Thorn Cavell / CAVELL 6600 840 HFIX L950 , Cavell / CAVELL 6600 830 HFIX L950 Installation guide

  • Hello! I've reviewed the provided document, which details the installation and wiring instructions for the Bedhead Light 2xDALI Control Circuits. The document includes crucial information such as mounting the wall plate, wiring the terminal blocks, utilizing safety cords, and diagrams for proper installation. I'm ready to answer any questions you might have about the installation process or the device itself.
  • What type of terminal block is used for mains and DALI connections?
    Where should the safety cord dog clips be attached?
    What should the wiring of the plug and socket correspond to?
AND GEAR TRAY ASSEMBLY
WALL MOUNTED FIXING PLATE
MAIN BODY ASSEMBLY
SCALE: NTS
LIGHTING - 4K - IP40
FOR UP & DOWNWARD
2xDALI CONTROL CIRCUITS
GLOSS WHITE
1/1.2 & 1.5
NO.
2.0 UNLESS OTHERWISE STATED
DETAILS DRG
THORN LIGHTING
DATE:
INSTALLATION & WIRING
M/STEEL-0.4 MIRO5
TITLE/PROJECT
CLIENT/CUSTOMER:
DRAWING PROTECTED BY COPYRIGHT
C
DATE:
DRWG NO.
DRAWN:
SC
21/06/21
15-8712-02INST SHT1
MATERIAL: FINISH:
REVISIONS:
BEDHEAD FTG
GENERAL TOLERANCES: LINEAR= 1.0 ANGULAR=
A1
ON THE WALL FIXED BRKT
TO MAIN BODY ASSEMBLY.
5 WAY TERMINAL BLOCK FIXED
MUST BE WIRED AS LABELLED, TO SUIT SOCKET TERMINAL BLOCK
DURING ASSEMBLY
DOWNLIGHT TO DOWNLIGHT, EARTH TO EARTH
MOUNTED ON THE WALL BRKT ASSEMBLY. UPLIGHT TO UPLIGHT,
DOG CLIP SAFETY CORD
SECURED TO MAIN BODY ASSY,
TO BE FITTED TO WALL BRKT LABELLING REQUIRED
WIRED TO L.E.D's BOARDS AS
LABELLED 5 WAY 'PLUG' TERMINAL BLOCK.
WIRED TO L.E.D BOARDS TERMNIAL BLOCK USING 350mm FLYING LEADS.
TAB FIXINGS ON MAIN BODY ASSY
TO FIT INTO CORRESPONDING SLOTS
SIDE VIEW
LOOKING AT THE BACK
OF THE MAIN BODY ASSEMBLY
O
P
G
G
SECTIONED END VIEW
SECTION G-G
SCALE 1 : 3
PLAN VIEW
LOOKING AT THE UNDERSIDE
OF THE MAIN BODY ASSEMBLY
DETAIL P
SCALE 1 : 1
LABELING REQUIRED
DETAIL O
SCALE 1 : 1
FLYING LEADS
350mm
USING
FLYING LEADS
ON WALL FIXED BRKT
TO FIT INTO CORRESPONDING SLOTS
TAB FIXINGS ON MAIN BODY ASSY
MOUNTED TO MAIN BODY ASSEMBLY
WIRED TO 'PLUG' 5 WAY TERMINAL
BLOCK USING 350mm
WIRED TO FIXED 5 WAY TERMINAL
HEAVY DUTY DOG CLIP SAFETY CORD,
SECURED TO MAIN BODY ASSY,
TO BE FITTED TO THE WALL BRKT
DURTING ASSEMBLY
Q
TAB FIXINGS
DETAIL Q
SCALE 1 : 1
MOUNTED TO THE WALL
PLAN VIEW SHOWING
TOP OF WALL BRKT WHEN
SLOTS TO TOP
=923=
=800= DIMPLE FIXING CTS
FRONT VIEW SHOWING
WIRING MUST CORRESPOND WITH THE SOCKET
TO THE WALL
WHEN MOUNTED
SCREW FIXED TO WALL
RUNNING AT 250mA
DOWNLIGHT DRIVER POSITION
HEAVY DUTY DOG CLIP SAFETY
CORD, SECURED TO MAIN
BODY ASSY, FIXING POSITION
TERMINAL BLOCK WIRING I.E UPLIGHT TO UPLIGHT ETC
5 WAY SOCKET TERMINAL BLOCK
OR ALTERNATIVELY USING
USING DIMPLED FIXINGS
HEAVY DUTY DOG CLIP SAFETY
CORD, SECURED TO MAIN
MOUNTED TO GEAR TRAY / WALL
BRKT ASSEMBLY - TO BE WIRED AS
TERMINAL BLOCK AND SECURE CABLE USING
THE CABLE RESTRAINT LABELLED INCLUDING EARTH LINK
TO MAINS IN TERMINAL BLOCK.
5 WAY MAINS AND DALI TERMINAL BLOCK.
WIRE MAINS IN AND DALI CABLES TO THIS
MAINS IN 20mm
GROMMETED HOLE
BODY ASSY, FIXING POSITION
THE BESA PIERCINGS
5 WAY 'PLUG' TERMINAL BLOCK
IS PART OF THE MAIN BODY ASSEMBLY
AND COMES WITH FLYING CABLES FOR
UPLIGHT / DOWNLIGHT & EARTH CONNECTIONS.
UPLIGHT DRIVER POSITION
RUNNING AT 350mA
D
A
=600=
6
TAB SLOTS TO BE AT THE TOP OF
THE FITTING WHEN MOUNTED TO
THE WALL FIXED BRKT ASSY
THE WALL
MAIN BODY ASSEMBLY FIXING
M4 CLENCH NUT FIXINGS
ARE AT THE BOTTOM OF
SLOTS TO TOP
F
DETAIL D
SCALE 1 : 1
5 WAY MAINS AND DALI TERMINAL
BLOCK. WIRE MAINS IN AND DALI
CABLES TO THIS TERMINAL BLOCK
AND SECURE CABLE USING THE
CABLE RESTRAINT
END VIEW
8x2mm GASKET POSITION
ADHERED TO WALL FIXING
BRKT ASSEMBLY
M4 CLENCH NUT FIXINGS.
AT THESE POINTS WHEN GULLY INSTALLED
MAIN BODY IS SCREW FIX SECURED
AT THESE POINTS WHEN GULLY INSTALLED
ADHERED TO WALL FIXING
BRKT ASSEMBLY
8x2mm GASKET POSITION
M4 CLENCH NUT FIXINGS.
MAIN BODY IS SCREW FIX SECURED
PLAN VIEW SHOWING
BOTTOM OF WALL BRKT WHEN
MOUNTED TO THE WALL
5 WAY SOCKET TERMINAL BLOCK
DETAIL A
SCALE 1 : 1
MOUNTED TO GEAR TRAY / WALL
BLOCK WIRING I.E. UPLIGHT TO UPLIGHT ETC
LABELLED
CORRESPOND WITH THE SOCKET TERMINAL
BRKT ASSEMBLY - TO BE WIRED AS
5 WAY PLUGGED TERMINAL BLOCK
IS PART OF THE M,AIN BODY ASSEMBLY
AND COMES WITH FLYING LEADS FOR
UPLIGHT / DOWNLIGHT & EARTH
CONNECTIONS. WIRING MUST
LABELLING REQUIRED
DETAIL F
SCALE 1 : 1
SLOTS TO TOP
ADDITIONAL INSTALLATION STEP ADDED
SCALE: NTS
R1 10/09/21
2.0 UNLESS OTHERWISE STATED
LIGHTING - 4K - IP40
2xDALI CONTROL CIRCUITS
1/1.2 & 1.5
FOR UP & DOWNWARD
DATE:
DETAILS DRG
THORN LIGHTING
GLOSS WHITE
INSTALLATION & WIRING
M/STEEL-0.4 MIRO5
TITLE/PROJECT
CLIENT/CUSTOMER:
DRAWING PROTECTED BY COPYRIGHT
C
DATE:
DRWG NO.
DRAWN:
SC
21/06/21
15-8712-02INST SHT2 -R1
MATERIAL: FINISH:
REVISIONS:NO.
BEDHEAD FTG
GENERAL TOLERANCES: LINEAR= 1.0 ANGULAR=
A1
I
I
WALL BRACKET MAIN BODY
FIXING SLOTS
SECTION J-J
SCALE 1 : 4
K
FIT BOTH SAFETY CORD DOG CLIPS TO WALL
MOUNTED ON THE WALL FIXED BRKT.
FIXED BRKT IN POSITIONS SHOWN ABOVE
THEN CONNECT THE 5 WAY PLUG, C/W
FLYING LEADS TO THE 5 WAY SOCKET
ONCE MAIN BODY IS ALIGNED WITH THE WALL
FIXED BRKT ASSEMBLY, FIT AND TIGHTEN M4
SCREWS C/W WASHERS THEN FINISH BY FITTING
THE SCREW DUST CAPS.
FITTING IS NOW FULLY INSTALLED.
PLATE.
MOUNTED ON THE WALL FIXING
CABLES TO THE TERMINAL BLOCK
WIRE THE MAINS IN AND DALI
THE TOP.
SURE THE SLOT FIXINGS ARE AT
ASSEMBLY TO THE WALL MAKING
FIXING PLATE AND GEAR TRAY
SCREW FIX WALL MOUNT
STEP 2;
STEP 3;
ONCE WALL FIXING BRKT IS FIXED AND
STEP 4;
STEP 6;
MEETS THE WALL,
MAIN BODY DOWNWARD UNTIL IT
WITH THE FIXING SLOTS, ROTATE THE
ONCE FIXING TAGS ARE ALIGNED
STEP 5;
UP THE MAIN BODY ASSEMBLY.
WIRED INTO MAINS / DALI THEN OFFER
THE WALL FIXED BRKT SLOTS
UNTIL THE MAIN BODY TAGS SLIP INTO
AND SLIDE OVER WALL FIXED BRKT
ANGLE THE MAIN BODY AS SHOWN &
DOG CLIP SAFETY CORDS ARE FITTED,
ONCE TERMNIAL BLOCKS ARE MATED &
STEP 1;
REMOVE SCREW CAP COVERS AND
REMOVE BOTTOM FIXING SCREWS.
HINGE THE WALL MOUNT FIXING PLATE OUTWARD,
FROM THE SCREW SIDE OF MAIN BODY,
THEN SLIDE THE WALL PLATE AWAY FROM THE TAG
FIXINGS TO REMOVE THE WALL PLATE.
DISCONNECT THE PLUG AND SOCKET TERMINAL
BLOCK CONNECTIONS TO RELEASE WALL PLATE
FROM MAIN BODY FULLY.
J
J
FIT SAFETY CORD DOG CLIPS TO
WALL MOUNTED BRKT ASSY
CONNECT 5 WAY PLUG TERMNIAL
BLOCK TO CORRESPONDING
5 WAY SOCKET MOUNTED ON
WALL FIXED BRKT ASSY
DETAIL K
SCALE 1 : 1.1
SHOWING MAIN BODY
TAGS FITTING INTO THE
WALL FIXED BRKT SLOTS
SECTION L-L
END VIEW
SCALE 1 : 4
M4 FIXING SCREWS AND
CAPS READY TO BE FITTED
SIDE VIEW
L
L
PLAN VIEW
LOOKING FROM
BELOW
THE FITTING
THE BESA PIERCINGS
USING DIMPLED FIXINGS
OR ALTERNATIVELY USING
BODY ASSY, FIXING POSITION
CORD, SECURED TO MAIN
HEAVY DUTY DOG CLIP SAFETY
BODY ASSY, FIXING POSITION
CORD, SECURED TO MAIN
HEAVY DUTY DOG CLIP SAFETY
5 WAY SOCKET TERMINAL BLOCK
SCREW FIXED TO WALL
TO MAINS IN TERMINAL BLOCK.
LABELLED INCLUDING EARTH LINK
BRKT ASSEMBLY - TO BE WIRED AS
MOUNTED TO GEAR TRAY / WALL
THE CABLE RESTRAINT
TERMINAL BLOCK AND SECURE CABLE USING
GROMMETED HOLE
MAINS IN 20mm
WIRE MAINS IN AND DALI CABLES TO THIS
5 WAY MAINS AND DALI TERMINAL BLOCK.
TERMINAL BLOCK WIRING I.E UPLIGHT TO UPLIGHT ETC
5 WAY 'PLUG' TERMINAL BLOCK
IS PART OF THE MAIN BODY ASSEMBLY
AND COMES WITH FLYING CABLES FOR
UPLIGHT / DOWNLIGHT & EARTH CONNECTIONS.
WIRING MUST CORRESPOND WITH THE SOCKET
FRONT VIEW SHOWING
WHEN MOUNTED
TO THE WALL
H
N
=600=
6
THE FITTING WHEN MOUNTED TO
THE WALL
TAB SLOTS TO BE AT THE TOP OF
THE WALL FIXED BRKT ASSY
MAIN BODY ASSEMBLY FIXING
M4 CLENCH NUT FIXINGS
ARE AT THE BOTTOM OF
SLOTS TO TOP
D
END VIEW
SCALE 2 : 3
DETAIL H
5 WAY MAINS AND DALI TERMINAL
BLOCK. WIRE MAINS IN AND DALI
CABLES TO THIS TERMINAL BLOCK
AND SECURE CABLE USING THE
CABLE RESTRAINT
PLAN VIEW SHOWING
TOP OF WALL BRKT WHEN
MOUNTED TO THE WALL
=923=
=800= DIMPLE FIXING CTS
DETAIL N
SCALE 2 : 3
DETAIL D
SCALE 2 : 3
SLOTS TO TOP
SIDE VIEW
M
M
PLAN VIEW
LOOKING FROM
BELOW
THE FITTING
SCALE 1 : 3
SECTIONED
END VIEWS
FIXING SCREWS
SECTION M-M
END VIEW
SCALE 1 : 4
PLUG AND SOCKET TERMINAL
BLOCK AND FLYING LEADS
WALL MOUNT
FIXING PLATE
/