Time Delay Settings
S: Second
M:Minute
H:Hour
Sensitivity Control Area
Preset Functons
Hold Time : 5 Minutes
Mode : Night
All Day
Light Sensor
No Function
(Disable Sensor)
Night
Flash
SOS Optical Signal
OFF
Photocell
Microwave
Sensor
ON
Light Sensor Mode: Light will operate via Photocell once light level is 30 Lux.
Night Mode: Light will operate upon presence detection only when the light
level is below 30 Lux.
Flash Mode: Light will flash repeatedly.
SOS Mode: Light will flash in SOS distress pattern
FLOODLIGHT PROGRAMMER INSTRUCTIONS
DOC REV 3:
30/11/2017
All Day Mode: Light will operate upon presence detection inside detection
area.
Picture Mode
Floodlight Programmer can only operate within 0.5M of tting.
Sensitivity : 75%
IMPORTANT INFORMATION
•The standard warranty offered with these LED products as displayed at www.venturelightingeurope.com/technical-centre/warranty
can only be upheld providing the following instructions and conditions of use are strictly adhered to. Venture Lighting will not be held
responsible for any claims resulting from inadequate installation and therefore advice may be required from a qualied person before
proceeding.
• For specic details regarding Luminaires, Drivers and Accessories, refer to the units label, box / carton label, visit www.
venturelightingeurope.com or call our ofce +44(0)1923 692 600.
• Venture LED products, although robust and sturdy, should be treated with care. A dropped unit may sustain internal damage and
must be discarded. Generally, products cannot be serviced; there are no serviceable parts inside and the product should not be
opened unless instructed below to enable electrical connection or mechanical xing.
• IP54 and above rated units are suitable for exterior applications, otherwise products are only suited for indoor applications in dry
environments.
• Class II products are double insulated and must not be connected to earth. Class III products provide a SELV output.
• The indicated case temperatures of the installed products must not be exceeded; ensure adequate ventilation and do not cover. If
used in hot environments relevant tests must be carried out prior to installation.
• For DALI, emergency products or external drivers refer to their individual product sheets.
• Please understand the following instructions and installation procedure before proceeding. Work should be carried out by a qualied
electrician.
• The product must be electrically connected as indicated on the units label to live and neutral (disconnecting or isolating the supply
prior) and earth (except Class II). Fuse accordingly, taking into account units input current shown on the label noting that MCBs must
be rated to handle the combined inrush current of all connected devices. Product with wire leads are not supplied with a terminal
block; use a 5A 250V connector.
INSTALLATION
• Installation to be undertaken only by qualied personnel. Disconnect all power before beginning work.
• Do not operate the luminaire if the glass is broken or cracked.
• If the external exible cable of this luminaire is damaged it must be replaced by the manufacturer or a similar qualied person.
• The light source in this luminaire is not replaceable. When the luminaire reaches its end of life the whole luminaire must be replaced.
FLD086 / 087 / 088 / 089/ /090
INSTALLATION INSTRUCTIONS & CONDITIONS OF USE
Email: [email protected] Phone: +44 (0) 1923 692600 Web: www.venturelightingeurope.com
DOC REV 3:
30/11/2017
Floor Mounted Ceiling Mounted Wall Mounted
PART NO. WEIGHT DIMENSIONS WxLxH L1 L2 dWINDAGE
FLD086 4.1Kg 382 x 306 x 86mm
151mm
31mm 11mm 0.12m²
FLD087/88 6.18Kg 500 x 415 x 100mm
185mm
40mm 12mm 0.21m²
FLD089/90 11.4Kg 610 x 470 x 122mm
240mm
40mm 13mm 0.29m²
IMPORTANT INFORMATION
•The standard warranty offered with these LED products as displayed at www.venturelightingeurope.com/technical-centre/warranty
can only be upheld providing the following instructions and conditions of use are strictly adhered to. Venture Lighting will not be held
responsible for any claims resulting from inadequate installation and therefore advice may be required from a qualied person before
proceeding.
• For specic details regarding Luminaires, Drivers and Accessories, refer to the units label, box / carton label, visit www.
venturelightingeurope.com or call our ofce +44(0)1923 692 600.
• Venture LED products, although robust and sturdy, should be treated with care. A dropped unit may sustain internal damage and
must be discarded. Generally, products cannot be serviced; there are no serviceable parts inside and the product should not be
opened unless instructed below to enable electrical connection or mechanical xing.
• IP54 and higher rated units are suitable for exterior applications, otherwise products are only suited for indoor applications in dry
environments.
• Class II products are double insulated and must not be connected to earth. Class III products provide a SELV output.
• The indicated case temperatures of the installed products must not be exceeded; ensure adequate ventilation and do not cover. If
used in hot environments relevant tests must be carried out prior to installation.
• For DALI, emergency products or external drivers refer to their individual product sheets.
• Please understand the following instructions and installation procedure before proceeding. Work should be carried out by a qualied
electrician.
• The product must be electrically connected as indicated on the units label to live and neutral (disconnecting or isolating the supply
prior) and earth (except Class II). Fuse accordingly, taking into account units input current shown on the label noting that MCBs must
be rated to handle the combined inrush current of all connected devices. Product with wire leads are not supplied with a terminal
block; use a 5A 250V connector.
INSTALLATION
• Installation to be undertaken only by qualied personnel. Disconnect all power before beginning work.
• Do not operate the luminaire if the protective shield is damaged.
• If the external exible cable of this luminaire is damaged it must be replaced by the manufacturer or a similar qualied person.
• The light source in this luminaire is not replaceable. When the luminaire reaches its end of life the whole luminaire must be replaced.
FLD083-SI / FLD084-SI / FLD085-SI
INSTALLATION INSTRUCTIONS & CONDITIONS OF USE
PART NO. WEIGHT DIMENSIONS WxLxH L1 L2 dWINDAGE
FLD083-SI 0.4Kg 168 x 110 x 18.5mm
76mm
11.6mm 5.5mm 0.02m²
FLD084-SI 0.55Kg 214 x 140 x 18.5mm
76mm
11.6mm 5.5mm 0.03m²
FLD085-SI 1.8Kg 317 x 217 x 28.3mm
180mm
14.7mm 6.2mm 0.066m²
Email: [email protected] Phone: +44 (0) 1923 692600 Web: www.venturelightingeurope.com
DOC REV 3:
30/11/2017
Ceiling Mounted Wall Mounted Floor Mounted
  • Page 1 1
  • Page 2 2
  • Page 3 3

VENTURE LIGHTING FLD088 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI