CAME C-BXE24 Owner's manual

Type
Owner's manual
#!-%
CBX
AUTOMATION FOR INDUSTRIAL AND
RESIDENTIAL ENTRANCES
INSTALLATION MANUAL
All the data and information contained herein is considered subject to change at any time and at our discretion
2
ENGLISH
2.1 Destination
1 Legend
This symbol indicates sections to be read with particular care.
This symbol indicates sections concernig safety
This symbol indicates notes to communicate to users.
4.1 Gearmotor
All gearmotors are designed and built by CAME CANCELLI AUTOMATICI S.p.A. in compliance with the prevailing safety regulations.
Guaranteed for 24 months unless tampered with.
The enclosure is made up of a part in aluminium alloy inside of which the non-reversible, electromechanical gearmotor operates,
and partly in ABS plastic that houses the terminals for the electrical wiring.
The CBX series has several versions depending on the type of use - residential, condominium or industrial - with mechanical end
stop or with an encoder system (see para. 2.3 Fields of use).
The complete line:
Gearmotor 230V A.C. with encoder and control boards
001C-BXE Gearmotor 230V A.C. with encoder
002 ZCX10 - Control board
002 ZCX10C - Control board with safety block and command buttons
Gearmotor 24V A.C. with encoder and control boards
001C-BXE Gearmotor 24V A.C. with encoder
002 ZL80 -Control board
002 ZCX80C - Control board with safety block and command buttons
002 BN1 - Board for connecting 2 emergency batteries (12V - 1.2Ah)
The following standard were complied with for this product: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.
2 Destination and use applications
The CBX series gearmotor was designed to automate chiefl y sectional doors with direct transmission on the shaft using springs
or with chain drive; however, the CBX can also be used for sliding and folding doors with the respective accessories.
Uses other than the ones described above and installations using methods other than those shown in this technical
manual are considered prohibited.
3 Standard followed
4 Description
2.2 Use applications
For sectional doors with direct transmission: door height up to 5.5 m;
Speed* 7.15 m/1’ with cable winder drum ~Ø 105 mm;
Speed* 9.3 m/1’ with cable winder drum ~Ø 138 mm.
For sectional doors with chain drive: door height up to 8.5 m;
Speed* 9.15 m/1’ with cable winder drum ~Ø 208 mm.
For sliding and folding doors: door width up to 5.5 m for C-BXE / C-BXE24 / C-BXET;
door width up to 11 m for C-BX / C-BXT.
wing weight 1000 kg max.
* The speed varies depending on the diameter of the drum; in particular, models of cable winder drums used by the main sectional
door manufacturers in the specifi c dimensions were inserted into the descriptions.
2.3 Fields of use
C-BX / C-BXE Residential - Condominium - Industrial
C-BXE24 Residential - Condominium
C-BXT / C-BXET Industrial
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY
“THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS”
3
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
#!-%
4.2 Parts description
1 - Gearmotor
2 - Release handle
3 - Lower cap
4 - Protection cover
GEARMOTOR UNIT
ACCESSORIES
1 - C001 - Winch for manually moving sectional doors
2 - C002 - Pendulum release system
3 - C003 - Chain tightener transmission system and brackets
for sliding doors
4 - C004 - Chain tightener transmission system and brackets
for folding doors
5 - C005
- Chain drive system for sectional doors
6 - C006 - Package of two brackets for sectional doors
7 - C007/8 - Adapter for sectional doors
8 - CMS - Release handle with personalized key
9 - CGP - Chain guide with protective guard
10 - CCT - Simple 1/2” chain
11 - CGIU - Coupling for 1/2” chain
3
4
1
2
1
2
9
3
4
5
6
11
#!-%
2
8
10
7
Gearmotor 230V / 400V three-phase with encoder and control boards
001C-BXET - Gearmotor 230V/400V A.C. with encoder
002 ZT5 - Control board
002 ZT5C - Control board with safety block and command buttons
Gearmotor 230V A.C. with mechanical end-stop and control boards
001C-BX - Gearmotor 230V A.C. with mechanical end-stop
002 ZC3 - Control board
002 ZC3C - Control board with safety block and command buttons
Containers and electrical cards for gearmotors 230V
001S4339 - Container
001S4339C – Container with safety release and command buttons
001S4340 - Container
001S4340C – Container with safety release and command buttons
003 ZC5 - Basic electrical card
003 ZM2 - Multi-function electrical card
Gearmotor 230/400V three-phase with mechanical end-stop and control boards
001C-BXT - Gearmotor 230V/400V A.C. three phase with mechanical end-stop
002 ZT6 - Control board
002 ZT6C - Control board with safety block and command buttons
The CBX series comes with the following complementary accessories:
001 CMS - Release handle with personalized key and return cord (7 m long);
001 CGP - Chain guide with protective guard for industrial doors;
009 CCT - Simple 1/2” chain for sliding or folding doors;
009 CGIU - Coupling for 1/2” chain;
001 C001 - Winch for manually moving sectional doors;
001 C002 - Pendulum release system;
001 C003 - Chain tightener transmission system and brackets for sliding doors;
001 C004 - Chain tightener transmission system and brackets for folding doors;
001 C005 - Chain drive system for sectional doors with heights over 5.5 m;
001 C006 - Package of two brackets for sectional doors (specifi c for direct transmission applications);
001 C007/8 - Adapter for sectional doors con Ø 25 mm post (C007) or Ø 40 mm post (C008);
Important! Make sure that the control and safety equipment and accessories are CAME original. Only CAME products are gua-
ranteed to make the system easy to use and maintain.
All the data and information contained herein is considered subject to change at any time and at our discretion
4
ENGLISH
5.1 Preliminary checks
Before proceeding with the installation, it is necessary to:
• The gearmotor must be installed in an area protected from shocks; the anchoring surface must be solid; and appropriate parts
(screws, plugs, etc) must be used to anchor the gearmotor to the surface;
• Provide for suitable omnipolar disconnection device with more than 3 mm between contacts to section power supply.
• Connections inside the case made for protection circuit continuity are allowed as long as they include additional insulation
with respect to other internal drive parts.
• Install suitable tubes and ducts for electric cable passage to guarantee protection against mechanical damage.
• The structure of the door must be sufficiently sturdy, the hinges must be efficient and there must be no friction between fixed
or mobile parts;
• Check the presence of a mechanical end-stop during opening and closing.
Installation must be carried out by expert qualified personnel and in full observance of regulations in force.
5 Installation
SECTIONAL DOORS SLIDING DOORS
FOLDING DOORS
4.4 Size measurements
Measurements in mm
4.3 Technical information
C-BX / C-BXE GEARMOTOR
Power supply panel: 230V A.C. 50/60Hz
Motor power supply: 230V A.C. 50/60Hz
Absorption*: 3A
Rated power*: 450W
Max. torque*: 60 Nm
Reduction ratio: 1/67.45
Drive shaft revolutions: 34(CBX)/20.5(CBXE)
Motor revolution speed: 21.5 rpm
Operative intermittence: 30%
Protection level: IP54
Weight: 15 kg
Working time:
#
#
C-BXE24 GEARMOTOR
Power supply panel: 230V A.C. 50/60Hz
Motor power supply: 24V D.C.
Absorption*: 9A max.
Rated power*: 240W
Max. torque*: 25 Nm
Reduction ratio: 1/67,45
Drive shaft revolutions: 20,5
Motor revolution speed: 26,5 rpm
Operative intermittence: intensive service
Protection level: IP54
Weight: 15 kg
Working time:
C-BXT / C-BXET GEARMOTOR
Power supply panel: 230-400V A.C. - 50/60Hz
Motor power supply: 230-400V A.C.-50/60Hz
Absorption*: 2,5A
Rated power*: 780W
Max. torque*: 80 Nm
Reduction ratio: 1/67,45
Drive shaft revolutions: 34(CBXT)/20,5(CBXET)
Motor revolution speed: 21,5 rpm
Operative intermittence: intensive service
Protection level: IP54
Weight: 15 kg
Working time:
#
#
#
#
* Values relating to the designated electrical board
#!-%
2




5
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
5.3 Cable list and minimun thickness
Connections Type of cable Length of cable 1 < 10 m Length cable 10 < 20 m Length cable 20 < 30 m
230/400V 3F power supply
FROR CEI
20-22
CEI EN
50267-2-1
4G x 1,5 mm
2
4G x 2,5 mm
2
4G x 4 mm
2
230V 2F power supply 3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
230/400V 2F/3F power supply motor 4G x 1,5 mm
2
4G x 1,5 mm
2
4G x 1,5 mm
2
24V power supply motor 2 x 1 mm
2
2 x 1,5 mm
2
2 x 2,5 mm
2
24V - 230V flashing lamp 2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photoelectric TX 2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photoelectric RX 4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
24V power supply accessory 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control button 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
End stop 3 x 0,5 mm
2
3 x 1 mm
2
3 x 1,5 mm
2
Encoder connection 2402C 22AWG max. 30 m
Antenna connection RG58 max. 50 m
N.B.: An evaluation of the size of the cables with lengths other than the data in the table must be made based on the effective ab-
sorption of the connected devices, according to the instructions indicated by the CEI EN 60204-1 standards.
For connections that require several loads on the same line (sequential), the size given on the table must be re-evaluated based on
actual absorption and distances.
28
48
48
28
1 - Gearmotor
2 - Control panel with push-buttons
3 - Radio receiver
4 - Flaching light indicating movement
5 - Antenna
6 - Safety photocells
7 - Gearmotor release
5.2 Tools and materials
Make sure all tools and materials necessary are within reach to install the edge in maximum safety, according to regulations in
force. The following figure illustrates the minimum equipment for the installer.
All the data and information contained herein is considered subject to change at any time and at our discretion
6
ENGLISH
5.4 Installing the automation on sectional doors
The following applications are only examples, as the space for installing the ratiomotor and accessories varies accord-
ing to obstructions. It is thus up to the system installer to select the most suitable solution.
C006
Fig.2
VERTICAL APPLICATION
HORIZONTAL APPLICATION
CAME
1
2
Fig.1
DIRECT TRANSMISSION - The
CBX ratiomotor is supplied
ready for installation with a
direct action on the door springs
shaft, with a shaft diameter of 1
inch (fi g. 1); for special volume
requirements, it is also possible
to install it horizontally (fi g. 2)
but for both cases use accessory
(Art. C006).
1) Before securing the ratiomotor, open the protection cover to facilitate
post-assembly operations.
2) Insert the ratiomotor on the spring pole using the handle on the
ratiomotor.
7
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
#!-%
2
1
2
3
1
2
A
B
Fig.3
3) Manually release the ratiomotor by turning the rod clockwise
and move the door to make the pole cavity coincide with that of the
ratiomotor’s cable shaft.
4) Insert tongue A or B depending on the
type of shaft (see fi g. 3) between the two
cavities, insert the bushing on the pole and
secure with the grub screw.
5) Assemble the brackets (Art. C006) and secure them (avoid-
ing blocking them) to the ratiomotor with the supplied screws.
6) Secure the brackets on the wall with suitable screws chosen
according to the shape of the wall to secure the brackets onto
the ratiomotor.
SOLID SHAFT
HOLLOW SHAFT
All the data and information contained herein is considered subject to change at any time and at our discretion
8
ENGLISH
CHAIN TRANSMISSION
- Installations on sectional
doors higher than 5.5 m, for
this type of application you
must use the accessory (Art.
C005).
H > 5.5 m.
CAME
1
2
4) Secure the fi xing bracket to the ratiomotor with the supplied screws.
1
2
1) Before securing the ratiomotor, open the protection cover to facilitate
post-assembly operations.
2) Insert tongue A or B (see fi g.1) into the cavity
of the sprung pole, then insert toothed crown Z40
onto the pole opposite the tongue and secure it
with the grub screw.
3) Insert tongue A into the cavity of the pinion toothed sprocket shaft Z26, insert the
pinion, into the motor cable shaft and secure it with a screw UNI 5933 M6x16 and washer
from the opposite side.
A
B
Fig.1
C005
SOLID SHAFT
HOLLOW SHAFT
9
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
8) Then secure
the ratiomotor’s
xing bracket with
appropriate screws
chosen according to
the shape on the wall,
being sure that the two
toothed crowns are
perpendicular to each
other.
1
1
1
3
2
5) Unite the two ends of the chain with the coupling and
insert it onto the toothed crown Z40 leaving it hanging.
6) Anchor the ratiomotor’s shaft pinion to the hanging chain.
7) Release the ratiomotor by hand by turning the rod clockwise.
All the data and information contained herein is considered subject to change at any time and at our discretion
10
ENGLISH
5.5 Installing the automation on sliding doors
DOORS WITH ONE OR TWO WINGS - For
installations with sliding gates/doors having
one or two wings, you must use the acces-
sory C003 (transmission system for sliding
gates).
+
+
1) Before securing the ratiomotor, open the protection cover to facilitate
post-assembly operations.
1
2
3
2) Assemble the two fi xing brackets and secure them to the ratiomotor.
3) Insert the tongue into the cavity of the toothed pinion’s shaft Z26,
insert the pinion into the motor cable shaft and secure it with a screw
(UNI 5933 M6x16) and washer from the opposite side.
4) Secure the assembly above to the right or left of the door
using suitable items chosen according to the wall’s shape.
C003
CCT CGIU
CAME
1
2
11
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
5) Secure the chain-tensioning transmission from the opposite side
of the ratiomotor, in line with the pinion.
CAME
R
1
2
3
9) Secure the appropriate attachments (brackets and plates) fi rst
to the chain and then to the wings.
6) Insert the ½ inch chain (CCT) with a length of twice
distance A.
7) Unite the two ends with a coupling (CGIU).
8) Adjust the chain’s tension with the
transmission’s screw and then tighten the nuts.
1
2
A
All the data and information contained herein is considered subject to change at any time and at our discretion
12
ENGLISH
+
+
FOLDING DOORS - For installations with doors
having more than one wing, you must use ac-
cessory C004 (transmission system for folding
doors).
1) Before securing the ratiomotor, open the protection cover to facilitate
post-assembly operations.
2) Assemble the two fi xing brackets and secure them to the ratiomotor.
3) Insert the tongue into the cavity of the toothed pinion’s shaft
Z26, insert the pinion into the motor cable shaft and secure it with a
screw (UNI 5933 M6x16) and washer from the opposite side.
1
2
3
4) Secure the assembly with suitable elements, chosen
according to the shape of the wall.
C004
CCT CGIU
CAME
1
2
13
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
CAME
R
1
2
3
1
2
A
5) Secure the chain-tensioning
transmission from the opposite
side of the ratiomotor in line with
the pinion.
6) Insert the ½ inch chain (CCT) with a length of twice
distance A.
7) Unite the two ends with a
coupling (CGIU).
8) Adjust the chain’s tension with the transmission’s screw
and then tighten the nuts.
9) Secure the chain to the pivot of the fi rst wing with the
chain hitch bracket and screws UNI 5931 M8x30.
All the data and information contained herein is considered subject to change at any time and at our discretion
14
ENGLISH
#ONDENS
%
#!-%
2
56 7%
76 5
%
-
5.6 Wiring gearmotors with an encoder system to the command board
For the wiring, use appropriate sheaths and cable clamps to ensure the right degree of protection.
To regulate the encoder, make reference to the technical manual of the command board.
CONTROL PANEL
ZCX10 / ZCX10C
Shielded cable 2402C 22AWG
GEARMOTOR
C-BXE
#!-%
2
-. %
-
.
-
%
%
#!-%
2
56 7%
765
  #/-
-
%
4
4
CONTROL PANEL
ZL80 / ZL80C
GEARMOTOR
C-BXE24
CONTROL PANEL
ZT5 / ZT5C
GEARMOTOR
C-BXET
Shielded cable 2402C 22AWG
Shielded cable 2402C 22AWG
Additional terminal not included
Note: connect the wires of the motor protection fuse in
a series with the wire connected to the “COM” terminal.
15
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
5.7 Wiring gearmotors with mechanical end-stops to the command board
For the wiring, use appropriate sheaths and cable clamps to ensure the right degree of protection.
CONTROL PANEL
ZC3 / ZC3C
GEARMOTOR
C-BX
CONTROL PANEL
ZT6 / ZT6C
GEARMOTOR
C-BXT
&# &! &
#!-%
2
56 7%
76
5
&&#
&!
-
&# &! &
#!-%
2
56 7%
76
5
  #/-
-
&# &! &
4
4
CLOSE PUSHBUTTON
OPEN PUSHBUTTON
POWER SUPPLY
Condenser
Condenser
5.8 Direct connection by interlocking buttons only for C-BX gearmotor
#!-%
2
76
5
&&#
&!
-
Additional terminal not included
Note: connect the wires of the motor protection fuse in
a series with the wire connected to the “COM” terminal.
All the data and information contained herein is considered subject to change at any time and at our discretion
16
ENGLISH
5.9 Adjusting mechanical end-stops
Make sure the door is in a closed position
and the two crown wheels of the motor
units are both positioned to the left.
N.B.: the gearmotor is already adjusted
in a closed position, namely, the closing
end-stop micro-switch is activated.
Execute a complete opening run manually
or by using the button on the command
board; the two crowns will move to the
right.
Using a screwdriver, raise the end-stop
spring from the crown wheels; manually
move the white crown until it reaches the
opening microswitch and then lower the
spring onto the crowns.
Warning! After making the adjustments
on sectional doors in a closed position,
there may be a gap between the lower
edge of the door and the ground
surface. To eliminate this gap, move the
micrometric lever one step up or down to
lower or raise the door by one centimetre.
Make a complete closing run and ensure
that the release lever is free from the
safety lever.
NB: the safety lever releases the
emergency release (CMS or C002) only
when the door is closed.
Safety lever
Release lever
White opening crown
Red closing crown
Microswitch of end-stop in closing
Microswitch of end-stop in opening
End-stop spring
Micrometric lever
17
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
5.10 Adjusting end-stops with encoder
Before beginning to make adjustments
on the end-stop, execute the run calibra-
tion procedure described in the technical
manual of the command board.
After calibrating, the door must be in a
closed position and the crown wheel on
the motor unit must be positioned to the
left.
Raise the end-stop spring unhooking it
from the support bracket and lower it
onto the crown wheel.
Important! For gearmotors installed on
sliding and folding doors, never unhook
the end-stop spring from the support
bracket.
Ensure that the release lever is free from
the safety lever.
NB: the safety lever releases the
emergency release (CMS or C002) only
with the door closed.
Important! For gearmotors installed on
sliding and folding doors, remove the
security lever and respective spring.
Crown wheel
End-stop spring
Support bracket
Safety lever
Release lever
Safety
lever
All the data and information contained herein is considered subject to change at any time and at our discretion
18
ENGLISH
1) After completing assembly and electrical connections, make a hole with
a Ø 13 mm bit in the cover in the point indicated.
5.11 Assembly cover
2) Anchor the cover with the four screws provided.
3) Insert the release handle into the hole and fasten it with the washer
and the screw.
CAME
#!-%
5.12 Manual actuating device
5.13 Emergency release
Manually-operated winch for sectional doors (optional).
A chain-operated device for opening and closing the sectional door, it can be used both when
the automation is either horizontal or vertical.
Devices for releasing the ratiomotor by personalised wrench (CMS)
or with lever complete with suspended-cord transmission (C002).
C002
CMS
#!-%
CA
ME
C001
#!-%
#!-%
2
19
All the data and information contained herein is considered subject to change at any time and at our discretion
ENGLISH
This unit requires no specifi c maintenance. Only as a precautionary measure and in the case of intensive use is it rec-
ommended that you periodically check (6 months) the electric cable connected to the motor, the chain tension, and the bolts and
screws; you can also grease the sliding points between the fi xed and mobile parts.
All checks must be recorded (in a dedicated record-book).
6 Maintenance
In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in
compliance with the UNI EN ISO 14001 standard to ensure environmental protection.
Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development
of its operational and market strategies—simply by observing brief recommendations as regards disposal:
DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste
products and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.
PLEASE DISPOSE OF PROPERLY!
PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron,
electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c re-
cyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries,
etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for
proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.
PLEASE DISPOSE OF PROPERLY!
7 Demolition and disposal
MANUFACTURER’S DECLARATION
As per Enclosure II B of Machinery Directive 98/37/CE
Enclosed with the technical documentation (the original copy of the Declaration is available on request)
Date of the present declaration 07/12/2001
The representatives of
CAME Cancelli Automatici S.p.A.
via Martiri della Libertà, 15
31030Dosson di Casier - Treviso - ITALYtel
(+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: [email protected]
Hereby declare, under their own respons ibility, that the product/s called ...
… comply with the Italian National Legal Provisions that transpose the
following Community Directives (where specifi cally applicable):
M
ACHINERY DIRECTIVE 98/37/CE
L
OW VOLTAGE DIRECTIVE 73/23/EEC - 93/68/EEC
L
ECTROMAGNETIC COMPATIBILITY DIRECTIVE 89/336/EEC - 92/31/EEC
R&TTE D
IRECTIVE 1999/5/CE
Also, they furthermore represent and warrant that the product/s that are the subject of the present
Declaration are manufactured in the respect of the following main harmonized provisions:
EN 292
PART 1 AND 2 MACHINERY SAFETY.
EN 12453 INDUSTRIAL, COMMERCIAL AND OTHER CLOSING MECHANISMS.
EN 12445 I
NDUSTRIAL, COMMERCIAL AND OTHER CLOSING MECHANISMS.
EN 12978 S
AFETY DEVICES FOR POWER OPERATED DOORS AND GATES ....
EN 60335 - 1 SAFETY IN APPARATUSES FOR HOME USE.
EN 60204 - 1 MACHINERY SAFETY.
EN 61000 - 6 - 2 ELECTROMAGNETIC COMPATIBILITY.
EN 61000 - 4 - 4 E
LECTROMAGNETIC COMPATIBILITY.
EN 61000 - 4 - 5 E
LECTROMAGNETIC COMPATIBILITY.
IMPORTANT CAUTION!
It is forbidden to market/use product/s that are the subject of this declaration before completing and/or
incorporating them in total compliance with the provisions of Machinery Directive 98/37/CE
Signatures of the Representatives
TECHNICAL MANAGER
Mr. Gianni Michielan
MANAGING DIRECTOR
Mr. Paolo Menuzzo
CBX - CBXE - CBXE24 - CBXT - CBXET
CMS - CGP - CCT - CGIU - C001 - C002 - C003
C004 - C005 - C006 - C007 - C008
8 Manufacturers warranty
Cod. 119CT54 ver. 1.1 - 10/05 © CAME CANCELLI AUTOMATICI
CAME UNITED KINGDOM LTD
UNIT 3, ORCHARD BUSINESS PARK TOWN
STREET, SANDIACRE
NOTTINGHAM - NG10 5BP - U.K.
Tel 0044 115 9210430
Fax 0044 115 9210431
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

CAME C-BXE24 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI