Kistler 2516B12, 2516B1 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Kistler 2516B12 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Instruction
Manual
Software for Engine
Peak Meter
Type 2516B…
Version 1.07
2516B
_
002-591e-07.11
Instruction
Manual
Software for Engine
Peak Meter
Type 2516B…
Version 1.07
2516B_002-591e-07.11
Foreword
2516B_002-591e-07.11 Page 1
Foreword
Thank you for choosing a Kistler quality product
characterized by technical innovation, precision and long
life.
Information in this document is subject to change without
notice. Kistler reserves the right to change or improve its
products and make changes in the content without
obligation to notify any person or organization of such
changes or improvements.
©2011 Kistler Group. All rights reserved. Except as
expressly provided herein, no part of this manual may be
reproduced for any purpose without the express prior
written consent of Kistler Group.
Kistler Group
Eulachstrasse 22
8408 Winterthur
Switzerland
Tel. +41 52 224 11 11
Fax +41 52 224 14 14
www.kistler.com
Software for Engine Peak Meter, Type 2516B…
Page 2 2516B_002-591e-07.11
Contents
1. Introduction ................................................................................................................................... 3
1.1 Disposal Instructions for Electrical and Electronic Equipment ................................................ 3
2. Product........................................................................................................................................... 4
2.1 Description........................................................................................................................... 4
2.2 Requirements ....................................................................................................................... 5
2.2.1 Hardware ................................................................................................................ 5
2.2.2 Software.................................................................................................................. 5
2.2.3 Included Accessories................................................................................................ 5
3. Installing and Removal .................................................................................................................. 6
3.1 Installing............................................................................................................................... 6
3.2 Removal ............................................................................................................................... 6
4. Program ......................................................................................................................................... 7
4.1 Main Window ...................................................................................................................... 7
4.2 Menu Functions ................................................................................................................... 7
4.3 Function Buttons .................................................................................................................. 8
5. Data Transfer ................................................................................................................................. 9
5.1 TDC Shift and Saving Data................................................................................................. 11
6. Measurement Presentation .......................................................................................................... 14
6.1 Choosing Displayed Cylinders ............................................................................................ 14
6.1.1 Comparing Cylinder Pressure Curves from Measurements over Different Time
Periods .................................................................................................................. 14
6.1.2 Zooming Curves .................................................................................................... 14
6.1.3 Cursor Function..................................................................................................... 15
6.2 Data Table.......................................................................................................................... 15
6.3 Cylinder Balancing..............................................................................................................16
6.4 Bar Charts .......................................................................................................................... 16
Total pages: 16
Introduction
2516B_002-591e-07.11 Page 3
1. Introduction
Please take the time to thoroughly read this instruction
manual. It will help you with the installation, maintenance,
and use of this product.
To the extent permitted by law Kistler does not accept any
liability if this instruction manual is not followed or
products other than those listed under Accessories are
used.
Kistler offers a wide range of products for use in measuring
technology:
Piezoelectric sensors for measuring force, torque, strain,
pressure, acceleration, shock, vibration and acoustic-
emission
Strain gage sensor systems for measuring force and
torque
Piezoresistive pressure sensors and transmitters
Signal conditioners, indicators and calibrators
Electronic control and monitoring systems as well as
software for specific measurement applications
Data transmission modules (telemetry)
Kistler also develops and produces measuring solutions for
the application fields engines, vehicles, manufacturing,
plastics and biomechanics sectors.
Our product and application brochures will provide you
with an overview of our product range. Detailed data
sheets are available for almost all products.
If you need additional help beyond what can be found
either on-line or in this manual, please contact Kistler's
extensive support organization.
1.1 Disposal Instructions for Electrical and Electronic Equipment
Do not discard old electronic instruments in municipal
trash. For disposal at end of life, please return this
product to an authorized local electronic waste disposal
service or contact the nearest Kistler Instrument sales
office for return instructions.
Software for Engine Peak Meter, Type 2516B…
Page 4 2516B_002-591e-07.11
2. Product
2.1 Description
This software is used to display the numerical measurement
data and visualize the pressure curve. The curve shows
the variation in cylinder pressure with time. For clarity
this function is represented in degrees of crank angle,
720 scale graduations corresponding to 360 °. Rotational
irregularities are not taken into account and the curve is
not adjusted for TDC. The software also calculates and
shows on the diagram the mean value of the saved
measurements pmax, pav and pmin.
Fig. 1: Main window of PC software
Product
2516B_002-591e-07.11 Page 5
2.2 Requirements
2.2.1 Hardware
Computer with 80386 or better Intel or compatible
processor
10 MB of free hard drive space
Serial interface or USB (only with USB to RS-232C
converter)
2.2.2 Software
Operating system: MS Windowsâ 98, NT 4.0, 2000, XP
or Windowsâ 7
2.2.3 Included Accessories
An English language version of the software for the above-
mentioned operating systems is supplied on a CD.
Software for Engine Peak Meter, Type 2516B…
Page 6 2516B_002-591e-07.11
3. Installing and Removal
3.1 Installing
1. Insert the installation CD into your computer's CD
drive
2. Choose "Install PC Program" from the menu and
follow the instructions
3.2 Removal
Choose the "Settings/Control Panel/Software" command
from the "Start" menu. Choose "Engine Peak Meter" and
then "Add/Remove".
The removal routine deletes all program files, but not the
measurement files that have been created.
Program
2516B_002-591e-07.11 Page 7
4. Program
4.1 Main Window
The main window consists of a menu bar, a tab for
choosing how the measurements are to be displayed and
the display field. In the top left corner there is a bar for
choosing the measurement data (see chapter 2.1, Fig. 1.)
Fig. 2: Top of main window with menu bar, function buttons and table for displaying the measurement
data (see chapter 6.1)
4.2 Menu Functions
The following functions can be accessed via menu and
function buttons:
"File" Menu
Open a saved data file. Open a second data file
(Reference) for comparison purposes. Add comments to
the data file.
"Data" Menu
Transfer data from the EPM. Shift the pressure curve on
the x-axis for improved display
Set the transfer parameters and edit the display.
"About" Menu
Shows version number.
Only firmware version 1.04 and newer.
Software for Engine Peak Meter, Type 2516B…
Page 8 2516B_002-591e-07.11
4.3 Function Buttons
Open – open a saved data file
Reference – open a second data file for comparison
purposes
Save – save a data file
Measurement properties – enter a comment that
can be saved together with the data file (such as
engine number, engine load case, etc.)
Print preview - preview before printing
Print – print a hardcopy
Transfer – start the data transfer from the EPM
TDC Shift – shift the pressure curve on the x-axis
Setup - change the labeling and colors of the
pressure curve, choose the COM interface,
activate/deactivate the limit display function
Fig. 3: Function buttons with description
Data Transfer
2516B_002-591e-07.11 Page 9
5. Data Transfer
1. Connect EPM to the PC with the included PC link
cable
2. Start program and display Setup Menu
Fig. 4: "Setup" window for the COM interface, with the
option of changing the pressure unit and curve
colors
Software for Engine Peak Meter, Type 2516B…
Page 10 2516B_002-591e-07.11
3. Choose COM interface; the name of the vessel or
system can be entered
4. Display Transfer Menu and follow the instructions in
the Data Transfer box. The progress of the data
transfer will be displayed.
Fig. 5: "Data Transfer" window with related instructions.
On the Type 2516B... the transfer has to be started
manually
Fig. 6: The progress of the data transfer is displayed
The measurement data (memory block and cylinder
number) are chosen and the data transfer carried out on
the engine peak meter.
Data Transfer
2516B_002-591e-07.11 Page 11
5. After the data transfer additional comments can be
entered using the "Measurement Properties" menu.
Fig. 7: "Measurement Properties" menu allowing entry of
additional comments on the measurement
If the data transfer fails, please check whether the
correct COM interface has been set and the cable is
properly connected. Take note that only the included
connection (null modem) cable may be used for the data
transfer. Only new firmware supported.
5.1 TDC Shift and Saving Data
After the data transfer, system factors may cause the
pressure curve to be displayed significantly offset on the
x-axis. The curve can be shifted on this axis with the aid of
the "TDC Shift" function.
Fig. 8: Curve significantly offset on x-axis
Software for Engine Peak Meter, Type 2516B…
Page 12 2516B_002-591e-07.11
Fig. 9: Curve corrected with the TDC Shift function
Data Transfer
2516B_002-591e-07.11 Page 13
The data is then saved with the "Save" menu.
Fig. 10: "Save As" menu
Software for Engine Peak Meter, Type 2516B…
Page 14 2516B_002-591e-07.11
6. Measurement Presentation
6.1 Choosing Displayed Cylinders
This choice is also made in the main window, by checking
or unchecking the individual cylinders on the selection bar.
Fig. 11: Twelve measurements chosen from memory block
one
6.1.1 Comparing Cylinder Pressure Curves from Measurements over Different Time
Periods
The "Reference" function allows viewing the change in the
cylinder pressure curve over a long period of time. For this
purpose the pressure curves from two measurements can
be compared with one another.
Procedure:
Choose display so that only one pressure curve is shown.
Pressing the "Reference" function button opens a dialog
box for choosing the data files. When the file is opened,
the cylinder pressure curve with the same cylinder number
is shown automatically.
6.1.2 Zooming Curves
To zoom in on the curve, the left mouse button is pressed
and the mouse dragged over the relevant part of the curve.
Double-clicking with the left button cancels the zoom
function.
Measurement Presentation
2516B_002-591e-07.11 Page 15
Fig. 12: Detail marked for zooming
6.1.3 Cursor Function
Right-clicking activates the cursor function.
Fig. 13: View of data table
6.2 Data Table
Clicking the "Data Table" displays all of the numerical
values.
Software for Engine Peak Meter, Type 2516B…
Page 16 2516B_002-591e-07.11
6.3 Cylinder Balancing
This function compares the measurements of each
individual cylinder with the calculated mean saved in the
same memory block. The calculated mean is shown on the
right on the y-axis. A percentage limit for this deviation can
be entered on the Setup Menu.
Fig. 14: "Cylinder Balancing" view
6.4 Bar Charts
The measurements are displayed in the form of bar charts.
If the measured value pav is displayed, the standard
deviation will also be shown on the diagram.
Fig. 15: View of bar chart
/