READ THIS FIRST
Please pay attention to the following inallation and safety recommendations:
- Read the inallation manual before inalling this syem.
NOTE! Please make sure your inallation location has enough room for the RO Syem and Water Storage Tank.
Make sure your inall location has access to a power outlet for the Ultraviolet Sterilizer.
Incoming Water
Incoming water pressure mu be between 40 PSI and 80 PSI. If your water pressure is under 40 PSI you
will need a booer pump for your syem. If your water pressure is above 80 PSI you will need a pressure
regulator for your syem. Te your water pressure occasionally to make sure the syem is performing. If your
water is microbiologically unsafe or of unknown quality do not use this syem without adequate disinfection
before or after the syem. Extremely hot or cold incoming water will damage the syem and cannot be used.
Leaks
The Leak Stop Valve mu be inalled. Inspect all connections after the inallation to make sure no leaks
occur, wait until after the syem is pressurized (turned on) to inspect again. Check syem occasionally
after inallation or maintenance to make sure no leaks have developed. Inall the syem in a location with
adequate drainage.
General
This RO Syem unit is for climate controlled indoor use only. Exposure to overly high or low temperature
ranges will damage the unit. Follow all of your ate and local laws and codes regarding plumbing even if they
dier from what is ated in this manual. If your ate law requires it or you prefer to we recommend using
a professional licensed inaller or plumber who meets the requirements of this syem. All O-Rings, ttings,
lter caniers, and teon tape wear out after a certain period of time. The lifetime of your components are
subject to change with the quality of the water supplied. Do not handle an unwrapped lter directly with your
bare hands as this can cause early lter failure. Use appropriate eye and face protection when performing any
drilling. The Ultraviolet Sterilizer requires access to a 110V power outlet; make sure you have safe access to
power for this syem. Do not look directly at UV Bulb without protection!
Maintenance
The owner/user is obligated to properly maintain the RO Syem when necessary, at lea every 1 year. This
includes the following:
- Replace the O-rings on the lter housings, membrane housing, ttings, and lter cartridges.
- Replace any connectors and lter housings with proper replacement parts.
- Sanitize your syem as often as needed (how often changes with the prole of your area’s incoming water).
- Always use proper replacement lter cartridges with the correct size and length replacements.
- Replace the Teon Tape on all threaded connections and ttings.
Copyright © 2018 by Express Water Inc.
All rights reserved. No part of this publication may be reproduced, diributed, or transmitted in any form or by any
means, including photocopying, recording, or other electronic or mechanical methods, without the prior written
permission of the publisher, except in the case of brief quotations embodied in critical reviews and certain other
noncommercial uses permitted by copyright law.
Conditions