Scott Safety 2216 PSI Operating & Maintenance Instructions

Type
Operating & Maintenance Instructions

This manual is also suitable for

Page 1 of 32 P/N 89332-01 Rev F 7/11
© 2011 Scott Safety
SCOTT, the SCOTT SAFETY Logo, Scott Health and Safety, ISCBA, AV-2000, AV-3000, SureSeal, Scott-O-Vista, and Weld-
O-Vista are registered and/or unregistered marks of Scott Technologies, Inc. or its afliates.
SCOTT ISCBA
INDUSTRIAL SELF-CONTAINED BREATHING APPARATUS
MODEL 2216 ISCBA RESPIRATOR (2216 PSI)
MODEL 4500 ISCBA RESPIRATOR (4500 PSI)
OPERATING & MAINTENANCE INSTRUCTIONS
WARNING
IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN SERIOUS INJURY OR DEATH.
IMPROPER USE INCLUDES, BUT IS NOT LIMITED TO, USE WITHOUT ADEQUATE TRAINING,
DISREGARD OF THE WARNINGS AND INSTRUCTIONS CONTAINED HEREIN, AND FAILURE
TO INSPECT AND MAINTAIN THIS RESPIRATOR.
THIS RESPIRATOR IS INTENDED TO BE USED ONLY IN CONJUNCTION WITH AN ORGANIZED
RESPIRATORY PROTECTION PROGRAM WHICH COMPLIES WITH THE REQUIREMENTS OF
“PRACTICES FOR RESPIRATORY PROTECTION”, Z88.2 AVAILABLE FROM AMERICAN NA-
TIONAL STANDARDS INSTITUTE INC., 1430 BROADWAY, NEW YORK, N.Y., 10018, OR THE
REQUIREMENTS OF OSHA SAFETY AND HEALTH STANDARD 29 CFR 1910 PARAGRAPH 134
AVAILABLE FROM THE U.S. DEPARTMENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION, OR OTHER PERTINENT NATIONALLY RECOGNIZED STANDARDS.
For Use With 2216 PSI Cylinders of
30 Minute Rated Duration
PRESSURE REDUCER
HOSE COUPLING (UN-
ATTACHED)
OPTIONAL
EBSS HOSE
CYLINDER
LATCH
TRI-SLIDE
BUCKLE
SHOULDER
STRAPS
GAUGE WITH
PROTECTOR
WAIST BELT
RELEASE
BUCKLE
REGULATOR
QUICK DIS-
CONNECT
REGULATOR
HOLDER
TYPICAL INDUSTRIAL SCBA 2216 PSI
W/ OPTIONAL ACCESSORIES
CYLINDER AND
VALVE ASSEMBLY
MODEL 2216 ISCBA RESPIRATOR
(2216 PSI)
For Use With 4500 PSI Cylinders of
30, 45, or 60 Minute Rated Duration
PRESSURE REDUCER
HOSE COUPLING (AT-
TACHED)
CYLINDER
LATCH
TRI-SLIDE
BUCKLE
WAIST BELT
RELEASE
BUCKLE
REGULATOR
QUICK DIS-
CONNECT
REGULATOR
HOLDER
CYLINDER AND
VALVE ASSEMBLY
TYPICAL INDUSTRIAL SCBA 4500 PSI
W/ OPTIONAL ACCESSORIES
MODEL 4500 ISCBA RESPIRATOR
(4500 PSI)
HIP
PADS
SHOULDER
STRAPS
HIP
PADS
GAUGE WITH
PROTECTOR
OPTIONAL
EBSS HOSE
Page 2 of 32
P/N 89332-01 Rev F 7/11
WARNING
CERTAIN ENVIRONMENTS MAY REQUIRE
THAT PROTECTIVE MATERIAL COVER SOME
OR ALL OF THE RESPIRATOR IN ADDITION TO
COVERING THE USER. THE USER MUST BE
ABLE TO ACCESS THE CONTROLS OF THE
RESPIRATOR AT ALL TIMES. INABILITY TO
ACCESS CONTROLS OF THE RESPIRATOR
WHEN THE RESPIRATOR IS NEEDED FOR
ESCAPE MAY RESULT IN SERIOUS INJURY
OR DEATH.
WARNING
DO NOT USE THIS RESPIRATOR FOR FIRE
FIGHTING. USE OF THIS EQUIPMENT FOR
FIRE FIGHTING MAY RESULT IN FAILURE
OF THE EQUIPMENT WHICH COULD CAUSE
SERIOUS INJURY OR DEATH.
GENERAL DESCRIPTION
The SCOTT Industrial Self-Contained Breathing Apparatus (ISCBA)
is a respirator designed to supply breathable air and respiratory pro-
tection to personnel while performing work in objectionable, oxygen
deficient and/or unbreathable (toxic) atmospheres. Model 2216 ISCBA
respirator uses a 2216 psi cylinder while Model 4500 ISCBA respira-
tor uses a 4500 psi cylinder.
This respirator is to be used only by persons trained in the use of
the respirator and only in conjunction with an organized respiratory
protection program. This respirator is not to be used under water, for
interior structural fire fighting or for any other purpose not authorized
by the organized respiratory protection program that applies specifi-
cally to the user.
The respirator consists of a cylinder and valve assembly for storing
compressed breathing air, a harness and backframe assembly to sup-
port the equipment on the body of the wearer, a single stage pressure
reducer mounted on the backframe, a positive pressure facepiece-
mounted breathing regulator, and a facepiece assembly.
The pressure reducer has an integral bell alarm to warn the user of
diminishing air supply.
The ISCBA respirator is supplied with a steel wire frame fitted with
a waist strap assembly, shoulder straps, and side straps. The straps
are available either in nylon or flame resistant Kevlar1 material.
The breathing regulator is equipped with an air saver/donning switch
which can be activated to prevent rapid loss of air supply if the sys-
tem is turned on prior to donning the facepiece or if the facepiece is
removed while the cylinder valve is open. Respirators are available
with or without a quick disconnect in the hose to the mask-mounted
breathing regulator.
1Kevlar is a registered trademark of E.I. du Pont de Nemours, Inc.
TYPICAL INDUSTRIAL SCBA
(4500 PSI MODEL SHOWN)
FRONT VIEW LEFT SIDE VIEW
PRESSURE
REDUCER
BELL
ALARM
PURGE
VALVE
CYLINDER
VALVE
BUCKLE
RELEASE
LEVER
AIR SAVER
SWITCH
REMOTE
PRESSURE
GAUGE
FACEPIECE
SHOULDER
STRAP
BUCKLE
SIDE RELEASE
BUCKLE
HEAD HARNESS
FIGURE 1
WARNING
THIS RESPIRATOR PROVIDES PROTECTION
ONLY TO THE USER’S RESPIRATORY
SYSTEM AND TO PART OF THE FACE.
IF THE HAZARDOUS ATMOSPHERE
CONTAINS TOXINS OR CONTAMINANTS
WHICH MAY POISON THROUGH THE SKIN,
ADDITIONAL PROTECTIVE EQUIPMENT
MAY BE REQUIRED. FAILURE TO PROVIDE
ADEQUATE PROTECTIVE EQUIPMENT FOR
THE HAZARDS IN THE WORKPLACE MAY
RESULT IN SERIOUS INJURY OR DEATH.
WARNING
DO NOT OPERATE THIS EQUIPMENT
WHILE UNDER THE INFLUENCE OF
DRUGS, ALCOHOL, OR ANY MEDICATIONS
OR SUBSTANCES WHICH MAY AFFECT
VISION, DEXTERITY, OR JUDGMENT. USERS
OF THIS EQUIPMENT MUST BE IN GOOD
PHYSICAL AND MENTAL HEALTH IN ORDER
TO OPERATE SAFELY. DO NOT USE THIS
EQUIPMENT WHEN FATIGUE PREVENTS
SAFE OPERATION. STAY ALERT WHEN
OPERATING THIS EQUIPMENT. INATTENTION
OR CARELESSNESS WHILE OPERATING
THIS EQUIPMENT MAY RESULT IN SERIOUS
INJURY OR DEATH.
Page 3 of 32 P/N 89332-01 Rev F 7/11
WARNING
RESPIRATORS SHALL NOT BE WORN WHEN
CONDITIONS PREVENT A GOOD FACE SEAL.
SUCH CONDITIONS MAY INCLUDE, BUT ARE
NOT LIMITED TO, GROWTH OF BEARDS,
SIDEBURNS, A SKULL CAP THAT PROJECTS
UNDER THE FACEPIECE OR TEMPLE PIECES
ON EYEGLASSES. ALSO, ABSENCE OF ONE
OR BOTH DENTURES CAN SERIOUSLY
AFFECT THE FIT OF A FACEPIECE. ANY
CONDITION WHICH PREVENTS A GOOD
FACE SEAL MAY PERMIT EXPOSURE TO
THE HAZARDOUS ATMOSPHERE WHICH MAY
RESULT IN SERIOUS INJURY OR DEATH.
WARNING
DO NOT USE THE BLACK POLYESTER
HEAD HARNESS OR NYLON BACKFRAME
HARNESS WHEN ACCIDENTAL EXPOSURE
TO HIGH HEAT OR FLAME IS A POSSIBILITY.
IN THOSE CIRCUMSTANCES, THE
POLYESTER OR NYLON MAY MELT OR BURN
CAUSING INJURY OR MAY INTERFERE WITH
RESPIRATORY PROTECTION RESULTING IN
SERIOUS INJURY OR DEATH.
The facepiece utilized on this respirator is available in a variety of
sizes and configurations for standard use or special applications. The
facepiece may be readily detached from the breathing regulator to
allow for utilization of the best fitting and most comfortable size face-
piece for an individual user. Fit testing per OSHA Standard 29 CFR
Part 1910 or ANSI Standard Z88.2 requires testing in the negative
pressure mode using equipment such as a Portacount Plus2 Respira-
tor Fit Tester. For this, SCOTT facepieces require use of SCOTT Fit
Test Adapter P/N 804057-01 or equivalent and appropriate negative
pressure testing equipment. Mask Seal Kit P/N 805655-01 may also
be required to attain a proper fit. Head harnesses are available in
several materials including polyester and Kevlar1. Each size facepiece
may be equipped with a lens kit if the use of corrective spectacles is
required. See ACCESSORIES Section for facepiece options.
The duration of the respirator may be extended by use of a low pres-
sure airline air supply. (For details see ACCESSORIES Section.) The
respirators are National Institute for Occupational Safety and Health
(NIOSH) approved for use in temperatures to -25 °F / -32 °C.
Depending on the cylinder and valve used, the respirators are ap-
proved and maintained under NIOSH approval numbers listed on the
NIOSH APPROVAL LABEL. These respirators meet the requirements
of Title 42, Part 84 of the Code of Federal Regulations when used
and maintained in accordance with these instructions and the NIOSH
label located on the harness and backframe assemblies. A complete
NIOSH APPROVAL LABEL is included with these instructions.
For assistance, contact your SCOTT authorized distributor or call
SCOTT Safety at 1-800-247-7257.
2Portacount Plus is a registered trademark of TSI Incorporated
EXPORT AND IMPORT
The international transport of this equipment is regulated under United
States export regulations and may be regulated by the import regula-
tions of other countries.
If you have any questions or concerns regarding these regulations,
contact SCOTT at 1-800-247-7257 (or 704-291-8300 outside the
continental United States).
QUESTIONS OR CONCERNS
If you have any questions or concerns regarding use of this equip-
ment, contact your authorized SCOTT distributor, or contact SCOTT
at 1-800-247-7257 (or 704-291-8300 outside the continental United
States).
Page 4 of 32
P/N 89332-01 Rev F 7/11
FACEPIECE FITTING AND FIT TESTING
A respirator Quantitative Fit Test must be performed to ensure the correct
respirator facepiece size has been selected and assigned to the user. It is
the responsibility of the Respiratory Protection Program Manager or Safety
Coordinator to assist the user in selecting the correct respirator size relative
to the user’s facial features and dimensions. Fit Testing must be performed
with any approved SCOTT accessories that will be used with the respirator
installed, such as a communications device installed on the facepiece.
Respirator fit tests are explained fully in the American National Standard
Practices for Respiratory Protection, ANSI Z88.10-2001 which is published
by the American National Standards Institute (ANSI), 11 West 42nd Street,
New York, New York, 10036, and in the Occupational Safety and Health
Standards, OSHA 29 CFR 1910.134 Appendix A, which is published by the
Occupational Safety and Health Administration (OSHA), 200 Constitution
Avenue, NW, Washington DC, 20210.
Quantitative Fit Testing per OSHA Standard 29 CFR Part 1910.134 Appendix A,
or ANSI Standard Z88.10-2001 requires testing in the negative pressure mode
using equipment such as a Portacount 1 Respirator Fit Tester. For Quantitative
Fit Testing, SCOTT facepieces require use of the appropriate negative pres-
sure testing equipment such as the Portacount Respirator Fit Tester along
with the following:
SCOTT 40mm facepiece Adapter, P/N 200423-01,
a new SCOTT P100 Cartridge, P/N 052683,
SCOTT Probed Fit Test Adapter P/N 805628-01 or equivalent probed
facepieces and the full range of sizes and styles
Mask Seal Kit, P/N 805655-01
the appropriate SCOTT communication device and mounting bracket
properly installed on the facepiece, if such an accessory will be used
with the respirator.
any other optional hood, eyeglass, or other accessory that will be used
with the respirator.
The size and style facepiece must be selected based on the user’s measured
face size. For initial fitting, carefully don the facepiece and conduct a NEGA-
TIVE PRESSURE LEAK TEST according to the instructions provided with the
40mm Adapter. Refer to the DONNING PROCEDURE section of this instruc-
tion for the procedure. Follow the DONNING PROCEDURE CAREFULLY. If
the selected facepiece does not pass the NEGATIVE PRESSURE LEAK TEST
or does not fit securely without movement in the chin or chin cup area or the
user experiences discomfort in the chin or throat, try the next nearest size,
larger or smaller. After passing the NEGATIVE PRESSURE LEAK TEST, the
facepiece size selected must be verified by successfully passing a respirator
Quantitative Fit Test.
When fit testing for Open-Circuit, Pressure Demand Self-Contained Breathing
Apparatus and/or Type C Pressure-Demand Supplied Air Respirator mode
of operation (minimum Fit Factor equal to or greater than 500 minimum)
appropriate negative pressure testing equipment must be used. You should
use a P100 Filter, SCOTT P/N 052683 and the SCOTT P/N 805628-01 Fit
Test Adapter.
When using a Portacount Respirator Fit Tester for Quantitative Fit Testing, TSI
recommends that the level of particles in the ambient air must be between
5000 and 30000 particles/cm3. Refer to the Portacount Respirator Fit Tester
user instructions for details including available Particle Generators to use
with the Portacount Respirator Fit Tester if you have difficulty achieving the
minimum level of ambient particle count required.
Test subjects must be in good health at the time of the fit testing. Smoking
or eating less than 30 minutes prior to the test is prohibited. Any and all
conditions that might interfere with a good face to facepiece seal must be
addressed and corrected before performing the fit testing. Refer to the list of
conditions in the DONNING PROCEDURES section of this instruction.
WARNING
FIT TESTING IN ACCORDANCE WITH OSHA
STANDARD 29 CFR PART 1910 IS REQUIRED
AS PART OF THE REQUIRED TRAINING
BEFORE USE OF THIS RESPIRATOR.
FAILURE TO PROPERLY FIT AND TRAIN
THE USER IN USE OF THE FACEPIECE AND
RESPIRATOR MAY RESULT IN EXPOSURE
TO THE HAZARDOUS ATMOSPHERE WHICH
COULD LEAD TO SERIOUS INJURY OR
DEATH.
WARNING
THE USER MUST BE PROPERLY FITTED
USING A RESPIRATOR QUANTITATIVE FIT
TEST BEFORE USE AND FOLLOW ALL
WARNINGS AND SPECIAL OR CRITICAL
USER’S INSTRUCTIONS SPECIFIED DURING
USE. FAILURE TO DO SO MAY RESULT IN
SERIOUS INJURY OR DEATH.
WARNING
RESPIRATORS SHALL NOT BE WORN WHEN
CONDITIONS PREVENT A GOOD FACE
SEAL. SUCH CONDITIONS MAY INCLUDE,
BUT ARE NOT LIMITED TO, GROWTH OF
BEARDS, SIDEBURNS, FACIAL HAIR OR LOW
HAIRLINE THAT CROSSES OR INTERFERES
WITH THE SEALING SURFACE, THICK OR
PROTRUDING HAIRSTYLES SUCH AS PONY
TAILS OR BUNS THAT INTERFERE WITH
THE SMOOTH AND CLOSE FIT OF THE HEAD
HARNESS TO THE HEAD, A SKULL CAP
THAT PROJECTS UNDER THE FACEPIECE,
TEMPLE PIECES ON CORRECTIVE EYE
GLASSES, EXCESSIVE USE OF COSMETICS
INCLUDING MOISTURIZERS, MAKE-UP,
OR AFTER SHAVE, OR ANYTHING ELSE
WHICH INTERFERES WITH THE FACE TO
FACEPIECE SEAL. ALSO, THE ABSENCE OF
ONE OR BOTH DENTURES CAN SERIOUSLY
AFFECT THE FIT OF A FACEPIECE. USE OF
AN IMPROPERLY FITTED FACEPIECE MAY
LEAD TO EXPOSURE TO THE HAZARDOUS
ATMOSPHERE WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
Page 5 of 32 P/N 89332-01 Rev F 7/11
To verify the fit factor of the respirator, testing must incorporate an exercise
regimen of normal daily activities. SCOTT requires the following set of fit
test exercises, which are based on OSHA Standard 29 CFR Part 1910.134
Appendix A, and ANSI Z88.10-2001 with modifications.
Exercises are to be performed each for 60 seconds (except as noted) in a
standing position during the test:
Normal Breathing
Deep breathing
Turning head side to side
Moving head up and down (look up/look down)
Talking (read the Rainbow Passage)
Grimace (15 seconds)
Bending Over (touch toes) / Reach up (toward the ceiling)
Normal Breathing (repeat)
Fit test exercises must be performed carefully as if the respirator was be-
ing used in a hazardous atmosphere. DO NOT bump the facepiece, filter,
or adapter into the body through exaggerated motions. DO NOT talk except
when directed to by the test administrator.
SCOTT requires that users of this respirator with an approved SCOTT face-
piece, must achieve a Fit Factor of at least 500 for Type C Pressure-Demand
Supplied Air Respirator mode of operation for use with their assigned face-
piece style and size using the fit test procedures and exercise regimen stated
above. If a Fit Factor of at least 500 cannot be achieved with any facepiece
size or style, the user MUST NOT use this respirator.
If the respirator user passes a NEGATIVE PRESSURE LEAK TEST but
DOES NOT pass a respirator Quantitative Fit Test, try the next nearest size,
larger or smaller and repeat the NEGATIVE PRESSURE LEAK TEST and
the Quantitative Fit Test. If leakage is still detected, either per these user
instructions or the OSHA fit testing process, the use of Mask Seal Kit P/N
805655-01 may be required to attain a proper fit. Refer to the INSTALLATION
AND USE INSTRUCTIONS, SCOTT P/N 89462-01, included with the Mask
Seal Kit. After installing the Mask Seal Kit, repeat the fit testing process to
confirm a proper fit.
Once the proper size is selected and assigned to the user following suc-
cessful Portacount Respirator Fit Tester testing to achieve minimum Fit
Factors required, the respirator user must perform and pass a NEGATIVE
PRESSURE LEAK TEST as described in these instructions every time the
facepiece is donned to ensure proper fit before using the respirator in a
hazardous atmosphere.
During NEGATIVE PRESSURE LEAK TESTING, any facepiece leakage that
is detected from other than the face to facepiece seal may indicate damaged
or defective equipment. Remove the defective equipment from service and
tag for repair by authorized personnel. Repeat the testing with equipment
known to be operating properly.
IF A SATISFACTORY NEGATIVE PRESSURE LEAK TEST CANNOT BE PER-
FORMED, DO NOT USE THE RESPIRATOR OR ENTER THE HAZARDOUS
ATMOSPHERE.
The facepiece alone does not provide any protection against a hazardous
atmosphere without the use of the complete respirator.
A respirator Quantitative Fit Test must be routinely carried out as outlined
above for each user of this respirator to determine or confirm the amount of
protection that the respirator provides.
Periodically repeating the fit testing is required to identify any physical
changes of the user (such as those listed in the DONNING PROCEDURES)
which could effect the fit of the facepiece.
Page 6 of 32
P/N 89332-01 Rev F 7/11
WARNING
FAILURE TO PROPERLY FIT THE
RESPIRATOR FACEPIECE TO THE USER MAY
RESULT IN LITTLE OR NO RESPIRATORY
PROTECTION AND MAY EXPOSE THE
WEARER TO SUBSTANCES WHICH CAN
CAUSE SERIOUS INJURY OR DEATH.
WARNING
THE RESPIRATOR USER MUST
IMMEDIATELY LEAVE THE AREA
REQUIRING RESPIRATORY PROTECTION
WHEN THE BELL END OF SERVICE
INDICATOR ALARM ACTUATES.
ACTUATION OF THE BELL END OF
SERVICE INDICATOR ALARM WARNS
THAT APPROXIMATELY 25% OF FULL
PRESSURE REMAINS IN THE AIR SUPPLY
CYLINDER (THAT IS, APPROXIMATELY
3/4 OF THE TOTAL AIR SUPPLY HAS
BEEN USED). A DELAY IN LEAVING THE
AREA AFTER ALARM ACTUATION MAY
RESULT IN INJURY OR DEATH.
WARNING
THE RESPIRATORY PROTECTION PROGRAM
UNDER WHICH THIS EQUIPMENT IS TO BE
USED MUST DETERMINE THE APPROPRIATE
LEVEL OF PROTECTION THAT THE
RESPIRATOR IS EXPECTED TO PROVIDE.
USE OF INAPPROPRIATE RESPIRATOR
EQUIPMENT FOR THE WORK ENVIRONMENT
MAY RESULT IN EXPOSURE TO THE
HAZARDOUS ATMOSPHERE WHICH MAY
CAUSE SERIOUS INJURY OR DEATH.
CHOOSING THE APPROPRIATE EQUIPMENT
Respirators reduce but do not eliminate all exposure to the hazardous at-
mosphere. Some facepiece/respirator combinations are more effective than
others at reducing exposure depending on the nature and the concentration
of the contaminant in the hazardous atmosphere. When choosing a respirator
and facepiece, the respiratory protection program under which this respira-
tor is to be used must determine the appropriate level of protection that the
facepiece/respirator is expected to provide. Use of inappropriate RESPIRA-
TOR equipment for the work environment may result in exposure to the
hazardous atmosphere which may cause serious injury or death.
The respiratory protection program must also take into consideration the levels
of exposure which may be hazardous irrespective of respiratory protection
(e.g.: contaminants which are toxic through exposure to unprotected skin).
Additional protective equipment such as apparel may be required. However,
any additional protective equipment must not interfere with access to or op-
eration of the respirator.
When properly donned and operated, the SCOTT ISCBA respirator provides
limited protection from airborne contaminants to only the respiratory system
and part of the face of the user. The using agency must provide the appro-
priate protective clothing for use with the ISCBA respirator and must insure
that protective clothing does not interfere with the operation of the ISCBA
respirator.
SERVICE LIFE
The 2216 ISCBA respirator is rated and approved by NIOSH as a 30 min-
ute duration unit and the 4500 ISCBA respirator is rated and approved by
NIOSH as a 30 minute / 45 minute / 60 minute duration unit (depending on
capacity of cylinder used) when properly donned, used and maintained by
trained personnel. A bell alarm actuates when approximately 25% of
the rated service time remains. The alarm will continue to operate
until the cylinder is nearly depleted.
The user should not expect to obtain exactly the rated service life from this
respirator on each use. The work being performed may be more or less
strenuous than that used in the NIOSH test. Where work is more strenuous,
the duration may be shorter, possibly as short as one-half the rated service
time. Likewise, the time remaining after the bell alarm actuates will be simi-
larly reduced.
The duration of the respirator will depend on such factors as:
1. the degree of physical activity of the user;
2. the physical condition of the user;
3. the degree to which the user’s breathing is affected by excitement, fear
or other emotional factors;
4. the degree of training or experience which the user has with this or similar
equipment;
5. whether or not the cylinder is fully charged at the start of the work period;
6. the possible presence in the compressed air of carbon dioxide concentra-
tions greater than .04% normally found in atmospheric air;
7. the atmospheric pressure; for example, if used in a pressurized tunnel
or caisson at 2 atmospheres (15 psi gauge) the duration will be one-half
as long as when used at 1 atmosphere; and at 3 atmospheres will be
one-third as long;
8. loose or improperly fitting facepiece;
9. the condition of the respirator being used.
WARNING
THIS RESPIRATOR PROVIDES PROTECTION
ONLY TO THE USER’S RESPIRATORY
SYSTEM AND TO PART OF THE FACE.
IF THE HAZARDOUS ATMOSPHERE
CONTAINS TOXINS OR CONTAMINANTS
WHICH MAY POISON THROUGH THE SKIN,
ADDITIONAL PROTECTIVE EQUIPMENT
MAY BE REQUIRED. FAILURE TO PROVIDE
ADEQUATE PROTECTIVE EQUIPMENT FOR
THE HAZARDS IN THE WORKPLACE MAY
RESULT IN SERIOUS INJURY OR DEATH.
NIOSH approval is granted to respiratory protection equipment made up of
specific combinations of parts or assemblies that have been successfully
tested to the performance standards established by the approval agencies.
To maintain NIOSH approval, an AV-3000 facepiece equipped with a SureSeal
face seal P/N 31001738 (Small), P/N 31001739 (Medium), or P/N 31001740
(Large) must be used only with Grey Nose Cup P/N 31001043 (Small), P/N
31001044 (Medium), or P/N 31001045 (Large).
If you are using an AV-3000 facepiece equipped with a SureSeal face seal
and do not have a Grey Nose Cup, contact SCOTT or your authorized SCOTT
distributor. Failure to comply with this requirement will void the approvals for
your respirator. Use of a non-approved configuration in a hazardous atmo-
sphere may result in serious injury or death.
WARNING
TO MAINTAIN NIOSH APPROVAL, AN AV-3000
FACEPIECE EQUIPPED WITH A SURESEAL
FACE SEAL P/N 31001738 (SMALL), P/N
31001739 (MEDIUM), OR P/N 31001740
(LARGE) MUST BE USED ONLY WITH
GREY NOSE CUP P/N 31001043 (SMALL),
P/N 31001044 (MEDIUM), OR P/N 31001045
(LARGE). USE OF A NON-APPROVED
CONFIGURATION IN A HAZARDOUS
ATMOSPHERE MAY RESULT IN SERIOUS
INJURY OR DEATH.
Page 7 of 32 P/N 89332-01 Rev F 7/11
ACCESSORIES
1. Neck Strap, P/N 804088-01, is used to hold facepiece in a ready position.
2. Hard carrying case, P/N 804497-01, and soft carrying case, P/N 10009324,
are used to store and transport respirator.
3. Duration Extending Accessory Hose Assembly is used for the purpose
of extending duration by means of a low pressure airline air supply.
NOTE
ONLY RESPIRATORS EQUIPPED WITH A DUAL OUTLET REDUCER CAN
HAVE THE DURATION EXTENDING ACCESSORY HOSE INSTALLED.
4. A variety of Lens Kits are available to allow installation of corrective
lenses in facepiece.
5. Gauge Protector Kit, P/N 804091-01, provides the remote reading pres-
sure gauge with protection from impact and abrasion.
6. Clear protective Lens Cover, P/N 803941-25 (package of 25), is used
to protect full facepiece lens against external scratching, spatter, paint
spray and abrasion.
7. Nose Cup Assembly, P/N 802819-01, is used to minimize fogging in
the SCOTT-O-VISTA facepiece and is required for use in temperatures
below 32 °F / 0 °C. Nose Cup installation kit, P/N 802862-01, must be
ordered when installing nose cup in the facepiece for the first time. The
installation kit contains the nose cup, adhesive and the required mount-
ing components.
8. Several communications devices are available for use with SCOTT Full
Facepieces with dual voicemitters. Consult with your SCOTT distributor
for details
9. Suit Pass-Thru Assembly, 803620 series, provides a means of delivering
respirable air to specific SCOTT SCBA worn in combination with a
protective garment or suit.
10. Refer to the FACEPIECE FITTING AND FIT TESTING section of this
instruction for information about Fit Testing Accessories. Consult your
SCOTT distributor for details of availability and application.
11. Emergency Breathing Support System (EBSS) allows 2 users of similarly
equipped SCBA’s to share a common air supply in the event one user
has an emergency.
12. Regulator Holder, P/N 10008880, attaches to the waist belt to conveniently
keep the breathing regulator secure and clean when not in use.
13. Facepieces for the respirator are available in a variety of sizes and con-
figurations. Consult with your SCOTT distributor for details about SCOTT
complete line of standard and special purpose full facepieces.
Page 8 of 32
P/N 89332-01 Rev F 7/11
WARNING
THE INFORMATION BELOW IS MEANT TO SUPPLEMENT, NOT REPLACE, THE INSTRUCTIONS, TRAIN-
ING, SUPERVISION, MAINTENANCE, AND OTHER ELEMENTS OF YOUR ORGANIZED RESPIRATORY
PROTECTION PROGRAM. SEE WARNING ON PAGE 1 OF THIS DOCUMENT. FAILURE TO HEED ANY
WARNINGS IN THIS INSTRUCTION MAY RESULT IN SERIOUS INJURY OR DEATH.
WARNING
FOLLOW THE REGULAR OPERATIONAL
INSPECTION PROCEDURE EXACTLY. IF
THE END OF SERVICE INDICATOR ALARM
DOES NOT ACTUATE AS DESCRIBED
IN THIS INSTRUCTION, THE PURGE
DOES NOT ACTUATE AS DESCRIBED
IN THIS INSTRUCTION OR ANY OTHER
OPERATIONAL MALFUNCTION IS NOTED,
DO NOT USE THE RESPIRATOR. REMOVE
THE RESPIRATOR FROM SERVICE AND
TAG IT FOR REPAIR BY AUTHORIZED
PERSONNEL. FAILURE TO PROPERLY
IDENTIFY MALFUNCTIONS MAY RESULT
IN SERIOUS INJURY OR DEATH.
WARNING
DAMAGED CYLINDERS MAY SUDDENLY
LEAK OR RUPTURE IF LEFT CHARGED WITH
COMPRESSED AIR. FAILURE TO INSPECT
FOR DAMAGE AND TO EMPTY THE AIR
FROM DAMAGED CYLINDERS MAY RESULT
IN SERIOUS INJURY OR DEATH.
WARNING
THE SMALL VENT HOLES IN THE
PRESSURE REDUCER MUST BE CLEAR
AND UNOBSTRUCTED FOR PROPER
OPERATION OF THE RESPIRATOR.
OBSTRUCTION OF THE VENT HOLES EITHER
BY DIRT ACCUMULATION OR CARELESS
APPLICATION OF USER LABELING MAY
RESULT IN A MALFUNCTION OF THE
RESPIRATOR WHICH COULD LEAD TO
SERIOUS INJURY OR DEATH.
INSPECTION OF THE BREATHING AIR CYLINDER
1. Visually inspect breathing air cylinder and valve assembly for
physical damage such as dents or gouges in metal or in composite
wrapping. Cylinders which show physical damage or exposure to
high heat or flame, such as paint turned brown or black, decals
charred or missing, pressure gauge lens melted or elastomeric
bumper distorted, and cylinders which show evidence of exposure
to chemicals such as discoloration, cracks in the cylinder or the
composite wrapping, peeling of the outer layers of the composite
wrapping and/or bulging of the cylinder wall, shall be removed
from service and emptied of compressed air. Publications on
compressed gas cylinder inspection procedures are available from
Compressed Gas Association Inc., 1725 Jefferson Davis Hwy.,
Suite 1004, Arlington, VA 22202 (703-412-0900).
2. Check the latest cylinder hydrostatic test date to ensure it is cur-
rent. The date of manufacture marked on the cylinder is also the
date of the first hydrostatic test. All breathing air cylinders used
with SCOTT AIR-PAK SCBA’s must be visually inspected regularly
and hydrostatically tested at the required intervals by a licensed
cylinder retester. Intervals for hydrostatic testing are established in
the appropriate US Department of Transportation (DOT) specifica-
tion or applicable DOT exemption, or in the appropriate Transport
Canada (TC) Permit of Equivalent Level of Safety. Refer to the
current revision of Safety Precautions for AIR-PAK Cylinders,
SCOTT P/N 89080-01, available on request from SCOTT Safety.
Composite fiber overwrapped cylinders must be tested up to
their maximum life which, at the time of the publication of this
instruction, is 15 years from the date of manufacture. It is the
responsibility of your organized respiratory protection program to
arrange for visual inspection and hydrostatic testing of cylinders
by a licensed retester.
3. Check for damage of the cylinder valve hand wheel and the
threads on the cylinder valve outlet.
4. Check the relief valve (burst disc) for damage or dirt.
5. Check the cylinder pressure gauge for “FULL” indication. If cyl-
inder pressure is less than “FULL,” replace with a fully charged
cylinder.
Proceed to INSPECTION OF THE RESPIRATOR
REGULAR OPERATIONAL INSPECTION
The following procedure shall be used when you first receive the
respirator and for regular inspection of the respirator. Respirators main-
tained for emergency use must be inspected as frequently as required
to assure the respirator will function properly when required. The US
Labor Department (OSHA), pursuant to 29 CFR 1910.134, requires at
least monthly inspection of respirators maintained for emergency use.
NIOSH recommends an inspection for cylinder pressure at least weekly.
All respirators shall be inspected after each use. If any damage or
malfunction is noted, remove the respirator from service and tag for
repair by authorized personnel.
IF ANY DISCREPANCY OR MALFUNCTION IS NOTED DURING
THE INSPECTION, DO NOT USE THE RESPIRATOR. REMOVE
THE RESPIRATOR FROM SERVICE AND TAG IT FOR REPAIR
BY AUTHORIZED PERSONNEL.
Page 9 of 32 P/N 89332-01 Rev F 7/11
WARNING
RESPIRATORS MUST BE CLEANED AND
INSPECTED BEFORE STORAGE FOR REUSE.
RESPIRATORS WITH WORN OR DAMAGED
COMPONENTS SHALL NOT BE STORED FOR
REUSE. REPLACE WORN OR DAMAGED
COMPONENTS DURING INSPECTION OR
REMOVE THE RESPIRATOR FROM SERVICE
AND TAG IT FOR REPAIR BY AUTHORIZED
PERSONNEL. USE OF A RESPIRATOR WITH
WORN OR DAMAGED COMPONENTS MAY
RESULT IN SERIOUS INJURY OR DEATH.
REGULAR OPERATIONAL INSPECTION
CONTINUED ON NEXT PAGE...
INSPECTION OF THE RESPIRATOR
If any damage is found in this inspection, remove the respirator from
service and tag for repair by authorized personnel.
1. Inspect the complete respirator for worn or damaged compo-
nents.
a) Inspect hoses and rubber parts which exhibit cracking, splitting,
or brittleness.
b) Inspect harness webbing for cuts, tears, abrasion, fraying, or
indication of heat or chemical damage.
c) Check all buckles and fasteners for proper operation.
d) Check the cylinder retention system for damage and for proper
operation.
e) Verify that the respirator has been properly cleaned.
2. Remove the breathing regulator from the facepiece by pulling
back on the regulator retaining latch and rotating the regulator
¼ turn. Inspect the gasket on the breathing regulator that seals
against the facepiece for rips or damage that may break the
seal.
3. Inspect the breathing regulator for damaged or missing compo-
nents.
a) Verify that the regulator gasket is not damaged and is in place
around the outlet port of the regulator.
b) Verify that the purge valve (red knob) is not damaged and turns
smoothly one-half turn from stop to stop.
Reconnect the coupling by pushing the plug into the coupling until
the sleeve snaps forward. Check that the disconnect is engaged
properly by tugging on the coupling.
5. Verify that a FULL cylinder is properly installed in the backframe
and that the reducer hose coupling is hand tightened to the cyl-
inder valve outlet.
Proceed to INSPECTION OF THE FACEPIECE.
4. If the breathing regulator is equipped with a MODULAIR quick dis-
connect, SEPARATE the regulator from the respirator by pushing
THE MALE PLUG INTO THE coupling connection WHILE pulling
back on the outer sleeve of the female coupling. The disconnect
will separate. See FIGURE 2.
FIGURE 2
PUSH PLUG IN
PULL SLEEVE
BACK
SLEEVEPLUG WARNING
FAILURE TO CHECK ENGAGEMENT OF
THE COUPLING AS DESCRIBED MAY LEAD
TO HOSE SEPARATION AND LOSS OF
BREATHING AIR RESULTING IN SERIOUS
INJURY OR DEATH.
CAUTION
DO NOT USE TOOLS TO OPEN OR CLOSE
THE PURGE VALVE. OPEN OR CLOSE BY
USING FINGER-PRESSURE ONLY. ROTATION
OR THE PURGE VALVE IS LIMITED TO 1/2
TURN. USE OF TOOLS TO OPEN OR CLOSE
PURGE VALVE MAY RESULT IN DAMAGE TO
THE PURGE VALVE.
Page 10 of 32
P/N 89332-01 Rev F 7/11
REGULAR OPERATIONAL INSPECTION Continued...
CAUTION
IF THE NOSE CUP IS REMOVED FOR
INSPECTION, MAKE CERTAIN IT IS
REASSEMBLED CORRECTLY FOR THE
MODEL FACEPIECE AND STYLE OF NOSE
CUP.
FIGURE 3
Checking Voicemitter Ducts
INSPECTION OF THE FACEPIECE
Examine the facepiece assembly for damaged or worn components.
The facepiece must be complete and in serviceable condition with no
worn, loose, or damaged components.
The AV-2000 style facepieces include the AV-2000, the Weld-O-
Vista, and the Scott-O-Vista (the Scott-O-Vista does not have
voicemitters).
The AV-3000 style facepieces include the AV-3000 and the AV-
3000 SureSeal.
Inspect the facepiece as follows:
1. Inspect the facepiece seal and other rubber components for de-
formation, wear, damage, or cracks.
2. Inspect the lens for cracks, gouges, scratches, or any condition
that could impair the operation of the facepiece or the user’s
vision.
3. Inspect the lens frame or bezel for damage such as cracks or
distortion.
4. Check that all lens frame retainers or bezel screws are present
and installed correctly.
5. Check that all harness anchors are present and operating prop-
erly.
6. Inspect the head harness for correct installation with all straps
oriented correctly.
7. Inspect the head harness for damage or worn components.
8. Inspect the voicemitters for dents or damage. Verify that the
voicemitters are properly installed and secure in the voicemitter
ducts.
9. Inspect the nose cup for cuts or damage. Also look for any signs
of damage to the facepiece port side of the nose cup where the
regulator attaches.
10. Check that the nose cup is properly seated between the flanges
of the voicemitter ducts. See FIGURE 3.
11. All SCOTT facepieces used with this respirator may be fitted with
a nose cup. Verify that the Nose Cup is properly installed for the
model of facepiece being used. A Nose Cup is standard on the
SCOTT AV-2000, Weld-O-Vista, and AV-3000 full facepieces and
optional on the SCOTT-O-VISTA full facepiece.
a) SCOTT AV-3000 Facepieces are available with two different
styles of nose cup: a BLACK Nose Cup which fits behind the
face seal, and a GRAY Nose Cup which fits in front of the face
seal. The BLACK Nose cup must be fitted BEHIND the Face
Seal as shown in FIGURE 4. The GRAY Nose Cup must be
fitted IN FRONT OF the Face Seal as shown in FIGURE 5.
Page 11 of 32 P/N 89332-01 Rev F 7/11
OPERATIONAL TESTING
1. Fully depress the center of the air saver/donning switch on the
top of the regulator and release.
2. Slowly open the cylinder valve by fully rotating knob counterclock-
wise. The bell alarm shall actuate and then stop. There shall be
no airflow from the facepiece
3. Don the facepiece or hold the facepiece to the face to effect a good
seal. Inhale sharply to automatically start the flow of air. Breathe
normally from the facepiece to ensure proper operation.
4 Remove facepiece from face. Air shall freely flow from the
facepiece.
5. Fully depress the center of the air saver/donning switch on the
top of regulator and release. The flow of air from the facepiece
shall stop.
6. Rotate purge valve 1/2 turn counterclockwise (pointer on knob
downward). Air shall freely flow from the regulator.
7. Rotate purge valve 1/2 turn clockwise to full closed position
(pointer on knob upward). Airflow from regulator shall stop.
8. Push in and rotate cylinder valve knob clockwise to close. When
cylinder valve is fully closed, open purge valve slightly to vent
residual air pressure from system. The bell alarm shall actuate
as the pressure drops below approximately 1/4 full. When airflow
stops, return purge valve to the fully closed position (pointer on
knob upward).
CAUTION
DO NOT USE TOOLS TO OPEN OR CLOSE
THE PURGE VALVE. OPEN OR CLOSE BY
USING FINGER-PRESSURE ONLY. ROTATION
OF THE PURGE VALVE IS LIMITED TO 1/2
TURN. USE OF TOOLS TO OPEN OR CLOSE
PURGE VALVE MAY RESULT IN DAMAGE TO
THE PURGE VALVE.
WARNING
FAILURE TO CHECK ENGAGEMENT OF
THE COUPLING AS DESCRIBED MAY LEAD
TO HOSE SEPARATION AND LOSS OF
BREATHING AIR RESULTING IN SERIOUS
INJURY OR DEATH.
WARNING
IF THE END OF SERVICE INDICATOR BELL
ALARM DOES NOT ACTUATE AS DESCRIBED
IN THIS INSTRUCTION, DO NOT USE THE
RESPIRATOR. REMOVE THE RESPIRATOR
FROM SERVICE AND TAG IT FOR REPAIR
BY AUTHORIZED PERSONNEL. USE OF AN
IMPROPERLY OPERATING END OF SERVICE
INDICATOR BELL ALARM MAY RESULT IN
SERIOUS INJURY OR DEATH.
CAUTION
WRENCHES SHALL NOT BE USED TO
TIGHTEN THE HOSE COUPLING. OVER
TIGHTENING THE HOSE COUPLING MAY
DAMAGE THE NIPPLE SEAL.
AV-3000 FACEPIECES ONLY
FIGURE 4
BLACK Nose Cup
BEHIND Face Seal
FIGURE 5
GRAY Nose Cup
IN FRONT OF Face Seal
BLACK
BEHIND
FACE SEAL
GRAY
IN FRONT OF
FACE SEAL
AV-2000 FACEPIECES ONLY
AV-2000 Nose Cup
Always BEHIND the Face Seal
FIGURE 6
b) The AV-2000, the Weld-O-Vista, and the SCOTT-O-VISTA, the
Nose Cup always goes BEHIND the face seal REGARDLESS
of the color of the nose cup. See FIGURE 6.
12. Verify that the facepiece is clean.
13. Adjust the head straps to the full outward position.
If no damage is found, proceed to the OPERATIONAL TESTING.
CAUTION
OVERTIGHTENING THE CYLINDER VALVE
MAY CAUSE DAMAGE THAT COULD RESULT
IN LEAKAGE OF AIR FROM THE CYLINDER.
USE NO TOOLS TO CLOSE THE CYLINDER
VALVE.
Page 12 of 32
P/N 89332-01 Rev F 7/11
WARNING
THE CYLINDER VALVE MUST BE FULLY
OPENED FOR PROPER OPERATION OF THE
RESPIRATOR. USE OF A RESPIRATOR WITH
THE CYLINDER VALVE PARTIALLY OPENED
MAY CAUSE A REDUCTION OF THE AIR
SUPPLIED TO THE USER AND/OR A SUDDEN
AND COMPLETE LOSS OF AIR SUPPLIED TO
THE USER. A REDUCTION OR LOSS OF AIR
TO THE USER MAY RESULT IN EXPOSING
THE USER TO THE ATMOSPHERE THE
RESPIRATOR IS INTENDED TO PROTECT
AGAINST AND LEAD TO SERIOUS INJURY
OR DEATH.
WARNING
BEFORE ENTERING A POTENTIALLY
HAZARDOUS ATMOSPHERE OR UNKNOWN
CONDITION, THE USER MUST DETERMINE
THAT THE CYLINDER CONTAINS SUFFICIENT
AIR TO ALLOW TIME FOR COMPLETION OF
THE TASK INVOLVED AND RETURN TO A
SAFE ATMOSPHERE WITH AN ADEQUATE
MARGIN FOR SAFETY. THE USER SHOULD
ALWAYS START WITH A FULL TANK.
PARTIALLY FILLED TANKS SHOULD ONLY
BE USED IN EMERGENCY CONDITIONS
IF FULL TANKS ARE NOT AVAILABLE.
ENTERING A HAZARDOUS ATMOSPHERE
WITH INSUFFICIENT AIR OR AFTER THE
END OF SERVICE TIME INDICATOR HAS
ACTUATED MAY RESULT IN SERIOUS
INJURY OR DEATH.
WARNING
FAILURE TO CHECK ENGAGEMENT OF
THE COUPLING AS DESCRIBED MAY LEAD
TO HOSE SEPARATION AND LOSS OF
BREATHING AIR RESULTING IN SERIOUS
INJURY OR DEATH.
PREPARATION FOR USE
DONNING THE ISCBA RESPIRATOR
1. Always check the cylinder gauge for a “FULL” indication. If the cyl-
inder is not full, replace the cylinder before use. A gauge indication
of other than full may indicate an air leak in the cylinder and valve
assembly or a malfunction of the gauge assembly.
2. Always verify that the cylinder is held securely by the cylinder reten-
tion assembly.
3. If the respirator is stored in a hard or soft storage case:
a) Place the case on the ground or level surface and open the
case.
b) Stand the respirator on the cylinder valve with cylinder toward you
and the shoulder straps away from you.
c) Grasp both shoulder pads, one in each hand.
d) Pick up the respirator and swing it around behind you.
e) Release your grasp while sliding your arms under the shoulder
pads. Ensure that the shoulder pads fall into place on the shoul-
ders.
f) While leaning slightly forward, pull down on the shoulder straps
to adjust the harness to fit your body.
4. If a wall storage bracket is used, follow the instructions of the bracket
manufacturer for placing arms through shoulder straps and freeing
the respirator from the bracket.
a) Ensure that the shoulder pads fall into place on the shoulders.
b) While leaning slightly forward, pull down on the shoulder straps
to adjust the harness to fit your body.
5. While still leaning slightly forward, connect the waist belt buckle and
adjust the belt by pulling forward on the two (2) side-mounted belt
ends. Tuck the belt ends into the waistband.
6. Stand up straight and readjust the shoulder straps as needed to
ensure the weight of the backframe is carried on the hips. Tuck the
shoulder strap ends under the shoulder straps.
7. Fully depress the center of the air saver/donning switch on top of
regulator and release.
8. If the regulator is not attached to the facepiece, proceed as fol-
lows:
a) Verify that the regulator gasket is not damaged and is in place
around the outlet port of the regulator.
b) Align the two flats of the regulator outlet port with the correspond-
ing flats in the facepiece port (the red purge valve on the regula-
tor will be in the 12 o’clock position). Insert the regulator into the
facepiece port.
c) Rotate the regulator counterclockwise (as viewed from inside of
facepiece) until the red purge valve knob is on the left side of the
facepiece. The lock tab on the regulator will lock into the facepiece
retainer with a “click.” When the lock tab is properly engaged, the
regulator will not rotate.
USE OF THE RESPIRATOR
The following information provides the basic steps for use of the
ISCBA respirator. Training and practice with the equipment are re-
quired before use to assure that the user is completely familiar with
the operation of the respirator.
The ISCBA respirator is typically worn over most protective garments,
but may be worn under encapsulating protective garments such as
haz-mat suits. Determine what other protective gear will be used and
don the ISCBA respirator and the facepiece accordingly.
If respirator use is expected at temperatures near or below freezing,
or if respirator is to be used after being kept at temperatures near or
below freezing, refer to LOW TEMPERATURE OPERATION Section
for additional information and supplemental procedures.
WARNING
THE INFORMATION IN THIS INSTRUCTION IS
MEANT TO SUPPLEMENT, NOT REPLACE, THE
INSTRUCTIONS, TRAINING, SUPERVISION,
MAINTENANCE, AND OTHER ELEMENTS
OF YOUR ORGANIZED RESPIRATORY
PROTECTION PROGRAM. SEE WARNING
ON PAGE ONE OF THIS DOCUMENT.
FAILURE TO HEED ANY WARNINGS IN THIS
INSTRUCTION MAY RESULT IN SERIOUS
INJURY OR DEATH.
Page 13 of 32 P/N 89332-01 Rev F 7/11
WARNING
IF THE END OF SERVICE INDICATOR BELL
ALARM DOES NOT ACTUATE AS DESCRIBED
IN THIS INSTRUCTION, DO NOT USE THE
RESPIRATOR. REMOVE THE RESPIRATOR
FROM SERVICE AND TAG IT FOR REPAIR
BY AUTHORIZED PERSONNEL. USE OF AN
IMPROPERLY OPERATING END OF SERVICE
INDICATOR BELL ALARM MAY RESULT IN
SERIOUS INJURY OR DEATH.
USE OF RESPIRATOR
CONTINUED ON NEXT PAGE...
CHECK THE OPERATION OF THE ISCBA RESPIRATOR
1. Slowly open cylinder valve fully by turning the valve knob counter-
clockwise until it stops (approximately 2 1/2 full turns of the knob).
The bell alarm shall actuate and then stop. There shall be no airflow
from the facepiece
2. Don the facepiece or hold the facepiece to the face to effect a good
seal. Inhale sharply to automatically start the flow of air. Breathe
normally from the facepiece to ensure proper operation.
3 Remove facepiece from face. Air shall freely flow from the face-
piece.
4. Fully depress the center of the air saver/donning switch on the top of
regulator and release. The flow of air from the facepiece shall stop.
5. Rotate purge valve 1/2 turn counterclockwise (pointer on knob down-
ward). Air shall freely flow from the regulator.
6. Rotate purge valve 1/2 turn clockwise to full closed position (pointer
on knob upward). Airflow from regulator shall stop.
7. Push in and rotate cylinder valve knob clockwise to close. When cyl-
inder valve is fully closed, open purge valve slightly to vent residual
air pressure from system. The bell alarm shall actuate as the pressure
drops below approximately 1/4 full. When airflow stops, return purge
valve to the fully closed position (pointer on knob upward).
8. The user of the respirator is now in “standby” condition. The respira-
tor is in place on the user’s body but the facepiece is not donned
(sealed to the face) and the respirator is not being used. Keep the
facepiece ready for use either of two ways:
a) Hang the facepiece from the snap clip on the left shoulder pad,
b) Hang the facepiece from the optional neck strap.
9. The regulator can be detached from the facepiece until needed. To
detach the regulator from the facepiece:
a) Place your right hand over the cover with your thumb on the lock
tab.
b) Pull the lock tab toward the cover and rotate the regulator 1/4 turn
clockwise (viewed from inside of facepiece).
c) When the red purge valve is in the 12 o’clock position remove
regulator from the facepiece.
d) The regulator can be stored in the optional regulator holder on the
waist belt.
Proceed to the FACEPIECE DONNING PROCEDURES section of this
instruction.
CAUTION
OVERTIGHTENING THE CYLINDER VALVE
MAY CAUSE DAMAGE THAT COULD RESULT
IN LEAKAGE OF AIR FROM THE CYLINDER.
USE NO TOOLS TO CLOSE THE CYLINDER
VALVE.
Page 14 of 32
P/N 89332-01 Rev F 7/11
USE OF RESPIRATOR CONTINUED...
FACEPIECE DONNING PROCEDURES
Before use of the respirator, the user must read and practice the
procedures for donning, use, and termination of use. The user must
be familiar with and practice the prescribed donning, leak test, use,
and termination of use procedures prior to respirator use. Follow the
donning instructions for the model facepiece you have.
The DONNING INSTRUCTIONS for FOUR STRAP full facepieces
(such as the AV-2000, AV-3000, Scott-O-Vista, and the Weld-O-Vista)
and the FIVE STRAP full facepieces (such as the AV-3000 SureSeal)
are included in this instruction.
The respirator MUST NOT be worn when conditions prevent a good
face to facepiece seal. Such conditions include but are not limited
to:
long hair at the forehead or the side of the face that interferes with
the sealing surface or gets caught in the head harness buckles,
facial hair such as growth of beard or sideburns, or low hairline
that crosses or interferes with the sealing surface,
thick or protruding hairstyles such as pony tails or buns that in-
terfere with the smooth and close fit of the head harness to the
head,
temple pieces on corrective glasses,
a skull cap that projects under the facepiece,
excessive use of cosmetics including moisturizers, make-up, or
after shave,
the absence of one or both dentures,
weight loss or weight gain since last fit testing,
facial scarring,
anything else which interferes with the face to facepiece seal or
the fit of the head harness to the head.
Periodically repeating the fit testing is required to identify any physical
changes of the user (such as those listed above) which could affect
the fit of the facepiece.
NOTE
IF THE STYLE FULL FACEPIECE RESPIRATOR MASK IS BEING DONNED
FOR THE FIRST TIME OR IF THIS IS THE FIRST TIME A PARTICULAR
STYLE FACEPIECE IS TO BE USED, REFER TO THE APPROPRIATE
STEPS IN THE FACEPIECE FITTING SECTION OF THIS INSTRUCTION.
DURING TRAINING, THE USER MUST DETERMINE THE LEVEL OF TIGHT-
NESS OF THE HEAD HARNESS REQUIRED TO PROVIDE THE BEST SEAL
AND MOST SECURE FIT.
If the facepiece is to be used with a hood, refer to the donning instruc-
tions provided with the hood. For other head gear that will cover the
facepiece head harness and/or hood, don the facepiece/hood first,
then don the other head gear.
To don the facepiece and begin use of respirator, proceed as
follows:
WARNING
RESPIRATORS SHALL NOT BE WORN WHEN
CONDITIONS PREVENT A GOOD FACE SEAL.
SUCH CONDITIONS MAY INCLUDE, BUT ARE
NOT LIMITED TO, GROWTH OF BEARDS,
SIDEBURNS, FACIAL HAIR OR LOW
HAIRLINE THAT CROSSES OR INTERFERES
WITH THE SEALING SURFACE, THICK OR
PROTRUDING HAIRSTYLES SUCH AS PONY
TAILS OR BUNS THAT INTERFERE WITH THE
SMOOTH AND CLOSE FIT OF THE HEAD
HARNESS TO THE HEAD, A SKULL CAP
THAT PROJECTS UNDER THE FACEPIECE,
TEMPLE PIECES ON CORRECTIVE EYE
GLASSES, EXCESSIVE USE OF COSMETICS
INCLUDING MOISTURIZERS, MAKE-UP,
OR AFTER SHAVE, OR ANYTHING ELSE
WHICH INTERFERES WITH THE FACE TO
FACEPIECE SEAL. ALSO, THE ABSENCE OF
ONE OR BOTH DENTURES CAN SERIOUSLY
AFFECT THE FIT OF A FACEPIECE. USE OF
AN IMPROPERLY FITTED FACEPIECE MAY
LEAD TO EXPOSURE TO THE HAZARDOUS
ATMOSPHERE WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
Page 15 of 32 P/N 89332-01 Rev F 7/11
FIGURE 19
DONNING THE FOUR STRAP FACEPIECE
7-B7-A
7-C 7-D
WARNING
FAILURE TO DON THE FACEPIECE AND/OR
FAILURE TO ADJUST THE HEAD HARNESS
AS DESCRIBED IN THIS INSTRUCTION MAY
RESULT IN A POOR FACE TO FACEPIECE
SEAL OR MAY RESULT IN THE FAILURE OF
THE FACE TO FACEPIECE SEAL DURING USE.
A POOR OR FAILED FACE TO FACEPIECE
SEAL MAY REDUCE THE DURATION OF
USE OF THE RESPIRATOR AND/OR EXPOSE
THE USER TO THE ATMOSPHERE THE
RESPIRATOR IS INTENDED TO PROTECT
AGAINST RESULTING IN SERIOUS INJURY
OR DEATH.
DONNING THE FOUR STRAP FACEPIECE
(including: AV-2000, AV-3000, Scott-O-Vista, and Weld-O-
Vista)
1. Adjust the head straps to their full outward position.
2. Hold the facepiece in one hand and hold the head harness by the
strap at the base of the head net.
3. Place the facepiece on the face with chin properly located in the
chin pocket while pulling the head harness over the top of the
head. Verify that no hair or clothing is interfering with the face to
facepiece seal. See FIGURE 7-A.
4. Tighten the neck straps by pulling the two lower strap ends toward
the rear of the head. See FIGURE 7-B.
5. Stroke the head harness net down the back of the head using one
or both hands. Verify that the head harness is lying flat against
the back of the head. Retighten the neck straps. See FIGURE
7-C.
6. Tighten the two temple straps. Adjust the temple straps by pulling
the two temple strap ends toward the back of the head. Overtight-
ening may cause discomfort. See FIGURE 7-D.
7. Retighten the neck straps if required.
8. Refer to the DONNING PROBLEMS section of this instruction.
NOTE
VERIFY THAT THE TOP CENTER POR-
TION OF THE HEAD HARNESS IS
POSITIONED OVER THE CROWN OF
THE HEAD.
NOTE
ENSURE THAT THE CHIN IS PROPERLY
LOCATED IN THE CHIN POCKET OF
THE FACEPIECE THROUGHOUT THE
DONNING PROCESS.
USE OF THE RESPIRATOR
CONTINUED ON NEXT PAGE...
Page 16 of 32
P/N 89332-01 Rev F 7/11
USE OF RESPIRATOR CONTINUED...
DONNING THE FIVE STRAP AV-3000 SURESEAL FACEPIECE
1. Adjust the head straps to the full outward position.
2. Hold the facepiece in one hand while holding the head harness
up and out of the way with other hand. If so equipped, use the
Head Harness Pull Tab on the bottom rear of the head harness
3. Place the facepiece centered on the face with the chin properly
positioned in the chin cup. Verify that no hair or clothing is in-
terfering with the face to facepiece seal. Hold the facepiece in
place with the chin properly located in the chin cup throughout
the donning process.
4. Stroke the head harness over the head and ensure that straps are
lying smooth and flat against the head and neck with no twists.
Verify the head harness is centered and properly located at the
back and base of the head. Maintain the head harness in this
position.
FIGURE 8-A
ADJUST HEAD STRAPS OUT
FIGURE 8-B
HARNESS OUT OF WAY
FIGURE 8-D
HEAD HARNESS POSITION
FIGURE 8-C
CHIN IN CHIN POCKET
NOTE
VERIFY THAT THE TOP CENTER POR-
TION OF THE HEAD HARNESS IS
POSITIONED OVER THE CROWN OF
THE HEAD.
NOTE
ENSURE THAT THE CHIN IS PROPERLY
LOCATED IN THE CHIN POCKET OF
THE FACEPIECE THROUGHOUT THE
DONNING PROCESS.
Page 17 of 32 P/N 89332-01 Rev F 7/11
USE OF RESPIRATOR
CONTINUED ON NEXT PAGE...
FIGURE 8-H
HEAD HARNESS
MUST BE FLAT AND CENTERED
5. While holding the facepiece in place with one hand, tighten the
neck straps evenly one at a time by pulling each neck strap end
toward the rear of the head. Alternate hands to maintain the face-
piece position on the face.
6. Verify the proper location of the face in the facepiece and the
chin in the chin cup. While still holding the facepiece in place with
one hand, tighten the temple straps evenly one at a time by pull-
ing each temple strap end toward the rear of the head. Alternate
hands to maintain the facepiece position on the face.
7. Verify the proper location of the face in the facepiece and the
chin in the chin cup. Tighten the forehead strap last by pulling the
forehead strap toward the back of the head. Do not overtighten
the forehead strap.
8. Verify that the head harness is centered on the crown of the head
and lying flat against the back of the head. Verify the proper loca-
tion of the face in the facepiece and the chin in the chin cup and
retighten all straps as needed.
FIGURE 8-E
HOLD AND TIGHTEN
FIGURE 8-F
HOLD AND TIGHTEN
FIGURE 8-G
TIGHTEN FOREHEAD STRAP
NOTE
ENSURE THAT THE CHIN IS PROPERLY
LOCATED IN THE CHIN POCKET OF
THE FACEPIECE THROUGHOUT THE
DONNING PROCESS.
Page 18 of 32
P/N 89332-01 Rev F 7/11
USE OF RESPIRATOR CONTINUED...
FIGURE 8-J
RETIGHTEN IF REQUIRED
NOTE
VERIFY THAT THE TOP CENTER POR-
TION OF THE HEAD HARNESS IS
POSITIONED OVER THE CROWN OF
THE HEAD.
9. Stroke the head harness down the back of the head and make
sure the net is centered on your head. If necessary, adjust the
head harness net to the center of the crown of the head.
10. Verify the proper location of the face in the facepiece and the chin
in the chin cup. Retighten the straps if required. All straps must
be snug and the facepiece should feel secure.
11. Refer to the DONNING PROBLEMS section of this instruction.
NOTE
VERIFY THAT THE TOP CENTER POR-
TION OF THE HEAD HARNESS IS
POSITIONED OVER THE CROWN OF
THE HEAD.
FIGURE 8-I
CENTER HEAD HARNESS ON THE CROWN OF THE HEAD
Page 19 of 32 P/N 89332-01 Rev F 7/11
DONNING PROBLEMS
1. Perform a personal check of the Facepiece and Head Harness
and address any donning problems. OSHA standard 29 CFR
1910.134 requires teams of at least two people for situations
where this type of equipment is used. Have your partner help
you verify the facepiece is donned properly.
Possible problems include:
a) Head Harness Strap twisted,
b) Head Harness off-center or not flat against the head,
c) Head Harness too high on the head,
d) Hair or clothing in the face seal,
e) Face seal rolled over inside the facepiece rather than flat
against the face
f) Facepiece is sitting too low on the face as evidenced by pres-
sure on the forehead or the facepiece making contact with the
throat area permitting a break in the seal.
The illustrations below depict the AV-3000 SureSeal, but similar
conditions can occur with the AV-2000 or AV-3000 facepiece as
well.
If any donning problems are found, remove the facepiece and
re-don the facepiece correctly.
2. Proceed to BEGIN USE OF THE RESPIRATOR as instructed
below.
WARNING
IF ANY DONNING PROBLEMS ARE
FOUND, REMOVE THE FACEPIECE AND
RE-DON IT CORRECTLY. USE OF AN
IMPROPERLY DONNED FACEPIECE MAY
LEAD TO EXPOSURE TO THE HAZARDOUS
ATMOSPHERE WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
FIGURE 9
DONNING PROBLEMS
HARNESS STRAP
TWISTED
HEAD HARNESS
OFF CENTER
HEAD HARNESS
TOO HIGH
FACE SEAL
ROLLED OVER
FACEPIECE
TOO LOW
USE OF RESPIRATOR
CONTINUED ON NEXT PAGE...
Page 20 of 32
P/N 89332-01 Rev F 7/11
BEGIN USE OF THE RESPIRATOR
WARNING
WHEN THE BELL ALARM ACTUATES IT
WARNS THE USER THAT APPROXIMATELY
25% OF THE FULL PRESSURE REMAINS IN
THE CYLINDER (THAT IS, APPROXIMATELY
3/4 OF THE TOTAL AIR SUPPLY HAS
BEEN USED). IN THIS EVENT, LEAVE THE
CONTAMINATED AREA AT ONCE. IN AREAS
WHERE MORE THAN ONE RESPIRATOR IS
BEING USED, YOU MAY IDENTIFY YOUR
OWN ALARM BY SENSING THE VIBRATIONS
THROUGH YOUR BACKFRAME.
1. If regulator is not attached to facepiece, be sure the regulator
gasket is in place around the outlet port of the regulator and not
damaged.
2. To attach the regulator to the facepiece, hold the regulator with
the red purge valve in the 12 o’clock position, align the two flats
of the outlet port with corresponding flats in the facepiece port
and insert. Rotate the regulator counterclockwise (viewed from
inside of facepiece) so that the red purge valve knob is situated on
the left side of the facepiece. The lock tab on the mask-mounted
regulator will lock into the facepiece retainer with a “click”. When
properly engaged, the regulator will not rotate.
With facepiece sealed to face, inhale sharply to actuate respirator.
Air will then be supplied during inhalation.
NOTE
IF AIR IS NOT SUPPLIED ON FIRST INHALATION, CHECK THAT
CYLINDER VALVE IS OPEN, REMOTE GAUGE INDICATES PRES-
SURE IN CYLINDER AND FACEPIECE IS SEALED TO FACE.
3. NEGATIVE PRESSURE LEAK TEST – Close cylinder valve by
simultaneously pushing in on cylinder valve knob and rotating it
clockwise. Breathe on respirator until airflow stops. The bell alarm
will actuate, then stop. Inhale slowly and hold your breath mo-
mentarily. No leakage of air shall be detected and the facepiece
shall be drawn slightly to the face. Open cylinder valve fully and
breathe normally.
4. If the environment is suitably quiet, leakage from the facepiece
can also be detected by listening for a flow of air while holding
your breath. Inhale and hold your breath momentarily after don-
ning the facepiece. Do not depress air saver switch. Air should
not be heard flowing into the facepiece from the regulator and no
flow of air shall be detected outward from the facepiece.
NOTE
IF LEAKAGE OF AIR IS DETECTED DURING EITHER OF THE
ABOVE PROCEDURES, DEPRESS THE AIR SAVER/DONNING
SWITCH ON THE TOP OF THE REGULATOR, DOFF THE FACE-
PIECE AND REPEAT DONNING STEPS 1 THROUGH 8 ABOVE.
IF LEAKAGE PERSISTS, DO NOT USE THE RESPIRATOR.
5. Proceed with use of respirator in accordance with your respiratory
protection program.
EVERY ENTRY INTO A CONTAMINATED OR UNKNOWN ATMO-
SPHERE SHOULD BE PLANNED TO ENSURE THAT THERE IS
SUFFICIENT AIR SUPPLY TO ENTER, CARRY OUT THE TASKS
REQUIRED AND RETURN TO A SAFE BREATHING AREA. THE
USER SHOULD CHECK THE REMOTE READING PRESSURE
GAUGE ON THE SHOULDER STRAP PERIODICALLY TO DE-
TERMINE THE RATE OF AIR CONSUMPTION. IN ANY EVENT,
THE USER MUST BE CERTAIN TO ALLOW SUFFICIENT AIR
FOR EGRESS FROM THE CONTAMINATED AREA. IF ENTRY
IS ATTEMPTED AFTER THE AIR HAS BEEN PARTIALLY CON-
SUMED (CYLINDER LESS THAN FULL), THE USER MUST BE
CERTAIN THAT THE REMAINING AIR WILL BE SUFFICIENT FOR
SAFETY.
Leave the contaminated or unknown atmosphere immediately
if the bell alarm actuates and, in a safe area, determine cause
of alarm. When air supply has been depleted, replace cylinder
following CYLINDER REPLACEMENT PROCEDURE.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Scott Safety 2216 PSI Operating & Maintenance Instructions

Type
Operating & Maintenance Instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI