Riva RC2102HD-5511 is a Full HD fisheye IP camera with a 1/2.7” 1080p CMOS Image Sensor and 180˚ wide and 160˚ vertical angle. It supports dual streaming mode, video motion detection, two-way mono audio, MicroSD card, PoE, and built-in Video Content Analysis. Remote Zoom/Focus Control and One Click AF make installation and operation easy.

Riva RC2102HD-5511 is a Full HD fisheye IP camera with a 1/2.7” 1080p CMOS Image Sensor and 180˚ wide and 160˚ vertical angle. It supports dual streaming mode, video motion detection, two-way mono audio, MicroSD card, PoE, and built-in Video Content Analysis. Remote Zoom/Focus Control and One Click AF make installation and operation easy.

1
www.rivatech.de
RC2102HD-5511
Installation
2
01A.03
www.rivatech.de
INFORMATION TO USER
CAUTION
RISK OF ELECTRIC SHOCK,
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
CONTACT QUALIFIED SERVICE PERSONNEL FOR INTERNAL
PARTS.
This symbol is intended to alert the user the presence of un-
insulated “dangerous voltage” within the product’s enclosure,
which may be sufficient magnitude to constitute a electric shock
risk to persons.
This symbol is intended to alert the user the presence of
important operating and maintenance (servicing) instructions
within the guide manual.
3
01A.03
www.rivatech.de
Table of Contents
1. FEATURES ................................................................................ 4
2. PACKAGE CONTENTS ................................................................. 5
3. PART NAMES ........................................................................... 6
4. INSTALLATION .......................................................................... 8
4.1. Option A. Semi-Flush Mount ............................................................ 8
4.2. Option B. Flush Mount ................................................................. 10
4.3. Setting the Image Attribute ........................................................... 12
5. CONNECTIONS ........................................................................ 13
6. CONFIGURATION...................................................................... 16
6.1.Set up network environment .......................................................... 16
6.1.1. Generic IP Environment .......................................................... 16
6.1.2. Custom IP Environment .......................................................... 17
6.2. View video on web page ............................................................... 18
6.2.1. View video using IPAdmin Tool ................................................. 20
6.3. Reset ........................................................................................ 21
6.4. Factory Default ........................................................................... 21
APPENDIX (A): SPECIFICATIONS ..................................................... 22
Summary .......................................................................................... 22
Environment Condition ........................................................................ 23
Mechanical Condition .......................................................................... 23
APPENDIX (B): POWER OVER ETHERNET ......................................... 24
PoE compatibility ................................................................................ 24
Power classification ............................................................................ 24
APPENDIX (C): DIMENSIONS .......................................................... 25
APPENDIX (D): HEXADECIMAL-DECIMAL CONVERSION TABLE ............. 26
REVISION HISTORY ....................................................................... 27
4
www.rivatech.de
1.FEATURES
Camera
Full HD indoor fisheye IP camera (Vandal proof)
High quality compression in real time streaming
1/2.7” 1080p CMOS Image Sensor
180˚ wide and 160˚ vertical angle
Remote Zoom/Focus Control(One Click AF)
Streaming
Dual streaming mode (such as different codec/resolution/bit rate and so
on.)
*
Burnt-in text supported
Unicast/Multicast supported
Video/Audio
Video compression: H.264/MJPEG, up to 30FPS@1080p*
Audio compression: G.711(µLaw, aLaw)/PCM
Analog video out (for installation only)
Video motion detection supported
Two-way mono audio supported
Network
RTSP/ HTTP protocol supported
10/100 Base-T Ethernet
Additional Features
Micro SD card support
PoE support
Built-in Video Content Analysis
SDK (Software Development Kit) provided
* When VCA is activated, frame rate is limit to max15fps@1080p. Limitations are
based on V.1.5.0 firmware release and could be changed without notice.
5
www.rivatech.de
2. PACKAGE CONTENTS
Unpack carefully and handle the equipment with care. The packaging contains:
Camera
DC power adapter
Quick installation guide
9-pin and 2-pin terminal blocks
FMB mount (for flush mount)
Screws and anchors
The above contents are subject to change without prior notice.
Note
i
6
www.rivatech.de
3. PART NAMES
1. Reset button
The reset button can be used for restarting the device or resetting it to Factory
Default.
2. PAL/NTSC button
Pressing the button cycles through PAL, NTSC, and no video output mode:
No video
output -> PAL->NTSC
. Please note that the analog video signal is only 3 minutes
present and go back automatically to none video output mode (only installation
process).
3. Video, Audio, and IO terminal connector
Connector for cable connection of audio input/output and digital input/output. Refer
to section.
* Models and their appearance are subject to change without any prior
notice.
*This button is located under
PCB.
7
www.rivatech.de
5. Connections
for more details. Video out is used only for installation and works for
3 minutes when PAL/NTSC button is pushed.
4. LAN connector
RJ45 LAN connector for 10/100 Base-T Ethernet.
5. MicroSD Slot
Slot for the MicroSD card
6. Power Adapter Connector
DC 12V adapter for power supply.
8
www.rivatech.de
4. INSTALLATION
4.1. Option A. Semi-Flush Mount
Installation template image’s size scale in this installation guide is
not 1:1.
The correct-size template design paper can be found inside the
package separately.
Caution
!
9
www.rivatech.de
1) Place the installation template
on a surface where camera is
going to be installed and mark
the anchor block placements.
2) Drill and insert anchor blocks on
a marked surface.
3) Mount the main camera body by
aligning the anchor blocks and hold
against the mounting surface..
4) Tighten the anchor blocks with
screws
5) Connect all the appropriate
cables to the device
6) Attach the dome cover on main
body and lock it up by rotating.
When placing the dome cover, look for carved triangle mark on
both dome cover and main body. Both triangles should be aligned
together when placing the cover. Once the cover has been placed,
rotate the dome cover for a secure lock. To detach the cover,
rotate the dome cover and align two triangle marks, and pull the
cover.
To prevent products from damaging, place the camera on stable
and non-vibrating surfaces. If the stability is in doubt, consult with
safety personnel for reinforcements, and then proceed with the
installation.
Caution
!
Caution
!
10
www.rivatech.de
4.2. Option B. Flush Mount
Installation template image’s size scale in this installation guide is
not 1:1.
The correct-size template design paper can be found inside the
package separately.
Caution
!
Installation template (FMB)
21 V1.0
11
www.rivatech.de
1) Trace the size on a surface
where the device will be inserted
with the provided template and
create a hole. Also, mark on a
surface where anchor blocks will
be inserted.
2) Drill and insert anchor blocks on a
marked surface.
3) Connect all the appropriate
cables to the main device and
place on the center of the hole.
Cables should be wired from other
side of the exposed surface.
4) Unscrew 3 bolts that are on the
dome cover’s surface and place the
FMB mount in between the top dome
shelf and bottom circular cylinder.
Align to the screws holes and re-tight
3 components with bolts.
5) Attach the dome cover on main
body from the surface side where it
will be exposed and lock it up by
rotating the cover.
6) Tighten the mounted surface’s
anchor blocks with screws on a FMB
mount parts..
When placing the dome cover, look for carved triangle mark on both
dome cover and main body. Both triangles should be aligned
together when placing the cover. Once the cover has been placed,
rotate the dome cover for a secure lock. To detach the cover,
rotate the dome cover and align two triangle marks, and pull the
cover.
Caution
!
12
www.rivatech.de
To prevent products from damaging, place the camera on stable
and non-vibrating surfaces. If the stability is in doubt, consult with
safety personnel for reinforcements, and then proceed with the
installation.
4.3. Setting the Image Attribute
Through the camera’s webpage, users can configure image settings.
The camera image’s brightness, contrast, saturation and sharpness are adjustable
through the image settings. (Setup > Video & Audio > Camera).
Caution
!
13
www.rivatech.de
5. CONNECTIONS
1. Audio input/output
The camera has a mono audio input and a mono audio output. Due to low audio output
power, an amplified speaker is recommended for enhanced sound (Do not connect a
headphone or earphone directly to the camera).
2. Sensor (DI) connection
The camera provides 1 channel D/I. It can be connected to either a voltage type
sensor or a relay type sensor as the following figures. Settings can be done through
the camera’s webpage
Input voltage range: 0VDC minimum to 5VDC maximum, Max 50mA
Input voltage threshold: 1.5V
Mic
Amp Speaker
ETHERNET
MICRO SD
DC12V
DO
DI
1
OutOut
1
VIDEO
C C
In
AUDIO
+
Reset
SW1 SW2 SW3
SW5 SW6
N / A N / A
N / A N / A
SW1
SW2
SW3
SW4
SW5
SW6
ETHERNET
MICRO SD
DC12V
DO
DI
1
OutOut
1
VIDEO
C C
In
AUDIO
+
Reset
SW1 SW2 SW3
SW5 SW6
N / A N / A
N / A N / A
SW1
SW2
SW3
SW4
SW5
SW6
14
www.rivatech.de
Do not exceed the maximum input voltage or relay rate.
3. Alarm (DO) connection
Only the relay type is supported.
Relay Rating: Max 24VDC 50mA
Do not exceed the maximum relay rating.
Must connect GND port which is located between systems.
Caution
!
Caution
!
Caution
!
DO
COM
Relay Type
Device
Internal
+3.3V
DI
COM
DI
COM
+
-
Relay Type
Voltage Type
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
15
www.rivatech.de
4. Video input/output
The camera provides 1 video out
5. LAN connection
This is a RJ45 LAN connector for 10/100 Base-T Ethernet. Connect a LAN cable.
When the device is connected, the orange LED stays on while green LED continues to
blink.
6. 12V DC Power
A 12 DC power connector is required for this device.
12V
Red
Black
Green LED Orange LED
Video
GND
Red
Black
16
www.rivatech.de
6.CONFIGURATION
6.1.Set up network environment
The default IP address of the device is 192.168.XXX.XXX. Users can identify the IP
address of the device from converting the MAC address’s hexadecimal numbers, which
is attached to the device. Be sure that the device and PC are on a same area network
before running the installation.
IP address : 192.168.xxx.xxx
Subnet mask: 255.255.0.0
6.1.1. Generic IP Environment
In case of generic private network environment where IP address 192.168.XXX.XXX
are used, users may view the live streaming images on a web page using the device’s
default IP address:
1. Convert the device’s MAC address to the IP address. Refer to the Hexadecimal-
Decimal Conversion Chart at the end of the manual.
(The MAC address of the device is attached on the side or bottom of the device.)
2. Start the Microsoft® Internet Explorer web browser and enter the address of the
device.
3. Web streaming and device configurations are supported through ActiveX program.
When the ActiveX installation window appears, authorize and install the ActiveX.
MAC address = 00-13-23-01-14-B1 IP address = 192.168.20.177
Convert the last two set of hexadecimal numbers to decimal numbers.
17
www.rivatech.de
6.1.2. Custom IP Environment
IPAdminTool and the manual are provided on USB stick or can download from
www.rivatech.de homepage.
IPAdminTool is a management tool, which automatically scans all of the network
products for users to perform administrative tasks, which includes network
configurations, firmware update, device reboot, and device organizations.
To modify the device’s default IP address for customized network area;
1. Find the device from the IPAdminTool’s list and highlight the device’s name.
2. Right-click the mouse and select “IP Address”; IP Setup window appears.
PC environment Info
Give new unique IP address in
last two sets and mirror other
information in other boxes
18
www.rivatech.de
3. In the IP Setup’s window, information under ‘Local Network information’ displays the
user/PC’s network area information. Those information need to be incorporated to
the IP Address, Subnet Mask, Gateway, and DNS boxes, except the last 2 sets of
IP Address, which are to be the unique numbers for the device. Refer to the image
above for the setting
4. Click ‘Setup’ to complete the modification. When the dialog box appears to request
user name and password, enter the default value for the administrator account
(case-sensitive) as below:
ID:
root
Password:
pass
6.2. View video on web page
Type the proper IP address to view the live streaming images through a web browser.
The default username and password is
root / pass
.
1. The browser asks to install the ActiveX. Click Allow.
2. Setup.exe installation link or pop-up window appears, depends on Microsoft®
Internet Explorer version. Proceed with rest of setup installation.
19
www.rivatech.de
Caution
!
3. Follow the instructions of the dialog boxes and complete the installation. Once the
installation is complete, start the web browser again and check if video stream is
displayed in the main view frame.
If
This software requires the Microsoft XML Parser V6 or higher.
Please download MSXML6 from the Microsoft website to continue.
Error code: Cannot create XMLDOMDocument.
message appears,
download and install the Microsoft Core XML Services (MSXML)
6.0.
20
www.rivatech.de
Caution
!
6.2.1. View video using IPAdmin Tool
IPAdminTool automatically searches all activated network encoders and IP cameras
and shows the product name, IP address, MAC address and etc. IPAdminTool is
provided on USB stick or can download from www.rivatech.de homepage.
1. From the IPAdminTool’s product list, select the device by highlighting it.
2. Right-click the mouse and select Web view
3. The system’s default web browser opens the device’s address. Please take care
that the default system web browser is Microsoft® Internet Explorer to support
ActiveX plug-in.
Whether directly accessing the streaming video through typing IP
address on a web page or taking steps through IPAdminTool, the
ActiveX is needed to be installed for the Microsoft® Internet
Explorer to have the complete configuration privileges.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Riva RC2102HD-5511 Installation guide

Category
Security cameras
Type
Installation guide

Riva RC2102HD-5511 is a Full HD fisheye IP camera with a 1/2.7” 1080p CMOS Image Sensor and 180˚ wide and 160˚ vertical angle. It supports dual streaming mode, video motion detection, two-way mono audio, MicroSD card, PoE, and built-in Video Content Analysis. Remote Zoom/Focus Control and One Click AF make installation and operation easy.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI