TESCOM TE100 User manual

Type
User manual
1
1 2
Names and Functions of the Components
Air inlet
Do not place anything
in the inlet.
Battery lamp
[In regular use]
Extinguishes: Battery charged
Flash: Low battery level
[Charging in progress]
On: Now charging is in
progress.
Off: Charging is complete.
Air outlet
Do not place anything in the
outlet.
Photo head
Place this on your skin
during esthetic treatment.
Photo switch
Pressing this switch turns
on the power, starting the
photo head flashing pattern.
Pressing the switch again
turns off the power,
extinguishing the photo
head lamp.
Once the Cool switch is
pressed during operation,
the mode changes to Cool
Esthetic, extinguishing the
photo head lamp.
Nickel-Metal Hydride
Battery (built-in)
Body socket
Skin Cool Pat
Cool head
Placed on your skin during
esthetic treatment.
Cool Esthetic Power
lamp
Flashes when the Cool
switch is pressed, and lights
up when the preparation for
cooling has finished.
Cool switch
Pressing this switch turns
on the power, and the Cool
Esthetic Power lamp starts
flashing accordingly.
Pressing the switch again
turns off the power,
extinguishing the Cool
Esthetic Power lamp.
Once the Photo switch is
pressed during operation,
the mode changes to Cool
Esthetic, extinguishing the
Cool Esthetic Power lamp.
Accessories
List of Voltages and Plugs by Country
Power adapter Cap
Plug-to-
appliance
Power cord
Power plug
Household Use Only
Skin Cool Pat
Rated time
Charging time
Weight
Accessories
Nickel-Metal Hydride Battery (DC3.6V, 800mAh) 1set
Height 111 × Width 46 × Depth 40 mm (body)
Approx. 5 h
120 g
(body)
Cap, Power adapter, List
of Voltages and
Plugs by Country
Photo Esthetic:
5 min (automatic turn-off)
Cool Esthetic:
5 min (automatic turn-off)
Power consumption
Power supply
Cool Esthetic
Photo Esthetic
10 W when AC is used
2 W when AC is used
AC100-240 V 50/60 Hz
TE100
Power adapter
Part name
Part number
Dimensions
Body
Specifications
The standard time for charging is approx. 5 hours.
The body and power adapter may become slightly hot; this does
not indicate a failure.
A battery fully charged once is sufficient for about five sessions
each consisting of a 5-min Photo Esthetic period and a 5-min
Cool Esthetic period.
(The number of times may decrease, depending on the
conditions for use of the appliance, for example, how you clean
the appliance.)
Once the battery lamp is extinguished, unplug
the power adapter from the body and receptacle.
Make sure that the Cool switch/Photo switch is off.
Then, connect the power adapter to the
body and receptacle.
Do not push the power adapter’s plug-to-appliance into the
body’s socket with excessive force, or tilt it in a forced manner.
If you do so, the socket may break.
While battery charge is in progress, the Power switch lamp stays on continuously and is
extinguished upon completion.
Battery lamp
On: Now charging is
in progress.
Off: Charging is
complete.
Charging the Battery
1
1 2
Names and Functions of the Components
Air inlet
Do not place anything
in the inlet.
Battery lamp
[In regular use]
Extinguishes: Battery charged
Flash: Low battery level
[Charging in progress]
On: Now charging is in
progress.
Off: Charging is complete.
Air outlet
Do not place anything in the
outlet.
Photo head
Place this on your skin
during esthetic treatment.
Photo switch
Pressing this switch turns
on the power, starting the
photo head flashing pattern.
Pressing the switch again
turns off the power,
extinguishing the photo
head lamp.
Once the Cool switch is
pressed during operation,
the mode changes to Cool
Esthetic, extinguishing the
photo head lamp.
Nickel-Metal Hydride
Battery (built-in)
Body socket
Skin Cool Pat
Cool head
Placed on your skin during
esthetic treatment.
Cool Esthetic Power
lamp
Flashes when the Cool
switch is pressed, and lights
up when the preparation for
cooling has finished.
Cool switch
Pressing this switch turns
on the power, and the Cool
Esthetic Power lamp starts
flashing accordingly.
Pressing the switch again
turns off the power,
extinguishing the Cool
Esthetic Power lamp.
Once the Photo switch is
pressed during operation,
the mode changes to Cool
Esthetic, extinguishing the
Cool Esthetic Power lamp.
Accessories
List of Voltages and Plugs by Country
Power adapter Cap
Plug-to-
appliance
Power cord
Power plug
Household Use Only
Skin Cool Pat
Rated time
Charging time
Weight
Accessories
Nickel-Metal Hydride Battery (DC3.6V, 800mAh) 1set
Height 111 × Width 46 × Depth 40 mm (body)
Approx. 5 h
120 g
(body)
Cap, Power adapter, List
of Voltages and
Plugs by Country
Photo Esthetic:
5 min (automatic turn-off)
Cool Esthetic:
5 min (automatic turn-off)
Power consumption
Power supply
Cool Esthetic
Photo Esthetic
10 W when AC is used
2 W when AC is used
AC100-240 V 50/60 Hz
TE100
Power adapter
Part name
Part number
Dimensions
Body
Specifications
The standard time for charging is approx. 5 hours.
The body and power adapter may become slightly hot; this does
not indicate a failure.
A battery fully charged once is sufficient for about five sessions
each consisting of a 5-min Photo Esthetic period and a 5-min
Cool Esthetic period.
(The number of times may decrease, depending on the
conditions for use of the appliance, for example, how you clean
the appliance.)
Once the battery lamp is extinguished, unplug
the power adapter from the body and receptacle.
Make sure that the Cool switch/Photo switch is off.
Then, connect the power adapter to the
body and receptacle.
Do not push the power adapter’s plug-to-appliance into the
body’s socket with excessive force, or tilt it in a forced manner.
If you do so, the socket may break.
While battery charge is in progress, the Power switch lamp stays on continuously and is
extinguished upon completion.
Battery lamp
On: Now charging is
in progress.
Off: Charging is
complete.
Charging the Battery
3
3 4
Precautions for Use
If you apply to one of the following
categories, be sure to consult with a doctor.
Failure to follow these instructions may result in
accident or injury.
This appliance must not be used on any of
the following regions.
Failure to follow these instructions may result in
accident or injury.
A person with cardiac damage
A person with an acute (painful) illness
A person with a febrile disease
A person with abnormal blood pressure
A person with a communicable disease
A person with a tuberculous disease
A person with a malignancy
A person with facial pain
A person who is pregnant
During menstruation
A person with atopic dermatitis
A person with allergies
A person with particularly sensitive skin
A hemophiliac
Undergoing dental treatment
A person with a telangiectatic disease that is due to
long-term use of a steroid hormonal agent or due to
liver function disorder
A person who has consumed alcohol, taken a drug
or is very tired
A region that has beeen subjected to cosmetic surgery
Eye balls and upper eyelids
Wounds
Melanoderma of face
Mucosal regions (e.g. inside of mouth)
Inflamed regions due to comedo or pimples
Regions that have impairment of pain sensation or
disturbance of perception
Skin regions under which there is a metallic, plastic,
silicone, or other implant
Regions that have inflamed pigmented spots due to
itch, flush, physical stimulus, or other
Inflamed regions due to cosmetics or similar products
* Skin care with this appliance should be undertaken twice a day, as a guide, for each
esthetic function, and the time of use should be within 5 min for each esthetic function.
If you experience any problems with your skin or body, stop use of the appliance immediately
and consult with a medical specialist.
Failure to follow these instructions may result in accident or adverse effects.
Cleanse your face to wash off any makeup.
Wash the makeup off your face using a cleansing agent.
Do not use the appliance continuously for longer than 5 min to protect your skin from damage.
This appliance should be used on bare skin from which makeup has been removed.
If your skin is dry, apply a beauty lotion to your skin before using the appliance.
After applying the beauty lotion to your skin, use the appliance while your skin is not damp.
* Do not use any milky or gel-like lotion for this purpose.
WARNING
3
3 4
Precautions for Use
If you apply to one of the following
categories, be sure to consult with a doctor.
Failure to follow these instructions may result in
accident or injury.
This appliance must not be used on any of
the following regions.
Failure to follow these instructions may result in
accident or injury.
A person with cardiac damage
A person with an acute (painful) illness
A person with a febrile disease
A person with abnormal blood pressure
A person with a communicable disease
A person with a tuberculous disease
A person with a malignancy
A person with facial pain
A person who is pregnant
During menstruation
A person with atopic dermatitis
A person with allergies
A person with particularly sensitive skin
A hemophiliac
Undergoing dental treatment
A person with a telangiectatic disease that is due to
long-term use of a steroid hormonal agent or due to
liver function disorder
A person who has consumed alcohol, taken a drug
or is very tired
A region that has beeen subjected to cosmetic surgery
Eye balls and upper eyelids
Wounds
Melanoderma of face
Mucosal regions (e.g. inside of mouth)
Inflamed regions due to comedo or pimples
Regions that have impairment of pain sensation or
disturbance of perception
Skin regions under which there is a metallic, plastic,
silicone, or other implant
Regions that have inflamed pigmented spots due to
itch, flush, physical stimulus, or other
Inflamed regions due to cosmetics or similar products
* Skin care with this appliance should be undertaken twice a day, as a guide, for each
esthetic function, and the time of use should be within 5 min for each esthetic function.
If you experience any problems with your skin or body, stop use of the appliance immediately
and consult with a medical specialist.
Failure to follow these instructions may result in accident or adverse effects.
Cleanse your face to wash off any makeup.
Wash the makeup off your face using a cleansing agent.
Do not use the appliance continuously for longer than 5 min to protect your skin from damage.
This appliance should be used on bare skin from which makeup has been removed.
If your skin is dry, apply a beauty lotion to your skin before using the appliance.
After applying the beauty lotion to your skin, use the appliance while your skin is not damp.
* Do not use any milky or gel-like lotion for this purpose.
WARNING
How to Use
This product has two esthetic functions:
Step 1: Photo Esthetic
Photo Esthetic: Delivers light to the skin and supports skin elasticity.
Cool Esthetic: Tones up your pores by cooling.
Avoid using each of the esthetic functions more than twice (within 5 min for each time) a day.
When 5 min has passed since pressing the Photo or Cool switch, the power is turned off automatically.
The appliance can be used for up to 5 min.
When using the appliance around your eyes, close them to
protect them from glare.
Avoid looking directly at the light for an extended period of time.
Failure to follow these instructions may result in accident or injury.
The photo head lamp flashes slowly.
Press and hold down the Photo switch.
Remove the cap.
Photo flashing pattern
(concept)
Maximum, continuously
on (about 2 sec)
Gradually change to the
flash mode (about 1 sec)
Extinguished
Repeated
This appliance should be used on bare skin without makeup.
The appliance can be used for up to 5 min. The power is turned off
automatically 5 min after pressing the Photo switch.
Place the head gently in the center of a region in which you
are concerned about pores (e.g. nostril, cheek), and move
it around slowly.
At this time, consecutive short beeps [pit pit pit …] are generated to
indicate the shutdown.
Press the Photo switch again to turn off the photo head lamp.
The power is turned off automatically after a lapse of 5 min.
To interrupt the process,
WARNING
5
5 6
How to Use
Do not use this appliance for care around the eyes or ears.
(Failure to follow these instructions may result in accident or adverse effects.)
If your skin has an injury or wound, the appliance should not be
used under any circumstances.
(Failure to follow these instructions may result in skin problems or injury.)
Step 2: Cool Esthetic
The appliance can be used for up to 5 min, including the preparation time for cooling.
Do not continue to use the appliance on the same region beyond 1 sec.
(Failure to follow these instructions may result in skin damage or injury)
Cool head
Air inlet
Air outlet
If the cool head temperature seems to be too low, use
the appliance at a higher ambient temperature.
Remove the cap.
The Cool Esthetic Power lamp flashes.
Wait until the preparation for cooling finishes and the Cool
Esthetic Power lamp turns to the continuously on mode. (It
takes 60 sec for the preparation to finish.)
Press and hold down the Cool switch.
Remember that if the air inlet or outlet is blocked, the head will
not be cooled sufficiently.
While waiting for completion of the preparation,
do not block the air inlet or outlet.
While using the appliance, a cooling sound is generated; this does not indicate a failure.
While using the appliance, the appliance body becomes warm; this does not indicate a failure.
Once the Cool Esthetic Power lamp lights up, you can start
using the appliance. Check the cool head with your fingertip.
A short time after the power is turned off, the cool head and body
temperatures increase temporarily, this does not indicate failure.
Pressing the Cool switch again turns off the Cool Esthetic Power lamp,
stopping the cooling.
The power is turned off automatically after a lapse of 5 min.
At this time, consecutive short beeps [pit pit pit …] are generated to indicate the shutdown.
To interrupt the process,
This appliance should be used on bare skin without makeup.
To use the appliance on the same region, repeat placing the head
there for 1 sec and then releasing it from there for 1 sec.
The power is turned off automatically 5 min after pressing the Cool switch.
Place the head gently in the center of an area in which
you are concerned about pores (e.g. nostril, cheek),
and move it around slowly in a patting-like manner.
WARNING
CAUTION
How to use
Do not use the appliance in a location where it may be
subjected to splashing with water (e.g. bathroom) or in a
humid location. (Failure to follow these instructions may result
in shock or short circuit.) (Failure to follow these instructions may
result in shock or short circuit.)
[Using the Appliance with Alternating Current System]
[Cleaning]
Follow the instructions in “How to Use” (pages 4 to 5).
Start Photo or Cool Esthetic.
Plug the power adapter to the body and receptacle.
After completion of use, be sure to unplug the power adapter from the body and
receptacle.
To charge the battery subsequently,
Follow the instructions in “Charging the Battery” on page 2.
Make sure that the power is turned off and the power adapter has been removed.
Then start the cleaning.
Wipe dirt off the body using a soft dry cloth.
If it is difficult to remove dirt and grime from the body,
soak a soft cloth in a soap-and-water solution or a water-diluted
neutral detergent, and wring well. Then, use this cloth to wipe dirt
and grime off the body.
[Overseas use]
The low battery status is indicated by the battery lamp that flashes (when the power is
on) while consecutive short beeps [pit pit pit …] are generated for 10 sec, and the power
is turned off automatically.
-> Immediately charge the battery.
This product can be used with AC 100 to 240V power supply.
This product can be used with AC 100 to 240V power supply.
[Timing of charge] Battery lamp
WARNING
5
5 6
How to Use
Do not use this appliance for care around the eyes or ears.
(Failure to follow these instructions may result in accident or adverse effects.)
If your skin has an injury or wound, the appliance should not be
used under any circumstances.
(Failure to follow these instructions may result in skin problems or injury.)
Step 2: Cool Esthetic
The appliance can be used for up to 5 min, including the preparation time for cooling.
Do not continue to use the appliance on the same region beyond 1 sec.
(Failure to follow these instructions may result in skin damage or injury)
Cool head
Air inlet
Air outlet
If the cool head temperature seems to be too low, use
the appliance at a higher ambient temperature.
Remove the cap.
The Cool Esthetic Power lamp flashes.
Wait until the preparation for cooling finishes and the Cool
Esthetic Power lamp turns to the continuously on mode. (It
takes 60 sec for the preparation to finish.)
Press and hold down the Cool switch.
Remember that if the air inlet or outlet is blocked, the head will
not be cooled sufficiently.
While waiting for completion of the preparation,
do not block the air inlet or outlet.
While using the appliance, a cooling sound is generated; this does not indicate a failure.
While using the appliance, the appliance body becomes warm; this does not indicate a failure.
Once the Cool Esthetic Power lamp lights up, you can start
using the appliance. Check the cool head with your fingertip.
A short time after the power is turned off, the cool head and body
temperatures increase temporarily, this does not indicate failure.
Pressing the Cool switch again turns off the Cool Esthetic Power lamp,
stopping the cooling.
The power is turned off automatically after a lapse of 5 min.
At this time, consecutive short beeps [pit pit pit …] are generated to indicate the shutdown.
To interrupt the process,
This appliance should be used on bare skin without makeup.
To use the appliance on the same region, repeat placing the head
there for 1 sec and then releasing it from there for 1 sec.
The power is turned off automatically 5 min after pressing the Cool switch.
Place the head gently in the center of an area in which
you are concerned about pores (e.g. nostril, cheek),
and move it around slowly in a patting-like manner.
WARNING
CAUTION
How to use
Do not use the appliance in a location where it may be
subjected to splashing with water (e.g. bathroom) or in a
humid location. (Failure to follow these instructions may result
in shock or short circuit.) (Failure to follow these instructions may
result in shock or short circuit.)
[Using the Appliance with Alternating Current System]
[Cleaning]
Follow the instructions in “How to Use” (pages 4 to 5).
Start Photo or Cool Esthetic.
Plug the power adapter to the body and receptacle.
After completion of use, be sure to unplug the power adapter from the body and
receptacle.
To charge the battery subsequently,
Follow the instructions in “Charging the Battery” on page 2.
Make sure that the power is turned off and the power adapter has been removed.
Then start the cleaning.
Wipe dirt off the body using a soft dry cloth.
If it is difficult to remove dirt and grime from the body,
soak a soft cloth in a soap-and-water solution or a water-diluted
neutral detergent, and wring well. Then, use this cloth to wipe dirt
and grime off the body.
[Overseas use]
The low battery status is indicated by the battery lamp that flashes (when the power is
on) while consecutive short beeps [pit pit pit …] are generated for 10 sec, and the power
is turned off automatically.
-> Immediately charge the battery.
This product can be used with AC 100 to 240V power supply.
This product can be used with AC 100 to 240V power supply.
[Timing of charge] Battery lamp
WARNING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

TESCOM TE100 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI