correct polarity is put. (FIGURE 3b)
3. Refit the rear cover. (FIGURE 3c)
FIGURE 3a FIGURE 3b FIGURE 3c
4. Hold the rear cover in position and mark the two mounting holes. Drill the holes,
insert the plastic wall plugs and screw the rear cover to the wall using the
screws supplied. Offer the Detector up to the rear cover using screws as
originally supplied. (FIGURE 4)
FIGURE 4
Note: After removing batteries, wait for 5 seconds to refit batteries.
Operation
1. With the tamper switch not being pressed, the unit enters test mode, which
allows the user to make a test. When the movement has been detected, the
red indicator LED on the Detector will illuminate and the load or the lamp
plugged into the On/Off Module AN135, Lamp Module AD130 will turn ON. It
implies that the unit is working properly.
Note: When the battery is connected, the LED behind the lens will be on for
about 1 minute as warming-up duration until the PIR has stabilized when the
LED turns OFF.
Time-off knob controls how long the connected load or lamp will stay on after
the motion has been detected. It is set from 5 seconds to 12 minutes. “T”
means 5 seconds, while “+” is 12 minutes. After the expiry of preset time-off, the
Detector will turn OFF the load or the lamp plugged into the On/Off Module
AN135, Lamp Module AD130. The red indicator LED on the load or the
connected lamp will be off too.
2. When the tamper switch is pressed, the unit will enter normal mode. Upon
motion being sensed, the Detector will turn ON the load or the lamp plugged
into the On/Off Module AN135, Lamp Module AD130.
After the elapse of preset time-off, the Detector will turn OFF the load or the
lamp plugged into the On/Off Module AN135, Lamp Module AD130.
In normal mode with the tamper switch being pressed, the red indicator LED on
the Detector will not illuminate to conserve battery life when the detector is
triggered, (unless the battery is low).
3. By pressing the tamper switch for more than 5 seconds, and then release it.
The Detector will send an alarm command (ALARM_REPORT, Alarm Type ==
0x01, Alarm Level == 0x11) to the Module. The load or the lamp plugged into
the On/Off Module AN135 or Lamp Module AD130 will flash for 10 seconds.
Advanced Operation
The following information is for someone that has some experience setting up a
Z-Wave system or someone that has computer software running a Z-Wave
controller.
Enabling/Disabling Power Saving Function (for testing)
When no movement has been detected for 10 seconds, the SP103 will enter the
power saving mode. It can be disabled or enabled power saving function by setting