ML Accessories FL8W User manual

Type
User manual
1
IP
44
230V
50Hz
2
FL6&FL12
Theseinstructionsshouldbereadcarefullyandretainedafterinstallationbytheenduserforfuturereferenceand
maintenance.
Theseinstructionsshouldbeusedtoaidinstallationofthefollowingproducts:
FL6W,FL6BKFL12W,FL12BK
SAFETY
Installationofthisluminaireshouldonlybecarriedoutbyaqualifiedelectricianorcompetentpersontothe
latestBuildingandcurrentIEEWiringRegulations(BS7671)
Pleaseisolatemainspriortoinstallation/maintenance
Checkthetotalloadonthecircuit(includingwhenthisluminaireisfitted)doesnotexceedtheratingofthe
circuitcable,fuseorcircuitbreaker
PleasenotetheIP(IngressofProtection)ratingofthisluminairewhendecidingthelocationforinstallation
ThisproductisClassIIdoubleinsulated
Thisproductisnondimmable
ThisproductisIP44rated
INSTALLATION
Providepowertotherequiredpointofinstallation.SuitableIPratedjunctionsboxesshouldbeusedwhere
required
Werecommendaninstallationheightof2.4m
RemovethebackpanelwiththeaidofaslottedscrewdriverseeFig1
Fig1(FL12WPBKshownintheimage)
Markthelocationofthefixingholes,anddrilltheholesensuringnottoinfringewithanyjoists,gasorwater
pipesorelectricalcables
Feedthecableviathecableentrypointonthebottomoftheluminaire
ConnecttheLive(brown),Neutral(blue)totheterminalblock(seeFig2)
3
Blue
Brown
220-240V
L
N
Knock-out
For AC power cable
entry (Optional)
15mins
1mins
5mins 10mins
10secs
TIME LUX
Timedurationcanbechangedfrom10secto15mins
Luxsettingcanbechangedfrom5lxtodaylight
ADJUSTABLEDETECTIONRANGE
Fig5
ThefieldofdetectioncanbeadjustedleftandrightbyrotatingringaroundthePIR
PositionsA,BandCareshownbutanypositionbetweenthemcanbeset(seeFig5)
Maximumrangeofupto10mwhenmountedataheightof2.4m
BLANKINGINSERTS
Fig6
Specificareaswithinthedetectionzonecanbeblockedifrequired(seeFig6)
Thedetectionanglecanberemovedin30°sections
WARNING
Thisproductmustbedisconnectedfromthecircuitifsubjectedtoanyhighvoltageorinsulationresistancetesting.
Irreparabledamagewilloccurifthisinstructionisnotfollowed.
GENERAL
Werecommendnottoinstallnearhighlyreflectivesurfacesorairvents.
Theunitdoesnothaveamanualoverridefacility.
Theunitshouldberecycledinthecorrectmannerwhenitreachestheendofitslife.Checklocalauthoritiesforwhere
facilitiesexist.
Cleanwithasoftdryclothonly,donotuseaggressivecleaningproductsorsolventswhichmaydamagethefitting.
A
B
C
C
B
A
10m
4
30°
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4