650-10 Changing the sewing equipment
0791 650703 EN 1
Fig. 1: Changing the sewing equipment (1)
To change the sewing equipment:
1. Switch off the machine.
2. Remove the rear cover.
3. Remove the needle.
4. Unscrew the coupling rods (1) from the sewing feet (7).
5. Remove the sewing feet (7).
6. Remove the conveyor belts (8).
7. Remove the sewing table (4).
8. Loosen the screws (3) so that the middle section holder ist loose enough to remove the
throat plate.
9. Remove the throat plate.
10. Assemble the new throat plate (5) and tighten screws (3).
Important!
Make sure that the middle section holder (2) is located in the cut-out provided for it in the hook.
(1) - Coupling rods
(2) - Middle section holder
(3) - Screw
(4) - Sewing table
(5) - new throat plate
(6) - new belt guides
(7) - Sewing feet
(8) - Conveyor belts
(9) - new sewing feet
③④
650-10 Changing the sewing equipment
0791 650703 EN 2
Fig. 2: Changing the sewing equipment (2)
11. Remove the belt guides (10) and assemble the new belt guides (6).
Important!
Use the sleeves from the old belt guides.
Make sure that the bevel of the inner belt guides is facing the machine arm.
12. Insert the conveyor belts into the new sewing feet (9).
13. Assemble the new sewing feet (9).
14. Screw the coupling rods (1) to the sewing feet.
15. Place and tension the conveyor belts (8) ( Service Instrucions).
16. Insert the needle and assemble the rear cover.
17. Switch on and calibrate the machine ( Service Instructions).
(9)- new sewing feet (10) - Belt guides