Dell Basic PDU Owner's manual

Type
Owner's manual

Dell Basic PDU offers 48 IEC 320-C13 outlets. The unit has a 5-pin, 3f, IEC60309 plug, 530P6S, or 532P6S. An input voltage of 346-415 VAC ± 10% is acceptable, providing a maximum output current of 10A per outlet. It can operate in temperatures ranging from 0 to 50°C (32 to 122°F) and is compliant with safety approvals such as UL(C-UL), TUV-GS, and ROHS.

Dell Basic PDU offers 48 IEC 320-C13 outlets. The unit has a 5-pin, 3f, IEC60309 plug, 530P6S, or 532P6S. An input voltage of 346-415 VAC ± 10% is acceptable, providing a maximum output current of 10A per outlet. It can operate in temperatures ranging from 0 to 50°C (32 to 122°F) and is compliant with safety approvals such as UL(C-UL), TUV-GS, and ROHS.

t
Dellt Basic Rack
Power Distribution Unit (PDU)
DELLB0007
Product Overview and Specifications
English Français Deutsch
Ðóññêèé Español Simp Chinese
Trad Chinese Korean Japanese
www.dell.com | support.dell.com
Dellt Basic Rack
Power Distribution Unit (PDU)
DELLB0007
Product Overview and Specifications
English
www.dell.com | support.dell.com
Product Overview and Specifications
The Dell Basic Rack PDU distributes power to the devices in the rack.
O
UTLETS—The Rack PDU has (48) IEC 320-C13 outlets.
P
OWER CORD—The Rack PDU attached power cord terminates with a 5-pin, 3f, IEC60309 plug, 530P6S or 532P6S.
DELLB0007
Electrical
Input connection NA: IEC60309-30 A plug; INTL: IEC60309-32 A plug
Acceptable input voltage 346–415 VAC ± 10%
Maximum input current (phase) NA: 30 A (24 A UL(C-UL) derated); INTL: 32 A
Input frequency 50/60 Hz
Output voltage 200–240 VAC ± 10%
Output connections (48) IEC 320-C13
Maximum output current (outlet) C13: 10 A
Maximum output current (phase) NA: 30 A (24 A UL(C-UL) derated); INTL: 32 A
Physical
Dimensions
(H
W D)
203.5 5.5 9.3 cm
(80.1
2.2 3.7 in)
Shipping dimensions
(H
W D)
225.0 20.0 17.0 cm
(88.6
7.9 6.7 in)
Weight 6.3 kg (13.9 lb)
Shipping weight 8.8 kg (19.4 lb)
Environmental
Maximum elevation
(above MSL)
Operating
Storage
0 to 3048 m (0 to 10,000 ft)
0 to 15 240 m (0 to 50,000 ft)
Temperature
Operating
Storage
0 to 50°C (32 to 122°F)
-15 to 60°C (5 to 140°F)
Humidity
Operating
Storage
5 to 95% non-condensing
5 to 95% non-condensing
Compliance
Safety approvals UL(C-UL), TUV-GS, TUV-S Mark, IRAM, South Africa (LoA),
GOST, SONCAP, KC, Australia (ESV)
ROHS Dell 6T198
EU DIRECTIVE 2002/95/EC-latest revision
Information in this document is subject to change without notice.
© 2010–2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in
trademarks and trade names other than its own.
Model DELLB0007
02/2012 • 164201952 Rev 3
www.dell.com | support.dell.com

Dell  PDU 。
 -  PDU (48) IEC 320-C13 
 -  PDU 5 3fIEC60309 、530P6S 532P6S
DELLB0007

 : IEC60309-30 A IEC60309-32 A
 346-415 VAC ± 10%
!(#) : 30 A (24 A UL(C-UL) %&) 32 A
'( 50/60 Hz
200-240 VAC ± 10%
 (48) IEC 320-C13
!() C13: 10 A
!(#) : 30 A (24 A UL(C-UL) %&) 32 A

)
(*
+)
203.5 5.5 9.3 cm
(80.1
2.2 3.7 ,)
-)
(*
+)
225.0 20.0 17.0 cm
(88.6
7.9 6.7 ,)
./ 6.3 kg (13.9 0)
-./ 8.8 kg (19.4 0)

!12
(134*5)
6
7
0 8 3048 m (0 8 10,000 ,))
0 8 15 240 m (0 8 50,000 ,))
95
6
7
0 8 50°C (32 8 122°F)
-15 8 60°C (5 8 140°F)
:5
6
7
5 8 95% ;!"
5 8 95% ;!"

#$<= UL(C-UL), TUV-GS, TUV-S Mark, IRAM, %> (LoA), GOST,
SONCAP, KC, ?&' (ESV)
“()*+@A,.
BC/1DEF4”
ROHS
Dell 6T198
GHF4 2002/95/EC-!IJ
, !"。
© 2010–2012 Dell Inc. $%&'。
KL Dell Inc. 547M,8O:;<PQRS=,。
.B>T: DellDELLUTV Dell Inc. >T
?W@.BBD>T>FGXYFXZ[>TGX\&HB。 Dell Inc. JK])^_>T>GX,KZ;<\&。
LMDELLB0007
02/2012 · 164201952 N`J 3
www.dell.com | support.dell.com

Dell  PDU 。

-  PDU (48) IEC 320-C13 

-  PDU  5 3fIEC60309 530P6S 532P6S
DELLB0007

! ": IEC60309-30 A ;%: IEC60309-32 A 
! 346-415 VAC ± 10%
&!(() ": 30 A (24 A UL(C-UL) *+)%: 32 A
!,- 50/60 Hz
! 200-240 VAC ± 10%
! (48) IEC 320-C13
&!() C13: 10 A
&!(() ": 30 A (24 A UL(C-UL) *+)%: 32 A

./
(0
1 2)
203.5 5.5 9.3 cm
(80.1
2.2 3.7 3/)
4!./
(0
1 2)
225.0 20.0 17.0 cm
(88.6
7.9 6.7 3/)
56 6.3 kg (13.9 7)
4!56 8.8 kg (19.4 7)

&89(8:;0<)
=
>
0 ? 3048 m (0 ? 10,000 3.)
0 ? 15 240 m (0 ? 50,000 3.)
@<
=
>
0 ? 50°C (32 ? 122°F)
-15 ? 60°C (5 ? 140°F)
A<
=
>
5 ? 95% B
5 ? 95% B

CD UL(C-UL), TUV-GS, TUV-S Mark, IRAM, E (LoA), GOST,
SONCAP, KC, F (ESV)
G!H"#$IJK%L&
ROHS
Dell 6T198
MNL& 2002/95/EC-&OP
, 。
© 2010–2012 Dell Inc. "#$%&。
QRST'(U;V)X*+,YZ[\5]
.^/_: Dell DELL _`a Dell Inc. /_
b0.^12/_c/d3e,4Lfg_`h51。 i1fj6,ST'(7f12/_c/d3e+,hk
8lDELLB0007
02/2012 · 164201952 9mP 3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Dell Basic PDU Owner's manual

Type
Owner's manual

Dell Basic PDU offers 48 IEC 320-C13 outlets. The unit has a 5-pin, 3f, IEC60309 plug, 530P6S, or 532P6S. An input voltage of 346-415 VAC ± 10% is acceptable, providing a maximum output current of 10A per outlet. It can operate in temperatures ranging from 0 to 50°C (32 to 122°F) and is compliant with safety approvals such as UL(C-UL), TUV-GS, and ROHS.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI