Theory of Operation
Operation of the 7300L centers around three
primary components: the Model 7000 pump, the
Model VM-1100 Verometer and the Model N-300
controller.
During normal operation, the Model 7000 pump injects
an exact quantity of odorant at a rate determined by
the N-300 controller. The quantity of odorant
injected per stroke is set using a spacer in the pump
actuation assembly. The rate at which the pump is
actuated is determined by the N-300 controller.
The VM-1100 Verometer serves as a temperature
compensated meter which verifies the amount of odorant
injected by the Model 7000 pump. The N-300 control-
ler uses an input signal from the Verometer to deter-
mine the amount of odorant that has been injected, as
well as the odorant level within the Verometer. Once
the odorant level falls to a predetermined low level
point, the N-300 controller actuates a solenoid valve
which opens the fill valve, allowing the Verometer to be
refilled. Once the Verometer is filled, the N-300 control-
ler closes the fill valve.
The N-300 controller allows the 7300L system to
operate in either a time-based mode or a proportional-
to-flow mode. In the time-based mode of operation,
the N-300 controller actuates the Model 7000 pump
at a regular time interval preset by the operator.
In the proportional-to-flow mode of operation, the
N-300 controller uses a customer provided gas flow
rate input signal and several operator input values to
calculate the time between strokes of the pump. These
operator input values include the odorant injection rate
(lbs/10K gallons or mg/liter), pump displacement
(cc/stroke), and the odorant density (lbs/gal or g/cc).
The flow input signal is customer provided by either
a flow computer or other flow monitoring devices. In
this mode, the controller has the capability to distin-
guish between a low flow situation and a loss of flow
input signal. For systems with analog inputs, if a
loss of flow signal occurs, the controller automati-
cally defaults back to a pre-selected percentage of
the flow input.
The flow input signal is read by the N-300 controller
eight times per pump stroke. These readings are
averaged and the time duration until the next stroke
is then calculated by the controller. The maximum
time between strokes is 99.99 minutes (when gas is
flowing), regardless of the time calculated by the
controller.
Odorant usage by load information is available by
utilizing the Sentry4 Software to access data from
the N-300 controller. The per Load Odorant Usage
data is documentated from the odorizer perfor-
mance data in conjunction with a customer provided
loading cycle relay status, refer to the Wiring
Control Document on page 116 in Appendix D.
Caution:
Excessive tubing lengths should be avoided.
Installation of the NJEX Odorization system should
be as close to the point of injection and Odorant
Storage Tank as possible. Maximum tubing length
should not exceed 15' (4.5 meters) with the tubing
size maintained as indicated in this manual. If longer
tubing lengths are required consult YZ Systems
Technical Services at; 800.653.9435 or
1.936.788.5593.
System Accessories
• Odorant Injection Probe, includes a 316
stainless steel probe, and isolation valve for location
atthe pipeline. When ordering, please specify pipeline
connection required, 1/2" or 3/4".
• 1/4" stainless steel discharge tubing In-line Check Valve. For
placement in the odorant discharged tubing line immedi-
ately preceding the probe assembly, (P/N A3-0024).
• 1/4" stainless steel tubing Dielectric Isolator Union.
These should be installed in every tubing line that
attaches the odorizer to the pipeline in any manner.
For example the supply gas, odorant discharge, and
differential pressure switch connections, (P/N A1-0182).
A complete line of odorization accessories ranging
from pre-odorized gas scrubbers to injection
probes is available through YZ. Please contact
your local representative or YZ toll free at
800.344.5399. For technical support call
800.653.9435.