Optimus SMP-94RZ User manual

Type
User manual
INSTRUCCIONES
DE FUNCIONAMIENTO
GUIA DEL USUARIO
INSTRUCTIONS
DE FONCTIONNEMENT
GUIDE DE L’USAGER
OPERATING
INSTRUCTIONS
OWNER’S MANUAL
INSTRUCCIONS
DE FUNCIONAMENT
GUIA DE L’USUARI
SMP-94RZ, SMP-94RZ1
SMP-94RZ2 & SMP-94RZ3
· Antes de hacer funcionar este aparato, lea detenidamente estas instrucciones.
· Veuillez lire ces instruccions avant d’employer cet appareil.
· Before operating this unit, please read these instruccions completely.
· Abans de fer funcionar aquest aparell, llegeixi detingudament aquestes instruccions.
Nº.
SISTEMA MICROPROCESADO PARA LA SELECCIÓN DESCENTRALIZADA DE ZONAS
SYSTÈME MICROPROCESSÉ POUR SÉLECTION DÉCENTRALISÉE DE ZONES
MICROPROCESSOR DECENTRALIZED ZONES SELECTION SYSTEM
SISTEMA MICROPROCESSAT PER A LA SELECCIÓ DESCENTRALITZADA DE ZONES
CONTENTS.
1. Introduction...................................................................... 3
2. SMP-94RZ....................................................................... 5
2.1. Front view............................................................... 5
2.2. Rear view................................................................ 5
2.3. Installation .............................................................. 5
2.4. Configuration .......................................................... 9
3. SMP-94RZ1.....................................................................13
3.1. Front view...............................................................13
3.2. Rear view................................................................13
3.3. Installation ..............................................................13
3.4. Configuration ..........................................................15
4. SMP-94RZ2.....................................................................17
5. SMP-94RZ3.....................................................................17
6. Application diagram.........................................................18
7. Technical specifications ..................................................19
1. INTRODUCTION.
These products, combined with the SMP-94RS/RC zones
selector module, configure a system that allows to
decentralise the P.A. installations with zones selection and to
reduce the number of loudspeaker lines, hence, the
installations are cheaper and more simplified.
It also allows to easily redistribute the zones not needing to
change the cables.
Elements of the system:
a) SMP-94RZ.
It is an encoder / decoder that, combined with the SMP-
94RS/RC desk, allows to select up to 240 zones.
It is the junction element between the SMP-94RS desks and
the SMP-94RZ1 zones selectors
b) SMP-94RZ1.
It is a zone selector.
It receives the signals from the program and priority lines, and
the binary code of zone activation.
The assignment of the zone number is made by a dipswitch
located in the same module; this allows an easy
reconfiguration of the system without changing the cables.
It has a three-wires output that allows to use this module in
installations with security paging.
c) SMP-94RZ2.
It is an opto-isolator module for the parallel communication
bus that allows to segment the installation in order to cover
long distances.
d) SMP-94RZ3.
It is a parallel bus end of line module. Each branch of the bus
must end with a SMP-94RZ3.
ÍNDEX.
1. Introducció ...................................................................... 3
2. SMP-94RZ ...................................................................... 5
2.1. Vista frontal ............................................................ 5
2.2. Vista posterior ........................................................ 5
2.3. Connexió................................................................ 5
2.4. Configuració........................................................... 9
3. SMP-94RZ1 ....................................................................13
3.1. Vista frontal ............................................................13
3.2. Vista posterior ........................................................13
3.3. Connexió................................................................13
3.4. Configuració...........................................................15
4. SMP-94RZ2 ....................................................................17
5. SMP-94RZ3 ....................................................................17
6. Diagrama d’aplicació.......................................................18
7. Característiques tècniques..............................................19
1. INTRODUCCIÓ.
Aquests elements, en combinació amb el pupitre selector de
zones SMP-94RS/RC, configuren un sistema que permet
descentralitzar les instal·lacions de megafonia amb selecció
de zones i reduir considerablement el nombre de línies
d'altaveu, abaratint i simplificant les instal·lacions.
Permet, a més, una fàcil redistribució de les zones sense
necessitat de variar el cablejat.
Elements del sistema:
a) SMP-94RZ.
És un codificador / descodificador que, en combinació amb el
pupitre SMP-94RS/RC permet seleccionar fins a 240 zones.
És l’element d’unió entre els pupitres SMP-94RS i els
selectors de zona (SMP-94RZ1)
b) SMP-94RZ1.
És un selector d'una zona.
Rep el senyals de les línies de programa i prioritat i el codi
binari d'activació de zona.
L’assignació del número de zona es fa mitjançant un dipswitch
ubicat en el mateix mòdul; això possibilita la fàcil
reconfiguració del sistema sense variar el cablejat.
Disposa d'una sortida de tres fils que permet utilitzar aquest
mòdul en instal·lacions amb seguretat d'avisos.
c) SMP-94RZ2.
És un mòdul optoaïllador pel bus de comunicació paral·lel que
permet segmentar la instal·lació per tal de cobrir llargues
distàncies.
d) SMP-94RZ3.
És un mòdul de final de terminació de bus paral·lel. Cada
branca del bus ha d’acabar amb un SMP-94RZ3.
3
2. SMP-94RZ.
2. 1. FRONT VIEW (figure 1).
1. Configuration of the decoder number (Section 2.4.).
2. Power supply input (Section 2.3.3.).
3. Connections to the serial communication bus (Section 2.3.1.).
4. Signal ground.
5. Frame.
2.2. REAR VIEW (figure 2).
1. Signal outputs (Section 2.2.1.).
2. ACK: Confirmation input (Section 2.2.2.).
3. Codification Outputs (Section 2.2.3.).
4. Start/Stop output (Section 2.2.4.).
5. +24 V.d.c. power supply input of the parallel communication
bus (Section 2.2.5.).
2. SMP-94RZ.
2.1. VISTA FRONTAL (figura 1).
1. Configuració del número de descodificador (Apartat 2.4.).
2. Entrada d'alimentació (Apartat 2.3.3.).
3. Connexions al bus de comunicació sèrie (Apartat 2.3.1.).
4. Massa de senyal.
5. Xassís.
2.2. VISTA POSTERIOR (figura 2).
1. Sortides de senyal (Apartat 2.2.1.).
2. ACK : Entrada de confirmació (Apartat 2.2.2.).
3. Sortides de codificació (Apartat 2.2.3.).
4. Sortida Start/Stop (Apartat 2.2.4.).
5. Entrada d'alimentació +24 V.c.c. del bus de comunicació
paral·lel (Apartat 2.2.5.).
5
FIG. 2
2.2.1. Signal Outputs (see figure 3).
They are two DIN 5 pins connectors (compatible with the rest
of Optimus equipment) connected in parallel.
The audio output level is 0dB and the impedance 5 kW.
The priority control is activated each time that a zone of the
receiver is selected.
2.2.2. ACK confirmation contact (see figure 4).
Through the b0 line, the zone selectors (SMP94RZ1) give
confirmation to the SMP-94RZ that they have been selected.
It is necessary to make a jumper between the ACK and b0
contacts.
2.2.3. Codification outputs (see figure 4).
Through these eight contacts (b0 - b7), the binary codes of
zone activation are sent to the SMP94RZ1 all around the
installation.
2.2.4. Start/Stop output (see figure 4).
This output enables the SMP-94RZ1 to read the parallel BUS
codification.
2.2.5. 24 V.d.c. input contacts (see figure 4).
Connecting a 24 V.d.c. power supply source between these
two contacts, the power supply is sent to the SMP-94RZ1
through a parallel bus.
2.2.1. Sortides de Senyal (veure figura 3).
Es tracta de dos connectors DIN de 5 pins (compatibles amb
la resta d'aparells Optimus) connectats en paral·lel.
El nivell de sortida d’àudio és de 0 dB i la impedància de 5 kW.
El control de prioritat s'activa cada vegada que es selecciona
alguna de les zones del receptor.
2.2.2. Contacte de confirmació ACK (veure figura 4).
A través de la línia b0, els selectors de zona (SMP-94RZ1)
donen confirmació al SMP-94RZ de que han estat
seleccionats.
Cal fer un pont entre els contactes ACK i b0 .
2.2.3. Sortides de codificació (veure figura 4).
A traves d'aquests vuit contactes (b0 - b7) s'envien els codis
binaris d'activació de zona cap als SMP-94RZ1 repartits per la
instal·lació.
2.2.4. Sortida Start/Stop (veure figura 4).
Aquesta sortida habilita als SMP-94RZ1 per que llegeixin la
codificació del bus paral·lel,
2.2.5. Contactes d'entrada 24 V.c.c. (veure figura 4).
Connectant una font d'alimentació de 24 V.c.c. entre aquests
dos contactes s’envia alimentació als SMP-94RZ1 a través del
bus paral·lel.
7
FIG. 4
2.3. INSTALLATION.
It is necessary to distinguish between:
Serial communication bus. The SMP-94RS, SMP-94R and
SMP-94RC are connected to it.
Parallel communication bus. The SMP-94RZ1, SMP-94RZ2
and SMP-94RZ3 are connected to it.
The SMP-94RZ is the junction element between the parallel
bus and the serial bus.
2.3.1. Connections to the serial communication bus.
The SMP-94RZ decoder connection to the serial
communication bus is made by means of the connectors
located in the front, as shown in figure 1a.
If it is an end of line, the 120W resistor must be connected
(see figure 1b).
For a wider information, read the Section 5.1. of the SMP-
94R/SMP-94RS Operating Instructions.
2.3.2. Connections to the parallel communication bus.
Each SMP-94RZ will have its parallel communication bus, to
which the zone selector (SMP-94RZ1) will be connected.
The number of conductors required in the parallel bus
depends on the number of zones (see Table 1).
The parallel communication bus must be power supplied with
a 24 V.d.c. in parallel, as shown in fig. 4, in order to supply the
SMP-94RZ1 zone selector modules.
2.3.3. Power supply connections.
The SMP-94RZ must be power supplied by means of the
serial communication bus, or by using a 24 V.d.c. power
supply source connected to the 24V.d.c. input (see figure 1,
number 1).
Fur a wider information, read the Section 5.1.3. of the SMP-
94R/SMP-94RS Operating Instructions.
2.4. CONFIGURATION.
All the decoders connected to the serial bus (the ones of the
SMP-94RZ, as well as of the SMP-94R) must be distinguished
from the rest by a decoder number. Hence, each decoder
occupies a pre-set position that must be programmed by
means of the dipswitches located on the front panel (see
figure 1, number 1).
These positions are from 1 to 31.
To configure each decoder with its corresponding position, it is
necessary to have in mind that:
Each SMP-94RZ occupies 10 positions.
Each SMP-94R occupies 1 position.
Each position occupies 24 zones.
Hence, a SMP-94RZ occupies 240 zones, even not all of them
are connected, and one SMP-94R occupies 24 zones, even if
not all of them are connected.
Figure 5 shows some examples on how to determine a
decoder number.
Table 2 shows the configuration of the dipswitch for each one
of the 31 positions.
2.3. CONNEXIÓ.
Cal diferenciar entre:
Bus de comunicació sèrie. S’hi connecten els elements SMP-
94RS, SMP-94R i SMP-94RC.
Bus de comunicació paral·lel. S’hi connecten els elements
SMP-94RZ1, SMP-94RZ2 i SMP-94RZ3.
El SMP-94RZ és l’element d’unió entre el bus paral·lel i el bus
sèrie.
2.3.1. Connexió al bus de comunicació sèrie.
La connexió del descodificador SMP-94RZ al bus de
comunicació sèrie es realitza mitjançant els connectors situats
a la part frontal tal i com indica la figura 1a.
Si es tracta d'un final de línia s'haurà de connectar la
resistència de terminació (120W)(Veure figura 1b).
Per a més informació cal llegir l'Apartat 5.1. de les
Instruccions de funcionament del SMP-94R/SMP-94RS.
2.3.2. Connexió al bus de comunicació paral·lel.
Cada SMP-94RZ tindrà el seu bus de comunicació paral·lel,
on s'hi connectaran els selectors de zona (SMP-94RZ1).
En funció del nombre de zones varia el nombre de conductors
necessari del bus paral·lel (veure Taula 1).
Cal alimentar el bus de comunicació paral·lel amb 24 V.c.c. tal
i com indica la figura 4, per tal d'alimentar els mòduls
selectors de zona SMP-94RZ1.
2.3.3. Connexió de l'alimentació.
Cal alimentar el SMP-94RZ mitjançant el bus de comunicació
sèrie o bé utilitzant una font d'alimentació de 24 V.c.c.
connectada a l'entrada de 24 V.c.c. (Veure figura 1, número 2).
Per a més informació cal llegir l'Apartat 5.1.3. de les
Instruccions de funcionament del SMP-94R/SMP-94RS.
2.4. CONFIGURACIÓ.
Tots els descodificador connectats al bus sèrie (tant els SMP-
94RZ com els SMP-94R) s'han de diferenciar dels altres
mitjançant un número de descodificador, que cal programar
mitjançant els dipswitchs situats a la placa frontal (Veure
figura 1, número 1). Així, cada descodificador ocupa una
posició determinada.
Aquestes posicions poden anar de 1 a 31.
Per configurar cada descodificador amb la seva posició
corresponent cal tenir en conte el següent:
Cada SMP-94RZ ocupa 10 posicions.
Cada SMP-94R ocupa 1 posició.
Cada posició ocupa 24 zones.
Per tant, un SMP-94RZ ocuparà 240 zones, estiguin o no
totes connectades i un SMP-94R ocupa 24 zones, estiguin o
no totes connectades.
La figura 5 mostra uns exemples de com determinar el
número de descodificador.
La Taula 2 mostra la configuració del dipswitch per a
cadascuna de les 31 posicions.
9
10
FIG. 5
3. SMP-94RZ1 Zone Selector Module
.
3. 1. FRONT VIEW (figure 6a).
1. Reset push-button (Section 3.1.1.).
2. Power supply input (Section 3.1.2.).
3. Start/Stop input contact (Section 3.1.3.).
4. Zone selection inputs (Section 3.1.4.).
3.1.1. Reset push-button.
When changing the configuration of a SMP-94RZ1, it is
necessary to press Reset so that the system identifies the new
configuration.
3.1.2. Power supply input.
The SMP-94RZ1 is power supplied through these two contacts.
3.1.3. Start/Stop input contact.
This contact enables the SMP-94RZ1 to read the control
information that is sent by the SMP94RZ through the parallel
BUS.
3.1.4. Zone selection inputs.
The zone activation binary code is received through these
eight contacts (b0 - B7).
3.2. REAR VIEW (figure 6b).
1. Number of zone configuration Dipswitches (Section 3.2.1.).
2. Output contacts (Section 3.2.2.).
3. PRIORITY input contacts (Section 3.2.3.).
4. PROGRAM input contacts (Section 3.2.4.).
3.2.1. Number of zone configuration Dipswitches.
By means of these Dipswitches, each SMP-94RZ1 is
configured with its number of zone (from 1 to 240 zones).
3.2.2. Output contacts.
The PROGRAM or PRIORITY output signal appears between
the contacts + and -C. There is a third contact S that is used
for security paging in 3-wires attenuators.
3.2.3. PRIORITY input contacts.
“PRIORITY” channel input contacts.
3.3.4. PROGRAM input contacts.
“PROGRAM” channel input contacts.
3.3. INSTALLATION.
Each zone needs a SMP-94RZ1 that must be configured with
its corresponding number of zone and connected to the
parallel communication bus (see figure 7).
The number of required conductors of the parallel bus
depends on the number of zones (see Table 1).
The parallel communication bus must be power supplied at 24
V.d.c., as shown in figure 4, in order to supply the SMP-94RZ1
zone selectors modules.
3. Mòdul Selector de zona SMP-94RZ1.
3. 1. VISTA FRONTAL (figura 6a).
1. Polsador de reset (Apartat 3.1.1.).
2. Entrada d'alimentació (Apartat 3.1.2.).
3. Contacte d'entrada Start/Stop (Apartat 3.1.3.).
4. Entrades de selecció de zona (Apartat 3.1.4.).
3.1.1. Polsador de reset.
Quan es canvia la configuració d'un SMP-94RZ1 cal polsar el
reset per fer que el sistema identifiqui la nova configuració.
3.1.2. Entrada d'alimentació.
A través d'aquests dos contactes s'alimenta el SMP-94RZ1.
3.1.3. Contacte d'entrada Start/Stop.
Aquest contacte habilita als SMP-94RZ1 per que llegeixin la
informació de control que envia el SMP-94RZ a través del bus
paral·lel.
3.1.4. Entrades de selecció de zona.
A traves d'aquests vuit contactes (b0 - B7) es rep el codi binari
d'activació de zona.
3.2. VISTA POSTERIOR (figura 6b).
1. Dipswitchs de configuració de número de zona (Apartat
3.2.1.).
2. Contactes de sortida (Apartat 3.2.2.).
3. Contactes d'entrada PRIORITY (Apartat 3.2.3.).
4. Contactes d'entrada PROGRAM (Apartat 3.2.4.).
3.2.1. Dipswitchs de configuració de número de zona.
Mitjançant aquests dipswitchs es configura cada SMP-94RZ1
amb el seu número de zona (de 1 a 240 zones).
3.2.2. Contactes de sortida.
El senyal de sortida PROGRAM o bé PRIORITY, surt entre
els contactes + i -C. Hi ha un tercer contacte S que s'utilitza
per a la seguretat d’avisos en atenuadors a 3 fils.
3.2.3. Contactes d'entrada PRIORITY.
Contactes d'entrada del canal "PRIORITY".
3.3.4. Contactes d'entrada PROGRAM.
Contactes d'entrada del canal "PROGRAM".
3.3. CONNEXIÓ.
Cada zona necessita un SMP-94RZ1 que cal configurar amb
el seu número de zona corresponent i connectar al bus de
comunicació paral·lel (veure figura 7).
En funció del nombre de zones varia el nombre de conductors
necessaris del bus paral·lel (veure Taula 1).
Cal alimentar el bus de comunicació paral·lel amb 24 V.c.c. tal
i com indica la figura 4, per tal d'alimentar els mòduls
selectors de zona SMP-94RZ1.
13
3.4. SMP-94RZ1 CONFIGURATION.
Each SMP-94RZ1 must be configured with a number of zone
(from 1 to 240) by means of the corresponding dipswitches
(figure 6b, number 1).
Follow table 3 to configure each SMP-94RZ1.
When a paging is sent to a zone by a desk, the SMP-94RZ1
module configured with that number switches the signal
received from the Program line (PROGRAM +/-) with the
signal received from the Priority line (PRIORITY +/-).
The number of zone of a module can be changed only altering
the position of the dipswitches, and pressing Reset (figure 6a,
number 1).
3.4. CONFIGURACIÓ SMP-94RZ1.
Mitjançant els dipswitchs corresponents (figura 6b, número 1),
cal configurar cada SMP-94RZ1 amb un número de zona (de
1 a 240).
Per a configurar cada SMP-94RZ1 cal seguir la Taula 3.
Quan, mitjançant un pupitre, es dóna un avís a una zona, el
mòdul SMP-94RZ1 configurat amb aquell número de zona
commuta el senyal que li arriba per la línia de Programa
(PROGRAM +/-) amb el senyal que li arriba per la línia de
Prioritat (PRIORITY +/-).
Si es vol canviar el número de zona d’un mòdul només cal
variar la posició dels dipswitchs i polsar el reset (figura 6a,
número 1).
TABLA 3 / TABLE 3 / TABLE 3 / TAULA 3.
15
4. SMP-94RZ2 Module (figure 8).
It is an opto-isolator module that allows to segment the parallel
communication bus, by dividing galvanically different parts of
the installation.
Please, ask to the OPTIMUS S.A. Technical Department to
determine its location.
5. SMP-94RZ3 Module (figure 9).
End of line module. It is required to connect it to each branch
of the parallel bus. It avoids that rebounds appear on the
codification lines.
4. Mòdul SMP-94RZ2 (figura 8).
És un mòdul optoaïllador que permet segmentar el bus
comunicació paral·lel, separant galvànicament diferents parts
de la instal·lació.
Cal consultar el Departament Tècnic d’OPTIMUS S.A. per a
determinar la seva ubicació.
5. Mòdul SMP-94RZ3 (figura 9).
Mòdul de terminació de línia. És necessari connectar-lo al
final de cada branca del bus paral·lel. Evita l’aparició de
rebots sobre les línies de codificació.
6. Diagrama de aplicación.
6. Diagramme d’application.
6. Application diagram.
6. Diagrama d’aplicació.
17
18
7. Características técnicas.
7. Caractéristiques techniques.
7. Technical specifications.
7. Característiques tècniques.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Optimus SMP-94RZ User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI