GROHE 34150003 Installation guide

Type
Installation guide
English .....1
Français .....2
Español .....3
Design + Engineering GROHE Germany
Eurosmart Cosmopolitan
Eurosmart Cosmopolitan
99.333.431/ÄM 231279/05.14
31 135
31 322 31 353
31 136
I
A
B
1
C
D
E
F
13mm
*19 017
1
6
m
m
G
2
3 4
K
L
H
H1
1
2
m
m
M
*19 332
3
2
m
m
J
M1
5
31 135
31 322
31 136
31 353
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Sirvanse pasar ese instrucción al utilizador de la grifería!
Please pass these instructions on to the end user of the fitting!
1
English
Application
Operation is possible in conjunction with:
Pressurized storage heaters
Operation is not possible with:
Low-pressure storage heaters (displacement water heaters)
Specifications
Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure reducing valve
Operating pressure max. 145 psi
Test pressure 232 psi
Max. flow: 6.6 L/min or 1.75 gpm/ 60 psi
Temperature
Hot water inlet: (maximum) 176 °F
Recommended: 122°F-140 °F
Handle rotation stop available for 31 136/31353
(order No. 46 308)
Water connection cold - RH hot - LH
Deck thickness max. 2 3/8"
Non reversible cartridge
Notes:
- Major pressure differences between hot and cold water
supply should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable
appliances.
Installation
Flush piping system prior and after installation of faucet
thoroughly!
Prepare sink faucet
Refer to the dimensional drawing on fold-out page I.
31 135/31 353: Fit escutcheon (A) with mounting set (B),
see fold-out page I, Fig. [1].
Mount sink faucet, see fold-out page I, Figs. [2] and [3].
1.Fit O-Ring (C) and insert faucet into sink.
2.Fit brace (D), if necessary, with seal (E), retaining ring (F)
and connect nut (G).
Note:
If brace (D) is omitted, deck thickness can be increased
by 9/16" to a total of 2 3/8".
Mount handspray, see Fig. [3] and [4].
1.Insert spray holder (H) through the hole, aligning the
seal (H1) with the groove on the flange.
2.Tighten spray holder (H) with mounting set (J).
3.Loosely screw handspray (K) onto spray hose (L).
4.Insert spray hose (L) complete with handspray (K) through
the spray holder (H) from above.
5.Connect spray hose (L) with nipple (M1) to swivel
connection (M) of the spout body.
6.Tighten spray hose (L) with handspray (K) facing to front.
Connect sink faucet, see Figs. [2] and [3].
Open hot and cold-water supply and check connections
for leakage!
Check fitting for correct operation, see Fig. [5].
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate. The
highest possible flow rate is set by the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
For commissioning see “replacing the cartridge”
point 1 to 3, and Figs. [6] and [7] or [8] and [9] on fould-out
page III.
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off hot and cold water supply!
I.Replacing the cartridge, see Fig. [6] or [8].
1.Lever out plug (N).
2.Remove set screw (O) using a 3mm socket spanner and pull
off lever (P).
3.Unscrew cap (Q).
4.31 135/31 322: Remove connection nut (R) and detach
complete cartridge (S).
31 136/31 353: Remove screws (R) and detach complete
cartridge (S)
5.Replace complete cartridge (S).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves on
the housing.
31 135/31 322: Tighten screw coupling until it turns freely.
31 136/31 353: Fit screws (R) and tighten evenly and
alternately.
II. Check valve (only for 31 136/31 353), see Fig. [8].
1.Proceed as for replacing the cartridge, points 1 to 4.
2.Pull off and replace check valve (T).
III. Diverter (only for 31 136/31 353), see Fig. [8].
1.Proceed as for replacing the cartridge, points 1 to 4.
2.Pull off spout (U).
3.Pull out locking ring (V).
4.Pull out the diverter (W).
IV. Unscrew and clean flow control (13 928/48 251),
see fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
www.grohe.com
2013/10/22
D
&
+49 571 3989 333
A
&
+43 1 68060
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
CDN
&
+1 888 6447643
CH
&
+41 448777300
CN
&
+86 21 63758878
CY
&
+357 22 465200
CZ
&
+420 277 004 190
DK
&
+45 44 656800
E
&
+34 93 3368850
EST
&
+372 6616354
F
&
+33 1 49972900
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
GR
&
+30 210 2712908
H
&
+36 1 2388045
HK
&
+852 2969 7067
I
&
+39 2 959401
IND
&
+91 124 4933000
IS
&
+354 515 4000
J
&
+81 3 32989730
KZ
&
+7 727 311 07 39
LT
&
+372 6616354
LV
&
+372 6616354
MAL
&
+1 800 80 6570
N
&
+47 22 072070
NL
&
+31 79 3680133
NZ
&
+09/373 4324
P
&
+351 234 529620
PL
&
+48 22 5432640
bLuro@gr
ohe.com.pl
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
UA
&
+38 44 5375273
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL
HR
KS
ME
MK
SLO
SRB
&
+385 1 2911470
Eastern Mediterranean,
Middle East - Africa
Area Sales Office:
&
+357 22 465200
IR
OM
UAE YEM
&
+971 4 3318070
Far East Area Sales Office:
&
+65 6311 3600
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GROHE 34150003 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document