Viso Systems LabSpion User manual

Type
User manual

Viso Systems LabSpion is an innovative far-field goniometer system that combines a spectrometer sensor and user-friendly software to deliver fast and precise photometric measurements. With its ability to measure all light sources and provide accurate data, the LabSpion is an ideal tool for lighting professionals seeking reliable and efficient measurement solutions. The system's versatility extends to various applications, including luminaire testing, lamp characterization, color rendering index evaluation, and spectral power distribution analysis.

Viso Systems LabSpion is an innovative far-field goniometer system that combines a spectrometer sensor and user-friendly software to deliver fast and precise photometric measurements. With its ability to measure all light sources and provide accurate data, the LabSpion is an ideal tool for lighting professionals seeking reliable and efficient measurement solutions. The system's versatility extends to various applications, including luminaire testing, lamp characterization, color rendering index evaluation, and spectral power distribution analysis.

LabSpion
Patent pending
User guide
Preliminary edition
Last edited: 2014-04-22
© 2007 Viso Systems ApS, Denmark
All rights reserved. No part of this manual may be reproduced, in any form or by any means,
without permission in writing from Viso Systems ApS, Denmark.
Information subject to change without notice. Viso Systems ApS and all affiliated companies
disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss
or any other loss occasioned by the use of, inability to use or reliance on the information
contained in this manual.
Dimensions
190cm
162,5cm
80cm
45cm
122cm
150cm
Maximum lamp length
8cm C-plane base height
65cm
3 LabSpion user guide
Sensor distance L
Measurement method: Far Field
D
L = 10 x D
Please note the sensor distance to the lamp must be minimum 10 x
the diameter of the lamp.
The Far Field measurement method requires this distance for
accurate measurement data.
4 LabSpion user guide
Weight
15 Kg
25 Kg
16 Kg
2 Kg
3 Kg
LabSpion weight
56 Kg
LabSensor weight
5 Kg
Total shipping weight: 69 Kg
Packages: 4 pcs
Total weight: 63 Kg
Shipping packages
1. C-Plane goniometer 140x50x15cm 17Kg
2. LightSpion base 50x50x20cm 27Kg
3. 3 point base table 140x50x15cm 19Kg
4. Sensor + tripod 100x35x35cm 6Kg
Shipping dimensions
Shipping weight
5 LabSpion user guide
Contents
Introduction ........................................................................ 8
About the LabSpion ........................................................ 8
System content .............................................................. 8
About this document ....................................................... 9
Installation ....................................................................... 10
Software installation ..................................................... 10
Connecting power ........................................................ 11
Connecting USB ........................................................... 12
Connecting LabSensor ................................................. 13
Connecting C-plane goniometer ................................... 14
Connecting lamp power ................................................ 15
Connecting diagram ..................................................... 16
Making measurements ..................................................... 17
Alignment of sensor ...................................................... 17
Alignment of lamp ......................................................... 18
Quality selection ........................................................... 19
Full automatic ............................................................... 20
Manual power control ................................................... 23
Manual integration time setup ....................................... 24
Free running spectrometer ........................................... 25
Measurement data ........................................................... 26
Power details ................................................................ 29
CRI details .................................................................... 31
6 LabSpion user guide
Spherical limit ............................................................... 33
Attaching pictures ......................................................... 34
Saving measurement ................................................... 35
Exporting to IES/LDT .................................................... 36
Exporting to PDF .......................................................... 37
Exporting to PNG ......................................................... 37
Exporting to CSV .......................................................... 39
Emailing measurement ................................................. 40
Specifications ................................................................... 41
7 LabSpion user guide
Safety Information
Warning! This product is not for household use.
Read this manual before installing and operating the
controller, follow the safety precautions listed below, and
observe all warnings in this manual.
Preventing electric shocks
Always ground (earth) the power supply.
Use only a source of AC power that complies
with local building and electrical codes, and that
has both overload and ground-fault protection.
If the controller or power supply are in any way damaged,
defective, wet, or show signs of overheating, disconnect the
power supply from AC power and contact Viso Service for
assistance.
Do not install or use the device outdoors. Do not spray with
or immerse in water or any other liquid.
Do not remove any covers or attempt to repair the device or
power supply. Refer any service to Viso.
Disposing of this product
Viso products are supplied in compliance with Directive
2002/96/EC of the European Parliament and of the Council of
the European Union on WEEE (Waste Electrical and
Electronic Equipment), as amended by Directive 2003/108/EC,
where applicable.
Help preserve the environment! Ensure that this product is
recycled at the end of its life. Your supplier can give details of
local arrangements for the disposal of Viso products.
8 LabSpion user guide
Introduction
About the LabSpion
The LabSpion is a revolutionary new far field goniometer
system using a spectrometer sensor making it possible to
measure all photometric measurement fast and easily. The
Light Inspector software makes fast and easy to make, save
and export measurement data.
System content
The LabSpion package contains the following items.
LabSpion goniomtere base
C-plane goiniometer with lamp bracket
3 point base table
LabSensor
Tripod for LabSensor
Light Inspector USB stick (Windows)
5 m IEC power cord
C-Plane goniomter with
lamp bracket
LabSpion base with all
gonio drivers, power
analyser integrated
3 point base table for
LabSpion base
LabSensor with
spectrometer sensor
and integrated laser for
distance measurement
to LabSpion.
Tripod for LabSensor.
9 LabSpion user guide
5 m USB cable
20m RJ45 cat 5 for connection between LabSpion and
LabSensor
About this document
This guide describes how to install and use the LabSpion
controller, and how to make measurement of different light
sources.
10 LabSpion user guide
Installation
Software installation
Before you can start using the LabSpion, the Viso Light
Inspector software must be installed. Supported on all
windows platforms.
Use the following link to download the latest version:
http://www.lightdataserver.com/software/Viso%20Systems/Ligh
tInspector.htm
Please make sure the LabSpion is not connected to the
computer during software installation.
Run the msi file and follow the
installation instruction.
USB drivers are automatically
installed.
Your measurements are not
lost, when installing newer versions or uninstalling. All
measurements always remain in your document folder.
11 LabSpion user guide
Connecting power
The LabSpion comes with a standard IEC power in
connector and with standard euro power cable, but any
power cable can be used as the LabSpion support any
outlet voltage from 90-260VAC.
The power in connector
supplies power to the
goniometer motor and to the
power analyser and
subsequent to the light
source to be measured,
meaning that power supplied
will be identical to power
supplied to the light source to
be measured.
AC power supply cable plug
Warning: Risk of electric shock! Plug
installation shall be performed by a qualified
electrician.
A grounding-type (earthed) power plug that fits the local
power outlet must be used which you can acquire an IEC
power cable with a suitable grounding-type plug from most
consumer electronics stores.
When installing the plug connect pins as follows:
yellow and green wire to ground (earth)
blue wire to neutral
brown wire to live
12 LabSpion user guide
Connecting USB
The LabSpion is connected to the computer using a USB
connector type B. A 2m USB cable type A to B is included
with the LabSpion but any USB cable supporting USB2.0
can be used.
The USB supplies
communication and power to the
LabSpion’s main board
processor, power analyser and
photo spectrometer, meaning
that the photo spectrometer can
be used only with USB
connected.
After connecting USB start the “Viso Light Inspector”
software and connection to the LabSpion will automatically
be established. A successful
connection is shown with a green
“Connected” icon in the upper
right corner of the “Viso Light
Inspector” software.
USB can be connected and disconnected without the need
of restarting the “Viso Light Inspector” software, as
connection always is established automatically as soon as
the USB connector is plugged in and vice versa.
13 LabSpion user guide
Connecting LabSensor
Connection to the LabSensor is done by using a RJ45
cable between the LabSpion base and the LabSensor. The
LabSpion supplies all power and data communications the
LabSensor via the RJ45 cable.
Warning do not connect the LabSensor to C-plane
motor connector, this could damage the LabSensor.
14 LabSpion user guide
Connecting C-plane goniometer
The C-plane goniometer is connect to the LabSpion base
via a RJ45 cable. The LabSpion will automatically detect
the C-plane goniometer.
Warning do not connect the C-plane motor to the
LabSensor connector, this could damage the LabSpion.
15 LabSpion user guide
Connecting lamp power
The LabSpion has a build in power analyser and power
switch. The power switch is used to switch of the lamp
before a measurement is made so the ambient light can be
measured and subtracted from the subsequent
measurement.
The maximum
supported lamp
current is 3A which
is 660W at 220VAC
and 330 at 110VAC.
AC power supply cable plug
Warning: Risk of electric shock! Plug
installation shall be performed by a qualified
electrician.
A grounding-type (earthed) power plug that fits the local
power outlet must be used which you can acquire an IEC
power cable with a suitable grounding-type plug from most
consumer electronics stores.
When installing the plug connect pins as follows:
yellow and green wire to ground (earth)
blue wire to neutral
brown wire to live
16 LabSpion user guide
Connecting diagram
Below is a connection diagram showing the different
connection needed to make the system operational.
Mains IN
17 LabSpion user guide
Making measurements
Alignment of sensor
Before a measurement can be made is it important place
the sensor at the correct distance and align it correctly.
The LabSpion is a so called Far Field goniometer system
meaning the distance between the sensor and the lamp is
determined by the lamp size.
The recommended distance between the sensor and the
goniometer is 10 times the lamp length/diameter.
The distance can easily be measured using the build-in
laser in the LabSensor.
IMPORTANT !! The distance should be measured to the
centre of rotation of LabSpion base goniometer, use the
centre stick as laser target.
Use ”Alignment stick”
Centre of rotation
Laser Distance >= lamp length x10 (minimum x8)
18 LabSpion user guide
Alignment of lamp
Before making a measurement is it necessary to align the
lamp to be measured to the centre of rotation.
By loosening the 4
screws on the C-Plane
goniometer can it be
slide to adjust the lamp
into the centre position.
The 4 finger screws are placed in pairs on each side of the
C-Plane goniometer as shown below.
Centre of
rotation
Finger screws
19 LabSpion user guide
Quality selection
Before making a measurement is it possible to select the
measurement quality by clicking on Setup->Measurement
quality.
As default does the “Viso Light Inspector” use the “low
resolution”. It is possible
to select 3 levels: low,
medium and high. Each
quality level increases
the number
measurements made during goniometer measurements and
also increases the photo spectrometer integration time
lowering noise level of photo spectrometer measurements.
Increasing the quality results in substantial extended
measurement time.
20 LabSpion user guide
Full automatic
By default does the “Viso Light Inspector” software make
full automatic measurement, meaning adjusting photo
spectrometer to the background light environment by
turning off the light source and measuring the background
light levels which subsequent is subtracted from
measurements so that measurements can be done even in
a lit room. The adjustment of the exposure time of the photo
spectrometer also known as integration time is also done
automatically.
A measurement is simply started by clicking on the
play icon.
Then is integration time automatically
set.
Then is the ambient light level
automatically measured by turning off
the light source.
The light source is then turned 180 degrees to prepare for
measurement.
Power is then measured and stored.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Viso Systems LabSpion User manual

Type
User manual

Viso Systems LabSpion is an innovative far-field goniometer system that combines a spectrometer sensor and user-friendly software to deliver fast and precise photometric measurements. With its ability to measure all light sources and provide accurate data, the LabSpion is an ideal tool for lighting professionals seeking reliable and efficient measurement solutions. The system's versatility extends to various applications, including luminaire testing, lamp characterization, color rendering index evaluation, and spectral power distribution analysis.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI