Real Fyre G31 Owner's manual

Category
Fireplaces
Type
Owner's manual

This manual is also suitable for

1
REV 6 - 1703211515
L-A2-353
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
The Real Fyre burner system is to be installed only in
a solid-fuel burning fi replace with a working fl ue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure
of the damper blade. The chimney damper MUST
be fully opened when burning the unit. The unit is
designed to burn with yellow fl ames; thus adequate
ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this burner system, use ONLY Peterson
parts and accessories. Use of other controls, parts,
and accessories that are not designed for use with
Real Fyre burner systems is prohibited and will void
all warranties, certifi cations, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life. Peterson will not be liable for any
damages caused by this misuse.
*Note: Solid-fuels shall not be burned in a fi replace
where a decorative appliance is installed.
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE UNIT.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use with the type
of gas indicated on the rating plate.
Installation and service must be performed
by a qualified professional installer,
service agency, or the gas supplier.
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60-2012
CSA 2.26-2012
12-086
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
G31 TRIPLE BURNER VENTED SYSTEMS
Regulated burner
system for use with
propane or natural gas
INSTALLATION &
OWNER’S MANUAL
Burner Systems:
G31- ** -(P)A
G31- ** -17(P)
G31- ** -2V(P)T
G31- ** -02(P)
** Sizes:
(18/20, 24/30, 33/39)
3
REV 6 - 1703211515
L-A2-353
TABLE OF CONTENTS
GETTING STARTED
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION ...........................................5
FIREPLACE OPERATING SAFETY INFORMATION .......................................................................................7
SPECIFICATIONS............................................................................................................................................8
DAMPER CLAMP INSTRUCTIONS ............................................................................................................. 10
BURNER PARTS LIST - MANUAL PILOT (A) SERIES ..................................................................................11
BURNER PARTS LIST - 17 SERIES .............................................................................................................. 12
BURNER PARTS LIST - 2VT SERIES ........................................................................................................... 13
BURNER PARTS LIST - 02 SERIES .............................................................................................................. 14
LOGS PARTS LIST ....................................................................................................................................... 15
INSTALLATION
INSTALLATION ........................................................................................................................................... 17
BURNER INSTALLATION .......................................................................................................................... 17
LIGHTING TEST ...................................................................................................................................... 18
LOG SET AND EMBERS PLACEMENT [MC(O,S) log sets] .............................................................................. 19
INSTALLING/REPLACING BATTERIES (if applicable) ................................................................................. 22
REMOTE TRANSMITTER BATTERY ............................................................................................................ 22
RECEIVER/SWITCH BOX BATTERIES ......................................................................................................... 22
USE, CARE, & SERVICE
LIGHTING INSTRUCTIONS - MANUAL PILOT (A) SERIES ....................................................................... 23
FOR YOUR SAFETY, READ BEFORE LIGHTING .......................................................................................... 23
LIGHTING THE PILOT ............................................................................................................................. 23
LIGHTING THE BURNER ......................................................................................................................... 25
SHUTTING DOWN ................................................................................................................................... 25
PILOT BURNER CHECK/ADJUSTMENT ..................................................................................................... 25
LIGHTING INSTRUCTIONS - 17 SERIES ..................................................................................................... 27
FOR YOUR SAFETY, READ BEFORE LIGHTING .......................................................................................... 27
LIGHTING THE PILOT ............................................................................................................................. 27
REMOTE LIGHTING ................................................................................................................................ 27
MANUAL LIGHTING ................................................................................................................................ 29
SHUTTING DOWN ................................................................................................................................... 31
PILOT BURNER CHECK/ADJUSTMENT ..................................................................................................... 31
REMOTE OPERATING INSTRUCTIONS - 17 SERIES .................................................................................. 31
ORIENTATION ........................................................................................................................................ 31
FLAME HEIGHT ..................................................................................................................................... 31
LIGHTING INSTRUCTIONS - 2VT SERIES .................................................................................................. 33
FOR YOUR SAFETY, READ BEFORE LIGHTING .......................................................................................... 33
REMOTE LIGHTING ................................................................................................................................ 33
MANUAL LIGHTING ................................................................................................................................ 35
SHUTTING DOWN ................................................................................................................................... 35
PILOT APPEARANCE ............................................................................................................................... 35
REMOTE OPERATING INSTRUCTIONS - 2VT SERIES ............................................................................... 37
ORIENTATION ........................................................................................................................................ 37
FLAME HEIGHT ..................................................................................................................................... 37
LIGHTING INSTRUCTIONS - 02 SERIES ..................................................................................................... 39
FOR YOUR SAFETY, READ BEFORE LIGHTING .......................................................................................... 39
REMOTE LIGHTING ................................................................................................................................ 39
MANUAL LIGHTING ................................................................................................................................ 41
SHUTTING DOWN ................................................................................................................................... 41
PILOT APPEARANCE ............................................................................................................................... 41
CLEANING AND SERVICING ...................................................................................................................... 43
SYNCING THE REMOTE SYSTEM (if applicable) ........................................................................................... 44
FLAME DESCRIPTION ................................................................................................................................ 44
TROUBLESHOOTING .................................................................................................................................. 45
ELECTRONIC PILOT TROUBLESHOOTING (IF APPLICABLE) .................................................................. 47
WARRANTY ................................................................................................................................................ 48
5
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION
A. BE CAREFUL: If not installed, serviced, and used correctly per these instructions, this product can cause serious
personal injury, property damage, or loss of life.
B. WARNING: Before installing in a solid-fuel-burning fi replace, the chimney fl ue, damper, and fi rebox must be thoroughly
CLEANED of soot, creosote, ashes, and loose paint, and must be inspected by a qualifi ed chimney cleaner. Some older
replaces may need repair prior to installing this appliance.
C. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is NOT FIELD CONVERTIBLE
for use with other gasses.
CHECK GAS TYPE (natural or L.P.): The gas supply must be the same as stated on your burner system rating plate. If
gas supply is different, DO NOT INSTALL. Contact your dealer for immediate assistance.
D. INSUFFICIENT GAS PRESSURE WILL KEEP THE PILOT (IF EQUIPPED) FROM OPERATING PROPERLY.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT.
E. The minimum inlet gas-supply pressure for purposes of input adjustment is 5" water column (w.c.) on natural gas and
11" w.c. on L.P. gas. Insuffi cient gas pressure will affect proper operation of the pilot (if equipped). Do not install this gas
appliance if minimum pressure is not available. The maximum inlet gas-supply pressure is 10.5" w.c. on natural gas and
13" w.c. on L.P. gas. The L.P. source must be regulated. (Do not connect this appliance directly to an unregulated
L.P. gas tank - this can cause an explosion.) Do not connect this appliance to a portable L.P. gas cylinder.
F. The gas piping system must be sized to provide minimum inlet pressure at the maximum fl ow rate (BTU/hr).
Undue pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be
1
/
2
" minimum
interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary. Refer to the NFPA 54
guidelines for further details.
G. Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the National
Fuel Gas Code or contact manufacturer before installing this product.
H. This gas appliance and its main gas valve must be disconnected from the gas-supply piping system during any pressure
testing of that system at test pressures in excess of
1
/
2
psig.
I. This gas appliance must be isolated from the gas-supply piping system by closing the equipment shutoff valve connected to
the gas-supply line during any pressure testing of the gas-supply piping system at test pressures equal to or less than
1
/
2
psig.
J. To install the gas appliance in your fi replace, the fi replace MUST meet the minimum size requirements (see
product specifi cations table in SPECIFICATIONS section).
K. This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited
by local codes. Installation of appliances designed for manufactured home (U.S. only) or mobile home installation must
conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/
NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
L. DO NOT install this burner system if the fi replace hearth is recessed. The replace oor must be at the same level
as or higher than the fi replace front opening. If glass doors are used: the fi replace oor must not be blocked by the door
frame; the frame must have openings to allow for fresh air circulation. See the SPECIFICATIONS section for details.
CAUTION: Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional installer.
Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand
all safety precautions and warnings contained in this manual.
7
FIREPLACE OPERATING SAFETY INFORMATION
A. Adults shall be present when this gas appliance is operating. This unit shall not be left burning when unattended or
while anyone is sleeping.
B. Keep the area of the gas burner system clear and free from combustible materials, gasoline, and other fl ammable
vapors and liquids.
C. DO NOT use this appliance if any part has been underwater. Immediately call a qualifi ed service technician to inspect
the appliance and to replace any part of the control system and any gas control that has been underwater. Attempted
operation may result in fi re or explosion resulting in property damage, personal injury or loss of life.
D. A replace screen must be in place when the system is burning. Provisions for adequate combustion air must be
maintained. Unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction
of combustion air. Combustion air is adequate when all fl ames curl into the fi replace and away from the screen. When
a glass fi replace enclosure (door) is used, leave the doors fully open when the system is in operation.
E. Do not remove the rating plates or the warning tags. These are an integral safety and identifi cation component of this
appliance.
F. Be sure to read the CLEANING AND SERVICING and FLAME DESCRIPTION sections.
8
Real Fyre gas burner systems must be installed only in a wood burning fi replace with the minimum
rebox dimensions and venting requirements met (see table on this page). This appliance is designed
to burn with yellow fl ames; adequate ventilation is absolutely necessary.
SPECIFICATIONS
Table 1 - Product Specifi cations
Fireplace Floor Requirement
DO NOT install this burner system if the fi replace hearth is recessed. The fi replace fl oor must be at
the same level as or larger than the fi replace front opening. An ash lip or recess may not exceed
3
/
4
". See
Fig. 8-1 below.
Note: If glass doors are used: the fi replace fl oor must not be blocked by the door frame; the frame must
have openings to allow for fresh air circulation.
Product Specifi cations
Fig. 8-1
Fireplace
oor
Fireplace
opening
(burner
system)
ASH LIP OR
RECESS
ABOVE
3
/4"
NOT
PERMITTED
Max.
3
/4
"
ASH LIP OR
RECESS UP
TO
3
/4"
PERMITTED,
Specifi cation Value Qty.
02 burner system battery type D battery 2
2VT burner system battery type AA battery 4
Remote transmitter battery type 12V battery 1
Remote receiver battery type AA battery 4
Table 2 - Technical Data (if applicable)
Burner
Model
Dimensions BTU Rating
Width *
Depth Height
Nat. Gas L.P. Gas
Front Rear
High
Setting
Low
Setting †
High
Setting
Low
Setting †
G31-18/20 (18" log set) 25" 20" 15" 16" 55k 20k 40k 21k
G31-24/30 (24" log set) 35" 25" 15" 16" 65k 21k 50k 22k
G31-24/30 (30" log set) 39" 28" 15" 16" 65k 21k 50k 22k
G31-33/39 (33" log set) 44" 32" 15" 16" 75k
/ 85k 22k 60k 23k
G31-33/39 (39" log set) 47" 32" 15" 16" 75k
/ 85k 22k 60k 23k
* For 02 models, add 2" to both front and rear width
† 2VT models only
Note: Rear width is at corresponding depth.
9
SPECIFICATIONS (cont.)
17 SERIES WIRING DIAGRAM
Fig. 9-1
Remote
receiver
Inlet
Valve
Outlet
02 SERIES WIRING DIAGRAM
Fig. 9-2
Remote
receiver
Valve
Ignition
module
Wire
harness
Battery
box
Ground
wire
2VT SERIES WIRING DIAGRAM
Valve
Motor wire
harness
Battery
pack
Ignition
module
Fig. 9-3
Insulated copper
Black
S
I
Main wire
harness
White
Green
Orange
Red
Black
Main
Gas
inlet
Step motor
main fl ame
(Main gas out)
(Pilot gas out)
Main fl ame
step output
Copper
Black
(GND)
Thermocouple
line
Pilot
Pilot
assembly
Pilot
assembly
Pilot
assembly
Electrode
wires
Wire
harness
10
Damper clamp
Set screw
Open
Closed
DAMPER CLAMP INSTRUCTIONS
Fig. 10-1 Damper clamp detail
Fig. 10-2 Damper open / closed
The damper clamp with hex bolt (
Fig. 10-1) is provided as a
means to prevent full closure of the damper blade. The clamp is
easily attached to most damper blades with pliers or a wrench,
and must be permanently installed. The clamp is designed
to prevent accidental closure of the damper when installed
as illustrated (Fig. 10-2). Should the clamp not fi t, or fail to
provide the permanent vent opening listed in Table 3 below,
have a permanent stop installed, remove the damper blade,
or have the damper cut to provide the minimum permanent
opening required.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fi replaces
Chimney height 18/20" 24/30" 33/39"
15' 24 30 42
20' 20 25 35
30' 16 19 27
For masonry-built fi replaces
15' 35 41 52
20' 32 37 47
30' 29 34 43
Note: The minimum chimney height from hearth to top of chimney is 15'.
Table 3 - Minimum Chimney Damper Venting Requirements
Venting Requirements
THE DAMPER MUST BE COMPLETELY OPENED WHEN OPERATING THIS GAS APPLIANCE TO
ACHIEVE THE BEST VENTILATION POSSIBLE.
THESE ARE MINIMUM DAMPER OPENING SPECIFICATIONS.
11
BURNER PARTS LIST - MANUAL PILOT (A) SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24/30" burner model shown
Bottom view
9
3
2
1
4
8
Pilot
5
Thermocouple
6
7
18/20" model 24/30" model 33/39" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane models) SV-19 1 SV-19 1 SV-19 1
3.
Valve extension kit
(includes extension rod, knob, bracket, and nut)
EH-12 1 EH-12 1 EH-12 1
4. Flex connector (w/ adapter), 1/2" O.D. x 24" CK-5-24SP 1 CK-5-24SP 1 CK-5-24SP 1
5. Lava fyre coals LFC-6 1 LFC-6 1 LFC-6 1
6. Lava granules LF-5 1 LF-5 1 LF-5 1
7. Glowing embers EM-21B 1 EM-21B 2 EM-21B 3
8. Bryte coals EM-11 1 EM-11 1 EM-11 2
9. Damper clamp DC-1 1 DC-1 1 DC-1 1
Flash tube
12
BURNER PARTS LIST - 17 SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
Bottom view
12
5
3
2
1
7
11
Pilot
8
Thermocouple
9
10
4
Remote transmitter and receiver
batteries included with burner system.
18/20" model 24/30" model 33/39" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane models) SV-37 1 SV-37 1 SV-37 1
3.
Valve extension kit
(includes extension rod, knob, bracket, and nut)
EH-12 1 EH-12 1 EH-12 1
4.
Remote kit
(includes receiver, transmitter, batteries,
and plastic cover)
VR-1A 1 VR-1A 1 VR-1A 1
5. Remote transmitter (only) AT-V1-1 1 AT-V1-1 1 AT-V1-1 1
6. Decorative heat shield HS-36 1 HS-36 1 HS-36 1
7. Flex connector (w/ adapter), 1/2" O.D. x 24" CK-5-24SP 1 CK-5-24SP 1 CK-5-24SP 1
8. Lava fyre coals LFC-6 1 LFC-6 1 LFC-6 1
9. Lava granules LF-5 1 LF-5 1 LF-5 1
10. Glowing embers EM-21B 1 EM-21B 2 EM-21B 3
11. Bryte coals EM-11 1 EM-11 1 EM-11 2
12. Damper clamp DC-1 1 DC-1 1 DC-1 1
24/30" burner model shown
6
Flash tube
13
BURNER PARTS LIST - 2VT SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
Bottom view
18/20" model 24/30" model 33/39" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-12
PAC-12P
1
1
PAC-12
PAC-12P
1
1
PAC-12
PAC-12P
1
1
2.
or
Control valve (natural)
Control valve (propane)
SV-47
SV-47P
1
1
SV-47
SV-47P
1
1
SV-47
SV-47P
1
1
3. Control module / remote receiver IMP-6 1 IMP-6 1 IMP-6 1
4. Main & motor harness assembly WH-02 1 WH-02 1 WH-02 1
5. Battery box BAT-02 1 BAT-02 1 BAT-02 1
6.
Switch box assembly
(includes battery box, switch, heat shield)
SBA-02 1 SBA-02 1 SBA-02 1
7. Decorative heat shield HS-42 1 HS-42 1 HS-42 1
8. Flex connector (w/ adapter), 1/2" O.D. x 24" CK-5-24SP 1 CK-5-24SP 1 CK-5-24SP 1
9. Remote transmitter (only) AT-2VA-1 1 AT-2VA-1 1 AT-2VA-1 1
10. Lava fyre coals LFC-6 1 LFC-6 1 LFC-6 1
11. Lava granules LF-5 1 LF-5 1 LF-5 1
12. Glowing embers EM-21B 1 EM-21B 2 EM-21B 3
13. Bryte coals EM-11 1 EM-11 1 EM-11 2
14. Damper clamp DC-1 1 DC-1 1 DC-1 1
14
9
6
2
3
Pilot
1
7
13
Electrode
10
4
Thermocouple
11
12
5
Remote transmitter and switch box
batteries included with burner system.
24/30" burner model shown
8
Flash tube
14
BURNER PARTS LIST - 02 SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
Bottom view
18/20" model 24/30" model 33/39" model
Item Description Part No. Qty. Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
2.
or
Control valve (natural)
Control valve (propane)
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
3. Control module IMP-1 1 IMP-1 1 IMP-1 1
4. Main harness assembly WH-03 1 WH-03 1 WH-03 1
5.
Remote receiver box
(includes remote receiver, battery box, metal heat
shield assy, wire harness)
AR-02-1 1 AR-02-1 1 AR-02-1 1
6. Remote transmitter (only) AT-R1-1 1 AT-R1-1 1 AT-R1-1 1
7. Decorative heat shield HS-37 1 HS-37 1 HS-37 1
8. Flex connector (w/ adapter), 1/2" O.D. x 24" CK-5-24SP 1 CK-5-24SP 1 CK-5-24SP 1
9. Lava fyre coals LFC-6 1 LFC-6 1 LFC-6 1
10. Lava granules LF-5 1 LF-5 1 LF-5 1
11. Glowing embers EM-21B 1 EM-21B 2 EM-21B 3
12. Bryte coals EM-11 1 EM-11 1 EM-11 2
13. Damper clamp DC-1 1 DC-1 1 DC-1 1
13
6
3
2
Pilot
1
8
12
Electrode
9
4
Flame sensor
10
11
5
Remote transmitter and switch box
batteries included with burner system.
24/30" burner model shown
1
1
Re
mo
te
t
ra
ns
batteries incl
u
7
Flash tube
15
MC(O,S)-18 Log Sets
Mountain Crest Oak (MCO) Mountain Crest Split (MCS)
Item Description Part No. Qty. Part No. Qty.
1. Rear log MCOL-16BR 1 MCOL-16BR 1
2. Front log MCOL-18BF 1 MCSL-18BF 1
3. Center middle log MCOL-14TC 1 MCSL-14TC 1
4. Left top log MCOL-10TL 1 MCSL-10TL 1
5. Right top log MCOL-12TR 1 MCSL-12TR 1
6. Center top log MCOL-9T 1 MCSL-9T 1
LOGS PARTS LIST
2
1
3
4
5
6
MCO-18
Log Set Shown
MC(O,S)-(24,30) Log Sets
Mountain Crest Oak (MCO) Mountain Crest Split (MCS)
Item Description Part No. Qty. Part No. Qty.
1.
or
24" Rear log
30" Rear log
MCOL-20BR
MCOL-24BR
1
1
MCOL-20BR
MCOL-24BR
1
1
2.
or
24" Front log
30" Front log
MCOL-24BF
MCOL-30BF
1
1
MCSL-24BF
MCSL-30BF
1
1
3. Center middle log MCOL-14TC 1 MCSL-14TC 1
4. Left top log MCOL-11TL 1 MCSL-11TL 1
5. Right top log MCOL-15TR 1 MCSL-15TR 1
6. Center top log MCOL-10T 1 MCSL-10T 1
MCOL 1
1
MC
2
1
3
4
5
6
MCO-24
Log Set Shown
MC(O,S) log sets are designed exclusively for placement on G31 burner systems and are addressed in
this manual.
Additional common log sets are available: CHB, CHD, CHAO, CHS, CHNA, CHNS series.
If a common log set is purchased, follow the G31 supplemental instructions supplied with this burner
system. (Disregard the common log placement instructions packed with the log set.)
16
LOGS PARTS LIST (cont.)
Note: The log set is purchased and packaged separately.
2
1
4
3
5
6
MCO-33
Log Set Shown
MC(O,S)-(33,39) Log Sets
Mountain Crest Oak (MCO) Mountain Crest Split (MCS)
Item Description Part No. Qty. Part No. Qty.
1. Rear log MCOL-28BR 1 MCOL-28BR 1
2.
or
33" Front log
39" Front log
MCOL-33BF
MCOL-39BF
1
1
MCSL-33BF
MCSL-39BF
1
1
3. Left middle log MCOL-10T 1 MCSL-10T 1
4. Center middle log MCOL-15TY 1 MCSL-15TY 1
5. Right middle log MCOL-10TR 1 MCSL-10TR 1
6. Left top log MCOL-13T 1 MCSL-13T 1
7. Center top log MCOL-11TL 1 MCSL-11TL 1
8. Right top log MCOL-15T 1 MCSL-15T 1
8
7
17
REFER TO THE PARTS LIST WHEN FOLLOWING THESE
INSTRUCTIONS.
24" 02 burner model shown here.
BURNER INSTALLATION
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF.
2. Locate the gas-supply stub inside the fi replace and remove the
cap, if attached (reference Fig. 17-1).
CAUTION: When removing the cap, make sure the stub does not
turn, loosening the connection inside the wall.
3. Place the burner system in the fi replace. Center the burner from
left to right in the fi replace. (Reference Fig. 17-2 for orientation.)
Note: Ensure the porcelainized panel is clean of all dust. Use a
clean soft cloth if necessary. See Fig. 17-3.
4. Be sure gas to the fi replace is off. Remove the adapter
connected to the fl ex connector (pre-installed on the burner
system). Attach the adapter to the gas-supply stub using a pipe
compound resistant to all gasses. Tighten securely. Then attach
the open end of the fl ex connector to the adapter. Tighten securely
(see Fig. 17-1).
5. LEAK TEST: Turn on the fi replace gas supply, and test at all
connections for leaks using the appropriate soapy water solution.
If bubbles appear, a leak is present. Turn off the gas and tighten
at all connections. Repeat until no leaks are present. If a leak
persists, turn off the gas supply and contact the local gas company
or dealer. NEVER USE A FLAME TO CHECK FOR LEAKS.
For manual pilot models, continue to the following section.
6. At this stage the burner system batteries are to be installed
(if applicable). Reference the INSTALLING/REPLACING
BATTERIES section for details.
7. Remote Receiver (17 models)
Place the plastic cover over the receiver. Then place on its side,
at the rear left corner of the fi replace. Place as far from the burner
system as possible. See Fig. 17-2 & Fig. 17-4.
Remote Receiver/Switch Box (02 & 2VT models)
Place on its side, at the rear left corner of the fi replace. It
should rest with its bottom as near as possible and facing the
replace wall. It must not be placed directly next to the burner
pan area to avoid damage to the batteries (and remote receiver
- 02 models). See Fig. 17-2 & Fig. 17-4.
Important: Ensure that the box wire remains away from the burner
system and its fl ame during operation.
The Real Fyre burner system must be installed by a qualifi ed professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefi t from the burner system. Check to be
sure the burner system is designed and labeled for the type of gas (natural or propane gas) supplied to
the fi replace. Fireplace fl oor must be level, clean, and smooth (see FIREPLACE SAFETY INFORMATION
section).
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifi cally approved with this appliance may result in property damage or personal injury.
INSTALLATION
Fig. 17-2 Place receiver/switch box
Fig. 17-1 Connect gas supply
Flex connector
Adapter
Gas supply stub
Fig. 17-3 Ensure a clean panel
Keep clean and DO NOT
cover with embers
(02 model shown here)
Fig. 17-4 Proper receiver/box placement
Place
receiver/switch box:
Rear left corner,
on side,
exposed side against
replace wall
DO NOT
place box
in this area
Place receiver or receiver/switch box
Place receiver:
Rear left corner
• Ensure plastic
cover is in place
18
IMPORTANT
For all valves, the air MUST be purged from the gas line before the pilot will light and burn properly. The time
needed to purge will depend on the length of the gas line to the unit and the amount of time since the unit or
gas line was last used. It may take several minutes before all the air is purged and the pilot will light and burn
properly. Reference the LIGHTING INSTRUCTIONS section in this manual.
INSTALLATION (cont.)
8. Decorative Heat Shield (remote models only)
Place the decorative heat shield over the remote receiver/
switch box as shown in Fig. 18-1.
LIGHTING TEST
Prior to proceeding with installation, perform a lighting test
(see lighting instructions for lighting your burner). Allow the
unit to completely cool after testing.
LAVA GRANULES/COALS (DECORATIVE)
1. Spread the supplied lava granules on the fl oor of the
replace, around the front and sides of the burner system
(see Fig. 18-2). The lava granules may be placed around
the receiver/switch box. Leave the front of the receiver/
switch box clear for control access.
2. Repeat this process for the supplied lava coals (on top of
the already placed lava granules).
Note: DO NOT place any lava media on the burner system,
or behind it.
Fig. 18-2 Place lava media
Fig. 18-1 Place heat shield (if applicable)
Must rest on fl oor and at rear corner
19
INSTALLATION (cont.)
CAUTION: BURN HAZARD! Logs will remain hot for some time after use. If you need to reposition
any log to maintain the proper layout, use heat-resistant gloves or allow logs adequate time
to cool before handling.
Place the rear log (log #1) as shown. The log should
rest fl at between the rear brackets and top burner.
1
Embers
1A
2
Place the remaining glowing embers evenly in the
area along the front log as shown.
Store any excess embers if applicable.
2A
Generic Placement Steps
Important: DO NOT place any embers on top of the fl ash tube to ensure proper operation.
All models begin with the log and ember placement shown below. Continue with the appropriate section (on one of the
following pages) specifi c to your log set size.
Embers
DO NOT place any embers on top of the fl ash tube
to ensure proper operation. Keep the area shown
above clear at all times.
Place the supplied glowing embers evenly in the
areas shown. Break up any clumps that may have
developed during shipment. Keep some embers
for future placement along the front log.
You must position and maintain the log layout as shown here to ensure optimal operation of the burner system.
24" log set shown below for generic placement steps. Final steps are separated by log set sizes. Do not add
any additional embers to this log set. Any additional embers may cause unsafe operation. MCO log sets
shown. Design may vary slightly; placement is the same.
LOG SET AND EMBERS PLACEMENT [MC(O,S) log sets]
Log placement shown here is for MC(O,S) log sets. If a different log set has been purchased, follow
the G31 supplemental instructions supplied with this burner system. (Disregard the common log
placement instructions packed with the log set.)
Keep fl ash
tube clear
(fl ash tube)
Place the front log (log #2) as shown. Rest the log
with its back against the burner assembly behind it.
DO NOT place it forward or on top of the grate
ngers.
1
(fl ash tube)
Ember placement detail.
Keep fl ash
tube clear
Embers
20
INSTALLATION (cont.)
4
5
6
18", 24" & 30" Log Sets Only
For 18", 24", & 30" log sets, continue with the steps below to complete placement.
For 33" & 39" log sets, proceed to the following page.
3
Bryte Coals
Separate half of the supplied bryte coals into small
pieces, and evenly place them over the glowing
embers in the middle ember bed as shown.
2B
Bryte Coals
Separate the remaining (second half) of bryte coals
into small pieces, and evenly place them over the
glowing embers in the bottom ember bed as shown.
2C
Place the center top log (log #6) as shown. It
will rest on the front log and in the groove of the
center log below.
Place the left and right top logs (logs #4 & #5) as
shown. They will rest in the grooves found on the
logs below.
Place the center middle log (log #3) as shown. It
will rest in the grooves found on the logs below.
Generic Placement Steps (cont.)
To complete log placement continue to the appropriate section specifi c to your log set size.
21
33" & 39" Log Sets Only
For 33" & 39" log sets, continue with the steps below to complete placement.
For 18", 24", & 30" log sets, go back to the previous page.
INSTALLATION (cont.)
6
5
Place the left and center middle logs (logs #3 & #4)
as shown. They will rest in the grooves found on the
logs below.
3
Place the right middle log (log #5) and the left top log
(log #6) as shown. They will rest in the grooves found
on the logs below.
8
4
7
Place the center and right top logs (logs #7 & #8) as
shown. They will rest in the grooves found on the logs
below.
22
INSTALLING/REPLACING BATTERIES (IF APPLICABLE)
CAUTION: Ensure the unit is connected to the gas line and has
been tested for leaks before you insert batteries.
CAUTION: Turn off the remote and/or burner and allow the unit
to completely cool prior to any battery replacements.
Important: Low/dead batteries will affect burner system
operation. Replace batteries any time the burner
will not turn on.
REMOTE TRANSMITTER BATTERY
The remote transmitter requires one 12V battery to operate (included).
Locate the transmitter, remove the lid (found on rear), and properly
insert the new battery as marked. Re-secure the lid. See Fig. 22-1.
RECEIVER/SWITCH BOX BATTERIES
Important: Always replace the decorative heat shield over
the receiver or receiver/switch box after battery
replacement.
Remote receiver
02 models
The remote receiver requires 4 AA batteries to operate (included).
Locate the remote receiver box and turn it over. Use a Phillips
screwdriver to remove the screw found on the side of the box, then
remove the bracket. Remove the receiver from the box and turn it
over. Slide open the lid, and properly insert the new batteries as
marked. See Fig. 22-2 (also reference Fig. 22-3).
Replace the lid and replace the remote receiver onto the Velcro in
the remote receiver box. Then replace the bracket using the screw
and re-position the box in the fi replace.
17 models
The remote receiver requires 4 AA batteries to operate (included).
Locate the remote receiver and turn it over. Slide open the lid, and
properly insert the new batteries as marked. See Fig. 22-2.
Replace the lid, then re-position the remote receiver in the fi replace.
(Ensure the plastic cover is properly in place over the receiver.)
Receiver/Switch Box
02 models
The burner system requires 2 D batteries to operate (included). Locate
the remote receiver box and turn it over. Use a Phillips screwdriver
to remove the screw found on the side of the box, then remove the
bracket. Properly insert the new batteries as marked. See Fig. 22-3.
Replace the bracket using the screw and re-position the remote
receiver box in the fi replace.
2VT models
The burner system requires 4 AA batteries to operate (included).
Locate the switch box and turn it over. Detach the battery box from
the Velcro. Use a small Phillips screwdriver to remove the screw
found on the bottom of the battery box, then remove the battery lid.
Properly insert the new batteries as marked. See Fig. 22-3.
Replace the battery lid using the screw, replace the battery box onto
the Velcro, and re-position the switch box in the fi replace.
Fig. 22-1 Transmitter battery
Remove
lid for
12V
battery
access
AA batteries
Fig. 22-2 Remote receiver batteries
(17 model shown)
AA batteries
Fig. 22-3 Receiver/switch box batteries
2VT model
02 model
D batteries
Brackets
Screws
Remote
receiver
23
PILOT
OFF
OFF
ON
PILOT
OFF
ON
PILOT
OFF
ON
PILOT
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
A. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it. Call a qualifi ed professional service technician. Excessive force or
attempted repair may result in fi re or explosion.
B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
Do not light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fi re department.
C. The burner system has a pilot that can be lit by hand using a long fi replace match or lighter. When lighting
the pilot, follow these instructions exactly.
D. Do not use this appliance if any part has been underwater. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
underwater. Attempted operation may result in fi re or explosion resulting in property damage, personal
injury or loss of life.
LIGHTING THE PILOT
1. Locate the valve on the side of the unit. Push in the
gas control knob slightly and turn clockwise to OFF
(Fig. 23-1).
Note: The control knob cannot be turned from PILOT
to OFF unless the knob is pushed in slightly. Do
not force.
Allow fi ve (5) minutes for any gas in the unit to dissipate.
IF YOU SMELL GAS, SEE STEP B ABOVE. If you don’t
smell gas, go on to step 2.
2. Turn the control knob counterclockwise to PILOT
(Fig. 23-1). Push the control knob rmly and fully
in and hold. Hold a long fi replace match or lighter
near the thermocouple to light the pilot. Continue to
hold the control knob in for approximately 60 seconds
after the pilot is lit, then release the knob. The pilot
will remain lit.
WARNING: If the pilot fails to light repeat steps 1
and 2.
If the pilot fails to light after several tries, turn the control
knob to OFF and contact a qualifi ed professional service
technician.
Fig. 23-1 Control knob detail (OFF, PILOT)
1. Turn knob
clockwise to OFF
prior to lighting
the pilot.
LIGHTING INSTRUCTIONS - MANUAL PILOT (A) SERIES
2. Turn knob
counterclockwise to
PILOT position. With
match ready, press
knob in and hold for
60 seconds while
lighting pilot.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Real Fyre G31 Owner's manual

Category
Fireplaces
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages