Greenheck 462831 APEX Curbs Operating instructions

Category
Hardware cooling accessories
Type
Operating instructions

Greenheck 462831 APEX Curbs

Greenheck 462831 APEX Curbs are designed to provide a secure and efficient way to connect ductwork to a roof. They are made of durable galvanized steel and feature a variety of convenient features.

Key Features:

  • 12-inch high curb
  • 92-inch length
  • 42.75-inch supply end outer channel
  • 45.12-inch supply end inner channel
  • 72.87-inch exhaust side channel
  • 61.25-inch end base outer channel
  • 57-inch end base inner channel
  • 92-inch center channel
  • 88.25-inch adapter end channel
  • 36.75-inch adapter side channel
  • Includes all necessary hardware for assembly

Greenheck 462831 APEX Curbs

Greenheck 462831 APEX Curbs are designed to provide a secure and efficient way to connect ductwork to a roof. They are made of durable galvanized steel and feature a variety of convenient features.

Key Features:

  • 12-inch high curb
  • 92-inch length
  • 42.75-inch supply end outer channel
  • 45.12-inch supply end inner channel
  • 72.87-inch exhaust side channel
  • 61.25-inch end base outer channel
  • 57-inch end base inner channel
  • 92-inch center channel
  • 88.25-inch adapter end channel
  • 36.75-inch adapter side channel
  • Includes all necessary hardware for assembly
STEP 1: Unpack and Inspect Parts
Tools Recommended for Assembly
Cordless drill
5
/16 in. Nut setter
9
/16 in. Nut setter
Open or Closed
9
/16 in. wrench
Awl — for hole alignment
PART # 462831
April 2007
®
Roof Curb and Duct Adapter
Model: APEX-200
ASSEMBLY INSTRUCTIONS
Part Description Qty P/N Length
Roof Curb Kit
12 in. high 1 852212
1. End Channel 2 708908 92.00 inches
2. Supply End Outer Channel 2 708909 42.75 inches
3. Supply End Inner Channel 2 708911 45.12 inches
4. Exhaust Side Channel 2 708912 72.87 inches
5. End Base Outer Channel 2 708914 61.25 inches
6. End Base Inner Channel 2 708913 57.00 inches
7. Center Channel 4 708910 92.00 inches
Duct Adapter (12 in. high curb)
8. Adapter End Channel 3 711252 88.25 inches
9. Adapter Side Channel 4 711253 36.75 inches
Hardware Kit (for curb & duct adapter) 1 852636
3
/8-16 x
3
/4 Serrated Flange Bolts
40 415459
3
/8-16 x
3
/4 Serrated Flange Nuts
40 415457
Screws, SMS (A) 12 x 0.625 (IHH) 35 415180
2
STEP 2: Assemble Duct Adapters
Hardware Required: (16) Screws, SMS (A) 12 x 0.625 (IHH)
(4) Adapter Side Channels
(3) Adapter End Channels
(1) Center Channel
Instructions: See Exhaust and Supply Duct Adapter Assembly for positioning the
Adapter Side and End Channels.
Align the holes and fasten as shown.
End and side channels
fasten together, as shown.
Side and center
channels fasten
together, as shown.
End
STEP 3: Assemble Supply End Section
Hardware Required: (12)
3
/8-16 x
3
/4 Serrated Flange Bolts
(12)
3
/8-16 x
3
/4 Serrated Flange Nuts
(4) Screws, SMS (A) 12 x 0.625 (IHH)
(1) End Channel
(2) Supply End Outer Channels
(2) Supply End Inner Channels
(1) Supply Duct Adapter Assembly (see Step 2)
Instructions: Position Channels as shown in Supply End Asembly
Align the holes and fasten as illustrated below.
Exhaust Duct Adapter
Assembly
Supply Duct Adapter
Assembly
1
3
2
2
Supply End Assembly
9
8
7
9
8
8
Supply Duct Adapter
3
7
5
STEP 4: Assemble Exhaust Center Section
Hardware Required: (1) Exhaust Duct Adapter
(2) Exhaust Side Channels
(8) Screws, SMS (A) 12 x 0.625 (IHH
Instructions: See Exhaust Center Assembly for positioning the Exhaust Duct Adapter and
Exhaust Side Channels.
Align the holes and fasten as shown.
STEP 5: Assemble End Base Section
Hardware Required: (18)
3
/8-16 x
3
/4 Serrated Flange Bolts
(18)
3
/8-16 x
3
/4 Serrated Flange Nuts
(1) End Channel
(2) End Base Outer Channels
(2) End Base Inner Channels
(2) Center Channels
(1) Exhaust Center Section (see Step 4)
Instructions: Position Channels as shown in Exhaust Center and End Base Assembly
Align the holes and fasten as illustrated below.
4
Exhaust Center
Assembly
Exhaust Center and End Base
Assembly
1
5
6
6
#462831 IOM APEX Curb
Rev. 2, April 2007
Copyright © 2007 Greenheck Fan Corp.
7
STEP 6: Final Assembly
Hardware Required: (6)
3
/8-16 x
3
/4 Serrated Flange Bolts
(6)
3
/8-16 x
3
/4 Serrated Flange Nuts
(1) Center Channel
(1) Exhaust Center and End Base Assembly (see Step 5)
(1) Supply End Section (see Step 3)
Instructions: Position Channels as shown in Final Assembly
Align the holes and fasten as illustrated below.
Curb Dimensions
Final Assembly
92.00 in.
283.50 in.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Greenheck 462831 APEX Curbs Operating instructions

Category
Hardware cooling accessories
Type
Operating instructions

Greenheck 462831 APEX Curbs

Greenheck 462831 APEX Curbs are designed to provide a secure and efficient way to connect ductwork to a roof. They are made of durable galvanized steel and feature a variety of convenient features.

Key Features:

  • 12-inch high curb
  • 92-inch length
  • 42.75-inch supply end outer channel
  • 45.12-inch supply end inner channel
  • 72.87-inch exhaust side channel
  • 61.25-inch end base outer channel
  • 57-inch end base inner channel
  • 92-inch center channel
  • 88.25-inch adapter end channel
  • 36.75-inch adapter side channel
  • Includes all necessary hardware for assembly