Raytheon Nautoconning, Synapsis Conning Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Raytheon Nautoconning Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Raytheon Anschütz GmbH
Postfach 1166
D -- 24100 Kiel
Germany
Tel+49--431--3019--0
Fax+49--431--3019--501
www.raytheon --anschuetz.de
4093.DOC000002 Edition: 29.MAR.2011
NAUTOCONNING
(Ethernet)
BOX--PC
System Description
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich
zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Copying of this document, and giving it to others and the use or
communication of the contents thereof, are forbidden without express
authority. Offenders are liable to the payment of damages.
Toute communication ou reproduction de ce document, toute
exploitation ou communication de son contenu sont interdites, sauf
autorisation expresse. Tout manquement à cette règle est illicite et
expose son auteur au versement de dommages et intérêts.
Sin nuestra expresa autorización, queda terminantemente prohibida la
reproducción total o parcial de este documento, así como su uso
indebido y/o su exhibición o comunicación a terceros. De los infractores
se exigirá el correspondiente resarcimiento de daños y perjuicios.
Raytheon Anschütz GmbH
Germany
R
NAUTOCONNING
A
4093DOC000002Edition: 29.MAR.2011
SAFETY NOTES:
S Warning!
Take care during maintenance and repair work: avoid
touching live electrical connections. The applicable
safety regulations such as VDE, VBG 4, OSHA 1919
and other appropriate safety standards must be fol-
lowed.
S The installation and first putting into operation may only
be performed by trained and qualified personnel.
S Maintenance and repair work may only be performed
by trained and qualified personnel having knowledge of
the national safety regulations for this type of equip-
ment.
S The equipment can be damaged!
Parts may only be replaced when the supply voltage is
switched off.
NAUTOCONNING
B
4093DOC000002 Edition: 29.MAR.2011
Table of Contents
Raytheon Anschütz GmbH
Germany
R
NAUTOCONNING
I
3885DOC000002Edition: 29.MAR.201 1
1 General 1--1..................................................................
1.1 Tasks and Performance features 1--2...........................................
1.2 Construction 1--4.............................................................
Diagrams:
See Cable Diagrams and Connecting Diagrams (according to order)
Additional Descriptions:
Navigation Data Manager 3884E
Conning Display 4094E
Alarm Transfer System 4095E
Computer 4090E
Raytheon Anschütz GmbH
Germany
R
NAUTOCONNING
1--1
4093DOC000002Edition: 29.MAR.201 1
1 General
NAUTOCONNING is the central display and data managem ent system for the
ship’s command.
Allying with Radar and ECDIS (Electronic See Chart) NAUTOCONNING can be
placed in a Multifunction Console (MF C).
The switching over between these applications taks place with a software switch
(MFC Switch) placed on the top corner right of the display.
NAUTOCONNING
1--2
4093DOC000002 Edition: 29.MAR.2011
1.1 Tasks an d Performance features
Read in and adaption of Navigation Data
- Log
-NavRec
-Wind
- Depth
-etc.
Read in and adaptation of Sensor Data
- Compass
- Autopilot
- ECDIS
-etc.
Sensor Monitoring
The Nautoconning software allows specific Alarm Level Settings for sensors
which will release alarms on Alarm Transfer System ATS.
Sensor Selecting
Redundant sensors can be selected from a scrollable list which indicates all
sensors and their current status.
Registration and management of alarms and the status of system devices
Built--in Watch Alarm Timer, configurable for W1--applications
(Function of Alarm Transfer System Conning Display)
Redundant Central Alarm Panel functionality for W1--applications
Raytheon Anschütz GmbH
Germany
R
NAUTOCONNING
1--3
4093DOC000002Edition: 29.MAR.201 1
Display of the registered data, alarms and procedure sequences (tracking) in
corresponding monitor displays:
- NAVIGATION
-DOCKING
- SENSOR
-ALARM
- ONDUTY
-RECORD
Distribution of the data and alarms to connected devices.
NAUTOCONNING
1--4
4093DOC000002 Edition: 29.MAR.2011
1.2 Construction
(see Figure: 1--1)
NAUTOCONNING is constructed modularly and can be adapted to the particular
tasks of different types of vessels.
This applies to interfaces to other equipment, sensors and to screen displays.
NAUTOCONNING basically consists of
Computer (see attached description no. 4090)
Navigation Data Manager (see attached description no. 3884)
Conning Display (see attached description 4094)
The NAUTOCONNING--,ECDIS-- and RADAR--Application can be used in one
console o r computer. These option is called M ultifunction Console M FC.
As an option an Alarm Transfer System can be added (see attached description
no. 4095).
An Alarmmanager enables NAUTOCONNING to integrate an Watch Alarm
System with Alarm Transfer System and Central Alarm Panel acc. to DNV.
The Ethernet Switch is used as Data Distribution for the NAUTOCONNING
Ethernet System.
Raytheon Anschütz GmbH
Germany
R
NAUTOCONNING
1--5
4093DOC000002Edition: 29.MAR.201 1
NMEA SENSORS
ALARM TRANSFER
SYSTEM
ECDIS RADAR
ETHERNET
SWITCH
NAUTOCONNING
DISPLAY
ALARM PANEL
used as CENTRAL
ALARM PANEL
CENTRAL BRIDGE PLACE
NAVIGATION DATA MANAGER
RADAR
ECDIS
AUTOPILOT
GYRO COMPASS
CONNING ALARM
NMEA
GL ONASS
WIND
GPS 1
GPS 2
ALARM SOURCES
NAVIGATIONAL
SOURCES (e.g.)
ECHOSOUNDER
GYRO
LOG
IR--NAV
IR--TRACK
AUTOPILOT NP20xx
AIS
FC--NAV
FC--TRACK
VDR
ANALOG
CONVERTER
Computer
MFC *)
*) Multifunction Console
or
ALARM
PANEL
Figure: 1--1 NAUTOCONNING SYSTEM (Overview)
NAUTOCONNING
1--6
4093DOC000002 Edition: 29.MAR.2011
/