WPE01 IP55

Timeguard WPE01 IP55 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Timeguard WPE01 IP55 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1. IMPORTANT. Switch off the electricity at the fuse box by removing the relevant
fuse or switching off the circuit breaker before proceeding with the installation.
WPE01 IP55 Connector Box Installation
2. Using a Philips screwdriver, separate the faceplate from the back box by
removing the four tapped screws located in each corner.
3. Using the back box as a template mark the position for the holes. Note the
back box must be mounted in the horizontal position, following the ‘TOP’
marking inside the back box. If the mounting position desired is uneven use
a sheet of marine ply as a base and fit the back box.
4. Drill the wall using a appropriate drill bit making sure not to infringe or
compromise any gas, water pipes or cables. Insert the rawl plugs into the
holes.
1
1
Deta Electrical Co Ltd, Panattoni Park, Luton Rd,
Chalton, Bedfordshire, LU4 9TT
EU - Unit 16, Ashbourne Ind. Est. Ashbourne,
Co. Meath, A84 W972 Ireland
WPE01
IP55 Connector Box Enclosure
X2 PG11 IP68 Cable Glands
23/50
Batch Code:
MOUNTING
SCREW x 2
2
5. Drill out the drain feature with a 5mm drill if required. Opening the drain hole
will reduce the IP rating of the product.
6. Secure the back box to the wall using suitable screws for the rawl plugs installed.
Ensure that the back box is correctly orientated following the ‘TOP’ marking
which is labelled inside.
7. Pass the 230V AC 50Hz supply and load cables through the cable glands, noting
the correct orientation of the supply and load positions. Use the earth terminal to
connect the incoming and outgoing earth conductors for earth continuity if
required. Note that the terminal blocks are not supplied with the enclosure
and the method of termination will be decided by the user/installer.
8. Once the mains supply is connected to the correct terminals, mount the face
plate over the back box aligning the four screws from the face plate to the four
mounting holes on the back box. Tighten until secured.
67.058.716 (Issue 1)
T.W - July 2023
Earth Terminal
1
Deta Electrical Co Ltd, Panattoni Park, Luton Rd,
Chalton, Bedfordshire, LU4 9TT
EU - Unit 16, Ashbourne Ind. Est. Ashbourne,
Co. Meath, A84 W972 Ireland
WPE01
IP55 Connector Box Enclosure
X2 PG11 IP68 Cable Glands