Engine block 1A-13
Power Generator and Starter
Power Generator’s
Dismantling/Mounting
Warning
When dismantling /mounting the power
generator on the complete vehicle, the
accumulator cable shall be dismantled firstly,
or the power generator’s Terminal B will
contact the vehicle body, which will lead to
sparks and further result in personal injury
and electric element damage.
1. Dismantle the power generator according to
the sequence illustrated in the figure.
2. Mount the power generator according to the
sequence reverse to the dismantling process.
3. Inspect the belt’s deflection /tension (see
Inspection of the Power Generator Belt).
Explanations on Inspection of Power
Generator Belt
If necessary, inspect the power generator belt’s
deflection and tension: see complete vehicle
maintenance manual’s corresponding part.
Explanations on adjustment to tension of
power generator and air conditioning
drive belts
1. Loosen the power generator’s bolt nut . ①
2. Loosen the power generator’s fixing nut . ②
Use the adjusting bolt , ③ and adjust the belt
tension and belt difference to the specified value.
3. Tighten the power generator pivot bolt’s nut
: tightening ① torque:43~60N·m
4. Tighten the power generator’s fixing nut ②:
tightening torque:37.3~52N·m
Notice
If mounting the new power generator belt or
running power generator belt for less than 5
minutes, adjustment shall be made according
to the new part’s standard value.
If running power generator belt for more than
5 minutes, adjustment shall be made
according to old part’s standard value.
If it fails to stay within the standard value,
readjustment shall be made from Step 1 on.
Explanations on inspection of power
generator
1. Confirm if the accumulator has been charged.
2. Confirm if the belt’s deflection /tension stays
within the specified range (See power
generator part: Inspection of Power Generator
Belt).
3. Turn the ignition switch to the “ON” position,
and the charge warning lamp will turn on.
4. Confirm if the charge warning lamp is off
after the engine has been put into running.
★ Note: If there is abnormal situation, see
corresponding “Complete Vehicle Fault
Diagnosis and Handling”.
Starter Dismantling/Mounting
Warning
When dismantling/mounting the starter on the
complete vehicle, if the accumulator’s
positive cable fails to be loosened, the
starter’s Terminal B will connect with or
contact the body, which will lead to sparks
and further result in personal injury and
electric element damage. Due to this,
accumulator’s positive cable shall be
dismantled firstly when the following
operations are conducted:
1. Dismantle the accumulator’s positive cable.
2. Dismantle the starter according to the
②Power
Generator Belt
④Power
Generator
③Adjust the bolt
②power generator’s
fixing nut power
①generator’s bolt nut