Best WP29M User manual

Category
Cooker hoods
Type
User manual

This manual is also suitable for

WP29M SERIES
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE AND OPERATION INFORMATION ON
PAGES 10 AND 11.
V07693 rev. B
HB0058
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
!
!
In USA - BEST BY BROAN
®
P.O. Box 140, Hartford, WI 53027
In Canada - BEST BY BROAN
®
550 Lemire Blvd., Drummondville, QC, J2C 7W9
For additional information - visit www.bestbybroan.com
WARNING WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers
that may ignite. Heat oils slowly on low or medium
settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food (Crêpes Suzette, Cherries
Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner.
BE CAREFUL TO PREVENT BURNS. IF THE
FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN—You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels—This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area
where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
!
!
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes
overheated. The motor will restart when it will be
cooled down. If the motor continues to shut off and
restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom
of the hood should be at a minimum of 24” and at
a maximum of 30” above the cooking surface.
5. Two installers are recommended because of the
large size and weight of this hood.
6. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside—Do not exhaust air
into spaces within walls or ceiling or into attics,
crawl space or garage.
7. This product is equipped with a thermostat which
may start blower automatically. To reduce the risk
of injury and to prevent power from being switched
on accidentally, switch power off at service panel
and lock or tag service panel.
8. To reduce the risk of fire and electric shock, the
Best by Broan WP29M Series hood must be
installed with Best by Broan interior blower models
P6 or P12; Best by Broan exterior blower models
EB6, EB9, EB12 or EB15; Best by Broan in-line
blowers models ILB3, ILB6, ILB9, ILB11. Other
blowers cannot be substituted. (Blowers sold separately.)
9. Please read specification label on product for
further information and requirements.
HL0081
- 3 -
Model 415
(7” round adjustable elbow)
Model 427
(4
1
/2” x 18
1
/2
to 10” Round,
6” high - lateral
Model 423
(4
1
/2” x 18
1
/2” to
10” Round - vertical
Model 424
(4
1
/2” x 18
1
/2” to
10” Round - horiz.
front/rear
Model 454
(4
1
/2” x 18
1
/2
to 10” Round -
horiz. /right
Model 453
(4
1
/2” x 18
1
/2
to 10” Round -
horiz. /left
WP29M
SERIES HOOD
(Canopy with
blower controls
& lighting.
Required for all
installations.)
OPTIONAL
DECORATIVE FLUE
AEWP SERIES
OPTIONAL
FLAT TOP COVER
ADPWP SERIES
NON-DUCT KIT FLUE
ANKWP SERIES
NOTE: For a non-ducted installation, we
recommend the non-duct kit flue
ANKWP Series be installed with
Model P6 Blower/Rough-in kit for
effectiveness.
- WP29M SERIES RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Model 437
(High capacity roof cap)
Model 441
(10’ Round wall cap)
Model 634 or 644
(roof cap)
Model 647
(7” Round wall cap)
Model 407
(7” round duct—2 ft. sections)
Model 410
(10” round duct—2 ft. sections)
MODEL P6
BLOWER/ROUGH-IN KIT
(600 cfm interior blower &
rough-in plate)
MODEL P12
BLOWER/ROUGH-IN KIT
(1200 cfm interior blower
& rough-in plate)
Model 418
(10” round adjustable elbow)
- 4 -
HL0082
- WP29M SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
In-line and exterior blower rough-in kit
(included with EB6, EB9, EB12, EB15,
ILB3, ILB6, ILB9 and ILB11 blowers.)
Model 418
10” Round
adjustable elbow
(optional)
Model ILB3 (280 cfm)
in-line blower
(includes one 8” to 10”
round transition)
Model EB6 (600 cfm)
or EB9(900 cfm)
exterior blower
Model EB12 (1200 cfm)
or EB15 (1500 cfm)
exterior blower
Model 441
(10” Round
wall cap)
Model 437
(High capacity roof cap)
Model 441
(10” Round wall cap)
Model 421
(10” Round vert.
in-line damper)
Recommended
for use with
exterior blowers
Model 410
(10” Round duct
—2ft. sections)
Model ILB6 (600 cfm)
in-line blower
(includes two 4½” x 18½”
to 10’ round transitions)
Model ILB9 (800 cfm)
or ILB11 (1100 cfm)
in-line blower
(includes two 8” x 12” to
10’ round transitions)
WP29M
SERIES HOOD
(Canopy with
blower controls
& lighting.
required for all
installations.)
OPTIONAL
DECORATIVE FLUE
AEWP SERIES
OPTIONAL
FLAT TOP COVER
ADPWP SERIES
- 5 -
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.2 DUCTED INSTALLATION
For a ducted installation, either an interior or exterior blower or in-line blower may be used with this hood. The Best by Broan
WP29M Series must be installed with blower models P6, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only.
Other blowers cannot be substituted. (Blowers sold separately.)
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 8, 11, 12, 14
and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to
seal duct joints.
1.1 NON-DUCTED INSTALLATION
For a non-ducted installation, we recommend using interior blower Best by Broan model P6 for effectiveness. (Blower sold
separately.)
The non-duct kit ANKWP Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKWP Series.
7" (178 mm)
ROUND DUCT
ROOF CAP
7" (178 mm)
ROUND
ELBOW
24" TO 30" (609 mm to 762 mm)
ABOVE COOKING SURFACE
WALL CAP
HOOD
DECORATIVE
FLUE
or SOFFIT
6" or 12"
(152 mm
or 305 mm)
HH0068A
MODEL P6 SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
HOOD
DECORATIVE
FLUE or SOFFIT
6" or 12"
(152 mm
or 305 mm)
ROUND
TRANSITION
4½" x 18½" to 10"
(114 mm x 470 mm
to 254 mm)
(see page 3)
10" (254 mm)
ROUND DUCT
ROOF
CAP
HH0069A
24" to 30" (609 mm to 762 mm)
ABOVE COOKING SURFACE
WALL
CAP
MODEL P12 DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
EXTERIOR BLOWER
EXTERIOR
BLOWER
DECORATIVE FLUE
or SOFFIT
HH0070A
24" to 30" (609 mm to 762 mm)
ABOVE COOKING SURFACE
10" (254 mm)
ROUND DUCT
10" (254 mm)
ROUND ELBOW
HOOD
6" or 12"
(152 mm
or 305 mm)
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
In-line blower
10” round duct
HH0071A
24” to 30”
(609 to 762 mm)
above cooking
surface
Roof cap
Wall
cap
Hood
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER TYPICAL DUCTWORK
Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Wood strip (screwed on back of hood)
- Installation manual
- Accessories including:
• Evolutionary™ hybrid baffle filters (3 for hoods up to 54” width, 4 for 60” width)
• Shielded halogen lights (GU10 type base, 120 V, 50 W) (4 for hoods up to 42” width, 6 for hoods from 48” to 60” width)
• Bag of parts including:
(4) flat head screws #10-2’’, (8) screws #8 x 3/4’’, (4) nuts #10-32, (2) wall anchors, (2) washers 3/16’ ID x 3/4’ OD
Parts sold separately:
- Interior blower Model P6 (includes rough-in kit), for either ducted or non-ducted installation.
- Interior blower Model P12 (includes rough-in kit), for ducted installation only.
- In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include transition and rough-in plate), for ducted installation only.
- Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate), for ducted installation only.
- Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model
numbers.
- Non-duct kit ANKWPD Series, mandatory for non-ducted installation.
- Optional decorative flue AEWP Series, for ducted installation only.
- Optional flat top cover ADPWP Series, for ducting through back of hood, intalled on hood or installed on the optional decorative
flue AEWP Series. Can also be installed on the non-duct kit flue ANKWPD Series.
- 6 -
3. PREPARE THE INSTALLATION
2. MEASURE INSTALLATION
Dimensions for the most common installation are shown beside.
The minimum hood distance above cooktop must not be
less than 24’’. A maximum of 30” above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Ceiling
Cabinet, soffit,
decorative flue or
non-duct kit flue
Standard 36” (914 mm)
high cooktop
Top of wood
mounting strip
A + 0.25’ (6 mm)
Hood
A
HH0072A
Minimum distance between
the hood and cooktop:
24’ (610 mm)
Recommended maximum
distance between the hood
and cooktop: 30’ (762 mm)
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
CAUTION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and
gloves.
- 7 -
6. INSTALL WOOD MOUNTING STRIP
Measure and mark a level line on wall above cooktop location for the wood
mounting strip (see illustration beside and under step 2). Remove wood mounting
strip from back of hood.
Use #10 - 2’ flat head screws to secure the mounting strip to the drywall. Make
sure to hit the wall studs.
CAUTION
Due to the weight of this hood, ensure that the wood strip is
attached to all of the available studs (2 studs minimum for a 30’
width hood, more as hood width increases); not into the drywall
alone.
HD0174A
1. Drywall
2. Wood mounting strip
3. Flat head screw
4. Wall anchor location
5. Back of hood outline
6. Wall studs
4. REMOVE THE FILTERS AND THE GREASE DRIP RAIL(S)
A. Remove tape on filters.
Remove filters from hood and set aside.
NOTE: It is recommended to start with the
central one.
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set aside.
NOTE: The 60-inch width hood has 2 grease drip
rails.
HD0175
5. REMOVE THE PAN
Using a Phillips no. 2 or Robertson no. 2 screwdriver, remove the screws retaining
the pan (shaded part on illustration beside) to the hood. Remove the pan and set
aside.
HD0176
RETAINING SCREWS LOCATION
7. INSTALL THE FLUE AND/OR THE FLAT TOP COVER
7.1 DUCTED INSTALLATION:A) OPTIONAL DECORATIVE FLUE AEWP SERIES
For a ducted installation, refer to the instructions sheet included with the optional decorative flue.
B) OPTIONAL FLAT TOP COVER ADPWP SERIES
For ducting through back of hood only, install on hood or on the Optional Decorative Flue AEWP Series.
Refer to the instructions sheet included with the optional flat top cover.
7.2 NON-DUCTED INSTALLATION: NON-DUCT KIT FLUE ANKWP SERIES
Refer to the installation sheet included with the non-duct kit for details.
NOTE: The Optional Flat Top Cover ADPWP Series can be installed on the Non-Duct Kit Flue ANKWP Series. Refer to
the instructions included with the optional flat top cover.
1
- 8 -
11.INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL INSTALLATIONS)
11.1 ALL INSTALLATIONS:
Run power cable to installation location. Refer to the instructions included
with the selected blower/rough-in kit (sold separately) for details on
installing the rough-in plate. Install the rough-in plate so that the wiring
box is located on the right side as you are facing the hood.
11.2 DUCTED INSTALLATIONS ONLY:
For ducting through back of hood, remove existing plate from inside back
of hood and attach it to inside top of hood to cover hole. Secure to threaded
studs with same (4) nuts.
For ducting through top of hood, existing plate remains in place on inside
back of hood.
Connect ducting to transition or rough-in plate as you are installing the
rough-in plate. Use duct tape to make all joints secure and air-tight.
HD0179
Model 423, 424, 427 453, or 454
Attach transition (if required) to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
NOTE: Model P6 blower plate connects directly to 7’ round ductwork without
a transition.
9. SELECT BLOWER OPTION (EXTERIOR OR INTERIOR, DUCTED INSTALLATION)
INTERIOR BLOWER: Follow all subsequent steps of this manual.
EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 11 and up of the present manual.
HO0086
10.INSTALL TRANSITION TO ROUGH-IN PLATE (INTERIOR BLOWER, DUCTED INSTAL.)
8. INSTALL THE HOOD
Rest the top back cavity of the hood on the wood mounting strip.
Secure the hood to wood mounting strip with (4) screws #8 x 3/4” (for 30” and 36”
width hoods) or (6) screws (for 42” width and wider hoods) provided at locations
shown. Drill (2) 3/16’ size holes into the drywall for wall anchors through the existing
holes in the inside hood back in the locations shown. Then, install the two wall
anchors with the remaining #8 x 3/4” screws and the (2) washers provided.
For a non-ducted installation, go to step 11,
Install the Rough-in Plate.
CAUTION
Hold the hood until it is completely secured to the wood
mounting strip.
HD0178
WALL ANCHORS LOCATION
BACK OF HOOD (INSIDE VIEW)
T
OP OF HOOD (INSIDE VIEW)
R
OUGH-IN PLATE
ON TOP OF HOOD
PLATE ON BACK OF HOOD
LOCKNUTS
LOCKNUTS
MOUNTING SCREWS LOCATION
12.CONNECT THE WIRING (ALL INSTALLATIONS)
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.
WIRING COVER
- 9 -
13.INSTALL THE BLOWER (INTERIOR OR EXTERIOR BLOWER)
Refer to instructions included with blower.
Once the blower is installed, plug the blower cord (A) into the female receptacle
and the power supply cord (B) onto the male connector inside the hood.
HE0078
WARNING
Do not plug the two cords into each other.
!
AB
14.REINSTALL THE PAN
Using a Phillips no. 2 or Robertson no. 2 screwdriver and the retaining screws,
reinstall the pan (previously removed in step 6) inside the hood (shaded part on
illustration beside).
HD0176
RETAINING SCREWS LOCATION
Reinstall grease drip rail(s) (1). The illustration beside shows how to reinsert the
grease drip rail(s) into the range hood.
15.REINSTALL GREASE DRIP RAIL(S) AND BAFFLE FILTERS
HD0181
Before reinstalling Evolutionary™ hybrid baffle filters, slide out the secondary micromesh filters from their back and remove all
protective plastic film.
15.1 DUCTED INSTALLATION:
Slide in the secondary filters into each baffle filters before reinstalling them on the hood.
15.2 NON-DUCTED INSTALLATION:
Discard the secondary filters. Slide in the charcoal filters included in the non-duct kit. Reinstall the filters on the hood.
It is recommended to install side filters first and finish with
center one(s).
1. Insert one end of Evolutionary™ hybrid baffle filter into
the upper channel of the hood.
2. Raise the other end toward the inside of hood and insert
in the grease drip rail of the hood.
Replacement filters are available from your dealer. See label
inside hood for size and part number.
For charcoal filter replacement kit, see table on page 12.
1
HD0180
2
CAUTION
Remove protective plastic film covering Evolutionary™ hybrid baffle filters before installing them.
1
- 10 -
16.LIGHT BULBS REPLACEMENT
This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
WARNING
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed
fixtures.
WARNING
In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing
them.
1. To remove lamps, gently push upwards and turn counterclockwise
to disengage bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip
when removing the bulb.
2. Install the new lamps by placing the bulb leads into their
grooves in the socket.
3. Gently push upwards and turn clockwise until secure.
12 3
HO0089
17.USE AND CARE
Evolutionary™ Hybrid Baffle Filters
The Evolutionary™ hybrid baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your
cooking style generates greater grease—like frying foods or wok cooking.
Remove Evolutionary™ hybrid baffle filters by pushing them towards the back of hood and rotating filters downward. Slide out
the secondary micromesh filter from the back of each hybrid baffle filter before cleaning. Baffle filters are dishwasher safe. Clean
secondary filters with a warm detergent solution. Allow filters to dry completely before reinstalling them in the hood.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail
to dry completely before reinstalling it in the hood.
Blower Cleaning
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Refer to blower instruction
manual for more details.
Hood Cleaning
Stainless steel cleaning: How to maintain its “BRIGHT LOOK”
Do:
• Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel cleaner.
Don’t:
• Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
• Do not use any harsh or abrasive cleansers.
• Do not allow dirt to accumulate.
• Do not let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to
make sure no dust sticks to stainless steel surface.
Avoid: When choosing a detergent
Any cleaners that contain bleach will attack stainless steel.
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
CAUTION
Never attempt to wash the carbon filters in the non-duct kit. Those filters must be replaced by new ones.
Refer to the non-duct kit installation instructions for details.
- 11 -
18.OPERATION
Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
1. ON/OFF Blower switch 3. ON/OFF Halogen light switch
2. Blower speed control 4. Light intensity control
Blower
The blower is operated using two (2) controls.
Use the ON/OFF switch (item 1 on picture above) to start and stop the blower. When turned on, the blower will operate at the
previous setting of the speed control (item 2 on picture above).
Turn the speed control knob counterclockwise to increase blower speed—clockwise to decrease speed.
HEAT SENTRY
This hood is equipped with a HEAT SENTRY thermostat. This thermostat is a device that will speed up the blower if it senses
excessive heat above the cooking surface.
If blower is ON at a lower speed setting—it turns the blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
Cooktop Lighting (Halogen)
The halogen lighting is controlled by two switches; one ON/OFF switch (item 3 on picture above) and one light intensity control switch.
When turned on, the halogen bulbs will light cooktop at the previous setting of the light intensity control (item 4 on picture above).
Turn the light intensity control knob counterclockwise to increase lighting—clockwise to decrease lighting.
Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).
HC0030
1
2
3 4
WARRANTY
BROAN ONE-YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials
or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to
be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary
to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND
EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to
another. Any modification performed on this product without the authorization of Broan will void this warranty. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Best by Broan
®
, P.O. Box 140, Hartford, WI 53027 USA (1-800-637-1453)
Best by Broan
®
, 550 Lemire Blvd., Drummondville, QC J2C 7W9 CANADA (1-866-737-7770)
- 12 -
SERVICE PARTS
KEY PART QTY (HOOD WIDTH)
NO. NUMBER DESCRIPTION 30’ 36’ 42’ 48’ 54’ 60’
1 V16569 L
AMP SHELL, SOCKET AND TRIM ASSY 444666
2 V05921 H
ALOGEN BULBS (50 W, 120 V, PAR16, GU-10) 4 4 4 6 6 6
3 V07834 R
OTARY CONTROL 222222
4 V07689 T
OGGLE SWITCH 222222
5 V16966 P
LASTIC CONTROL FRAME AND KNOB ASSY 111111
6 V07688 K
NOB 222222
7 V13924 M
ALE CONNECTOR 111111
8 V13923 F
EMALE CONNECTOR 111111
V16793 G
REASE DRIP RAIL 30” 1 - - - - 2
9 V16794 G
REASE DRIP RAIL 36” - 1 1 - - -
V16796 G
REASE DRIP RAIL 48” - - - 1 1 -
10 V03435 T
HERMISTOR HEAT SENTRY 111111
V17115 I
NSIDE FRAME ASSY (30” X 24” X 18”) (INCLUDING ITEM 12) 1-----
V17116 I
NSIDE FRAME ASSY (36” X 24” X 18”) (INCLUDING ITEM 12) -1----
11
V17117 I
NSIDE FRAME ASSY (42” X 24” X 18”) (INCLUDING ITEM 12) --1---
V17118 I
NSIDE FRAME ASSY (48” X 24” X 18”) (INCLUDING ITEM 12) ---1--
V17119 I
NSIDE FRAME ASSY (54” X 24” X 18”) (INCLUDING ITEM 12) ----1-
V17120 I
NSIDE FRAME ASSY (60” X 24” X 18”) (INCLUDING ITEM 12) -----1
12 V05528 F
ILTER SPRING CLIP 333336
13
V07694 S
ECONDARY MICROMESH FILTER 8.84” X 8.50” 3 2 2 - - 6
V07695 S
ECONDARY MICROMESH FILTER 14.84” X 8.50” - 1 1 3 3 -
14
V16967 E
VOLUTIONARY™ HYBRID BAFFLE FILTER 8.95” X 8.61” X 1” (INCL. ITEM 13) 3 2 2 - - 6
V16968 E
VOLUTIONARY™ HYBRID BAFFLE FILTER 14.95” X 8.61” X 1” (INCL. ITEM 13) - 1 1 3 3 -
* V07693 I
NSTALLATION GUIDE 111111
P
ARTS BAG (FLAT HEAD SCREW #10 X 2’ (4),
* V12971 S
CREWS #8 X 3/4’ (8), NUTS #10-32 (4), 1 1 1 1 1 1
W
ALL ANCHORS (2), WASHERS 3/16’ ID X 3/4’ OD)
* V05869 B
EST BY BROAN LOGO 111111
* V16998 C
HARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)1---N/AN/A
* V16999 CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)-11-N/AN/A
* V17000 CHARCOAL FILTER KIT (INCLUDING 3 CHARCOAL FILTERS)---1N/AN/A
*NOT SHOWN.
KEY PART QTY (HOOD WIDTH)
NO. NUMBER DESCRIPTION 36’ 42’ 48’ 54’’ 60’
V17121 I
NSIDE FRAME ASSY (36” X 27” X 18”) (INCLUDING ITEM 12) 1 - - - -
V17122 I
NSIDE FRAME ASSY (42” X 27” X 18”) (INCLUDING ITEM 12) - 1 - - -
11 V17123 I
NSIDE FRAME ASSY (48” X 27” X 18”) (INCLUDING ITEM 12) - - 1 - -
V17124 I
NSIDE FRAME ASSY (54” X 27” X 18”) (INCLUDING ITEM 12) - - - 1 -
V17125 I
NSIDE FRAME ASSY (60” X 27” X 18”) (INCLUDING ITEM 12) - - - - 1
WP29XX4 MODEL
WP29XX7 MODEL
SAME PART NUMBERS, EXCEPT FOR ITEM 11 (SEE BELOW)
HL0083
1
2
9
7
8
4
11
6
5
3
10
13
14
12
CONÇUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE
INSTALLATEUR : LAISSER CE MANUEL AU PROPRIÉTAIRE.
PROPRIÉTAIRE : DIRECTIVES D’UTILISATION ET D’ENTRETIEN EN PAGES 22
ET 23.
GUIDE D’INSTALLATION
LIRE ET CONSERVER CES INSTRUCTIONS
!
!
SÉRIE WP29M
HB0058
V07693 rév. B
Aux États-Unis - BEST BY BROAN
®
P.O. Box 140, Hartford, WI 53027 USA
Au Canada - BEST BY BROAN
®
550 boul. Lemire, Drummondville, QC, J2C 7W9 CANADA
Pour obtenir plus d’information, consultez notre site www.bestbybroan.com
CONCEBIDO SÓLO PARA USO DOMÉSTICO
INSTALADOR: DEJAR ESTE MANUAL AL PROPRIETARIO.
PROPIETARIO: INSTRUCCIONES DE UTILIZACIÓN Y MANTENIMIENTO EN LAS
PÁGINAS 34 Y 35.
MANUAL DE INSTALACIÓN
LEER Y CONSERVAR ESTAS INSTRUCCIONES
!
!
SERIE WP29M
HB0058
V07693 rev. B
En Estados Unidos - BEST BY BROAN
®
P.O. Box 140, Hartford, WI 53027 USA
En Canadá - BEST BY BROAN
®
550 boul. Lemire, Drummondville, QC, J2C 7W9 CANADA
Para obtener más información, visitar nuestro sitio www.bestbybroan.com
- 29 -
1. SELECCIÓN DEL TIPO DE VENTILADOR E INSTALACIÓN
1.2 INSTALACIÓN CON TUBOS
Para una instalación con tubos, esta campana permite utilizar un ventilador interior, exterior o en línea. La serie WP29M
de Best by Broan sólo debe instalarse con los ventiladores P6, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 o EB15.
No utilice otros ventiladores. Los ventiladores se venden aparte.
Prevea el lugar y la forma en que instalará las tuberías.
Si instala un ventilador en línea, consulte las instrucciones que vienen con él y siga las etapas 1 a 8, 11, 12, 14 y
posteriores de este manual.
Instale tuberías, codos y capuchones para tejado o murales del tamaño adecuado para el tipo de ventilador que vaya a
poner. Utilice cinta para tubos metálicos para sellar las juntas de los tubos.
1.1 INSTALACIÓN SIN TUBOS
Para una instalación sin tubos, se recomendada de utilice el ventilador interior Best by Broan de modelo P6, a fin de mantener
la eficacia a su nivel óptimo. El ventilador se vende aparte.
Debe instalarse el juego para instalación sin tubos, serie ANKWP (se vende aparte). Este juego es apropiado a las campanas
de 30” a 48” de anchura.
TUBO REDONDO
DE 7" (178 mm)
CAPUCHÓN DE
TEJADO
CODO
REDONDO
DE
7" (178 mm)
DE 24" a 30" (609 a 762 mm)
POR ENCIMA DE LA SUPERFICIE
SOBRE LA QUE SE COCINA
CAPUCHÓN
MURAL
CAMPANA
CHIMENEA
DECORATIVA
6" o 12"
(152 mm
o 305 mm)
HH0068E
INSTALACIÓN HABITUAL CON
EL VENTILADOR SIMPLE P6
CAMPANA
CHIMENEA
DECORATIVA
6" o 12"
(152 mm
o 305 mm)
4 ½" x 18 ½" a 10"
(114 x 470 a 254 mm)
(véase la página 36)
TUBO
REDONDO
CAPUCHÓN
DE TEJADO
HH0069E
DE 24" a 30" (609 a 762 mm)
POR ENCIMA DE LA SUPERFICIE
SOBRE LA QUE SE COCINA
CAPUCHÓN
MURAL
CAMBIO
DE SECCIÓN
REDONDO DE
INSTALACIÓN HABITUAL CON
EL VENTILADOR DOBLE P12
VENTILADOR EXTERIOR
VENTILADOR
EXTERIOR
HH0070E
TUBO REDONDO
DE 10" (254 mm)
CODO REDONDO
DE 10" (254 mm)
CAMPANA
6" o 12"
(152 mm
o 305 mm)
CHIMENEA
DECORATIVA
DE 24" a 30" (609 a 762 mm)
POR ENCIMA DE LA SUPERFICIE
SOBRE LA QUE SE COCINA
INSTALACIÓN HABITUAL CON LOS
VENTILADORES EXTERIORES EB6, EB9,
EB12 O EB15
HH0071E
de 24” a 30’’(609 a 762 mm)
por encima de la superficie
sobre la que se cocina
Capuchón
del tejado
Campana
Ventilador
en línea
Tubo redondo
de 10”
Capuchón
mural
INSTALACIÓN HABITUAL CON LOS
VENTILADORES EN LÍNEA ILB3, ILB6,
ILB9 O ILB11
PIEZAS
N.
O
N.
O
CANTIDAD (ANCHURA DE LA CAMPANA)
REF. DE PIEZA DESCRIPCIÓN 30” 36” 42” 48” 54” 60”
1 V16569 C
ONJUNTO DE LA LAMPARA 4446 66
2 V05921 B
OMBILLAS HALÓGENAS (50 W, 120 V, PAR 16, GU-10) 4 4 4 6 6 6
3 V07834 C
ONTROL GIRATORIO 2222 22
4 V07689 I
NTERRUPTOR DE PALANCA 2222 22
5 V16966 E
STRUCTURA DE PLÁSTICO DE LOS CONTROLES Y CONJUNTO DE BOTONES 1111 11
6 V07688 B
OTÓN 2222 22
7 V13924 C
ONNECTADOR MACHO 1111 11
8 V13923 C
ONNECTADOR HEMBRA 1111 11
V16793 C
ANAL 30 PULG.1----2
9 V16794 C
ANAL 36 PULG.-11---
V16796 C
ANAL 48 PULG.---11-
10 V03435 T
ERMOSTATO HEAT SENTRY 1111 11
V17115 E
STRUCTURA INTERIOR (30” X 24” X 18”) (INCLUYE PIEZA 12) 1 - - - - -
V17116 E
STRUCTURA INTERIOR (36” X 24” X 18”) (INCLUYE PIEZA 12) - 1 - - - -
11
V17117 E
STRUCTURA INTERIOR (42” X 24” X 18”) (INCLUYE PIEZA 12) - - 1 - - -
V17118 E
STRUCTURA INTERIOR (48” X 24” X 18”) (INCLUYE PIEZA 12) - - - 1 - -
V17119 E
STRUCTURA INTERIOR (54” X 24” X 18”) (INCLUYE PIEZA 12) - - - - 1 -
V17120 E
STRUCTURA INTERIOR (60” X 24” X 18”) (INCLUYE PIEZA 12) - - - - - 1
12 V05528 C
LIP DEL FILTRO 3333 36
13
V07694 F
ILTRO DE MICROFILTRACIÓN SECUNDARIO 8,84” X 8,50” 3 2 2 - - 6
V07695 F
ILTRO DE MICROFILTRACIÓN SECUNDARIO 14,84” X 8,50” - 1 1 3 3 -
14
V16967 P
LACA DEL FILTRO HÍBRIDO EVOLUTIONARY™ 8,95” X 8,61” X 1” (INCL. PIEZA 13) 3 2 2 - - 6
V16968 P
LACA DEL FILTRO HÍBRIDO EVOLUTIONARY™ 14,95” X 8,61” X 1” (INCL. PIEZA 13) - 1 1 3 3 -
* V07693 M
ANUAL DE INSTALACIÓN 1111 11
B
OLSA CON PIEZAS PARA LA INSTALACIÓN (4 TORNILLOS N.
O
10 DE 2” DE
* V12971 CABEZA PLANA, 8 TORNILLOS N.
O
8 DE 3/4”, 4 TUERCAS N.
O
10-32, 1 1 1 1 1 1
2
DISPOSITIVOS DE SUJECIÓN MURAL, 2 ARANDELAS DE 3/16” DI X 3/4” DE)
* V05869 L
OGOTIPO BEST BY BROAN 111 1 11
* V16998 C
ONJUNTO DE FILTROS DE CARBÓN (INCLUIDO 3 FILTROS DE CARBÓN)1-----
* V16999 C
ONJUNTO DE FILTROS DE CARBÓN (INCLUIDO 3 FILTROS DE CARBÓN)-11---
* V17000 C
ONJUNTO DE FILTROS DE CARBÓN (INCLUIDO 3 FILTROS DE CARBÓN)---1--
*N
O SE MUESTRA.
N.
O
N.
O
CTD (ANCHURA DE LA CAMPANA)
REF. DE PIEZA DESCRIPCIÓN 36” 42” 48” 54” 60”
V17121 E
STRUCTURA INTERIOR (36” X 27” X 18”) (INCLUYE PIEZA 12) 1 - - - -
V17122 E
STRUCTURA INTERIOR (42” X 27” X 18”) (INCLUYE PIEZA 12) - 1 - - -
11 V17123 E
STRUCTURA INTERIOR (48” X 27” X 18”) (INCLUYE PIEZA 12) - - 1 - -
V17124 E
STRUCTURA INTERIOR (54” X 27” X 18”) (INCLUYE PIEZA 12) - - - 1 -
V17125 E
STRUCTURA INTERIOR (60” X 27” X 18”) (INCLUYE PIEZA 12) - - - - 1
MODELO WP29XX4
M
ODELO WP29XX7
LOS NÚMEROS DE LAS PIEZAS SON LOS MISMOS EXCEPTUANDO LA PIEZA 11 (VÉASE ABAJO).
HL0083
1
2
9
7
8
4
11
6
5
3
10
13
14
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Best WP29M User manual

Category
Cooker hoods
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages