
It is essential that each lighting fixture is correctly earthed and that electrical installation conforms to all relevant sta
ct this device to any other types of dimmer apparatus.
cord is never crimped or damaged by sharp edges. Never let the
power-
cord come into contact with other cables.
cord by the plug. Never pull out the plug
by tugging the power-cord.
When the lighting fixture is hanged to a high place, please use a safety cord provided to pass through the lighting fixtures
secondary safety fixing for safety seasons. For details, refer toINSTALL THE LIGHTING
FIXTUREsection.
Exterior surface temperatures of the lighting fixture after 5 minutes operation is 45
, when achieving steady state it is
There is no user serviceable parts inside the lighting fixture, do not open the housing and never operate
the lighting fixture with the
If you have any questions, dont hesitate to consult your dealer or manufacturer.
from power, before
installation, cleaning and
any maintenance work !
When unpacking and before disposing of the carton, check there is no transportation damage before using the lighting fixture.
Should
ensure that the voltage and frequency of power supply match the power requirements of the lighting fixture.
It is essential that each lighting fixture is correctly earthed and that electrical installation conforms to all relevant sta
ndards.
cord come into contact with other cables.
When the lighting fixture is hanged to a high place, please use a safety cord provided to pass through the lighting fixtures
handles as a
FIXTUREsection.
, when achieving steady state it is
65.
the lighting fixture with the
any maintenance work !
4/12
INSTALL THE LIGHTING FIXTURE
When the lighting fixture is used, as the right figure above, unfold the support to certain angle and put the lighting fixture onto a
flat surface. Make sure it is steady.
When the lighting fixture is used at a high place, as the left figure above, fold the support, turn it round to the top of the lighting
fixture, connect a lamp hook to the mounting hole reserved in the support by screws, and then hang the hook to a high place.
Eventually, use the safety cord provided to pass through the handles and hang it as a second safety fixing.
CONTROL SYSTEM AND POWER CONNECTION
Connection between the controller and a lighting fixture and between one lighting fixture and another must be made with a 2
core-screened cable, with each core having at least a 0.5mm diameter. Please use the lighting fixtures cannon 5- pin signal input and
output cables as connection. The 5-pin signal connections are connected as shown in the figure above.
Note: Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. The body of the plug is not
connected in any way. The device accepts digital control signals in protocol DMX512 (1990).
As for power connections, each lighting fixture has to be supplied separately by external power. Use the power cord of each lighting
fixture to connect the mains power directly, making sure the voltage and frequency marked on the panel of the lighting fixture match
what is supplied.
5/12
The connections are as the figure below.
DMX TERMINATOR
In the Controller mode, at the last fixture in the chain, the DMX output has to be connected with a DMX terminator. This prevents
electrical noise from disturbing and corrupting the DMX control signals.
The DMX terminator is simply an XLR connector with a 120 (ohm) resistor connected across pins 2 and 3, which is then plugged
into the output socket on the last lighting fixture in the chain. The connections are illustrated below.
6/12
SETUP OPTIONS-LIGHTING FIXTURE CONFIGURATION
To browse through or change a fixtures configuration, after
ENTER button has been
pressed for about 3 seconds, the display of
AddR means the entrance of the menu. To set or browse through a fixture’s settings, press buttons of UP and DOWN. After
button ENTER is pressed, a sub-menu is entered showing current parameters while indication flashing.
Press button UP or
DOWN to change values(plus or minus)
Press button
ENTER
to save your settings or enter into the upper level menu and the indication stops from flashing.
Press
FUNC to enter into the upper level menu(parameters not saved )or browse through the upper level menu.
After FUNC is pressed for more than 1second or buttons not pressed for more than 1 minute, it will go back to the main menu
displaying the fixtures name.
After the exit of the menus, the current lamp color will be shown.
While DMX signals are available, Signal LED indication will be on, otherwise off..
TO SET THE DMX START ADDRESS
Each device must be given a DMX start address so that the correct lighting fixture responds to the correct control signals. This DMX
start address is the channel number from which the lighting fixture starts to listen to the digital control information being sent out
from the controller. The device has Two Channel Modes. 1 Channel Mode has 1 channel, so set the No. 1 lighting fixtures address
001, No. 2 lighting fixtures address 002, No. 3 lighting fixtures address 003, and so on. 4 Channel Mode has 4 channels, so set the No.
1 lighting fixture’s address 001, No. 2 lighting fixtures address 005, No. 3 lighting fixtures address 009, and so on.
Launch the lighting fixture. Press button ENTER for more than 3 seconds to unlock the panel till
is displayed
.
Press button FUNC, UP or DOWN to find menu.
Then press ENTER to show DMX address and press UP or DOWN to set DMX address.
At this time, the address will flash continuously. Press button ENTER to confirm and it means the setting has been
enabled and saved. After powered next time, the latest setting will be used.
Press button FUNC, it will return to the upper menu one by one.
7/12
DMX PROTOCOL
1 Channel Mode
Channel FUNCTION DMX DESCRIPTION
1 Dimmer 000-255 Dimming
4 Channel Mode
Channel
FUNCTION
DMX
DESCRIPTION
1 The first part Dimmer 000-255 Dimming
2 The second part Dimmer 000-255 Dimming
3 The third part Dimmer 000-255 Dimming
4 The forth part Dimmer 000-255 Dimming
INDICATION OF LED CHARACTER
DMX Indication
On DMX signal OK
Off No DMX signal
8/12
MAINTENANCE
To prolong the life of the lighting fixture, it is very important to do the maintenance work. Cooling fans must be cleaned once every
15days and external lens cleaned periodically for an optimum light output. DO NOT USE ANY SOLVENT CONTAINING
CHEMICAL ELEMENT.
Cleaning frequency depends on the environment in which the fixture operates. Soft cloth and typical glass cleaning products should be
used for cleaning with care. It is recommended to clean lighting fixture at least once every 20 days.
Do not use any organic solvent, e.g. alcohol, to clean housing of the apparatus.
TROUBLESHOOTING
PROBLEM ACTION
The lighting fixture doesn’t switch on
Power connection is not correct.
Power supply is damaged or abnormal. Call a qualified personnel to fix
it.
Connection of control board is not correct. Call a qualified personnel to
fix it.
The lighting fixture can be turned on, but LEDs
do not emit light and are out of control.
Connection of LED board is not correct. Call a qualified personnel to fix
it.
The lamp comes on but the lighting fixture
doesnt respond to the controller
Make sure that the lighting fixtures Start Address is properly set.
Replace or repair the XLR signal cable.
The beam appears dim The lighting fixture is too hot. Take ventilation measures to make it cool.
9/12
TECHNICAL DATA
VOLTAGES:
100-240V AC50/60Hz
POWER CONSUMPTION:
120W@220V
LED Light sources :
Quantity 12 pcs(10Wx12)
Manufacturers Rated LED Life 50000 Hours
DIMMER:
0-100% linearly adjustable
COLOR TEMPERATURE
PR-3500T 3200K
PR-3500D 5600K
CRI
Ra86
Luminous Flux
5000 lm
LIGHT ANGLE
Field Angle(
1/10 Maximum) θ 0°~80°
CONTROL:
DMX512, 5 pin interfaces
Two
Channel Modes:
1 CH,1
Channel;4CH,4 Channels.
HOUSING:
Extruding aluminum, IP20
WORK ENVIRONMENT TEMPERATURE:
-20°C~40°C
WEIGHT:
Net weight: 4.2kg
Gross weight: 6.8 kg
10/12
SIZES:
300±20
300±20
185
80
1800
Electrical Diagram
11/12
COMPONENT ORDER CODES
NAME PART NO. QUANTITY REMARK
Power Switch
192010134
1
10W LED White
150020255
1
2
CT3200K for PR
-
3
5
00T
10W LED White
15002025
2
1
2
CT5500K for PR
-
3
5
00D
PR-3500 Control Board(W)
230060
309
1
12/12
PR LIGHTING LTD.
PR New Hi-tech Science Park, 1582 Xingye Avenue
Nancun Panyu, Guangzhou, 511442 China
TEL: +86-20-3995 2888
FAX: +86-20-3995 2330
P/N: 320020125A
Version:20140711
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

PR LED Studio 3500T User manual

Category
Floodlights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI