Xtreme XC-22A User & Installation Manual

Type
User & Installation Manual

This manual is also suitable for

Xtreme XC-22A is a portable air conditioner that provides efficient and precise cooling, humidity control, and fan-only ventilation modes, making it an ideal solution for spot cooling large areas where cooling an entire area is impractical or impossible.

Xtreme XC-22A is a portable air conditioner that provides efficient and precise cooling, humidity control, and fan-only ventilation modes, making it an ideal solution for spot cooling large areas where cooling an entire area is impractical or impossible.

XtremeCooling
PortableAirConditioners
Models:XC14A,XC22A,XC30A
Users&InstallationManual
XtremePowerConversion®(XPC)Corporation 
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page24 XtremePowerConversion®(XPC)Corporation
TableofContents
IMPORTANTSAFETYINSTRUCTIONS..............................................4
INTRODUCTION......................................................................................6
PRODUCTDESCRIPTION......................................................................6
ASSEMBLY.................................................................................................7
ComponentParts
PowerCordHolder
RubberStoppers
DischargeDucts/SupplyAirDuct
INSTALLATIONGUIDE..........................................................................9
MovingtheUnit
PluggingintheUnit
OPERATION...........................................................................................11
ControlPanel
MAINTENANCE.....................................................................................12
FilterCleaning
SpringReplacement
TROUBLESHOOTING..........................................................................15
AlarmCodes
TroubleshootingChart
SPECIFICATIONS..................................................................................18
SHIPPINGLIST......................................................................................19
OBTAININGSERVICE..........................................................................20
XTREMEPOWERCONVERSION
®
(XPC)CORPORATION
LIMITEDWARRANTY.........................................................................21
OPTIONS.................................................................................................23
AmbientAirAdaptor
CoolingHoseAssembly
TemperatureSensorLine

RemoteControl
PumpKit
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page2 XtremePowerConversion®(XPC)Corporation
OPTIONS
AmbientAirAdaptor
CoolingHoseAssembly
ExhaustFlanges
TemperatureSensorLine
RemoteControl
PumpKit
XtremePowerConversion®(XPC)CorporationPage23
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Thank you for selecting this Xtreme Cooling unit. It provides you
with spot cooling for large areas where cooling of an entire area is
not practical or possible. Please read this manual before installing
theXC14A,XC22A,orXC30Aasitprovidesimportantinformation
that should be followed during installation and maintenance of the
Portable Air Conditioner, allowing you to correctly set up your
system for the maximum safety and performance. Included is
informationoncustomersupportandservice,ifitisrequired.Ifyou
experience a problem with the UPS, please refer to the
Troubleshootingsectioninthismanualtocorrecttheproblem.Ifthe
problem is not corrected, please collect information so that the
TechnicalSupportpersonnelcanmoreeffectivelyassistyou.
XtremePowerConversion®(XPC)CorporationPage3
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
shown in the user documentation or via support provided by XPC
Corporationpersonnelorauthorizedagents.
This warranty shall be void if (a) the equipment is repaired or
modified by anyone other than XPC Corporation or a XPC
Corporationapprovedthirdparty;(b)theequipmentisdamagedby
the customer, is improperly used or st ored, is subjected to an
adverseoperating environment,oris operatedoutside thelimitsof
its electrical specifications; or (c) the equipment has been used or
stored in a manner contrary to the equipment’s operating manual,
intended use or other written instructions. Any technical advice
furnished by XPC Corporation or a XPC Corporation authorized
representative before or after delivery with regard to the use or
application of XtremePowerConversionequipmentisfurnished on
the basis that it represents XPC Corporations best judgment under
thesituationandcircumstances,butitisusedattherecipient’ssole
risk.
EXCEPT AS STATED ABOVE, XPC Corporation DISCLAIMS ALL
WARRANTIES,EXPRESSEDORIMPLIED,INCLUDINGWARRANTIESOF
MERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE.
EXCEPT AS STATED ABOVE, IN NO EVENT WILL XPC Corporation BE
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme
Power Conversion EQUIPMENT, including but not limited to, any
costs, lost profits or revenue, loss of equipment, loss of use of
equipment, loss of software, loss of data, cost of substitutes, or
claims by third parties..Purchaser’s sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Xtreme
Power Conversion equipment, and the only obligation of XPC
Corporationunderthis warranty,shallbe therepairorreplacement
of defective equipment, components, or parts; or, at XPC
Corporations sole discretion, refund of the purchase price or
substitutionofanequivalentreplacementproduct.
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page22 XtremePowerConversion®(XPC)Corporation
IMPORTANTSAFETYINSTRUCTIONS:
(SAVETHESEINSTRUCTIONS)
Please read this manualc arefullyfor instructions on correct installation
andusage.Pleasereadallsafetyinstructions.
1. Transportandstoretheunitinanuprightpositiononly.Leavetheunit
inanuprightpositionforatleast3hoursbeforeuse.
2. Alwaysplacetheunitonaneven,levelsurface.
3. Ensure the unit is connected to a grounded utility of the correct
rating/capacity.
4. Theunitwillcoolwhentheroomtemperatureisbetween64.4°F‐113°
F(18°C‐45°C)dependingonthethermostatsetting.
5. DONOT use this unit for functions otherthan those described in this
User’sManual.
6. DONOTtilttheunit.
7. DONOTcoverorobstructtheunit’sinletand/oroutletgrilles.
8. DONOTusetheunitinareaswhereitwillbeexposedtorainorwater.
9. NEVERunplugtheunitwhileitisoperating
10.DONOTplaceanyforeignobjectsontheunit.
11.DONOToperatetheunitwithwetordamphands.
12.DONOTallowchemicalsubstancestocomeincontactwiththeunit.
13. DONOToperatetheunitinthepresenceofflammablesubstances or
vaporssuchasalcohols,pesticides,gasoline,etc.
14. DO NOT use the plug to start or to stop the unit. Always use the
controlpanelto
startandtostoptheunit.
15. Always turn off the unit when it is not in use, and unplug the power
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page4 XtremePowerConversion®(XPC)Corporation
2. Includealetterwithyourname,address,daytimephone
number, RMA number, a copy of your original sales
receipt,andabriefdescriptionoftheproblem.
3. Mark the RMA number on the outside of all packages.
Xtreme Power cannot accept any package without the
RMAnumbermarkedontheoutsideoftheboxes.
4. Return the Xtreme Cooling unit by insured, prepaid
carriertotheaddressprovidedbytheTechnician.
RefertotheWarrantystatementsinthismanualforadditional
detailsonwhatiscovered.
XTREMEPOWERCONVERSION
®
(XPC)
CORPORATIONLIMITEDWARRANTY
Xtreme Power Conversion (XPC) Corporation warrants Xtreme
Power Conversionequipment,when properly applied andoperated
withinspecifiedconditions,againstfaultymaterialsorworkmanship
for a period of one year for Xtreme Cooling unit from the date of
purchase.ForequipmentsiteswithintheUnitedStatesandCanada,
thiswarrantycoversrepairorreplacement,atthesolediscretionof
XPC Corporation. The customer is responsible for the costs of
shippingthedefectiveproducttoXPCCorporation.XPCCorporation
will pay for ground shipment of the repaired or replacement
product.Thiswarrantyappliesonlytotheoriginalpurchaser.
If equipment provided by XPC Corporationisfoundto be Deadon
Arrival (DOA), XPC Corporation will be responsible for the costs of
shippingproducttoandreturningequipmentfromthecustomerina
timely manner as agreed to with the customer, once the customer
hasrequestedandreceivedaReturnMaterialAuthorization(RMA)
number. DOA equipment is defined as equipment that does not
properly function according to user documentation when initially
received and connected in conjunction with proper procedures as
XtremePowerConversion®(XPC)CorporationPage21
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
WARNING
DONOTusertheunitinwetenvironments,suchasa
laundryroom,toavoidriskofelectricalshock
WARNING
DONOToperatetheunitinexplosiveorflammable
environments
plugfromtheelectricaloutlet.
16. Always turn the unit off and unplug the main power plug from the
electricaloutletbeforecleaning,moving,orperformingmaintenance.
17. AVOIDtheuseofadapterplugsorextensioncords.Ifitisnecessaryto
use ane xte nsion cord or an adapter plugto
operatetheunit, ensure
thattheyarecorrectlyratedfortheapplication.Consultlocalqualified
electrician and all local electrical codes to ensure proper setup. Any
extension cord usedwith the devicemust be ratedfor a minimum of
15A.
18. DO NOT unplug the unit by pulling on the
electrical cord. Keep the
electrical cord away from heat sources and always completely unroll
thecordtoavoidoverheating.Ifthepowercordbecomesdamaged,a
qualified service agent, qualified electrician, or similarly qualified
personmustreplaceit,inordertoavoidahazardorshock.
19.Thefiltersmustbeusedwiththepro ductatalltimes.Whenthefilters
areremovedforcleaning,alwaysensurethattheunithasbeenturned
offandunpluggedfromtheelectricaloutlet.
20.Regularly clean the filters to maintain efficiency. If the filters are not
cleaned regularly, the units output performance and efficiency will
declineandenergyconsumptionwillincrease.
21.DONOT operatetheunit withadamaged powercordorplug,afterit
malfunctions,oriftheunithasbeendroppedordamaged.
22.Only use the unit in the upright position on a even, flat surface. Unit
mustbepositionedatleast24inches(60cm)fromthenearestobject
inanydirection.
23.Stop operation immediately if abnormal noise or odor is noticed.
Contactlocalservicecenter.
XtremePowerConversion®(XPC)CorporationPage5
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
OBTAININGSERVICE
IftheXtremeCoolingunitrequiresService:
1. Usethe TROUBLESHOOTINGsectioninthismanual to eliminate
obviouscauses.
2. Verifytherearenocircuitbreakerstripped.
3. Callyourdealerfor assistance. If you cannot reach your dealer,
or if they cannot resolve the problem, call Xtreme Power
Conversion Corp Technical Support at 800.582.4524. Technical
supportinquirescanalsobemadeat[email protected].Please
have the following information available BEFORE calling the
TechnicalSupportDepartment:
a. Yournameandaddress.
b. Theserialnumberoftheunit.
c. Whereandwhentheunitwaspurchased.
d. All of the model information about your XtremeCooling
unit.
e. Anyinformation on the failure, including LED’s that may
ormaynotbeilluminated.
f. A description of the protected equipment, including
modelnumbersifpossible.
A technician will ask you for the above information and, if
possible, help solve your problem over the phone. In the event
that the unit requires factory service, the technician will issue
youaReturnMaterialAuthorizationnumber(RMA).
IfyouarereturningtheXtremeCoolingunittoXtremePowerfor
service,pleasefollowtheseprocedures:
1. Pack the Xtreme Cooling unit in its original packaging. If
the original packaging is no longer available, as the
Technical Support Technician about obtaining a
replacementset ofpackagingmaterial. It isimportant to
pack the Xtreme Cooling unit properly in order to avoid
damage in transit. Never use Styrofoam beads for a
packingmaterial.
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page20 XtremePowerConversion®(XPC)Corporation
WARNING
DONOToperateaunitwithadamagedpowercord
INTRODUCTION
The information provided in this manual covers 13,200 29,000
BTU/HR Xtreme Cooling units, their basic functions, operating
procedures, options a vailable and emergency situations. It also
includes information on how to ship, store, handle, and install the
equipment. Only detailed requirements of the Cooling units are
describedherein,andinstallationmustbecarriedoutinaccordance
with this manual. Electrical installation must also carefully follow
local legislation and regulations. Only qualified personnel should
conduct these installations as failure to acknowledge electrical
hazardscouldprovetobefatal.
PRODUCTDESCRIPTION
Xtreme Cooling Portable Air Conditioners feature spot cooling for
large areas where cooling of the entire area is not practical or
possible. A dedicated spot cooling thermostat controls the unit in
this application. These air conditioners can also be used in smaller
areasforroomcooling.
A control panel provides ease of use and contains selfdiagnostic
functions and displays, showing operating modes, room and set
temperatures, and faults. If an abnormal operation occurs, a visual
displayofthefaultisshown.
Casterwheelsareincludedforeaseofportability.
Suitable applications include: factory or work place, industrial
kitchen,computerroom,emergencycooling,outdoorevent,etc.
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page6 XtremePowerConversion®(XPC)Corporation
SHIPPINGLIST
 (1)PORTABLECOOLINGUNIT
 (1)User’sandInstallationManual
 (1)POWERCORDHOLDER
 (4)RUBBERSTOPPERS
 DISCHARGE/SUPPLYAIRDUCTS
(1)XC14A
(2)XC22A
(3)XC30A
XtremePowerConversion®(XPC)CorporationPage19
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
ASSEMBLY
ComponentParts
Figure1FrontandRightSideView
Figure2RearandLeftSideView
XtremePowerConversion®(XPC)CorporationPage7
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Specifications
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Page18 XtremePowerConversion®(XPC)Corporation
Specification Unit XC-14A XC-22A XC-30A
Cooling Capacity BTU/HR 13,200 21,000 29,000
Power Supply
PHASE Single Single Single
VOLTS 115 208 / 230 208 / 230
HERTZ 60 60 60
Size (W x D x H) INCHES
17.5 x 19.9 x
43.3
22.0 x 24.4 x
50.4
22.0 x 24.4 x
50.4
Weight LBS 132 198 209
Current
Consumption
AMPS 11.5 11.0 / 10.0 15.0 / 14.0
Circuit Breaker
Size
AMPS 15 15 20
Power
Consumption
KW 1.4 2.3 3.1
Compressor Input KW 1.2 2.0
2.4
Air Flow (High/
Low) Evaporator
CFM 357 / 285 464 / 393 571 / 500
Air Flow
Condenser
CFM 610 857 1142
Motor Input (High/
Low) Evaporator
KW 0.091 / 0.089 0.24 / 0.20 0.13 / 0.11
Motor Input
Condenser
KW 0.08 0.26 0.24
Air Filter
Aluminum
Aluminum /
Vinyl chloride
Aluminum /
Vinyl chloride
NEMA Plug TYPE 5-15P 6-15P 6-20P
Power Cord
Gauge
AWG 10 10 10
Power Cord
Length
FT 10 10 10
Refrigerant
TYPE R410A R410A R410A
OZ 15.9 42.3 39.9
Operating
Conditions
°F 64-113 64-113 64-113
Hot Air Duct
Diameter
INCHES 12 16 16
Maximum Duct
Length
FT 30 30 30
PowerCordHolder
1. RemovethePowerCordHolder
fromtheaccessorybox
2. PlacethePowerCordHolderon
therearoftheunitas
showninFigure3
3. UsescrewstoinstallthePower
CordHoldertotherearoftheunit
(screwsinsidetheaccessorybox)
Figure3PowerCordHolderattachment
RubberStoppers
1. RemovetheRubberStoppers
fromtheaccessorybox
2. PlacetheRubberStopperson
therearoftheunitasshownin
Figure4
3. Usescrewstoinstallthe
RubberStopperstotherearof
theunit(screwsinsidethe
accessorybox)
Figure4RubberStopperattachment
Page8 XtremePowerConversion®(XPC)Corporation
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
XtremePowerConversion®(XPC)CorporationPage17
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
TroubleshootingChart
Symptom PossibleCauses CorrectiveAction
Waterleakage
Highwaterlevelin
condensatetank
Removeblockagefromdrain
hose
Removeanyobjectstuck
underneathoftheblack
panelunderthewatertank
Theunitdoesn’t
work
Checktheutilityto
verifythatpoweris
availabletotheunit
Verifythatthepower
cordisconnected
Resetthecircuitbreakerand
restarttheunit
Connectthepowercord
Nocoldairflows
fromthecoldair
outlet
Ambientaircannot
beproperlycooledif
thefilterisdirtyand
notregularlycleaned
Onlythefan
operatesfor2
minutesafterthe
unithasbeenstarted
toprotecttheunit
Theambientair
temperaturemaybe
toohigh
Cleanairfilter
Verifythat2minuteshave
passedsincetheunitwas
turnedon
Thetemperatureofthe
compressorcanbehigher
whentheambient
temperatureistoohigh.The
compressorwillnotwork
unlesstheambientair
temperatureiswithinthe
acceptableoperatingrange
oftheunit
Waterflowcanbe
heardafter
compressorshuts
off
Nocause
Commontohearcoolant
flowingafter
unitshutsoff
Alarmdisplays“FT”
withlessthanhalf
ofthecondensate
waterinthetank
Springispossibly
broken
Replacethespring
(seeMaintenancesection)
AlarmCodes
SELFDIAGNOSTICALARMCODES
Alarm
Display
Problem Cause CorrectiveAction
Frostprevention
sensorand
Abnormal
temperature
sensorvalue
Indoorheatexchanger
temperaturetoolow
TH3temperaturesensor
hasalooseorbroken
connection
Donotusetheair
conditionerifambient
temperatureislowerthan
64°F(18°C)
Contactaqualifiedservice
agent
Refrigeranthigh
pressureswitch
Blockedairfilter
Blocked/kinkedexhaust
duct
Ambienttemperatureis
toohigh
Cleanairfilter
Ensureexhaustductisnot
blocked/kinked
Donotusetheair
conditionerifambient
temperatureishigherthan
113°F(45°C)
Abnormal
temperature
sensorvalue
TH1temperaturesensor
hasalooseorbroken
connection
Contactaqualifiedservice
agent
Abnormal
temperature
sensorvalue
TH2temperaturesensor
hasalooseorbroken
connection
Contactaqualifiedservice
agent
Compressor
overloaded
Ambienttemperatureis
toohigh
Unstablevoltagesupply
Defectivecompressor
Donotusetheair
conditionerifambient
temperatureishigherthan
113°F(45°C)
Contactaqualifiedservice
agent
Replacecompressor
Condensatewater
levelalarm
Condensatetankisfull
Emptythewatertank
Afterinstallationofthe
watertank,presstheSPOT/
COOLorROOM/COOL
buttontoresumeoperation
Page16 XtremePowerConversion®(XPC)Corporation
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
XtremePowerConversion®(XPC)CorporationPage9
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
Figure5CoolAirOutlet
attachment
WARNING
DONOTusetheunitinexplosiveenvironmentsorin
areaswhereflammablegasleakagemayoccur
WARNING
DONOTusetheunitinareaswhereitwillbe
exposedtorainorwater
WARNING
DONOTusetheunitinacorrosiveatmosphere
WARNING
DONOTusetheunitabout113
F(45
C)
WARNING
DONOTinstalltheunitonunevenorslopingsurface.
Theunitmayrollortoppleoverevenifcastersare
setinthelockedposition
DischargeDucts/SupplyAir
Duct
1. RemovetheCoolAirOutletHose(s)
fromthebox
2. PlacetheCoolAirOutletHose(s)on
thefronttopoftheunitasshownin
Figure5
3. UsescrewstoinstalltheCoolAirOut
letHose(s)tothefrontoftheunit
(screwsinsidetheaccessorybox)
INSTALLATIONGUIDE
WARNINGSREGARDINGPROPERLOCATIONFORINSTALLATION
TROUBLESHOOTING
Thealarmlightisactivatedifabnormaloperationoccurs,andacode
isdisplayedonthecontrolpanel.Thecompressorandcondenserfan
motor will stop operating. The evaporator fan will continue to run
for3minutes. If thefaultisrectified within3minutes, the unitwill
resumeoperation.Ifthefault persistsformorethan3minutes,the
evaporatorfanalsostops.Thefaultmustberectifiedbeforetheunit
canresumenormaloperation.
Page10 XtremePowerConversion®(XPC)Corporation
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
XtremePowerConversion®(XPC)CorporationPage15
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
MovingtheUnit
Unlockthecastersandpushtheunitusingthesidehandlestoaflat,
levelsurfaceandsetthecaterbrakestothelockedposition.
PluggingintheUnit
Checktheprongsandsurfaceofthepowercordplugfordust/dirt.If
dustand/ordirtarepresent,wipeoffwithaclean,drycloth.
Checkthepowercord,plug,andprongsfordamageorexcessplay.
If any damage or excess play is found, contact a qualified repair
technicianoraqualifiedelectriciantoperformreplacementofrepair
ofthepowercord,plug,orprongs.
NOTE:MakesuretheACoutletisfreeofdirt,dust,oil,water,orany
otherforeignmaterial.
TheunitisequippedwithanapprovedNEMAplugconfiguration(XC
14A = 515P; XC22A = 615P; XC30A = 620P). The appropriate
outletmustbeusedforeachplugtype.
WARNING
Ifthepowercordorplugaredamaged,repairshould
onlybeperformedbyqualifiedelectrician.
WARNING
DONOTconnect/disconnectthepowercordor
attempttooperatebuttonswithwethands.This
couldresultinelectricalshock.
Page14 XtremePowerConversion®(XPC)Corporation
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
XtremePowerConversion®(XPC)CorporationPage11
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
OPERATION
ControlPanel
Figure6ControlPanel
1. POWERBUTTON
 ActivatesunitwhenPOWERBUTTONispressed.
 Fanstartsonlowspeed.
 If POWER BUTTON is pressed during operation, unit
stops.
2. BLOWERBUTTON
 ChangesfanspeedfromLOWtoHIGHwhenpressed.
3. SPOT/COOLBUTTON
 Activates compressor and begins producing cool air 2
minutesafterbuttonispressed.
 Regulates temperature based on outlet cool air
temperature.
4. ROOM/COOLBUTTON
 Activates compressor and produces cool air 2 minutes
afterbuttonispressed.
 Regulates temperature based on inlet ambient air
temperature.
closedposition.
5. Replacethecleanfilterandclosethefilterguard.
6. Tocleanthecondenserfilter,liftupontherearfilterfromthe
middlebarslightlyandthenanglethefilteroutwardsfromthe
bottomandremove.
7. Usethesamecleaningprocedureasinsteps35above.
8. Toreplacethecondenserfilter,placethetopofthefilterinthe
guideandslidethefilterupuntilthebottomofthefilterclears
theframe.Thenpushthebottomofthefilterintotheguideand
letthefiltergentlyfallinsidetheguide.
NOTE:Foreffectivecooling,cleanthefilteratleastevery2weeks.
SpringReplacement
There are two springs on the rear of the condenser water tank
guide.
1. Releasethescrewonthespringhook.
2. Take off the spring hook, and then pull out the opposite spring
hook from the hole in the condenser
watertankguide.
3. Replace with a new spring in reverse
order.
4. Repeatthesestepsfortheother
spring.
Figure9SpringReplacement
WARNING
DONOToperatewithoutthefilterinstalled
WARNING
DONOToperatetheunitwithadamagedcordor
plug,aftertheunitmalfunctions,oriftheunithas
beendroppedordamaged.
Page12 XtremePowerConversion®(XPC)Corporation
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
XtremePowerConversion®(XPC)CorporationPage13
XC14A,XC22A,XC30AUSER’SMANUALPortableAirConditioners
5. SETTEMPBUTTON
 Changetargettemperature/datavalueby±1.
 Changedatavalueby±10bypressingcontinually.
 PresstheSETTEMPBUTTONStosettemperature
 Upper button is to heighten temperature and Lower
buttonistolowertemperature.
6. ALARM
 Alarm indicator light blinks and indicates abnormal
systemoperation.
 IfAlarmoccurs,compressorstops.
 System operation stops when ALARM light is activated /
blinkinglongerthan3minutes.
7. CURRENTTEMP
 Displays current room temperature in display in
Fahrenheit(inROOMCOOLMODEonly)
 SPOT/COOLModedisplaysoutlet(coolair)temperature
duringnormaloperations.
 In order to change °F to °C, press SPOT / COOL and
ROOM/COOLbuttonstogetherfor2seconds.
 Cwillblink2timesandthefigurewillchangeto°C
 ALARM codes blink and are displayed when abnormal
operationoccurs.
8. TARGETTEMP
 DisplaystheunitsettemperatureforROOMCOOLmode
only
MAINTENANCE
FilterCleaning
There are two filters in the unit. The evaporator filter is located at
thefrontoftheunit.Thecondenserfilterislocatedintherearofthe
unit(seeFigure9&10).
Pull the filter frame forward to
removethebackfilter.
Figure7RemovingRearFilter
 Removedustfromthefilterusing
avacuumcleanerhose
attachment.
 Ifrequired,wasthefilterin
lukewarmwaterwithamild
detergent.Leavetodryina
shadedareabeforereinstalling.
Figure8CleaningtheFilter
1. Tocleantheevaporatorfilter,pullthefrontfilterguardforward
fromthetopuntiltheguardisopen(inanangledposition)and
restingonthesupportingcables.
2. Slidethefilterupanduseavacuumcleanertoremovethedust
fromthefilter.
3. Ifthefilterisheavilycoveredwithdustanddirt,warmwaterand
mildsoaporneutraldetergentmaybeusedtowashthefilter.
Donotuseanyotherchemicalstocleanthefilter,astheywill
likelydamagethefilter.
4. Drythefilterinashadedareabeforereplacingit.Donotoperate
theunitwithoutthefilterinstalledandthefilterguardinthe
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Xtreme XC-22A User & Installation Manual

Type
User & Installation Manual
This manual is also suitable for

Xtreme XC-22A is a portable air conditioner that provides efficient and precise cooling, humidity control, and fan-only ventilation modes, making it an ideal solution for spot cooling large areas where cooling an entire area is impractical or impossible.

Ask a question and I''ll find the answer in the document