Flow Vision Administrator’s Guide 5
53-1002999-01
Flows
1
Numbers of flows supported
Flow Vision supports a maximum of 512 flows on chassis-based platforms and a maximum of
128 flows on fixed-port platforms. However, there is a combined limit from all features of 64 flows
(including static flows, root flows, and sub-flows, whether active or inactive) for any one port. In
addition, there are individual limits for each Flow Vision feature; Table 4 lists these limits.
A verification is done for each flow when it is created or activated to ensure that there is no
identical flow active. Refer to the limitations section of each feature for additional feature-specific
restrictions.
Flow learning
Flow Vision can create a learned flow by using an asterisk (*) for the source device, the destination
device, or both devices. This allows you to discover what flows are active on a port without having to
identify all the devices. Each Flow Vision feature uses learning as follows:
• Flow Monitor can learn all the source device and destination device pairs passing through the
ingress or egress port defined in a flow. Learning is not supported for Flow Monitor flows
defined using the lun, -frametype, or -bidir parameters. Refer to “Learning in Flow Monitor
flows” on page 12 for additional information.
• Flow Generator can generate traffic to or from every source or destination device that shares
the zone with the ingress or egress port defined in a flow. Refer to “Learning in Flow Generator
flows” on page 34 for additional information.
• Flow Mirror can capture all the source device and destination device pairs passing through the
ingress or egress port defined in a flow. Learning is supported for Flow Mirror flows defined
using the lun, -frametype, or -bidir parameters. Refer to “Learning in Flow Mirror flows” on
page 51 for additional information.
Flow Vision uses an asterisk (*) to indicate a learned flow. When you enter an asterisk as part of
the command, you must enclose it in double quotes (“*”).
Learning source device (srcdev) or destination device (dstdev) values is only supported on
16 Gbps-capable Fibre Channel ports.
Viewing flows
To display all Flow Vision flows, enter flow --show. To display all flows for a specific feature, enter
flow --show -feature featurename. To display the definition for a specific flow, enter flow --show
flowname -feature featurename. When you run flow --show with a flow name, then only the flow
definition for the specified flow is displayed. If the feature is also specified, feature-specific data is
displayed for the specified flow name. For root and static flows, this command shows the
Source ID-Destination ID pairs and the cumulative frame count on the ingress or egress port
specified in the flow definition.
TABLE 4 Feature-specific flow count restrictions in Flow Vision
Feature Limit to number of flows
Flow Monitor Up to 64 active flows per port, including static flows, root flows, and sub-flows.
Flow Generator Up to 4 active flows per port, including static flows, root flows, and sub-flows.
Flow Mirror One active flow per port.