Lenovo THINKSERVER TD230 Software User's Manual

Category
RAID controllers
Type
Software User's Manual

This manual is also suitable for

ThinkServer RD230, RD240, and TD230
MegaRAID SAS Software User Guide
ThinkServer RD230, RD240, and TD230
MegaRAID SAS Software User Guide
First Edition (June 2010)
© Copyright Lenovo 2010.
LENOVO products, data, computer software, and services have been developed exclusively at private expense and
are sold to governmental entities as commercial items as defined by 48 C.F.R. 2.101 with limited and restricted
rights to use, reproduction and disclosure.
LIMITED AND RESTRICTED RIGHTS NOTICE: If products, data, computer software, or services are delivered
pursuant a General Services Administration GSA contract, use, reproduction, or disclosure is subject to restrictions
set forth in Contract No. GS-35F-05925.
Note
Before using this information and the product it supports, be sure to read and understand the following:
v The Important Notices that comes with your product
v The Safety Information and the Warranty and Support Information on the ThinkServer Documentation DVD that comes with
your product
v Appendix C, “Notices.
Preface 1
Preface
This document e
xplains how to use the MegaRAID Storage Manager™
software, WebBIOS, and Command Line Interface (CLI) utilities to
configure, monitor, and maintain MegaRAID
®
Serial-attached SCSI
(SAS)
RAID controllers and the storage-related devices connected to
them.
Audience
This document assumes that you
are familiar with SAS controllers and
configuration utilities. The people who benefit from this book are network
administrators who need to create storage configurations on 7KLQN6HU
YHUSAS controllers.
Organization
This do
cument has the following chapters and appendixes:
Chapter 1, “Overv
iew, describes the SAS, Serial ATA (SATA) II, and
Solid State Disk (SSD) technologies, configuration scenarios, and
Technical Support information.
Chapter 2,
“Introduction to RAID, describes RAID (Redundant Array
of Independent Disks), RAID functions and benefits, RAID
components, RAID levels, and configuration strategies. In addition, it
defines the RAID availability concept, and offers tips for configuration
planning.
Chapter 3, “Full Disk Encry
ption, describes the Full Disk Encryption
(FDE) features, terminology, and workflow.
Chapter 4, “WebBIOS Configuration Utility
, explains how to use the
pre-boot WebBIOS Configuration Utility to create and manage
storage configurations.
Preface 2
Chapter 5, “M
egaRAID Command Tool, explains how to use the
MegaRAID Command Tool to create and manage storage
configurations. The MegaRAID Command Tool is a CLI application
for SAS.
Chapter 6, “Me
gaRAID Storage Manager Overview and Installation,
introduces the main features of MegaRAID Storage Manager
software and explains how to install it.
Chapter 7, “M
egaRAID Storage Manager Window and Menus,
describes the layout of the MegaRAID Storage Manager window and
lists the available menu options.
Chapter 8, “Con
figuration, describes how to use the MegaRAID
Storage Manager software to configure or reconfigure storage
devices, how to save configurations, and how to apply saved
configurations to a controller.
Chapter 9, “M
onitoring System Events and Storage Devices,
explains how the MegaRAID Storage Manager software monitors the
status of storage configurations and devices and displays information
about them.
Chapter 10, “Maint
aining and Managing Storage Configurations,
describes the MegaRAID Storage Manager maintenance functions
for virtual drives and other storage devices.
Appendix A, “Eve
nts and Messages, provides descriptions of the
MegaRAID Storage Manager events.
Appendix B, “G
lossary, contains definitions of storage-related terms.
Con
ventions
Note:
Notes contain supplementary information that can have an
effect on system performance.
Caution:
Cautions are notifications that an action has the potential to
adversely affect equipment operation, system performance,
or data integrity.
Appendix CNotices, contains Notices information.
MegaRAID SAS Software User Guide
Contents
Chapter 1
Overview
1.1 SAS T
echnology 1-1
1.2 Serial-attached SCSI Device Interface 1-3
1.3 Serial ATA II Features 1-3
1.4 Solid State Drive Features 1-4
1.4.1 Solid State Drive Guard 1-4
1.5 Dimmer Switch Feature 1-5
1.6 UEFI 2.0 Support 1-5
1.7 Configuration Scenarios 1-6
1.7.1 Valid Drive Mix Configurations with HDDs and
SSDs 1-8
Chapter 2
Introduction to RAID
2.1 RAID Description 2-1
2.2 RAID Benefits 2-1
2.3 RAID Functions 2-1
2.4 Components and Features 2-2
2.4.1 Physical Array 2-2
2.4.2 Virtual Drive 2-2
2.4.3 RAID Drive Group 2-3
2.4.4 Fault Tolerance 2-3
2.4.5 Consistency Check 2-5
2.4.6 Copyback 2-5
2.4.7 Background Initialization 2-6
2.4.8 Patrol Read 2-7
2.4.9 Disk Striping 2-7
Contents
2.4.10 Disk M
irroring 2-8
2.4.11 Parity 2-9
2.4.12 Disk Spanning 2-10
2.4.13 Hot Spares 2-11
2.4.14 Disk Rebuilds 2-13
2.4.15 Rebuild Rate 2-14
2.4.16 Hot Swap 2-14
2.4.17 Drive States 2-15
2.4.18 Virtual Drive States 2-15
2.4.19 Enclosure Management 2-16
2.5 RAID Levels 2-16
2.5.1 Summary of RAID Levels 2-16
2.5.2 Selecting a RAID Level 2-18
2.5.3 RAID 0 2-18
2.5.4 RAID 1 2-19
2.5.5 RAID 5 2-20
2.5.6 RAID 6 2-21
2.5.7 RAID 00 2-22
2.5.8 RAID 10 2-24
2.5.9 RAID 50 2-25
2.5.10 RAID 60 2-26
2.6 RAID Configuration Strategies 2-28
2.6.1 Maximizing Fault Tolerance 2-28
2.6.2 Maximizing Performance 2-30
2.6.3 Maximizing Storage Capacity 2-32
2.7 RAID Availability 2-33
2.7.1 RAID Availability Concept 2-33
2.8 Configuration Planning 2-34
2.8.1 Number of Drives 2-34
2.8.2 Drive Group Purpose 2-35
Chapter 3
Full Disk En
cryption
3.1 Overview 3-1
3.2 Purpose 3-2
3.3 Terminology 3-2
3.4 Workflow 3-3
Contents
3.4.1 En
able Security 3-3
3.4.2 Change Security 3-4
3.4.3 Create Secure Virtual Drives 3-5
3.4.4 Import a Foreign Configuration 3-6
3.5 Instant Secure Erase 3-7
Chapter 4
WebBIOS Config
uration Utility
4.1 Overview 4-1
4.2 Starting the WebBIOS CU 4-2
4.3 WebBIOS CU Main Screen Options 4-3
4.4 Creating a Storage Configuration 4-5
4.4.1 Selecting the Configuration with the Configuration
Wizard 4-6
4.4.2 Using Automatic Configuration 4-8
4.4.3 Using Manual Configuration 4-9
4.5 Selecting Full Disk Encryption Security Options 4-58
4.5.1 Enabling the Security Key Identifier, Security Key,
and Passphrase 4-59
4.5.2 Changing the Security Key Identifier, Security Key,
and Pass Phrase 4-64
4.5.3 Disabling the Drive Security Settings 4-71
4.5.4 Importing Foreign Configurations 4-73
4.6 Viewing and Changing Device Properties 4-74
4.6.1 Viewing and Changing Controller Properties 4-74
4.6.2 Viewing and Changing Virtual Drive Properties 4-78
4.6.3 Viewing Drive Properties 4-80
4.6.4 Viewing and Changing Battery Backup Unit
Information 4-82
4.7 Viewing System Event Information 4-85
4.8 Managing Configurations 4-87
4.8.1 Running a Consistency Check 4-87
4.8.2 Deleting a Virtual Drive 4-88
4.8.3 Importing or Clearing a Foreign Configuration 4-88
4.8.4 Migrating the RAID Level of a Virtual Drive 4-92
Contents
Chapter 5
MegaRAID Command T
ool
5.1 Product Overview 5-2
5.2 Novell NetWare, SCO, Solaris, FreeBSD, and DOS
Operating System Support 5-4
5.3 Command Line Abbreviations and Conventions 5-4
5.3.1 Abbreviations Used in the Command Line 5-4
5.3.2 Conventions 5-5
5.4 Controller Property-Related Options 5-6
5.4.1 Display Controller Properties 5-6
5.4.2 Display Number of Controllers Supported 5-7
5.4.3 Enable or Disable Automatic Rebuild 5-7
5.4.4 Flush Controller Cache 5-7
5.4.5 Set Controller Properties 5-8
5.4.6 Display Specified Controller Properties 5-9
5.4.7 Set Factory Defaults 5-10
5.4.8 Set SAS Address 5-10
5.4.9 Set Time and Date on Controller 5-10
5.4.10 Display Time and Date on Controller 5-11
5.5 Patrol Read-Related Controller Properties 5-11
5.5.1 Set Patrol Read Options 5-11
5.5.2 Set Patrol Read Delay Interval 5-12
5.6 BIOS-Related Properties 5-12
5.6.1 Set or Display Bootable Virtual Drive ID 5-13
5.6.2 Select BIOS Status Options 5-13
5.7 Battery Backup Unit-Related Properties 5-13
5.7.1 Display BBU Information 5-14
5.7.2 Display BBU Status Information 5-14
5.7.3 Display BBU Capacity 5-15
5.7.4 Display BBU Design Parameters 5-16
5.7.5 Display Current BBU Properties 5-16
5.7.6 Start BBU Learning Cycle 5-17
5.7.7 Place Battery in Low-Power Storage Mode 5-17
5.7.8 Set BBU Properties 5-17
5.8 Options for Displaying Logs Kept at Firmware Level 5-18
5.8.1 Event Log Management 5-18
5.8.2 Set BBU Terminal Logging 5-19
Contents
5.9 Con
figuration-Related Options 5-19
5.9.1 Create a RAID Drive Group from All Unconfigured
Good Drives 5-20
5.9.2 Add RAID 0, 1, 5, or 6 Configuration 5-21
5.9.3 Add RAID 10, 50, or 60 Configuration 5-23
5.9.4 Clear the Existing Configuration 5-23
5.9.5 Save the Configuration on the Controller 5-24
5.9.6 Restore the Configuration Data from File 5-24
5.9.7 Manage Foreign Configuration Information 5-24
5.9.8 Delete Specified Virtual Drive(s) 5-25
5.9.9 Display the Free Space 5-25
5.10 Virtual Drive-Related Options 5-26
5.10.1 Display Virtual Drive Information 5-26
5.10.2 Change the Virtual Drive Cache and Access
Parameters 5-26
5.10.3 Display the Virtual Drive Cache and Access
Parameters 5-27
5.10.4 Manage Virtual Drives Initialization 5-27
5.10.5 Manage a Consistency Check 5-28
5.10.6 Manage a Background Initialization 5-28
5.10.7 Perform a Virtual Drive Reconstruction 5-29
5.10.8 Display Information about Virtual Drives and
Drives 5-29
5.10.9 Display the Number of Virtual Drives 5-29
5.11 Drive-Related Options 5-30
5.11.1 Display Drive Information 5-30
5.11.2 Set the Drive State to Online 5-30
5.11.3 Set the Drive State to Offline 5-30
5.11.4 Change the Drive State to Unconfigured Good 5-31
5.11.5 Change Drive State 5-31
5.11.6 Manage a Drive Initialization 5-32
5.11.7 Rebuild a Drive 5-32
5.11.8 Locate the Drive(s) and Activate LED 5-33
5.11.9 Mark the Configured Drive as Missing 5-33
5.11.10 Display the Drives in Missing Status 5-33
5.11.11 Replace the Configured Drives and Start an
Automatic Rebuild 5-33
5.11.12 Prepare the Unconfigured Drive for Removal 5-34
Contents
5.11.13 Disp
lay Total Number of Drives 5-34
5.11.14 Display List of Physical Devices 5-34
5.11.15 Download Firmware to the Physical Devices 5-35
5.12 Enclosure-Related Options 5-35
5.13 Flashing the Firmware 5-35
5.13.1 Flash the Firmware with the ROM File 5-36
5.13.2 Flash the Firmware in Mode 0 with the ROM File 5-36
5.14 SAS Topology 5-36
5.15 Diagnostic-Related Options 5-37
5.15.1 Start Controller Diagnostics 5-37
5.15.2 Start Battery Test 5-37
5.15.3 Start NVRAM Diagnostic 5-38
5.16 Miscellaneous Options 5-38
5.16.1 Display the MegaCLI Version 5-38
5.16.2 Display Help for MegaCLI 5-38
Chapter 6
MegaRAID Storag
e Manager Overview and Installation
6.1 Overview 6-1
6.1.1 Creating Storage Configurations 6-1
6.1.2 Monitoring Storage Devices 6-2
6.1.3 Maintaining Storage Configurations 6-2
6.2 Hardware and Software Requirements 6-2
6.3 Installing MegaRAID Storage Manager 6-3
6.3.1 Installing MegaRAID Storage Manager Software on
Microsoft Windows 6-3
6.3.2 Installing MegaRAID Storage Manager Software for
Linux 6-8
6.3.3 Linux Error Messages 6-9
6.4 MegaRAID Storage Manager Support and Installation on
VMWare 6-10
6.4.1 Installing MegaRAID Storage Manager for
VMWare Classic 6-10
6.4.2 Uninstalling MegaRAID Storage Manager for
VMWare 6-11
6.4.3 Installing MegaRAID Storage Manager Support
on the VMWare ESX Operating System 6-11
6.5 Installing and Configuring a CIM Provider 6-23
Contents
6.5.1 Installing a CIM SAS Stor
age Provider on Linux 6-23
6.5.2 Installing a CIM SAS Storage Provider on
Windows 6-25
6.6 Installing and Configuring an SNMP Agent 6-25
6.6.1 Installing and Configuring an SNMP Agent on
Linux 6-26
6.6.2 Installing and Configuring an SNMP Agent on
Solaris 6-28
6.6.3 Installing an SNMP Agent on Windows 6-32
6.7 MegaRAID Storage Manager Support and Installation on
Solaris 10 6-33
6.7.1 Installing MegaRAID Storage Manager Software
for Solaris 10 6-33
6.7.2 Uninstalling MegaRAID Storage Manager Software
for Solaris 10 6-34
Chapter 7
MegaRAID Storag
e Manager Window and Menus
7.1 Starting MegaRAID Storage Manager Software 7-1
7.2 MegaRAID Storage Manager Window 7-4
7.2.1 Physical/Logical View Panel 7-5
7.2.2 Properties/Operations Panels 7-6
7.2.3 Event Log Panel 7-7
7.2.4 Menu Bar 7-8
Chapter 8
Configuration
8.
1 Creating a New Storage Configuration 8-2
8.1.1 Selecting Virtual Drive Settings 8-2
8.1.2 Creating a Virtual Drive Using Simple Configuration 8-4
8.1.3 Creating a Virtual Drive Using Advanced
Configuration 8-9
8.2 Selecting Full Disk Encryption Security Options 8-18
8.2.1 Enabling Drive Security 8-18
8.2.2 Changing the Security Key Identifier, Security Key,
and Pass Phrase 8-24
8.2.3 Disabling Drive Security 8-30
8.2.4 Importing or Clearing a Foreign Configuration 8-32
Contents
8.3 Add
ing Hot Spare Drives 8-35
8.4 Changing Adjustable Task Rates 8-37
8.5 Changing Power Settings 8-39
8.6 Changing Virtual Drive Properties 8-40
8.7 Changing a Virtual Drive Configuration 8-41
8.7.1 Accessing the Modify Drive Group Wizard 8-41
8.7.2 Adding a Drive or Drives to a Configuration 8-43
8.7.3 Removing a Drive from a Configuration 8-44
8.7.4 Changing the RAID Level of a Virtual Drive 8-45
8.8 Deleting a Virtual Drive 8-45
8.9 Saving a Storage Configuration to Drive 8-46
8.10 Clearing a Storage Configuration from a Controller 8-46
8.11 Adding a Saved Storage Configuration 8-47
Chapter 9
Monitori
ng System Events and Storage Devices
9.1 Monitoring System Events 9-1
9.2 Configuring Alert Notifications 9-3
9.2.1 Setting Alert Delivery Methods 9-5
9.2.2 Changing Alert Delivery Methods for Individual
Events 9-6
9.2.3 Changing the Severity Level for Individual Events 9-7
9.2.4 Entering or Editing the Sender Email Address and
SMTP Server 9-9
9.2.5 Authenticating a Server 9-10
9.2.6 Saving Backup Configurations 9-10
9.2.7 Loading Backup Configurations 9-10
9.2.8 Adding Email Addresses of Recipients of Alert
Notifications 9-11
9.2.9 Testing Email Addresses of Recipients of Alert
Notifications 9-12
9.2.10 Removing Email Addresses of Recipients of Alert
Notifications 9-13
9.3 Monitoring Controllers 9-13
9.4 Monitoring Drives 9-15
9.5 Running a Patrol Read 9-16
9.6 Monitoring Virtual Drives 9-19
9.7 Monitoring Enclosures 9-21
Contents
9.8 Monitoring Battery Backup
Units 9-22
9.8.1 Battery Learn Cycle 9-24
9.9 Monitoring Rebuilds and Other Processes 9-26
Chapter 10
Maintaining
and Managing Storage Configurations
10.1 Initializing a Virtual Drive 10-1
10.2 Running a Consistency Check 10-2
10.3 Scanning for New Drives 10-3
10.4 Rebuilding a Drive 10-3
10.5 Making a Drive Offline or Missing 10-4
10.6 Upgrading the Firmware 10-5
Appendix A
Events and M
essages
Appendix B
Glossar
y
Appendix C
Notices
Contents
Contents
Figures
1-7
2.1
Example of Disk Striping (RAID 0) 2-8
2.2 Example of Disk Mirroring (RAID 1) 2-9
2.3 Example of Distributed Parity (RAID 5) 2-10
2.4 Example of Disk Spanning 2-10
2.5 RAID 0 Drive Group Example with Two Drives 2-19
2.6 RAID 1 Drive Group 2-20
2.7 RAID 5 Drive Group with Six Drives 2-21
2.8 Example of Distributed Parity across Two Blocks in a
Stripe (RAID 6) 2-22
2.9 RAID 00 Drive Group Example with Two Drives 2-23
2.10 RAID 10 Level Virtual Drive 2-25
2.11 RAID 50 Level Virtual Drive 2-26
2.12 RAID 60 Level Virtual Drive 2-28
4.1 WebBIOS CU Main Screen 4-3
4.2 WebBIOS Configuration Wizard Screen 4-6
4.3 WebBIOS Configuration Method Screen 4-7
4.4 WebBIOS Disk Group Definition Screen 4-10
4.5 WebBIOS Virtual Drive Definition Screen 4-11
4.6 RAID 0 Configuration Preview 4-14
4.7 WebBIOS Disk Group Definition Screen 4-15
4.8 WebBIOS Virtual Drive Definition Screen 4-16
4.9 RAID 1 Configuration Preview 4-19
4.10 WebBIOS Disk Group Definition Screen 4-20
4.11 WebBIOS Virtual Drive Definition Screen 4-21
4.12 RAID 5 Configuration Preview 4-24
4.13 WebBIOS Disk Group Definition Screen 4-26
4.14 WebBIOS Virtual Drive Definition Screen 4-27
4.15 RAID 6 Configuration Preview 4-30
4.16 WebBIOS Disk Group Definition Screen 4-32
4.17 WebBIOS Span Definition Screen 4-33
4.18 WebBIOS Virtual Drive Definition Screen 4-34
4.19 RAID 00 Configuration Preview 4-37
4.20 WebBIOS Drive Group Definition Screen
1-71.1 Example of a ThinkServer SAS Di rect-Connect Application
1.2 Example of a ThinkServerI SAS RAID Controller Configured
with a ThinkServer SASx12 Expander
Contents
4.21 WebBI
OS Span Definition Screen 4-40
4.22 WebBIOS Virtual Drive Definition Screen 4-41
4.23 RAID 10 Configuration Preview 4-44
4.24 WebBIOS Disk Group Definition Screen 4-46
4.25 WebBIOS Span Definition Screen 4-47
4.26 WebBIOS Virtual Drive Definition Screen 4-48
4.27 RAID 50 Configuration Preview 4-51
4.28 WebBIOS Disk Group Definition Screen 4-53
4.29 WebBIOS Span Definition Screen 4-54
4.30 WebBIOS Virtual Drive Definition Screen 4-55
4.31 RAID 60 Configuration Preview 4-58
4.32 Encryption Settings Screen 4-59
4.33 Enable Drive Security - Introduction Screen 4-60
4.34 Enable Drive Security – Enter Security Key ID Screen 4-61
4.35 Enable Drive Security – Enter Security Key 4-62
4.36 Enable Drive Security – Enter Pass Phrase 4-63
4.37 Confirm Enable Drive Security Screen 4-64
4.38 Encryption Settings Screen 4-65
4.39 Change Security Settings – Introduction 4-66
4.40 Change Security Settings – Security Key ID 4-67
4.41 Change Security Settings – Security Key 4-68
4.42 Authenticate Drive Security Key 4-69
4.43 Change Security Settings – Pass Phrase 4-70
4.44 Confirm Change Drive Security Settings 4-71
4.45 Encryption Settings 4-72
4.46 Confirm Disable Drive Security Settings 4-73
4.47 First Controller Properties Screen 4-74
4.48 Second Controller Properties Screen 4-75
4.49 Third Controller Properties Screen 4-76
4.50 Virtual Drive Screen 4-79
4.51 Physical Drive Screen 4-81
4.52 First Controller Properties Screen 4-83
4.53 Second Controller Properties Screen 4-83
4.54 Battery Module Screen 4-84
4.55 Event Information Screen 4-86
4.56 Foreign Configuration Import Screen 4-89
4.57 Foreign Configuration Preview Screen 4-90
6.1 Customer Information Screen 6-4
Contents
6.2 Set
up Type Screen 6-5
6.3 Setup Type Screen 6-6
6.4 Custom Setup Screen 6-7
6.5 Server Screen 6-8
6.6 Host ESXi Server Name 6-14
6.7 Login on the Host Server 6-15
6.8 Physical View 6-16
6.9 Logical View 6-17
7.1 Select Server Window 7-2
7.2 Server Login Window 7-3
7.3 Main MegaRAID Storage Manager Window 7-4
7.4 Operations Tab 7-7
8.1 Virtual Drive Creation Menu 8-5
8.2 Virtual Drive Creation Mode 8-6
8.3 Create Virtual Drive Screen 8-7
8.4 Create Virtual Drive - Summary Window 8-8
8.5 Virtual Drive Creation Menu 8-10
8.6 Virtual Drive Creation Mode 8-11
8.7 Create Drive Group Settings Screen 8-12
8.8 Span 0 of Drive Group 0 8-13
8.9 Span 0 and Span 1 of Drive Group 0 8-14
8.10 Virtual Drive Settings Window 8-15
8.11 New Virtual Drive 0 8-16
8.12 Create Virtual Drive Summary Window 8-17
8.13 Drive Security Settings Menu 8-19
8.14 Enable Drive Security - Introduction Screen 8-20
8.15 Enter Security Key ID Screen 8-21
8.16 Enter Security Key Screen 8-22
8.17 Enable Drive Security - Enter Pass Phrase Screen 8-23
8.18 Confirm Create Security Key Screen 8-24
8.19 Change Drive Security Menu 8-25
8.20 Change Security Settings - Introduction Screen 8-26
8.21 Change Security Settings - Security Key ID Screen 8-27
8.22 Change Security Settings - Security Key Screen 8-28
8.23 Authenticate Drive Security Settings Screen 8-29
8.24 Change Security Settings - Pass Phrase Screen 8-29
8.25 Change Drive Security Menu 8-31
8.26 Confirm Disable Drive Security Screen 8-32
Contents
8.27 F
oreign Configuration Detected Screen 8-34
8.28 Creating a Global Hot Spare 8-36
8.29 Set Adjustable Task Rates 8-38
8.30 Set Virtual Drive Properties 8-40
8.31 Data Backup Warning 8-42
8.32 Modify Drive Group Wizard 8-43
9.1 Event Information Window 9-2
9.2 Alert Notification Configuration Menu 9-3
9.3 Alerts Notification Configuration Screen 9-4
9.4 Alert Notification Delivery Methods Dialog Box 9-6
9.5 Change Individual Events Dialog Box 9-7
9.6 Change Individual Events Severity Level Menu 9-8
9.7 Mail Server Options 9-9
9.8 Email Settings 9-12
9.9 Controller Information 9-14
9.10 Drive Information 9-15
9.11 Patrol Read Configuration 9-17
9.12 Virtual Drive Properties 9-20
9.13 Enclosure Information – Graphical View 9-22
9.14 Battery Backup Unit Information 9-23
9.15 Battery Backup Unit Operations 9-25
9.16 Group Show Progress Window 9-26
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364

Lenovo THINKSERVER TD230 Software User's Manual

Category
RAID controllers
Type
Software User's Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI