ML Accessories FL8W User manual

  • Hello! I am an AI chatbot trained to assist you with the ML Accessories FL8W User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
IP
44
230V
50Hz
2
FL6&FL12
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
FL6W,FL6BKFL12W,FL12BK
SAFETY
Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
Pleaseisolatemainspriortoinstallation/maintenance
Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
ThisproductisClassIIdoubleinsulated
Thisproductisnondimmable
ThisproductisIP44rated
INSTALLATION
Providepowertotherequiredpointofinstallation.SuitableIPratedjunctionsboxesshouldbeusedwhere
required
Werecommendaninstallationheightof2.4m
RemovethebackpanelwiththeaidofaslottedscrewdriverseeFig1
Fig1(FL12WPBKshownintheimage)
Markthelocationofthefixingholes,anddrilltheholesensuringnottoinfringewithanyjoists,gasorwater
pipesorelectricalcables
Feedthecableviathecableentrypointonthebottomoftheluminaire
ConnecttheLive(brown),Neutral(blue)totheterminalblock(seeFig2)
3
Blue
Brown
220-240V
L
N
Knock-out
For AC power cable
entry (Optional)
15mins
1mins
5mins 10mins
10secs
TIME LUX
Timedurationcanbechangedfrom10secto15mins
Luxsettingcanbechangedfrom5lxtodaylight
ADJUSTABLEDETECTIONRANGE
Fig5
ThefieldofdetectioncanbeadjustedleftandrightbyrotatingringaroundthePIR
PositionsA,BandCareshownbutanypositionbetweenthemcanbeset(seeFig5)
Maximumrangeofupto10mwhenmountedataheightof2.4m
BLANKINGINSERTS
Fig6
Specificareaswithinthedetectionzonecanbeblockedifrequired(seeFig6)
Thedetectionanglecanberemovedin30°sections
WARNING
Thisproductmustbedisconnectedfromthecircuitifsubjectedtoanyhighvoltageorinsulationresistancetesting.
Irreparabledamagewilloccurifthisinstructionisnotfollowed.
GENERAL
Werecommendnottoinstallnearhighlyreflectivesurfacesorairvents.
Theunitdoesnothaveamanualoverridefacility.
Theunitshouldberecycledinthecorrectmannerwhenitreachestheendofitslife.Checklocalauthoritiesforwhere
facilitiesexist.
Cleanwithasoftdryclothonly,donotuseaggressivecleaningproductsorsolventswhichmaydamagethefitting.
A
B
C
C
B
A
10m
4
30°
/