Paradox Hellas S.A. DGP2-641RB User manual

Category
Security access control systems
Type
User manual

This manual is also suitable for

User Guide for the
EVO96
DGP2-640
DGP2-641BL / DGP2-641RB
DGP2-648BL
Table of Contents
Introduction ...................................................................... 1
Legend................................................................................. 1
Basic Operation................................................................ 2
Auditory Feedback (Beep Tones)........................................ 2
Visual Feedback .................................................................. 3
Confidential Mode................................................................ 4
Partitioned System........................................................... 5
Area Display......................................................................... 5
Arming............................................................................... 6
Exit Delay Timer................................................................... 6
Regular Arming.................................................................... 6
Stay Arming ......................................................................... 6
Instant Arming...................................................................... 6
Force Arming ....................................................................... 6
Bypass Programming........................................................... 7
One-Touch Buttons.............................................................. 7
Keyswitch Arming ................................................................ 7
Auto-Arming......................................................................... 8
Disarming.......................................................................... 9
Entry Delay Timer................................................................ 9
Disarming an Armed System............................................... 9
Alarm Memory Display......................................................... 9
Access Codes................................................................. 10
System Master Code (Default 123456).............................. 10
Find Next Free User........................................................... 10
Copy User Options............................................................. 10
User Labels........................................................................ 11
Deleting User Access Codes............................................. 12
Programming User Access Codes..................................... 12
User Options...................................................................... 14
Access Control User Options............................................. 15
Using Access Control.................................................... 17
Entering & Exiting .............................................................. 17
Arming and Disarming with Card ....................................... 17
How Access Control Works ............................................... 18
Trouble Display .............................................................. 19
Trouble Display.................................................................. 19
Event Record Display ........................................................ 20
Additional Features........................................................ 21
Programmable Outputs (PGMs) ........................................ 21
Keypad Settings................................................................. 21
Set Time & Date................................................................. 22
Programming Chime Zones............................................... 22
Panic Alarms ..................................................................... 22
Quick Function Buttons ..................................................... 23
Testing and Maintenance............................................... 24
Burglar Alarm Testing........................................................ 24
Fire Alarm Testing............................................................. 24
System Maintenance......................................................... 24
System Test....................................................................... 24
Fire and Burglar Alarms................................................. 25
Standard Fire Zone............................................................ 25
Delayed Fire Zone............................................................. 25
Fire Safety Tips ................................................................. 25
Minimizing Home Fire Hazards ......................................... 26
Home Fire Warning System .............................................. 26
Burglar Alarm..................................................................... 26
Appendix 1: Hebrew Special Characters...................... 27
Appendix 2: Russian Special Characters..................... 28
Appendix 3: Greek Special Characters......................... 29
INDEX.......................................................................... 30
User’s Manual 1
1.0 Introduction
Your EVO96 System is an advanced technology security system that will provide you with reliable security protection and
powerful features that are easy to use. The elegant and user-friendly keypads will allow you easy access to your security
system's functions and information at the touch of a button. Depending on which keypad you have selected, the 32-character
LCD screen will display messages and menus to guide you through the system’s operations on the DGP2-641BL/RB keypad,
or the icons of the DGP2-640 and the DGP2-648BL LED display will let you assess the system status at a glance. Your
installer can even customize the messages for your home or business for the LCD keypads.
Since you will communicate your instructions to your system through the keypad, please read this manual carefully and have
your installer explain basic system operation.
1.1 Legend
Indicates a warning or an important note.
Indicates useful information or a tip.
[
TEXT] Indicates information that must be entered on the keypad.
Indicates a DGP2-641BL/RB instruction or information.
Indicates a DGP2-640 instruction or information.
Indicates a DGP2-648BL instruction or information.
LCD
ICON
LED
2 EVO96
2.0 Basic Operation
The following sections will introduce you to the roles of the buttons, lights, and messages on your keypad.
Figure 1: DGP2-641BL/RB Basic Overview
Figure 2: DGP2-648BL LED Keypad Overview
2.1 Auditory Feedback (Beep Tones)
When you enter information on the keypad, the keypad will guide you with beep tones to
communicate the acceptance or rejection of your entries.
Confirmation Beep: When an operation (i.e. arming/disarming) is successfully entered or
when the system switches to a new status/mode, the keypad emits an intermittent beep
tone (“
BEEP-BEEP-BEEP-BEEP-BEEP”).
Rejection Beep: When the system reverts to a previous status, or when an operation is
incorrectly entered, the keypad emits a continuous beep tone (“
BEEEEEEEEEEP”).
The LCD screen will guide you
with detailed messages.
Use the arrow buttons to scroll
through the current menu when the
arrows appear in the LCD screen.
Action Buttons:
Each button’s function is explained in the following sections of the manual.
STATUS Light:
When Green:
ON = All zones are closed.
OFF = One or more zones are open.
FLASH = Exit Delay in progress
When Red:
ON = Area(s) armed
OFF = Area(s) disarmed
FLASH = System in Alarm
AC Light:
ON = AC power
OFF = Power failure
AREA Lights: (A1, A2, A3 and A4)
ON = Area armed
OFF = Area disarmed
FLASH = Area in alarm
The keypad will display the status
of all its assigned areas.
ACTION Lights: (Access, Stay,
Force, Byp, Mem, Trbl and Prg)
Lights will illuminate according to
the status of the system.
Numerical Lights: (Zones)
ON = Zone is open
OFF = Zone is closed (OK)
FLASHES = Zone / fire loop
AC Light:
ON = AC Power (OK)
OFF = Power failure
STATUS Light:
When green:
ON = All zones closed
OFF = One or more zones are open
FLASH = Exit Delay in progress
When red:
ON = Area(s) armed
OFF = Area(s) disarmed
FLASH = System in Alarm
User’s Manual 3
2.2 Visual Feedback
The icons on the keypad’s screen communicate your system’s status as outlined in
Table 1.
Table 1: Icon Display and Functionality
Table 2: Additional Icon Keypad Visual Feedback
ICON
Icon(s) Display and Functionality
Indicates numbers corresponding to zones and option
numbers. If a zone or zones are open, their
corresponding number(s) will appear.
Indicates which areas are Force armed. Refer to
Force Arming on page 6.
Indicates which areas are Regular armed. Refer to
Arming on page 6.
Indicates which areas are Instant armed. Refer to
Instant Arming on page 6.
Indicates which areas are Stay armed. Refer to Stay
Arming on page 6.
Indicates the numerical values for the time, sections,
zones, options and codes.
Indicates which zones are in Chime Mode. Refer to
Programming Chime Zones on page 22.
Indicates a tamper situation in the system. Refer to
Trouble Display on page 19 and Group 5: Zone
Tamper on page 19.
Indicates a fire zone situation in the system. Refer to
Fire and Burglar Alarms on page 25.
Indicates system troubles. Refer to Trouble Display on
page 19.
Indicates bypassed zones. Refer to Bypass
Programming on page 7.
Indicates alarms stored in memory. Refer to Alarm
Memory Display on page 9.
Light Function Display Status
AC Light ON Power ON
OFF Power OFF
Status
Light
Green ON All zones closed
Green OFF Zone(s) open or in tamper
Green flash Exit delay
Red ON Area(s) armed
Red OFF Area(s) disarmed
Red flash System in alarm
4 EVO96
For all keypads, the [ENTER] or [] key will save and exit, and the [CLEAR] or
[] key will exit without saving. [
ENTER] and [CLEAR] represent both the Icon’s
enter and clear keys and the LCD/LED keypads’ enter and clear keys unless both
keys are shown to have a different function.
2.3 Confidential Mode
Your installer can program keypads to not display the status of your system automatically
by changing the keypad to Confidential Mode.
In Confidential Mode:
The zones, status messages and status icons will NOT be displayed
The indicator lights will NOT illuminate
Depending on how your keypad was programmed by your installer, you must either
press a button or enter your user access code to illuminate the indicator lights and
activate Normal Mode.
LCD ICON LED
User’s Manual 5
3.0 Partitioned System
Your installer can set your keypad to recognize separate protected areas. A separated system is called a partitioned system,
which can be useful in situations where shared security systems are more practical. For example, a company that has both
an office and a warehouse area, can arm and disarm each area separately while controlling access to each area. Therefore,
one person may have access to only one area, whereas another person may have access to all areas. Access to the areas is
determined by the User Access Code.
3.1 Area Display
The Area Status Display enables you to see the status of the individual areas within a
partitioned system. Your installer can partition the system into separate areas.
To view the status of the areas:
1. Enter your [
ACCESS CODE], and then press the [1] button.
2. Press the button corresponding to the area (i.e. 1, 2,...8), or use the [S] and [T]
buttons and press [
ENTER] when the area you want to view appears on the screen.
3. Press [
CLEAR] or [] to exit.
In Area Status Display mode, the following information will scroll on the LCD screen:
ready: if all zones in the selected area are closed.
not ready: if zones in the selected area are open.
Front Door Open: if there is an open zone within that area.
Trouble(s): (section 8.0 on page 19) if a trouble has occurred.
Alarms in Memory: (section 5.3 on page 9) if an alarm has occurred.
Armed; Force Armed; Instant Armed; Stay Armed: displays the
arming status of the selected area.
On the DGP2-640 keypad, specific icons will light up to indicate the status. Refer to
Table 1, “Icon Display and Functionality,” on page 3 for additional information.
In Area Status Display, the following will illuminate for the area selected:
The area lights (A1, A2, A3, and A4) if the associated area is armed. For example, if
you have selected area 3 and it is currently armed, A3 will illuminate.
The numerical light(s) representing any open zone(s) in a corresponding area or
areas.
•The M
EM action light if any alarms have occurred.
•The T
RBL action light if any troubles are occurring.
•The S
TAY action light if the area is Stay or Instant Armed.
•The F
ORCE action light if the area is Force Armed.
•The B
YP action light if zones are bypassed.
LCD
ICON
LED
6 EVO96
4.0 Arming
When your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending a report to
your monitoring station.
4.1 Exit Delay Timer
When you arm your system, it will trigger the Exit Delay Timer to provide you with enough
time to exit the protected area before the system is armed. The light and the
appropriate arm icon will both flash during the exit delay on the DGP2-640
keypad. (Refer
to Table 1 on page 3)
4.2 Regular Arming
This method is used for the everyday arming of your system. All zones within the
protected area must be closed to Regular arm the system.
To Regular arm the system:
1. Enter your [
ACCESS CODE].
2. Press the [
ARM] button or the [] key.
3. If you have access to more than one area, select the area(s) you wish to Regular arm
(refer to section 3.1 on page 5).
4.3 Stay Arming
Stay arming will partially arm your system to permit you to remain in your home or office
by arming the outer zones (perimeter) of the protected area (i.e. doors and windows).
To Stay arm:
1. Enter your [
ACCESS CODE].
2. Press the [
STAY] button or the [] key.
3. If you have access to more than one area, select the area(s) you wish to Stay arm
(refer to section 3.1 on page 5).
4.4 Instant Arming
This feature is the same as Stay arming except that there is no Entry Delay. Therefore,
any armed zone that is breached will immediately generate an alarm.
To Instant arm:
1. Enter your [
ACCESS CODE].
2. Press the [5] button.
3. If you have access to more than one area, select the area(s) you wish to Instant arm
(refer to section 3.1 on page 5).
4.5 Force Arming
Force arming allows you to quickly arm your system when zones are open. However,
once the open zone is closed, your system will then arm that zone as well.
To Force arm:
1. Enter your [
ACCESS CODE].
2. Press the [
FORCE] button or the [] key.
3. If you have access to more than one area, select the area(s) you wish to Force arm
(refer to section 3.1 on page 5).
LCD ICON LED
LCD ICON LED
LCD ICON LED
LCD ICON LED
LCD ICON LED
User’s Manual 7
4.6 Bypass Programming
You can bypass certain zones when you arm the protected area(s). When a zone is
bypassed, it will be ignored the next time your system is armed. Once your area is
disarmed, the system will unbypass the zone.
To Bypass a zone:
1. Enter your [
ACCESS CODE].
2. Press the [
BYP] button or the [] key.
3. Enter the zone number (i.e. 01, 02,...96), or use the [S] and [T] buttons and press
[
BYP] or [] once the zone you want to bypass appears on the screen. If
bypassed, the icon or the byp light does not appear on the screen and the
keypad emits a rejection beep, you may not have access to bypass that zone.
4. Repeat step 3 until all zones you want to bypass have been selected.
5. Press the [
ENTER] button to save and exit.
In order to bypass a zone, the following conditions must be met:
The zone must have the Bypass option programmed by your installer.
The Bypass option must be enabled in your User Options.
Your user access code must have access to the zone’s Area Assignment.
The zone’s area must be disarmed before the zone can be bypassed.
Fire Zones cannot be bypassed.
4.6.1 Bypass Recall
Bypass Recall reinstates the zones that were bypassed the last time your system
was armed.
To activate Bypass Recall:
1. Enter your [
ACCESS CODE].
2. Press the [
BYP] button or the [] key.
3. Press the
[MEM] button or the [] key.
Zones bypassed the last time your system was armed are bypassed.
4. Press the [
ENTER] button to save and exit.
4.7 One-Touch Buttons
If enabled by your installer, you can access the following features without using your user
access code by pressing and holding the desired One-Touch button.
Table 3: One Touch Button
4.8 Keyswitch Arming
A key can be used to arm and disarm your system using two forms of keyswitches. With a
Maintained Keyswitch, place the key in the “ON” position to arm your system, and place
the key in the “OFF” position to disarm your system. With a Momentary Keyswitch, place
the key in the “ON” position briefly then place it back in the “OFF” position to arm the
system. Repeat this process to disarm with a Momentary Keyswitch.
LCD ICON LED
LCD ICON LED
Button
Icon
Feature
[ARM]
[]
Regular arm
[
STAY]
[]
Stay arm
[
FORCE]
[]
Force arm
[
BYP]
[]
Bypass Programming
[
DISARM]
[]
Disarm a Stay/Instant armed area
[5] Instant arm
[6] Change display settings
[7] View Event Record display (DGP2-641BL/RB only)
LCD ICON LED
8 EVO96
4.9 Auto-Arming
If enabled by your installer, you can set the time that an area will arm itself automatically.
4.9.1 Timed Auto-Arming
Your installer can set Timed Auto-Arming to function in either Force or Stay arming
mode. A sixty-second (default value) Exit Delay sequence will begin prior to your
system automatically arming itself at the programmed time.
To set the Auto-Arming timer:
1. Enter your [
ACCESS CODE].
2. Press the [0] button.
3. Press the [
MEM] button or the [] key.
4. If you have access to more than one area, press the area’s
number, or use the
[S] and [T] buttons and press the [
ACC] button when the area you want to
program appears on the screen.
5. Enter the time you want the area to be armed according to the 24-hour clock
(i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit.
If you are using the DGP2-648BL keypad, The
MEM action light will flash if a
time is not already programmed. The
PRG action light, the area light of the
chosen area, and the first number of the previous time set will illuminate (
10
light = zero).
4.9.2 No Movement Auto-Arming
Your system can be programmed to send a report to your monitoring station and/or
arm the system if there is no activity in the area during a specified period of time.
Your installer can set No Movement Auto-Arming to function in either Regular or
Stay arming mode.
LCD ICON LED
User’s Manual 9
5.0 Disarming
When your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will not be
triggered if zones are breached.
5.1 Entry Delay Timer
Your installer will program designated entry points (i.e. the front door) with an Entry Delay
Timer. This delay gives you time to enter the armed premises and enter your code to
disarm your system before the alarm is triggered.
5.2 Disarming an Armed System
You can only disarm an area to which your user access code is assigned. User access
codes with the “Arm Only” (section 6.7 on page 14) option enabled cannot disarm an
armed system.
How do I disarm the system?
1. Enter your [
ACCESS CODE].
2. Press the [
DISARM] button or the [] key. If you have access to more than one area,
select the area(s) you wish to disarm (refer to section 5.2 on page 9).
To disarm a system in alarm:
1. Enter your [
ACCESS CODE].
2. In the case of a false alarm, call your monitoring station quickly to advise them of the
false alarm.
In the case of a burglar alarm, leave the premises and call the Police from a
safe place.
5.3 Alarm Memory Display
Your system will record all the alarms that occurred during the last armed period. The
zones in alarm will remain in the Alarm Memory until the next time that area is armed.
How do I view the list of alarms that occurred?
1. When an alarm has occurred, the DGP2-641BL/RB keypad’s screen will display
Alarms in Memory [mem] to View, the Memory icon or the
MEM action
light will illuminate.
2. Press the [
MEM] button or the [] key. The Memory icon will flash.
Each zone that was breached while armed will appear below Alarm in:.
Zone icons on the left side of the screen will illuminate to display zones that caused an
alarm.
The
MEM action light will flash and the numerical light(s) for each zone whose alarm
was triggered will illuminate.
3. Press the [
CLEAR] button to exit the Alarm Memory Display.
LCD ICON LED
LCD ICON LED
LCD
ICON
LCD
10 EVO96
6.0 Access Codes
Access Codes allow access to the system. Your system supports up to 999 user access codes. Codes are given a User
Number between 002 and 999 (User Number 001 is the System Master Code). Your installer will program user access codes
to be four, six, or variables of one to six digits in length. Each digit can be any value between zero and nine. If your installer
programmed your system to accept a variable code length, you have to press the [
ENTER] button after entering your user
access code.
6.1 System Master Code (Default 123456)
The System Master Code will give you access to all the features available on your
system, as well as the ability to add, modify, or delete any user access codes. We suggest
that you change this code to prevent others from accessing and changing options without
authorization. Your installer can set the System Master Code to be either 4 or 6 digits in
length.
To change the System Master Code:
1. Enter the current [S
YSTEM MASTER CODE] (default: 123456).
2. Press the [0] button.
3. Press the [
ACC] button or the [] key.
4. Enter the numbers [0] [0] and [1].
5. Enter a [
NEW CODE].
6. Press the [ENTER] button to save and exit.
If there are more than 4 areas in the system, the System Master Code cannot
be modified using the DGP2-640 keypad.
The System Master Code has access to all Access Control doors and all
Access Control features at all times. Only the card’s serial number and the
choice of arming method can be changed. If the other options are manually
changed, the System Master Code will immediately revert to its original
programming.
You can assign a label (name) to a user access code at any point during the
“Programming User Access Code” process. Refer to section 6.4 on page 11 to
assign a User Label.
6.2 Find Next Free User
This feature automatically searches your system for the next available unassigned user
access code.
To find the next free user:
1. Enter your [
ACCESS CODE] (System Master Code or user access code with Master
feature).
2. Press the [0] button, and then the [
ACC] button.
3. Press the [
BYP] button.
4. Program the user access code as detailed in section 6.6.1 on page 13 starting from
step 5.
6.3 Copy User Options
This feature allows you to copy the User Options, Access Control Options, and Area
Assignments from one user access code to another. All User Options are copied except
the User Code, Card Assignment, and User Label.
To copy user options:
1. Enter your [
ACCESS CODE] (System Master Code or user access code with Master
feature).
2. Press the [0] button, and then the [
ACC] button.
3. Enter the 3-digit User number you wish to copy TO.
4. Press the [
MEM] button.
5. Enter the 3-digit User number you wish to copy FROM.
LCD ICON LED
LCD
LCD
User’s Manual 11
6. Enter a user code. If the user code is of variable length, press the [ENTER] button after
entering the user code. If necessary, assign an Access card (step 13 in section 6.6.1
on page 13) and User Label (section 6.4 on page 11).
7. Press [
ENTER] to save and exit.
6.4 User Labels
User labels personalize user access codes and can be assigned by pressing [ENTER] at
any point after step 4 during the programming of user access codes (refer to section 6.6.1
on page 13). For Example, the DGP2-641BL/RB keypad can display
John Smith Select Action.
To program a user label:
1. At any point after step 4 in section 6.6.1 on page 13:
2. Press the [
ENTER] button.
3. Type the desired characters as detailed in section 6.4.1 on page 11 and section 6.4.2
on page 11.
4. Press the [S] button to move the cursor to a new space.
5. Repeat steps 2 and 3 until the desired label is complete.
6. Press the [
ENTER] button to save and exit.
6.4.1 Keypad Buttons
Every numeric button on your DGP2-641BL/RB keypad is assigned a set of letters.
To obtain the desired letter using the numeric buttons on your keypad, press the
button until the desired letter appears on the screen. For example, if you wanted to
enter the letter “C” you would press the [1] button three times (refer to Table 4 on
page 11). If using a Hebrew keypad, refer to Table 8 in Appendix 1: Hebrew Special
Characters on page 27. If using a Russian keypad, refer to Table 10 in Appendix 2:
Russian Special Characters on page 28. If using a Greek keypad, refer to Table 12
in Appendix 3: Greek Special Characters on page 29.
Table 4: Keypad Letter Assignments
6.4.2 Special Function Keys
[STAY] = Insert Space
Pressing the [
STAY] key inserts a blank space in the current cursor position.
[
FORCE] = Delete
Pressing the [
FORCE] key will delete the character or blank space found at the
current cursor position.
[
ARM] = Delete Until the End
Pressing the [ARM] key will delete all characters and spaces to the right of the
cursor and at the cursor's position.
LCD
Key
Press Key
Once
Press Key
Twice
Press Key
Three Times
[1] A B C
[2] D E F
[3] G H I
[4] J K L
[5] M N O
[6] P Q R
[7] S T U
[8] V W X
[9] Y Z
12 EVO96
[DISARM] = Numeric Keys / Alphanumeric Keys
Every time the [
DISARM] key is pressed it will toggle from numeric keys to
alphanumeric keys and vice versa. Numeric: Keys [0] to [9] represent numbers 0
to 9.
[
BYP] = Lower Case / Upper Case
Every time the [
BYP] key is pressed it will toggle the case setting from lower to
upper case and vice versa.
[
MEM] = Special Characters
After pressing the [
MEM] key, the cursor will turn into a flashing black square. Using
Table 5 on page 12, enter the 3-digit number that represents the desired symbol. If
using a Hebrew keypad, refer to Table 7 in Appendix 1: Hebrew Special Characters
on page 27. If using a Russian keypad, refer to Table 10 in Appendix 2: Russian
Special Characters on page 28. If using a Greek keypad, refer to Table 12 in
Appendix 3: Greek Special Characters on page 29.
Table 5: Special Characters Catalogue
6.5 Deleting User Access Codes
To delete user access codes, follow steps 1 to 5 in section 6.6.1 on page 13 or section
6.6.2 on page 14, but press the [
CLEAR] button or the [] key in Step 5. Once the
information is erased, press the [ENTER] button to save and exit.
6.6 Programming User Access Codes
The System Master and Users with the Master feature can program user access codes
with User Options and Area Assignments. The section 6.6.1 on page 13 describes the
steps you would follow to program user access codes. If you wish to program user access
codes using the NEware Software, please contact your installer for information.
LCD ICON LED
LCD ICON LED
User’s Manual 13
If the keypad emits a rejection beep at any point during the programming procedure, you
may have chosen an existing user code or you do not have access to certain User
Options (section 6.7) and Area Assignments (step 7 in section 6.6.1 on page 13). Users
with the Master feature can only assign User Options and Area Assignments that they are
assigned to. For example, if a User with the Master feature is assigned User Option 1 and
Area 2, they can only assign Options 1 and Area 2 to a user access code. The visual
feedback will differ on keypads other than the DGP2-641BL/RB.
6.6.1 Programming User Access Codes
1. Enter your [ACCESS CODE] (System Master Code or user access code with Mas-
ter feature).
2. Press [0] to enter the Programming Menu.
3. From Programming Menu, press [
ACC] or the [] key.
4. Enter the 3-digit User Number you want to program; press the [T] button to
scroll the list of codes and then press [
ACC] once the desired code appears on
the screen; or to “Find Next Free User” press the [
BYP] button (DGP2-641BL/
RB only) (refer to section 6.2 on page 10).
5. Enter a user code within the brackets. Press the [S] button or the [] key to
reach the User Options screen.
6. NOTE: The user code is a Personal Identification Number (P.I.N.).
7. Program the User Options by pressing the number on your keypad
corresponding to the User Option you wish to enable. The option is considered
ON when the number appears within the brackets
. Proceed to step 7 by
pressing the [S] button or the [] key. For a detailed description of the User
Options refer to section 6.7 on page 14
.
8. Users are able to perform actions (arming, disarming, etc.) only in the area(s)
they are assigned. To assign an area(s) to a user access code, enter the
number corresponding to the area you wish to assign (i.e. [1] = area 1, ...[8] =
area 8).
9. Press the [T] button to return to the User Options; press the [S] button or the
[] key to proceed to step 8; or press the [
ENTER] button to save and exit
programming mode.
NOTE: If no area is assigned, and if PGMs are programmed by your
installer, the user can only control the PGMs. Refer to section 9.1 on page
21 for a more detailed explanation of PGMs.
10.Enter the 2-digit Access Level (i.e. 00, 01,...15) within the first set of brackets.
An Access Level determines which Access Control doors a User is allowed to
pass through. There are 15 possible Access Levels which are usually
programmed by your installer. If you wish to program the Access Levels
yourself, you will need the NEware Software which is available through your
installer. Access to all Access Control doors is Access Level 00.
11. Enter the 2-digit Schedule (i.e. 00, 01,...15) in the second set of brackets.
Schedules, programmed by your installer, determine the hours, days, and
holidays that Users are permitted through Access Control doors. Each user is
assigned a Schedule through the user access code. To provide access at all
times, assign Schedule 00.
12.Program the Access Control User Options by pressing the number on your
keypad that corresponds to the Option you wish to assign. The option is
considered ON when the number appears within the brackets. For a detailed
description of the User Access Control Options, refer to section 6.8 on page 15.
Press the [S] button to proceed to step 10.
LCD ICON
14 EVO96
Option [1]: Access Control
Option [2]: Can Disarm with Access Card
Option [3]: Extended Unlocked Period
Options [4] and [5]: Arming with Card
[4] ON, [5] OFF:Regular Arm
[4] OFF, [5] ON:Stay Arm
[4] and [5] ON:Force Arm
[4] and [5] OFF:Disable the Arming with Card feature
Option [6]:Add Tolerance Window to Schedule
Option [7]:Code Follows Schedule
Option [8]:Card to Unlock and Code to Disarm
13.Enter the Access Control card’s serial number within the brackets.
14.Press the [
ENTER] button to save and exit.
6.6.2 Programming User Access Codes with the DGP2-648BL
1. Enter your [SYSTEM MASTER CODE] or [ACCESS CODE] with Master feature.
2. Press the [
0] key to enter the User Programming Menu. The area lights of
areas assigned to your User Access Code and the PRG action light will flash.
3. Press the [
ACC] key. The area lights of the areas assigned to your User Access
Code and the
ACCESS action light will illuminate. The PRG action light will
continue to flash.
4. Enter a 3-digit number (002 to 999) you wish to program. The
ACCESS action
light will flash for an unused code. If the code is used,
PRG action light and the
first number of the code will illuminate. The
ACCESS action and area light will turn
off.
5. Enter a User Code. If you do not want to change an existing one, press the
[U]
key until you reach User Options. Your keypad will emit a Half Beep when it
switches to User Options. Pre-existing options will illuminate.
6. Program the User Options by turning the options “ON” or “OFF”. Once the
options are programmed, press the
[U] key to reach the Area Assignment. Your
keypad will emit a Half Beep when it switches to Area Assignment. Pre-existing
assignments will illuminate.
7. Program the Area Assignment. Press the
[V] key to return to User Options or
press [
ENTER] to save and exit. Your keypad will emit a Confirmation Beep to
confirm the code’s acceptance.
6.7 User Options
Options [1] and [2]: Master Feature
When option [1] is OFF, the User cannot program other users into the system.
When option [1] is ON and option [2] is OFF, the user can program and modify user
access codes (P.I.N. only) and User Labels.
When both options [1] and [2] are ON, the user has Full Master rights. The user can
create or modify user access codes, User Options, User Access Control Options, Access
Card Numbers, User Labels and Area Assignments according to their own programming.
For example, if the Full Master User has access to area #1 and option [4] (Bypass) only,
the Full Master user can only assign area #1 and option [4] to other users in the system.
Option [3]: Duress
When option [3] is ON, the Duress feature is enabled. This feature is used when someone
forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.)
reserved for the Duress feature, the system will arm or disarm the area(s), and then send
a silent alarm to the monitoring station.
LCD ICON LED
LCD ICON LED
User’s Manual 15
Option [4]: Bypass
When option [4] is ON, the Bypass feature is enabled. This feature allows the user to
deactivate zones when arming the area(s).
Option [5]: Arm Only
When option [5] is ON, the Arm Only feature is enabled. The user can arm assigned
areas with either a card or code, but cannot disarm. When the option is OFF, the user can
either arm or disarm assigned areas.
Option [6]: Stay & Instant Arm
When option [6] is ON, the Stay and Instant arm features are enabled. The user can now
Stay or Instant arm their assigned areas.
Option [7]: Force Arm
When option [7] is ON, the Force arm feature is enabled. The user can now Force arm
their assigned areas.
Option [8]: Area Access
When option [8] is ON, the keypad will permit access to all the areas assigned to the user
access code. When option [8] is OFF, the keypad will only permit access to the areas it
controls. For example, the keypad is assigned area 1 only, and your user access code is
assigned areas 1 to 8. If the option is ON, you can access all eight areas from the keypad.
If the option is OFF, you can only access area 1.
By default all users can Regular arm the system.
6.8 Access Control User Options
Option [1]: Access Control
When option [1] is ON, the user can gain access to an access control door when Access
Control is enabled in the system. A user that is not assigned to any partition, but has the
Access Control option (Option [1]) enabled, can now gain access to an access control
door by entering a code # (P.I.N.) and then pressing the [
ACC] keypad key. When the
option is OFF, the user cannot access an Access Control door.
Option [2]: Can Disarm with Access Card
When option [2] is ON, a User’s Access Control card can unlock and disarm an armed
Access Control door. When option [2] is OFF, follow the settings in option [8] on page 17.
For option [2] to function in the ON position, option [5] “Arm Only” in the
User Options must be disabled (refer to section 6.7 on page 14).
Option [3]: Card with Extended Unlocked Period
When option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked
Period” refers to the time period programmed into each Access Control door by your
installer that extends the unlocked time of the door. For example, if your installer sets the
Unlocked period of the door to 30 seconds and the Extended Unlocked Period to 15
seconds, a user access code with “Extended Unlocked Period” enabled will have a total of
45 seconds to pass through the door.
Options [4] and [5]: Arming with Card
Options [4] and [5] define the type of arming when arming with an Access Control card
(refer to section 7.2.1 on page 17). You can either Regular arm, Stay arm, Force arm, or
Disable the Arming with Card feature.
[4] ON, [5] OFF = Regular Arm
[4] OFF, [5] ON = Stay Arm
[4] and [5] ON = Force Arm
[4] and [5] OFF = Disable the Arming with Card feature
LCD ICON
16 EVO96
Option [6]: Add Tolerance Window to Schedule
When option [6] is ON, the Schedule Tolerance Window feature is enabled. This feature
extends a user’s scheduled access period through an Access Control door by the amount
programmed by your installer. For example, if the user’s assigned schedule for the door is
Monday to Friday from 9:00 a.m. to 5:00 p.m., and your installer sets the “Tolerance
Window” at one hour, the user with the “Schedule Tolerance Window” enabled will be able
to enter and exit one hour before and after their scheduled time for that door.
Option [7]: Code Follows Schedule
When option [7] is ON, users can use their access codes only during their scheduled
hours assigned in step 8 in section 6.6.1 on page 13. When the option is OFF, users can
use their access codes at any time.
Option [8]: Card to Unlock and Code to Disarm
Option [8] functions only if option [2] in section 6.8 is OFF. When option [8] is ON, a user
can use an Access Control card to unlock an armed Access Control door, however the
user must enter a user access code to disarm the armed area. When option [8] is OFF, a
user can gain access to an Access Control door only if the door’s area(s) is already
disarmed.
For option [8] to function in the ON position, option [5] “Arm Only” in the
User Options must be disabled (refer to section 6.7 on page 14).
User’s Manual 17
7.0 Using Access Control
7.1 Entering & Exiting
Depending on how your system is installed and on the type of keypad, there are various
ways to enter and exit Access Control doors:
Present your Access Control card to the reader or the
DGP2-641RB keypad. The system will verify that the
card is allowed access according to its assigned Access
Level and Schedule. If it is accepted, the system will
unlock the door. The reader’s light can be programmed
by the installer to turn green or extinguish briefly to
indicate that the door can be opened.
When the motion detector detects movement (Request
for Exit), it will unlock the door to permit passage from
inside.
Enter your user access code on the keypad and press
[
ACC].
If the Access Control door is on a “Door Unlocked
Schedule”, you may be able to open Access Control
doors without using a user access code or an Access
Control card. Depending on the door’s programming, the door can remain unlocked
during the entire programmed schedule or the door can unlock once a valid Access
Control card is presented to the reader during the schedule and then will remain
unlocked for the remainder of the schedule.
7.2 Arming and Disarming with Card
7.2.1 Arming with Card
presented to a door during its assigned Schedule (refer to step 8 in section
6.6.1 on page 13).
presented to a door within its assigned Access Level (refer to step 8 in section
6.6.1 on page 13).
programmed to allow arming (options [4] and [5] in section 6.8 on page 15).
assigned to all areas that are assigned to the Access Control door (refer to step
7 in section 6.6.1 on page 13), or assigned to at least one of the areas assigned
to the Access Control door depending on how your installer has programmed
the Access Control door.
7.2.2 Disarming with Card
To disarm and unlock an Access Control door when the area assigned to it is
armed, present your Access Control card to the reader or DGP2-641RB keypad
(door). The Access Control card must be:
presented to a door during its assigned Schedule (refer to step 8 in section
6.6.1 on page 13).
presented to a door within its assigned Access Level (refer to step 8 in section
6.6.1 on page 13).
programmed to allow disarming (option [2] in section 6.8 on page 15).
assigned to all areas that are assigned to the Access Control door (refer to step
7 in section 6.6.1 on page 13), or assigned to at least one of the areas assigned
to the Access Control door depending on how your installer has programmed
the Access Control door.
LCD ICON LED
LCD
DGP2-641RB only
LCD
DGP2-641RB only
18 EVO96
7.3 How Access Control Works
To illustrate how Access Control functions, we will use three simple Access Control
System examples:
Figure 3: Example A
Bonnie’s Access Control card is programmed with Access Level 01 and Schedule 01. If
she presents her card to the reader or the DGP2-641RB keypad on Door 02 on Tuesday,
August 3 at 3:00 p.m., she will gain access to the room.
Figure 4: Example B
If Bonnie presents her card to the reader or the DGP2-641RB keypad on Door 02 on
Saturday or on a Holiday at 3:00 p.m., she will be denied access.
Figure 5: Example C
If we change Bonnie’s Access Level to 02 and she presents her card to the reader or the
DGP2-641RB keypad on Door 02 on Tuesday, August 3 at 3:00 p.m., she will be denied
access.
LCD ICON LED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Paradox Hellas S.A. DGP2-641RB User manual

Category
Security access control systems
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI