Paradyne 6301 Installation guide

Category
Routers
Type
Installation guide

This manual is also suitable for

1
Hotwirer 6321/6322 IDSL Routers
Installation Instructions
Document Number 6321-A2-GN10-00
March 2000
Contents
Hotwire 6321/6322 IDSL Routers Overview 2. . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring and Cables Needed 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the DSL Access Wiring 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the DSL Access Wiring 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Hotwire 6321/6322 IDSL Router 6. . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cables & Connectors 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Library Technical Manuals Hotwire DSL and MVL Systems.
Select the following document:
6371-A2-GB20
Hotwire DSL Routers User’s Guide
To order a paper copy of a Paradyne document:
H Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
H Outside the U.S.A., call 1-727-530-8623
Product-Related Documents
Document Number Document Title
8000-A2-GB26 Hotwire MVL, RADSL, IDSL, and Packet SDSL Cards,
Models 8310/8312, 8510/8373/8374, 8323/8324, and
8343/8344, User’s Guide
2
Hotwire 6321/6322 IDSL Routers Overview
The Hotwirer 6321 and 6322 ISDL (Integrated Services Digital Network Digital
Subscriber Line) Routers are components in the Hotwire DSLAM (Digital Subscriber
Line Access Multiplexer) system. Both Hotwire IDSL Routers interoperate with either
the Hotwire 8323 or 8324 IDSL Card:
H Hotwire 6321 IDSL Router with one Ethernet port
H Hotwire 6322 IDSL Router with a 4-port Ethernet hub
Both the Hotwire 6321 and the Hotwire 6322 IDSL Routers operate as an IP router
connecting a DSL link to an Ethernet network. The Hotwire IDSL packet-based system
provides high-speed Internet or corporate LAN access over a combination of traditional
twisted-pair copper telephone wiring and ISDN transport, such as T1 or fiber. These
products have three data channels that are configurable for a total of 144 kbps.
Network Overview with a Hotwire 6321 IDSL Router
00-16667
Punchdown
Block or NID
DSL
Jack
6321
IDSL
Router
Customer Premises (CP)
DSL
Ethernet
Crossover
Cable
Ethernet
Cable
or
Central
Office
(CO)
Demarcation
Point
Local
Loop
Hub
End-user
Systems
DSL – Digital Subscriber Line New Wiring Connections
NID – Network Interface Device
Service
Provider
Remote
Terminal
(RT)
Digital
Loop
Carrier
(DLC)
NOTES:
In this document:
End-user system is used to represent any host with an Ethernet connection.
Service provider is used to represent any Internet Service Provider (ISP) or
remote LAN provider.
3
Network Overview with a Hotwire 6322 IDSL Router
00-16668
Punchdown
Block or NID
DSL
Jack
6322
IDSL
Router
Customer Premises (CP)
DSL
Ethernet
Crossover
Cable
Ethernet Straight
Through Cables
Demarcation
Point
Hub
End-user
Systems
DSL Digital Subscriber Line New Wiring Connections
NID Network Interface Device
Central
Office
(CO)
Local
Loop
Service
Provider
Remote
Terminal
(RT)
Digital
Loop
Carrier
(DLC)
NOTE:
For Ethernet cabling details, refer to Installing the Hotwire 6321/6322 IDSL Router
on page 6.
Package Checklist
Verify that your package contains the following:
-
Model 6321 or Model 6322 IDSL Router
-
DSL interface cable with RJ11 modular plugs
-
Power cord with power transformer
Wiring and Cables Needed
You will need the following wiring and standard connectors with this product:
-
Standard RJ11 wall jack for the DSL cabling.
-
DSL cabling: New or existing unshielded twisted-pair wiring (CAT3 or better). The
CAT3 wiring must meet EIA/TIA-568 specifications with 24 AWG (.5 mm) or
26 AWG (.4 mm).
-
Ethernet cabling: New or existing shielded twisted-pair wiring (CAT5 or better). The
CAT5 wiring must meet EIA/TIA-568 specifications with 24 AWG (.5 mm) or
26 AWG (.4 mm). A straight-through or crossover Ethernet cable is used.
Refer to Installing the Hotwire 6321/6322 IDSL Router on page 6 for cabling details.
4
Optional Cable
The Hotwire 6321/6322 IDSL Routers are typically configured remotely by the service
provider. The following optional cabling and adapter are only used with this product to
configure the router locally:
-
Console cabling: Straight-through cable with 8-pin non-keyed modular plugs
(Part No. 035-0276-1431)
-
Console adapter:
8-pin modular to DB9 adapter plug (Part No. 002-0093-0031), or
A configurable RJ to DB9 adapter wired as shown in Cables & Connectors
on page 13.
Installing the DSL Access Wiring
The local loop terminates at the punchdown block or NID. Wiring must be connected
from the customer premises side of the punchdown block or the NID to an RJ11 jack.
Typically, the punchdown block is installed in commercial locations and the NID is
installed in residential locations.
" Procedure
1. Access the punchdown block or NID.
!
WARNING:
Do not continue unless the DSL access line from the local loop has been
disconnected at the NID or punchdown block. Refer to Important Safety
Instructions on page 18.
2. Disconnect the DSL access pair from the local loop. A punchdown block is used in
the following example.
ABCD
DSL
Access
from Local
Loop
Wiring to
DSL Jack
Bridge Clip
Punchdown Block
97-15348
Demarcation Point
Customer Premises
5
3. Locate the DSL pair of T1/R1 connectors on the customer premises side of the
NID or punchdown block. Attach the wiring that will be connected to the DSL jack.
Connecting to the DSL Access Wiring
The Hotwire 6321 or 6322 IDSL Router connects to the local loop via wiring from the
demarcation point to an RJ11 wall jack. The DSL twisted-pair wiring from the local loop
terminates at a new or existing wall jack. It may be necessary to install a standard
single RJ11 jack or replace a single jack with a double RJ11 jack.
99-16589
DSL
RJ11
Jack
Central
Office
Punchdown
Block or NID
Customer Premises
DSL
Local Loop
Demarcation Point
DSL
Twisted-pair
Wiring
DSL
Router
" Procedure
1. Wiring can be run from the punchdown block or NID to a new or existing wall jack.
Match the pair colors on both ends.
2. Label the DSL jack.
3. Reconnect the DSL access pair at the punchdown block or NID. Tighten both
terminal screws with a flat-blade screwdriver.
The RJ11 6-pin jack uses the center two pins. For pin assignments, refer to Cables &
Connectors on page 13.
6
Installing the Hotwire 6321/6322 IDSL Router
Place the Hotwire 6321/6322 IDSL Router on a flat surface with clearance for the rear
connectors.
NOTE:
The following illustrations show the Hotwire 6322 IDSL Router with a 4-port
Ethernet hub. The Hotwire 6321 IDSL Router is identical except that it has one
Ethernet port.
" Procedure
1. Use the RJ11 6-pin cable for the DSL connection. Insert one end of the cable into
the jack labeled DSL. Insert the other end into the wall jack labeled DSL.
00-16669
DSL
Jack
POWER
CONSOLE
DSL
2
1
ETHERNET
3
4
6322 IDSL Router
If you are installing a . . . Then go to . . .
Hotwire 6321 IDSL Router page 7
Hotwire 6322 IDSL Router page 8
7
2. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the
cable into the jack labeled ETHERNET.
If you are installing the Hotwire 6322 IDSL Router, go to page 8.
H For a 6321 IDSL Router, use a straight-through cable to connect the other end
to an Ethernet hub. Do not connect a straight-through cable to the external
hubs UPLINK connection (this connection requires a crossover cable).
POWER
CONSOLE
DSL
ETHERNET
00-16670
Ethernet
Line
Ethernet
Hub
Ethernet
Straight-through
Cable
8
7
6
5
4
3
2
1
6321 IDSL Router
-or-
H For a 6321 IDSL Router, use an Ethernet crossover cable and connect the
other end to a PC with an Ethernet Network Interface Card (NIC) installed.
POWER
CONSOLE
DSL
ETHERNET
00-16671
PC with Ethernet
Network Interface
Card (NIC)
Ethernet
Line
Ethernet
Crossover
Cable
6321 IDSL Router
8
If you are installing the Hotwire 6321 IDSL Router, go to page 7.
H For a 6322 IDSL Router, use a straight-through cable to connect the other end
to a PC with an Ethernet Network Interface Card (NIC) installed.
-and/or-
H Use an Ethernet crossover cable to connect the other end to an external hub.
00-16672
Ethernet
Crossover
Cable
Ethernet
Hub
8
7
6
5
4
3
2
1
Ethernet
Line
POWER
CONSOLE
DSL
2
1
ETHERNET
3
4
6322 IDSL Router
For the IDSL router cable pin assignments, refer to Cables & Connectors on
page 13.
3. The Console port acts as a DCE and uses an 8-pin straight-through cable for the
connection to a VT100-compatible terminal or a PC running a terminal emulation
program.
This is an optional connection used only for local configuration of the DSL router.
For details, refer to Local Console Access on page 12.
Connect the DB9 adapter to the PC and connect the cable to a PC or laptop. lnsert
one end of the straight-through cable into the jack labeled CONSOLE. Insert the
other end into the DB9 adapter for the serial port of the VT100 terminal or PC.
POWER
CONSOLE
DSL
2
1
ETHERNET
3
4
6322 IDSL Router
VT100 Terminal
or PC
(9-pin Adapter)
00-16673
Console
Serial Line
9
4. Insert the supplied power cords round end into the jack labeled POWER. Plug the
transformer into an ac outlet.
POWER
CONSOLE
DSL
2
1
ETHERNET
3
4
00-16674
18 Vdc
800 MA
Transformer
Power
Jack
6322 IDSL Router
The Hotwire 6321/6322 IDSL Router hardware installation is now complete. When the
power cord is installed, the IDSL router goes through a power-on self-test.
Power-On
When power is applied, the Hotwire 6321/6322 IDSL Router performs self-diagnostics
and the PWR LED is on. The self-diagnostics includes a power-on self-test. During the
power-on self-test, all of the LEDs turn on for one second.
TST DSL
ETHERNET
ALMPWR
TM
00-16675
Power green
Alarm red
Test yellow
Digital Subscriber Line green
Ethernet Link 1 to 4 green
6322
1234
Refer to Troubleshooting on page 11 for LED indications requiring action.
10
Status LEDs
All of the LEDs turn on and off during the power-on self-test. After a successful
self-test, the LEDs should appear as indicated in BOLD in the Condition column below.
LED Condition Status
PWR ON The IDSL router has power.
ALM Blinking
OFF
ON
The IDSL router has detected a system failure.
No active alarms.
An alarm condition exists.
TST OFF
ON
No active tests.
The TST LED is on during the power-on self-test and
during a test initiated by the service provider.
DSL Blinking
ON
OFF
The IDSL router is establishing the active DSL link. The
LED blinks on and off about five times per second.
The DSL link is now active and ready to transmit and
receive data.
The DSL link has not been established.
ETHERNET
LINKS 14
ON
OFF
The Ethernet connection is active.
No Ethernet 10/100BaseT device is detected.
11
Troubleshooting
LED Symptom Action
All LEDs are on. If the LEDs remain on after ten minutes, the IDSL router is not
functional. Contact the service provider.
ALM LED remains
on.
The power-on self-test may have failed. Unplug the unit and
reapply power. If the alarm LED is still on, contact the service
provider.
ALM and TST
LEDs are blinking.
Firmware download may be in progress. If firmware download
is not in progress or the LEDs continue blinking after ten
minutes, contact the service provider.
DSL LED is off. Verify that the DSL cable is securely installed on both ends. If
the problem continues, contact the service provider.
DSL LED continues
to blink after the
power-on self-test.
The IDSL router is attempting to establish the DSL link or
adjusting the rate of the DSL line due to line conditions. If the
DSL LED continues to blink for more than ten minutes, contact
the service provider.
DSL LED is on and
there is no data
transmission.
The DSL link has been established but there is no data
transmission. First, verify the Ethernet connection. If the
problem persists, contact the service provider.
DSL & ETHERNET
LEDs are on and
there is no data
transmission.
The DSL link and the Ethernet link have been established but
there is no data transmission. If the problem continues, contact
the service provider.
ETHERNET LED is
off.
Verify that the Ethernet cable is securely installed at both ends,
and at least one PC is connected and powered on.
Verify that the correct straight-through or crossover cable is
installed. Refer to Installing the Hotwire 6321/6322 IDSL
Router on page 6.
PWR LED is off.
Check that the power cord is securely installed on both ends.
If no LEDs are on, the power supply may be defective. Test the
outlet to verify power. If the problem persists, contact the
service provider.
If other LEDs are on, the PWR LED may be burned out. Unplug
the unit and reapply power; watch all LEDs during the
power-on self-test to verify that the PWR LED is functioning.
TST LED is on. A test initiated by the service provider may be active. Wait five
minutes. If the TST LED does not go off, contact the service
provider.
12
Hotwire 6321/6322 IDSL Router Configuration Setup
The Console cable is connected to a VT100-compatible terminal or a PC running a
terminal emulation program. Verify the terminal settings:
H Data rate set to 19.2 kbps (19200 bps)
H Character length set to 8
H Parity set to None
H Stop bits set to 1
H Flow control set to Off or None
Local Console Access
When the local console connection is first established, access control to the IDSL
router displays an initial prompt of Login>.
" Procedure
1. At the initial prompt of Login>, enter the factory default Login ID of paradyne.
2. At the password> prompt, enter the factory default Password of abc123.
3. At the next prompt for System ID, the factory default is CUSTOMER>.
Type show system to display hardware/firmware information and Selftest Results
(optional).
Refer to the Hotwire DSL Routers Users Guide for configuration settings and
command line entries.
Increasing the Number of End-User Systems
The Hotwire 6321/6322 IDSL Router can support differing numbers of end-user
systems depending on the functions that are enabled and traffic loading. Typical
configurations will provide support for up to 32, 64, or 256 hosts (end-user systems).
The number of end-user systems can be increased with the use of subnets utilizing
static addressing or by using a default gateway connection.
Increasing the number of PCs may require cabling changes. Refer to Cables &
Connectors on page 13.
Refer to the Hotwire DSL Routers Users Guide for configuration settings and
command line entries.
98-15304-01
6-Pin
RJ11 Plug
DSL
Cable
Pin #1
Pin #6
97-15678
8-Pin
Plug
Console Port
Cable
Pin #1
Pin #8
98-16050
DB9
to RJ45
13
Cables & Connectors
This section is reference information.
Use a CAT3 or better cable for the DSL line.
H The DSL interface connector uses a 6-pin,
non-keyed modular plug.
RJ11 6-Pin Connector
Pin # Function
1 & 2 Not used
3 DSL Ring
4 DSL Tip
5 & 6 Not used
H The Console connector uses 8-pin non-keyed modular plugs and a DB9 adapter.
See Hotwire 6321/6322 IDSL Router Configuration Setup on page 12.
RJ45 8-Pin Connector
Pin # Circuit Direction
1 Not used
2
DTR Input to
Console port
3 TXD Input
4 Signal Ground
5 Signal Ground
6 RXD Output
7 DSR Output
8 Not used
DB9 Adapter Plug
98-16055a
8-Pin
Plug
Ethernet
Cable
Pin #1
Pin #8
14
H The Ethernet interface connector uses an 8-pin, non-keyed modular plug.
Use shielded twisted-pair CAT5 or better cables.
To connect a Hotwire 6321 IDSL Router to an Ethernet hub or a Hotwire 6322
IDSL Router to a PC with an Ethernet NIC card installed, use the
straight-through connection.
8-Pin Straight-Through Connection
Pin # Function
1 10/100BaseT TX D+
2 10/100BaseT TX D
3 10/100BaseT RX D+
4 & 5 Not used
6 10/100BaseT RX D
7 & 8 Not used
To connect a Hotwire 6321 IDSL Router to a PC with an Ethernet NIC card
installed or a Hotwire 6322 IDSL Router to an external hub, use an Ethernet
crossover cable.
10/100BaseT TX D+
10/100BaseT TX D
10/100BaseT RX D+
Not Used
Not Used
10/100BaseT RX D
Not Used
Not Used
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
10/100BaseT TX D+
10/100BaseT TX D
10/100BaseT RX D+
Not Used
Not Used
10/100BaseT RX D
Not Used
Not Used
Function Pin # FunctionPin #
8-Pin Ethernet Crossover Cable
99-16518
Pin #1/2 = Orange/White
Twisted Pair
Pin #3/6 = Blue/White
Twisted Pair
15
Optional Hotwire 6321/6322 IDSL Router Wall Placement
The Hotwire 6321/6322 IDSL Router is designed for tabletop placement. The IDSL
router can also be mounted on a wall. To mount the IDSL router, you will need:
-
Three slotted-head #6 self-threading screws with molly bolts
-
Drill and 3/16 drill bit for the molly bolts
-
Screwdriver
A template with the dimensions for the three screws is provided. See IDSL Router
Hardware Template on page 16.
" Procedure
To mount the IDSL router:
1. Use a drill to install the plastic anchors (molly bolts).
2. Use a screwdriver to install the screws. Do not install the screws flush with the
wall. Leave enough clearance to hang the IDSL router housing from the screws.
Wall
Fasteners
99-16170-02
16
IDSL Router Hardware Template
Front
(LEDs)
98-16171
5.43"
7.55"
To Bottom
Hole
17
Hotwire 6321/6322 IDSL Router Technical Specifications
Item Specification
*
Height x Width x Depth
1.43 x 6.00 x 8.75 (3.64 cm x 15.24 cm x 22.23 cm)
Weight 1 lb. 1 oz. (0.48 kg)
External Power Supply
Class 2 Transformer normal
service input voltage range
Input: 100 Vac (+10%), 50 Hz;
120 Vac (+
10%), 60 Hz; or
230 Vac (+
10%), 50/60 Hz
Output: 18 Vdc nominal at 0.8A
Unit Power Consumption H Model 6321: 5 watts (nom)
H Model 6322: 8 watts (nom)
Approvals
FCC Part 15
Safety Certifications
Class B Subpart B digital device
Refer to equipments label for approvals on product.
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
32°F to 104°F (0°C to 40°C)
4°F to 158°F (20°C to 70°C)
5% to 95% (noncondensing)
Withstands normal shipping and handling
Interface Connectors
DSL Interface
Console Interface
Ethernet Type II Frame
RJ11 6-pin
8-pin
10/100BaseT 8-pin
H Model 6321: One Ethernet connector
H Model 6322: Four Ethernet connectors
*
Technical Specifications subject to change without notification.
18
!
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
4. Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous high voltage points or other risks. Refer all servicing
to qualified service personnel.
5. General purpose cables are used with this product for connection to the network.
Special cables, which may be required by the regulatory inspection authority for
the installation site, are the responsibility of the customer. Use a UL Listed, CSA
certified, minimum No. 24 AWG line cord for connection to the Digital Subscriber
Line (DSL) network.
6. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
8. Input power to this product must be provided by one of the following: (1) a UL
Listed/CSA certified power source with a Class 2 or Limited Power Source (LPS)
output for use in North America, or (2) a certified transformer, with a Safety Extra
Low Voltage (SELV) output having a maximum 240 VA available, for use in the
country of installation.
9. In addition, since the equipment is to be used with telecommunications circuits,
take the following precautions:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone
line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Avoid using a telephone (other than a cordless type) during an electrical
storm. There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
19
Canada EMI Warnings
!
WARNING:
To Users of Digital Apparatus in Canada:
This Class B digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.
Declaration of Conformity
This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2
and 15 of the Federal Communications Commissions Rules. This compliance
information statement pertains to the following products:
Trade Name: Hotwire
Model Numbers: 6321-A1-200 & 6322-A1-200
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
The name, address, and telephone number of the responsible party is given below:
Paradyne Corporation
8545 126th Avenue North
Largo, FL 33773-1502
Phone: (727) 530-2000
The authority to operate this equipment is conditioned by the requirement that no
modifications will be made to the equipment unless the changes or modifications are
expressly approved by Paradyne Corporation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
H Reorient or relocate the receiving antenna.
H Increase the separation between the equipment and receiver.
H Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
H Consult the dealer or an experienced radio/TV technician for help.
20
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
H Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty at www.paradyne.com/warranty.)
H Telephone: Call our automated system to receive current information by fax or to
speak with a company representative.
Within the U.S.A., call 1-800-870-2221
Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.
Trademarks
Hotwire is a registered trademark of Paradyne Corporation. All other products and
services mentioned herein are the trademarks, service marks, registered trademarks,
or registered service marks of their respective owners.
*6321-A2-GN10-00*
*6321A2GN1000*
Copyright E 2000 Paradyne Corporation. Printed in U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Paradyne 6301 Installation guide

Category
Routers
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI