Marantec Comfort 260 Owner's manual

Category
Garage Door Opener
Type
Owner's manual

This manual is also suitable for

Operating instructions
Last updated: 04.2014
Operator systems for garage doors
Comfort 260 accu
GB
2 Operating instructions, Comfort 260 accu (#114332 – GB)
Table of Contents
1. General safety instructions .....................3
1.1 Intended use ................................3
1.2 Target group ................................3
1.3 Warranty ...................................3
2. Scope of supply ..............................4
3. Door system .................................5
4. Installation ..................................6
4.1 Preparing for installation .......................6
4.2 Installing the drive ............................6
4.3 Installing the rechargeable battery unit ...........10
4.4 Charge controller function ....................10
4.5 Connection of control elements .................11
4.6 Completing the installation ....................12
4.7 Rechargeable battery unit .....................12
5. Setting in operation ..........................14
5.1 Overview of the controls ......................14
5.2 Status display ..............................15
5.3 Factory settings .............................15
5.4 Express programming ........................15
5.5 Function test ...............................16
5.6 Special programming .........................17
6. Operation ..................................22
6.1 Hand transmitter ............................22
6.2 Release mechanism ..........................24
7. Maintenance ...............................24
8. Disassembly ................................24
9. Disposal ...................................25
10. Rectifying faults .............................25
11. Appendix ..................................27
11.1 Technical Data ..............................27
11.2 Declaration of Incorporation ....................28
Regarding this document
Original instruction manual.
Part of the product.
Read these instructions carefully before use and keep them in a
safe place for future reference.
Protected by copyright.
No part of this manual may be reproduced without our prior
approval.
Subject to alterations in the interest of technical progress.
All dimensions are given in millimetres.
The drawings are not true to scale.
Meaning of symbols
DANGER!
Safety notice indicating a danger that will directly result in death or
severe injury.
WARNING!
Safety notice indicating a danger that could result in death or severe
injury.
CAUTION!
Safety notice indicating a danger that could result in slight or
moderate injuries.
NOTICE
Safety notice indicating a danger that could result in damage to
property or in irreparable damage to the product.
CHECK
Reference to a check that needs to be carried out.
REFERENCE
Reference to separate documents that must be observed.
• Instruction requiring action
List, itemisation
Reference to other sections of this document
) Factory settings
DANGER!
IMPORTANT SAFETY INSTRUCTIONS:
ATTENTION! IT IS VITALLY IMPORTANT FOR THE SAFETY OF
PERSONS THAT YOU FOLLOW ALL THE INSTRUCTIONS.
KEEP THESE INSTRUCTIONS IN A SAFE PLACE.
IMPORTANT INSTRUCTIONS FOR SAFE INSTALLATION:
ATTENTION! SERIOUS INJURIES CAN BE CAUSED IF THE EQUIP-
MENT IS NOT INSTALLED CORRECTLY – BE SURE TO FOLLOW ALL
THE INSTALLATION INSTRUCTIONS.
Operating instructions, Comfort 260 accu (#114332 – GB) 3
1. General safety instructions
DANGER!
Failure to comply with the documentation could result in
life-threatening danger!
• Be sure to follow all the safety instructions in this document.
1.1 Intended use
The operator system is to be used only for opening and closing
doors.
Never use the door system to help lift persons or objects.
The following applies for the product Comfort 260 accu:
Only approved for use in dry rooms.
The following values must be observed:
maximum tensile force
maximum compressive force
maximum door size
maximum door weight
“11.1 Technical Data”
The product is intended for private use.
The product is suitable only for counterbalanced sectional and up-
and-over doors with a fall arrest system.
1.2 Target group
Installation, connection and setting in operation:
qualied,trainedspecialistpersonnel.
Operation, inspection and servicing:
the operator of the door system.
Requirementstobemetbyqualiedandtrainedspecialiststaff:
Knowledgeofthegeneralandspecicsafetyandaccident-
prevention regulations.
they have knowledge of the relevant electrical regulation,
Training in the use and care of appropriate safety equipment.
Adequateinstructionandsupervisionbyqualiedelectricians.
The ability to recognise hazards that can be caused by electricity.
Knowledge of the application of the following standards
– EN 12635 (“Doors and gates - Installation and use”),
EN 12453 (“Safety in use of power operated doors -
Requirements”),
EN 12445 (“Safety in use of power operated doors -
Test methods”),
Requirements to be met by the operator of the door system:
Knowledge and safekeeping of the instruction manual.
Knowledge of general safety and accident-prevention regulations.
1.3 Warranty
The product is manufactured in accordance with the guidelines
and standards listed in the manufacturer’s declaration and in the
declaration of conformity. The product left the factory in perfect order
with regard to safety.
In the following cases, the manufacturer will accept no liability for
damage. The warranty on the product and accessory components
becomes void in the event of:
Failure to observe these operating instructions.
Incorrect handling and use of the product for anything other than
its intended purpose.
Workbeingcarriedoutbyunqualiedpersonnel.
Changesormodicationstotheproduct.
The use of replacement parts that have not been approved or were
not manufactured by the manufacturer.
The warranty does not cover batteries, rechargeable batteries, fuses or
bulbs.
Further safety instructions are given in the relevant sections
of the document.
“4. Installation”
“5. Setting in operation”
“6. Operation”
“7. Maintenance”
“8. Disassembly”
4 Operating instructions, Comfort 260 accu (#114332 – GB)
2. Scope of supply
Various versions of the product are available. Please refer to the table
and check the items included in the delivery to determine which ver-
sion you have received.
Theremaybesomecountry-specicdifferences.
Item Door operator
1
1x
2
1x
3
2x
4
1x
Item Fittings A B
5
2x 2x
6
1x 1x
7
2x 2x
8
1x 1x
9
2x 2x
10
1x
11
1x
12
1x
Item Fastening elements - 01 A B
13
4x 4x
14
2x 2x
15
1x 1x
16
1x 1x
17
1x 1x
18
1x 1x
19
2x 2x
20
1x 1x
21
1x
22
1x
23
4x
Item Fastening elements - 02
24
6x
25
6x
26
6x
Item Warning signs
27
1x
28
1x
Operating instructions, Comfort 260 accu (#114332 – GB) 5
Item Hand transmitter Multi-Bit bi·linked
29
1x 1x
30
1x
31
1x
32
1x 1x
33
1x 1x
34
1x
35
1x
Item Rechargeable battery unit
36
1x
37
1x
38
1x
39
2x
40
2x
3. Door system
Overview
3 / 1
3
1
1
2
4
5
This is just an example of a door system. The details can vary according
to the type of door and the associated equipment. The system shown
comprises the following components:
1 Photocell
2 Key switch
3 Free-standing post (for code keypad, transponder etc.)
4 Solar module (optional)
5 Rechargeable battery unit
REFERENCE
For further information regarding accessory items, please see the
manufacturer’s website.
For the installation and cabling of the door sensors, control elements
and safety equipment, the relevant installation instructions must be
observed.
6 Operating instructions, Comfort 260 accu (#114332 – GB)
4. Installation
DANGER!
Life-threatening danger due to electric shock!
• It is vital that you disconnect the operator system from the
power supply before commencing cabling work. Take measures
to ensure that the power supply remains disconnected for the
duration of the work.
• Observe the local safety regulations.
• It is imperative that you lay power cables separately from control
cables.
The control voltage is 24 V DC.
NOTICE
Material damage resulting from incorrect installation of the
operator!
To avoid installation errors and damage to the door or operator
system, the following installation instructions must be observed at all
costs.
• Ensure that the door is in good mechanical condition:
The door remains stationary in every position.
The door can be moved easily.
The door opens and closes properly.
• Install all impulse transmitters and control equipment (such as
radio code buttons e. g.) within sight of the door and at a safe
distance from the door’s moving parts. The installation height
mustbeatleast1.5metresfromtheground.
• Onlyusexingmaterialsthataresuitableforthefoundation
material in question.
4.1 Preparing for installation
Before commencing installation, the following works must be carried
out without fail.
Supply package
• Check which version you have received and that all the parts are
present.
• Ensure that a suitable operator boom is available.
• Check that all the necessary accessory parts for your installation
situation are present.
Door system
• Remove any components (such as ropes, chains, brackets, etc.) from
the door that are no longer needed.
• All equipment that will no longer be required after the door
operator system has been installed must be taken out of service.
For garages without a second entrance:
• Fit the garage door with an emergency release mechanism so that
you can gain entry to the garage if there is a malfunction.
If a release set is used:
• Check that the door catches function properly. On no account
should the door catches be taken out of service.
If no release set is used:
• Remove the door catches or take them out of service.
REFERENCE
When using and installing accessory equipment, observe the
corresponding documentation.
4.2 Installing the drive
4.2 / 1
4.2 / 2
A
ø 5 – 5,5
4x
Operating instructions, Comfort 260 accu (#114332 – GB) 7
NOTICE
Possibility of damaging the motor unit!
Do not use force, as this could damage the teeth of the gears!
• Carefullyxtheoperatorboomtothemotorunit.
4.2 / 3
A
1x
4x
B
1x
4x
4.2 / 4
1x
2x
B
ø 5 – 5,5
4x
8 Operating instructions, Comfort 260 accu (#114332 – GB)
WARNING!
Possibility of serious injury due to falling components!
• Secure the operator system to prevent if from falling before it is
properlyxedinplace.
4.2 / 5
NOTICE
Possibility of damaging the door leaf!
At its highest point during opening, the top edge of the door leaf
must be 10 - 50 mm below the bottom edge of the horizontal
operator boom.
• Fix the lintel joining plate for the operator boom. It must be
positioned centrally above the door leaf.
4.2 / 6
10 - 50
ø 10
4.2 / 7
2x
2x
2x
4.2 / 8
1.
2.
3.
1x
1x
4.2 / 9
1.
2.
4.2 / 10
1.
2.
1x
2x
4.2 / 11
Operating instructions, Comfort 260 accu (#114332 – GB) 9
4.2 / 12
a
b
5-10
A
1x
1x
a = 90°
b = 9 Nm
B
4x
5-10
1.
2.
2.
4.2 / 13
4.2 / 14
2/3
1/3
1.
2.
3.
4.2 / 15
ø 10
4.2 / 16
2x
2x
2x
10 Operating instructions, Comfort 260 accu (#114332 – GB)
4.3 Installing the rechargeable battery unit
NOTICE
Risk of property damage due to improper installation of the
rechargeable battery unit!
Moisture and vibrations may result in the destruction of the entire
electronic system.
• Choose a dry installation position.
• During installation and operation of the battery unit, ensure that
the connector never points downwards.
• Secure the rechargeable battery unit to prevent it from falling.
4.3 / 1
ø 6
4.3 / 2
4.3 / 3
4.3 / 4
4.4 Charge controller function
4.4 / 1
A
B
Status LED A (green) LED B (red)
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
< 1/4
Operating instructions, Comfort 260 accu (#114332 – GB) 11
4.5.1 Overview of the control element connections
4.5.1 / 1
XB03 XB72
XB03 Connection for
external control elements
Photocell
“Level 5, Menu 1 - Programmable impulse
input (terminal 1/2)”
“4.5.3 Terminal block XB03”
XB72
Connection for modular antenna
“4.5.2 Terminal block XB72”
4.5.2 Terminal block XB72
4.5.2 / 1
Key
< 1/4
LED on
< 1/4
LEDashing
< 1/4
LEDashingquickly
< 1/4
LED off
4.5 Connection of control elements
DANGER!
Life-threatening danger due to electric shock!
• It is vital that you disconnect the operator system from the
power supply before commencing cabling work. Take measures
to ensure that the power supply remains disconnected for the
duration of the work.
NOTICE
Danger of material damage resulting from incorrect
installation of the operator!
If an external voltage is connected to terminal block XB03, the entire
electronic system will be irreparably damaged.
• Connect only potential-free contacts to terminals 1, 2 and 4
(XB03).
12 Operating instructions, Comfort 260 accu (#114332 – GB)
4.5.3 Terminal block XB03
4.5.3 / 1
4.5.3 / 2
- XB03
7170
TX
RX
-W1
1
2
-W2
1
2
12
-W1
-W2
- AP27
1
23
-Sb1
4
-Sb4
M14E001
1 24 V DC + / 50 mA max.
2 Impulse
3 GROUND -
4 Hold circuit, active after a reset
70 GROUND
71 Photocell
AP27 Photocell
RX Photocell receiver
TX Photocell transmitter
Sb1 Impulse button
Sb4 Normally closed contact for hold circuit
4.5.3 / 3
4.6 Completing the installation
• Takethewarningsignsregardingtrappinghazardsandafxthem
permanently at noticeable locations.
• After installation is complete, ensure that no door parts extend
onto the public footpath or the street.
4.7 Rechargeable battery unit
4.7.1 General information about the operation of the
rechargeable battery unit
WARNING!
Risk of injury due to improper handling of the plug-in
charger and the rechargeable battery unit!
There is an explosion hazard due to the formation of explosive gases
during the charging of lead batteries.
Ifmoistureispresent,thereisareandshort-circuithazarddueto
electric shocks. In order to exclude hazards:
• Charge the battery unit exclusively in well-ventilated rooms.
• Never short-circuit the battery unit.
• Avoidreandopenlight.
• The plug-in charger must only be operated in dry rooms.
• Protect the unit against moisture.
• Protect the unit against oils and sharp edges.
• Check the unit regularly for damage.
NOTICE
Malfunction due to improper battery operation.
If the battery unit is operated at low battery voltage despite a warning
signal from the operator system, it will disconnect from the drive
system to prevent discharge to low level. To ensure that it functions
correctly, the rechargeable battery unit must be charged as follows:
In the case of occasional use, every 2 months at the latest,
In the case of non-use, every 6 months at the latest.
Duration of use
Under optimum conditions, a battery unit has a useful life of approx.
30dayswith4(openingandclosing)movementcyclesperday.
Voltage display
A battery unit switch-on test is conducted when the battery unit
is connected to the drive system. If the battery unit is not charged
sufciently,theoperatorlightingwillash5timesafterreachingthe
OPEN end position. The storage battery unit then needs to be charged
immediately.
“4.4 Charge controller function”
Standby
It is possible to activate the operator from standby mode as follows:
by pressing the +, – or P key,
by pressing a button on the hand transmitter,
by pressing an internal button that is connected to terminals 1
and2.
Operating instructions, Comfort 260 accu (#114332 – GB) 13
Displays
Green LED on:
The unit is in charging mode.
GreenLEDashing:
The charging process is complete.
4.7.2 / 4
4.7.2 / 5
4.7.2 / 6
Only if a solar module is used.
4.7.2 Charging procedure
NOTICE
Risk of material damage due to improper handling!
Only if solar module is connected:
To ensure that it functions correctly, it is essential that action is taken
in the following order only:
The operator cable must only be removed if the solar module has
rstbeendisconnectedfromtherechargeablebatteryunit.
“4.7.2 / 1”
The solar module must only be connected to the rechargeable
battery unit if the operator cable has been connected to the
batteryunitrst.
“4.7.2 / 6”
4.7.2 / 1
Only if a solar module is used.
4.7.2 / 2
4.7.2 / 3
14 Operating instructions, Comfort 260 accu (#114332 – GB)
5. Setting in operation
Before initial operation and at regular intervals of no more than one
year, power-operated windows, doors and gates must be inspected by a
qualiedperson(wherebywritteninspectionrecordsmustbekept).
After setting the system in operation, the operator of the door system,
or the operator’s representatives, must be instructed in the operation of
the system.
WARNING!
Danger of injury due to uncontrolled movement of the
door!
• Ensure that children can not play with the door controls or the
hand transmitter.
• Before setting the door in motion, make sure that no persons or
objects are within the danger zone of the door.
• Before going through the door opening, make sure that the door
is in the OPEN position.
• Check all the existing emergency command devices.
• Pay attention to potential crushing and shearing zones in the
door system.
• Never touch a running door, the guide rail or any moving parts.
• The regulations of DIN EN 13241-1 (“Doors and gates - Product
Standard”) must be observed.
5.1 Overview of the controls
Control elements
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
LED display
Drive the door in the OPEN direction,
increase the value
Drive the door in the CLOSE direction,
decrease the value
P
Startprogramming,conrmandsavevalues
Legend
Thedisplayashes
Display lights up
Display Function / Element
Ready for operation
Door position: CLOSED
Door position: OPEN
Fault message / Maintenance indicator in CLOSED
door position
Photocell or closing edge safety device
Remote control
External button
3
Status display
(Example showing display 3 – rechargeable
battery connected)
“5.2 Status display”
1
2
3
4
5
6
7
8
9
0
Level indicator (example: Level 2)
1
2
3
4
5
6
7
8
9
0
Menu and parameter indicator
(example:Menu3,Parameter8)
Minute indicator
1
2
3
4
5
6
7
8
9
0
Times exceeding one minute are shown in
minutes and seconds.
Example: 1.2 = 1 minute + 20 seconds =
80seconds
Operating instructions, Comfort 260 accu (#114332 – GB) 15
5.2 Status display
Display Function / Element
3
Rechargeable battery connected
4
Warning time indicator (only for programmed
automatic closing)
5.3 Factory settings
Using the reset procedure, the operator parameters can be restored to
their original factory settings.
“Level 1, Menu 8 – RESET”
5.4 Express programming
To set the operator system properly in service and after every reset, the
express programming procedure must be carried out.
Requirements:
The door must be in the CLOSED position.
The carriage must be coupled up.
“6.2 Release mechanism”
When in programming mode, the controls will revert automatically to
operating mode if a period of 120 seconds passes without any buttons
being pressed.
A corresponding fault number will be displayed.
“10. Rectifying faults”
• Carry out the express programming procedure.
CHECK
A function test must be carried out after express programming.
“5.5 Function test”
Express programming
1. Programming the “OPEN” door position
The control system is in
operating mode.
P
P > 3 sec. < 10 sec.:
Start express programming.
Drive the door to the OPEN
position.
P
Save the OPEN position.
2. Programming the “CLOSED” door position
Drive the door to the CLOSED
position.
P
Save the CLOSED position.
3. Programming the remote control Multi-Bit
Press the hand transmitter
button.
Release the hand transmitter
button.
P
Save the remote control
setting.
End express programming.
The control system is in
operating mode.
16 Operating instructions, Comfort 260 accu (#114332 – GB)
Express programming
3. Programming the remote control bi·linked
Open the rear panel of the
hand transmitter.
Press the programming button
on the hand transmitter.
Press the hand transmitter
button.
Release the hand transmitter
button.
P
Save the remote control
setting.
End express programming.
The control system is in
operating mode.
Close the rear panel of the
hand transmitter.
5.5 Function test
5.5.1 Programming run for setting the driving power
Duringthersttworunsafterthedoorpositionshavebeenpro-
grammed, the operator system determines the maximum required
driving power.
• Drive the operator system (with the door coupled up) from the
CLOSED door position to the OPEN position and back again,
without interruption.
• Check the driving power.
Check the driving power
1.
The control system is in
operating mode.
2.
The door should open and
move to the saved “OPEN”
door position.
3.
The door should close and
move to the saved “CLOSED”
door position.
4.
The door operator should move
the door in the OPEN or CLOSE
direction.
5.
The operator system should
stop.
6.
The operator system should run
in the opposite direction.
Operating instructions, Comfort 260 accu (#114332 – GB) 17
5.5.2 Checking the automatic cut-out
WARNING!
Danger of injury due to incorrectly programmed values for
the door driving power!
• Check the automatic cut-out function in the OPEN and CLOSE
directions.
Automatic cut-out in the OPEN direction
This checking procedure only applies to operator systems that are
installed to operate doors that have openings in the door leaf (with
openings > 50 mm in diameter):
• During travel, apply a load of 20 kg to the door at the mid point of
the bottom edge of the door:
The door should stop immediately.
Automatic cut-out in the CLOSE direction
This checking procedure applies to all door systems.
• Placeanobject,50mminheight,ontheoor.
• Drive the door towards the obstacle:
The operator system should stop and reverse when it touches the
obstacle.
The settings of the OPEN and CLOSING operator forces remain saved
even if the power supply is interrupted.
The parameters are returned to the factory settings only after a reset.
“Level 1, Menu 8 – RESET”
5.5.3 Checking the photocell
Photocell
• Check all the photocells individually by triggering them.
• Check all the photocells just before the door reaches the CLOSED
position.
Special points regarding door-frame photocells
A door-frame photocell must function above the position at which
it is installed. Below the installation position, the function of the
photocell is suppressed by the control unit.
If several photocells are connected, all the photocells function in
the same way as a door-frame photocell, if present.
5.6 Special programming
WARNING!
Danger of injury due to incorrect settings for the door
driving power!
Important factory settings can be changed when programming the
special functions.
• Check the programmed parameter values.
• Check the programmed door driving power values after changes
have been made to the automatic cut-out setting.
“5.5.2 Checking the automatic cut-out”
• Carry out the necessary measurements to validate the correct
force limitation.
NOTICE
Material damage resulting from incorrect programming of
the door operator.
After a reset, all the parameters are returned to the factory settings.
Safety elements that are operational and are connected to the system
will be recognised anew after a reset.
To ensure that the controls functions properly:
• Reprogram all the required functions.
• Reprogram the remote control.
• Drive the operator system once to the OPEN position and then the
CLOSED position.
If a photocell is connected, it will be automatically detected by the
control system as soon as the power supply is connected.
The photocell can be reprogrammed later.
Photocells that are not required must be disconnected before the
power supply is connected; otherwise they will be recognised by the
controls.
“4.5.3 Terminal block XB03”
CHECK
A function test must be carried out after changes have been made in
programming mode.
“5.5 Function test”
18 Operating instructions, Comfort 260 accu (#114332 – GB)
5.6.1 Programming the special functions
Programming procedure
1.
The control system is in
operating mode.
2.
P
P > 10 sec.:
Start programming the
extended operator functions.
Display the levels.
1
2
3
4
5
6
7
8
9
0
3.
Select the level required
(example: Level 2).
1
2
3
4
5
6
7
8
9
0
4.
P
Conrmthelevelrequired.
Displaytherstmenuandthe
programmed parameter.
1
2
3
4
5
6
7
8
9
0
5.
Select the menu required
(example Menu 3).
1
2
3
4
5
6
7
8
9
0
6.
P
Conrmthemenurequired.
Display the programmed
parameter value.
1
2
3
4
5
6
7
8
9
0
7. Change the parameter value.
1
2
3
4
5
6
7
8
9
0
8.
P
Save the parameter value.
The control system switches to
display the levels.
1
2
3
4
5
6
7
8
9
0
9.
Select the next level required.
Continue programming.
1
2
3
4
5
6
7
8
9
0
or
P
P > 5 sec.:
Finish programming.
All the altered parameters are
saved.
The control system is in
operating mode.
5.6.2 Overview of the special functions
Level Menu
1
Basic functions
3 Intermediate OPEN position
4 Intermediate CLOSE position
8 RESET
2
Operator settings
1 Driving power required to OPEN
2 Driving power required to CLOSE
3 Automatic cut-out in the OPEN direction
4 Automatic cut-out in the CLOSE direction
3
Automatic closing
timer
1 Automatic closing timer
3 Door open duration
4 Warning time
5 Start-up warning
4
Remote
programming
2 Intermediate OPEN position
3 Intermediate CLOSE position
4 OPEN
5 CLOSE
5
Special functions
1 Programmable impulse input
4 Lighting duration
6
Variable
speed
1 OPEN speed
2 Soft run OPEN speed
3 Soft run OPEN position
4 CLOSE speed
5 Smart run CLOSE speed
6 Soft run CLOSE speed
7 Smart run CLOSE position
8 Soft run CLOSE position
9 Soft start time OPEN
10 Soft start time CLOSE
7
Maintenance and
servicing
1 Door cycle counter
2 Servicing counter
3 Servicing interval
8 Reset maintenance and servicing
9 Fault indicator
8
System settings
1 Photocell
3 Automatic cut-out function
4 Operating modes
5 Function of the direction command
transmitters
6 Function of the impulse command
transmitters
7 Stress relief in the CLOSED door position
(back jump)
8 Direction of rotation
Operating instructions, Comfort 260 accu (#114332 – GB) 19
5.6.3 Contents of the special functions
Level 1 – Basic functions
Menu 3 – Intermediate OPEN position
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
The closing function with automatic closing is possible.
Only the intermediate position that was programmed last
can be used.
Menu 4 – Intermediate CLOSE position
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
The closing function with automatic closing is not possible.
Only the intermediate position that was programmed last
can be used.
Menu 8 – RESET
The operator system can be reset to the factory settings.
1 ) No reset
2 Reset the controls
3 Reset the remote control (telegrams are deleted)
4
Reset the special function: automatic closing timer
“Level 3 - Automatic closing timer”
5
Reset only the special operator functions (except
the OPEN/CLOSED door positions and the remote
control impulse)
6 Reset the safety elements (photocell / Hold circuit)
7
Reset bus modules (connected bus modules will be
programmed in)
Level 2 – Door operator settings
Menu 1 – Driving power required to OPEN
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving power).
) 8
Menu 2 – Driving power required to CLOSE
Sensitivity in on a scale of 1 to 16
(the higher the number, the greater the driving power).
) 8
Menu 3 – Automatic cut-out in the OPEN direction
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the automatic
cut-out).
) 10
Level 2 – Door operator settings
Menu 4 – Automatic cut-out in the CLOSE direction
Sensitivity on a scale of 1 (OFF) to 16
(the lower the number, the more sensitive the automatic
cut-out).
) 8
Level 3 - Automatic closing timer
Menu 1 – Automatic closing timer
If the automatic closing function is activated, the relay
output (Level 1 / Menu 7) can be reprogrammed if
required.
1 ) Deactivated
2
Door open
duration 15 /
Warning time 5
The open duration can
only be increased via an
impulse signal
(button or hand
transmitter).
3
Door open
duration 30 /
Warning time 5
4
Door open
duration 60 /
Warning time 8
5
Door open
duration 15 /
Warning time 5
The door open duration
ends after the photocell
has been triggered.
6
Door open
duration 30 /
Warning time 5
7
Door open
duration 60 /
Warning time 8
8
Door open
durationinnite/
Warning time 3
Door closes after the
photocell has been
triggered /
Closing prevention.
Menu 3 – Door open duration
2 – 250 seconds.
) Dependent on Level 3, Menu 1
Menu 4 – Warning time
1 – 70 seconds.
) Dependent on Level 3, Menu 1
Menu 5 – Start-up warning
0 – 7 seconds.
) 0
20 Operating instructions, Comfort 260 accu (#114332 – GB)
Level 6 – Variable speed
Menu 1 – OPEN speed
On a scale of 5 to 16.
) 16
Menu 2 – Soft run OPEN speed
On a scale of 1 to 16.
) 8
Menu 3 – Soft run OPEN position
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
Menu 4 – CLOSE speed
On a scale of 5 to 16.
) 16
Menu 5 – Smart run CLOSE speed
On a scale of 5 to 16.
) 8
Menu 6 – Soft run CLOSE speed
On a scale of 1 to 16.
) 8
Menu 7 – Smart run CLOSED position
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
Menu 8 – Soft run CLOSE position
Adjust the setting using the + (OPEN) and – (CLOSE)
buttons.
Menu 9 – Soft start time OPEN
1 ) Soft start time 1 second
2 Soft start time 2 seconds
3 Soft start time 3 seconds
4 Soft start time 6 seconds
Menü 10 – Soft start time CLOSE
1 ) Soft start time 1 second
2 Soft start time 2 seconds
3 Soft start time 3 seconds
4 Soft start time 6 seconds
Level 4 – Remote programming
Menu 2 – Intermediate OPEN position
Parameterindicatorashes->Pressthehandtransmitter
button->Handtransmitterdisplayalsoashes->
The function has been programmed.
Menu 3 – Intermediate CLOSE position
Parameterindicatorashes->Pressthehandtransmitter
button->Handtransmitterdisplayalsoashes->
The function has been programmed.
Menu 4 – OPEN
Parameterindicatorashes->Pressthehandtransmitter
button->Handtransmitterdisplayalsoashes->
The function has been programmed.
Menu 5 – CLOSE
Parameterindicatorashes->Pressthehandtransmitter
button->Handtransmitterdisplayalsoashes->
The function has been programmed.
Level 5 – Special functions
Programming of the special functions is dependent on terminal block
XB03.
“4.5.3 Terminal block XB03”
Menu 1 – Programmable impulse input (terminal 1/2)
1 ) Impulse (normally open contact only)
2
Closing prevention device (normally open contact
only)
3
Stops and reverses (only in the CLOSE direction –
normally closed contact only)
4
Stops and reverses (only in the CLOSE direction –
normally open contact only)
5
OPEN impulse (induction loop – normally open
contact only)
6
Earlier closing possible by pressing the buttons on
the input device or hand transmitter > 2 seconds
7
Impulse (normally open contact only)
with permanent 24 V DC / max. 50 mA
power supply
Menu 4 – Lighting duration
2 – 250 seconds.
) 1.2 (80 seconds)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Marantec Comfort 260 Owner's manual

Category
Garage Door Opener
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI