Alemlube SPG300-D_SPG300-R Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Alemlube SPG300-D_SPG300-R Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Description
The SPG300-D and SPG300-R refillable automatic grease lubricators dispense a precise amount of grease to single or multiple lube
points at pre-determined intervals. Powered by four AAA batteries, the SPG300-D can be installed directly and the SPG300-R can be
installed remotely utilising a bracket, 113cm of tubing and fittings (not depicted). The SPG300-D and SPG300-R refillable automatic
grease lubricators can be set to dispense 300cc of grease within a 1 month period or periods of 3, 6 or 12 months. Quick and easy
refilling can be achieved with the aid of a suitable bulk grease source (20kg grease kit) or a portable grease gun.
Specifications
Installation
Direct Install (SPG300-D)
1 Remove the grease nipple from the bearing and attach the automatic grease
lubricator directly using an 11mm spanner
2 Switch on by turning the battery cap clockwise until it locks
3 The green light should come on for a few seconds after initial start up
Remote Install (SPG300-R)
1 Attach the bracket supplied to the automatic grease lubricator using a 12mm spanner
2 Connect the automatic grease lubricator to the specified bearing grease nipple
utilising the supplied 113cm long tubing (maximum remote mount capabilities of 2
metres using your own tubing)
3 Fix the automatic grease lubricator with attached mounting bracket in the desired
position with the hardware supplied
4 Switch on by turning the battery cap clockwise until it locks
5 The green light should come on for a few seconds after initial start up
Operation Status
1 When powering the SPG up by doing up the battery cap, the green light comes on for
about 1 second to show the unit is working
2 It will complete 1 lube cycle at this time – around 10 seconds long
3 If the red light starts flashing at this time, for about 10 seconds, the batteries are
weak and should be replaced or that the back pressure is excessive and the unit is
struggling to pump – change the batteries and if the red flashing on start up
continues, check the bearing/feed line.
Changing the Batteries
1 Unscrew the yellow cap at the top of
the automatic grease lubricator and
insert the batteries as shown
Changing the Discharge Interval
1 Unscrew the yellow cap and remove the four AAA batteries
2 Using a 2.5mm Allen key, remove the top section to access
the mode setting device
Uses Automatic lubrication of single or multiple lube points
Power Supply 4 x 1.5V (AAA batteries)
Motor Power Minimum 3.02V DC / maximum 6V DC
Discharge Quantity 0.085cc per stroke
Discharge Intervals 300cc of EP#1 or EP#2 grease within a 1 month, 3 month, 6 month or 12 month period
Operating Temperature -10ºC to +50ºC
BATTERY ORIENTATION
= NEGATIVE DOWN
=
POSITIVE DOWN
12 3
12 months setting shown
1
Visit our website at www.alemlube.com.au Email - inf[email protected]
Refillable Automatic Grease Lubricator
SPG300-D
SPG300-R
NSW
TEL: (02) 9939 0711
FAX: (02) 9939 0411
QLD/PNG
TEL: (07) 3889 8480
FAX: (07) 3889 8490
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
WA
TEL: (08) 9209 3066
FAX: (08) 9209 3933
SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008