SETTING THE OPERATING SCHEDULES SETTING THE OPERATING SCHEDULES
Press the time for (Program 1) will flash.
to press the time for (Program 1) will flash.
Use to adjust the time for Program 1.
Use to adjust the time for
Program 1
.
Use to adjust the setpoint for
Program 1.
5°C~35°C
Default Settings
MONDAY - FRIDAY SATURDAY - SUNDAY
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
PROGRAM
0700 0700
0930 0930
1630 1630
2230
22 C
C
C
C
O
16O
22O
16O
22 C
C
C
C
O
16O
22O
16O
2230 C
C
C
C
22O
16O
22O
16O C
C
C
C
22O
16O
22O
16O
For 5+2 day programmable modedefault)
Changing programs for Monday- Friday
When Monday-Friday programs have been set, continue
Changing programs for Saturday- Sunday
Press the setpoint for
Program 1
will flash.
Press the time for (Program 2) will flash.
Use to adjust the time for
Program 2.
Use to adjust the setpoint for
Program 2.
Repeat above steps for
Program 3
and
Program 4
.
Press the setpoint for
Program 2
will flash.
Press , the setpoint for
Program 1
will flash.
period of Program 2 and Program 3, Press
Press again to cancel.during programing.
Note:
For Saturday-Sunday, if you want to clear the time
Press and hold for about 5 seconds to
and hold for about 5 seconds again
Default Settings
For 7 day programmable mode
Press the day display will start flashing.
INSTALLATION
Carefully separate the front half of the thermostat from
the back plate by placing a small flat head terminal driver
into the slots on the bottom face of the thermostat.
Carefully unplug the cable connector which is plugged
into the front half of the thermostat.
Place the thermostat front half somewhere safe.
Follow the Wiring Diagram to connect the floor heating
cold leads, floor temperature sensor and electrical
supply to the appropriate terminals.
Screw the thermostat back plate onto the flush box.
Re-connect the thermostat cable and clip the two halves
back together.
select all 7 days of the week, and to cancel press and
TECHNICAL INFORMATION
LCD SYMBOLS
SUPPLY VOLTAGE
SPECIFICATIONS
SWITCHING CAPABILITY
TEMP RANGE(A)
FLOOR SENSOR
resistance default to 25°C
IP RATING
ORIENTATION
230-240 VAC
8A max for each zone
10 Kohm.
30
VERTICAL
key lock symbol
the heating is turned on
the program numbers
set temperature
sensor not installed or error
manual mode
temporary override
auto mode
decrease
increase
confirm the settings
program button
mode button / menu button
power on / off
SETPOINT
TIME TIME
ZONE 1 ZONE 2
SETPOINT
ZONE 1 ZONE 2
MONDAY - SUNDAY
PROGRAM
0700
0930
1630
2230
22 C
C
C
C
O
16O
22O
16O
22 C
C
C
C
O
16O
22O
16O
SETPOINT
TIME
ZONE 1 ZONE 2
flashing
period of Program 2 and Program 3, press
Press again to cancel.during programing.
Note:
For Saturday-Sunday, if you want to clear the time
Press , the time for (Program 2) will flash.
Use to adjust the setpoint for
Program 1.
Use to select the day.
Use to adjust the time for
Program 2.
Use to adjust the setpoint for
Program 2.
Repeat above steps for
Program 3
and
Program 4
.
Press , the setpoint for
Program 2
will flash.
Press the time for (Program 1) will flash.
Use to adjust the time for Program 1.
Use to adjust the setpoint for
Program 1.
Press the setpoint for
Program 1
will flash.
Press the time for (Program 2) will flash.
Use to adjust the time for
Program 2.
Use to adjust the setpoint for
Program 2.
Repeat above steps for
program 3
and
Program 4
.
Press , the setpoint for
Program 2
will flash.
DIMENSIONS
WIRING DIAGRAM
Heater 1 refers to heating element in zone 1
Sensor 1 refers to sensor installed for zone 1
Sensor 2 refers to sensor installed for zone 2
Heater 2 refers to heating element in zone 2
62mm
60mm
45mm
87 mm
80mm
121 mm
67 5 4 3
8A
8A
N L
AC 230V
Heater 1
Heater 2
2 1
Sensor 1
Sensor 2
Note: