AccessPRO SF101 is a fingerprint reader and proximity reader with built-in proximity reader, RS232, RS485, and USB communications, and an optic sensor. It can be used for various purposes, such as:
- Access control: The device can be used to control access to a building or room by allowing only authorized individuals to enter.
- Time and attendance: The device can be used to track the time and attendance of employees or students.
- Security: The device can be used to enhance the security of a building or room by providing an additional layer of protection.
The AccessPRO SF101 is easy to install and use. It comes with a mounting paper that can be used to mark the location of the holes for the included anchors. The device can be screwed into place using the included screws.
Installation Manual SF101
1/8
SF101
Installation Manual
Fingerprint Reader / Proximity Reader
1. Device Installation.
1.1. Using the mounng paper as
reference make the perforaons
in the wall for the included
anchors.
2/8
1.2. Gently remove the sensor
cover.
1.3. Before screwing, put on
the rubber protecon and
ghten the four screws.
1.4. Aer screwing the device,
place the sensor cover.
Installation Manual SF101
Led Indicator
2. The parts of the SF101 are described below:
2. Reader Parts
3/8
Fingerprint Reader
Reader cover
Enroll Buon
(User Registry
)
Delete Buon
(Delete Users
)
Bell Buon
USB Connecon
Reset Buon
Installaon Manual SF101
3. Connecons
4/8
J6
SEN
AGND
BUT
NO
COM
NC
AL+
AL-
12V
AGND
D0
D1
RED
GREEN
BUZZER
12V
AGND
RXD
TXD
485A
485B
BELL+
BELL-
J8
J4
J6
FUNCTION
SEN Door Sensor
AGND Ground
BUT Output Buon
NO Normally open for
lock
COM Common for lock
NC Normally closed for
lock
AL+ Alarm output (+)
AL- Alarm output (-)
J8
FUNCTION
12V 12VCD+
AGND 12VCD-
D0 Wiegand Output D0
D1 Wiegand Output D1
RED LED Control
GREEN
BUZZER Buzzer Sound
J4
FUNCTION
RXD RS232 RX
TXD RS232 TX
485A RS485 +
485B RS485 +
BELL+ TIMBRE+
BELL- TIMBRE-
12VCD
Installaon Manual SF101
LED Control
3.1. Connecon Diagram of the SF101 with a Magnec Sheet Sharing the Same Source:
3. Connecons
5/8
J6
SEN
AGND
BUT
NO
COM
NC
AL+
AL-
12V
AGND
D0
D1
RED
GREEN
BUZZER
12V
AGND
RXD
TXD
485A
485B
BELL+
BELL-
J8
J4
12V+
12V-
12V-
12V+
N.C.
Magnec
Sheet
12VDC SHARED
POWER SUPPLY
N.A. Exit
Buon
N.C. Door
Sensor
Nota: The exit buon
and door sensor share
the GND as common.
Diode
Installaon Manual SF101
3.2. Connection diagram of the SF101 with a counterstrike sharing the same source:
3. Connections
6/8
J6
SEN
AGND
BUT
NO
COM
NC
AL+
AL-
12V
AGND
D0
D1
RED
GREEN
BUZZER
12V
AGND
RXD
TXD
485A
485B
BELL+
BELL-
J8
J4
12V+
12V-
12V-
12V+
12VCD SHARED
POWER SUPPLY
N.A. Exit
Buon
N.C. Door
Sensor
Note: The exit buon
and door sensor share
the GND as common
N.A. Electric
Strike
Diode
Installaon Manual SF101
3.3. Connecon diagram of the SF101 with an Access Control Panel:
3. Connecons
7/8
12V
AGND
D0
D1
RED
GREEN
BUZZER
J8
D0
D1
Cable AWG .22
GND
Access Control
Panel
3.4. Connecon diagram of the SF101 with the PC via USB:
PC
USB
Installaon Manual SF101
4. Characteriscs
8/8
More Informaon:
Youtube Channel
www.youtube.com/accessprosecurity
• Opc sensor.
• Communicaons: RS232, RS485 and USB.
• Built-in proximity reader.
• Voltage: 12 VDC.
• Operang temperature: 0 - 45 ºC.
• Dimensions: 120 x 120 x 35.1 mm.
Installaon Manual SF101