1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional
information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
Content
1 About this document
1.1 Function ..............................................1
1.2 Target group: authorised qualied personnel..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................2
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Comprehensive quality insurance to 2006/42/EC ..............2
2.4 Purpose ..............................................2
2.5 Technical data .........................................2
2.6 Safety classication .....................................3
3 Mounting
3.1 General mounting instructions .............................3
3.2 Dimensions ...........................................4
3.3 Actuating positions of the safety sensor with regard to the actuator 4
3.4 Switch distance ........................................4
3.5 Adjustment............................................5
4 Electrical connection
4.1 General information for electrical connection..................5
4.2 Series-wiring ..........................................5
5 Diagnostic functions
5.1 Operating principle of the diagnostic LEDs ...................6
5.2 Operating principle of the electronic diagnostic output ..........6
5.3 Safety-sensors with serial diagnostic function .................7
6 Set-up and maintenance
6.1 Functional testing.......................................8
6.2 Maintenance ..........................................8
7 Disassembly and disposal
7.1 Disassembly...........................................8
7.2 Disposal ..............................................8
8 Appendix
8.1 Wiring examples .......................................8
8.2 Wiring conguration and connector accessories ...............9
9 EU Declaration of conformity
x.000 / 01.2020 / v.A. - 101185245-EN / I / 2020-01-10 / AE-Nr. 11847
EN
Operating instructions. . . . . . . . . . . .pages 1 to 10
Original
2
Operating instructions
Safety sensor
CSS 34
EN
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety
switchgear, personal hazards or damages to machinery
or plant components cannot be excluded. The relevant
requirements of the standard ISO 14119 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages
resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary
repairs, conversions and modifications to the device are strictly
forbidden; the manufacturer shall accept no liability for damages
resulting from such invasive work, arbitrary repairs, conversions and/or
modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
CSS-
-34
-
-M-
No. Option Description
12
14
Switching distance S
n
(mm)
Actuation from top
Actuation from side
S lateral active surface
V frontal active surface
D With diagnostic output
SD With serial diagnostic function
L with connecting cable
ST with integrated connector
Only if the information described in this operating instructions
manual are realised correctly, the safety function and
therefore the compliance with the Machinery Directive is
maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery
Directive. As a result, Schmersal is entitled to autonomously conduct
the conformity assessment procedure for the products listed in
Appendix IV of the MD without involving a notified body. The prototype
test certificates are available upon request or can be downloaded from
the Internet at www.schmersal.com.
2.4 Purpose
This non-contact, electronic safety sensor is designed for application in
safety circuits and is used for monitoring the position of movable safety
guards. In this application, the safety sensor monitors the position of
hinged, sliding or removable safety guards by means of the coded
electronic CST 34 or CST 180 actuators (refer to table "Actuators and
switching distances").
The safety function consists of safely switching off the safety outputs
when the safety guard is opened and maintaining the safe switched off
condition of the safety outputs for as long as the safety guard is open.
The safety switchgears are classified according to
ISO 14119 as type 4 switching devices.
The diagnostic output of the CSS 34 safety sensor alternatively can be
used as conventional output or as “serial output“ with input and output
channel.
Series-wiring
Series-wiring can be set up. Response and risk times remain
unchanged by series-wiring. The number of components is only limited
by the external cable protection according to the technical data and
the line loss. Series-wiring of up to 31 CSS 34 … SD components with
serial diagnostics is possible.In devices with the serial diagnostics
function (ordering suffix -SD), the serial diagnostics connections
are wired in series and connected to a SD Gateway for evaluation
purposes.
Wiring examples for series-wiring, refer to appendix.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
If multiple safety sensors are involved in the same safety
function, the PFH values of the individual components must
be added.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.5 Technical data
Standards: IEC 60947-5-3, ISO 13849-1,
IEC 61508, IEC 62061
Enclosure: glass-fibre reinforced thermoplastic
Operating principle: inductive
Coding level according to ISO 14119: low
Actuator and switch distances
(according to IEC 60947-5-3): see table "Actuator / Switch distances“
Hysteresis: max: 1.5 mm
Repeat accuracy R: < 0.5 mm
Maximum switching frequency: 3 Hz
Series-wiring: Unlimited number of components,
please observe external cable protection,
max. 31 components in case of serial diagnostics
Cable length: max. 200 m (cable length and cable section alter the
voltage drop depending on the output current)
Connector: M12, 8-pin in casing
Pre-wired cable: Y-UL 2517 / 8 × AWG 22 / 8 × 0.35 mm², 2 m
Temperature resistance of the cable:
- at rest: −30 °C … +105 °C
- in motion: −10 °C … +105 °C
Ambient conditions:
Ambient temperature T
u
: –25 °C to +70 °C
with output current ≤ 0.1 A / Output
–25 °to +65 °C
with output current ≤ 0.25 A / Output
Storage and transport temperature: –25 °C … +85 ºC
Resistance to vibration: 10 … 55 Hz, amplitude 1 mm
Resistance to shock: 30 g / 11 ms
Protection class: IP65, IP67 to IEC 60529
3
CSS 34
Operating instructions
Safety sensor
EN
Electrical data:
Rated operating voltage U
e
: 24 VDC −15% / +10%
(stabilised PELV to IEC 60204-1)
Rated operating current I
e
: 0.6 A
Required rated short-circuit current: 100 A
Fuse (line protection): note the wire
diameter of continuing wire:
- for wire variants: up to 45 °C ambient temperature: 4.0 A
up to 60 °C ambient temperature: 3,15 A
up to 65 °C ambient temperature: 2,5 A
up to 70 °C ambient temperature: 2,0 A
- for plug version: 2.0 A
Rated insulation voltage U
i
: 32 VDC
Rated impulse withstand voltage U
imp
: 800 V
No-load current I
o
: 0.1 A
Response time: < 30 ms
Duration of risk: < 60 ms
Protection class: II
Overvoltage category: III
Degree of pollution: 3
EMC rating: according to IEC 60947-5-3
Electromagnetic interference: according to IEC 60947-5-3
Safety inputs X1/X2:
Accepted test pulse duration on input signal: ≤ 1.0 ms
- With test pulse interval of: ≥ 100 ms
Classification: ZVEI CB24I
Sink: C1 Source: C1 C2 C3
Safety outputs Y1/Y2: normally open function, 2 channel,
p-type, short-circuit proof
Rated operating voltage U
e
1: max. 1 V under U
e
Leakage current I
r
: < 0.5 mA
Rated operating current I
e1
: max. 0.25 A, dependent
on ambient temperature
Utilisation category: DC-12, DC-13
Rated operating voltage/current U
e1
/I
e1
: 24 VDC / 0.25 A
Test pulse duration: ≤ 1.0 ms
Test pulse interval: 1,000 ms
Classification: ZVEI CB24I
Source: C1 Sink: C1
Diagnostic output: short-circuit proof, p-type
Voltage drop: < 5 V
Rated operating voltage U
e2
: min. (U
e
– 5 V)
Operating current I
e2
: max. 0,05 A
Utilisation category: DC-12, DC-13
Rated operating voltage/current U
e2
/I
e2
: 24 VDC / 0.05 A
Wiring capacitance for serial diagnostics: max. 50 nF
2.6 Safety classification
Standards: ISO 13849-1, IEC 61508, IEC 62061
PL: e
Control Category: 4
PFH value: 3.6 x 10
-9
/ h
SIL: suitable for SIL 3 applications
Mission time: 20 years
3. Mounting
3.1 General mounting instructions
Please observe the relevant requirements of the standards
ISO 12100, ISO 14119 and ISO 14120.
The component can be mounted in any position. The active surface
of the safety sensor and the actuator has to be opposite. The sensor
enclosure must not be used as an end stop. The active surface of the
safety sensor is either the lateral surface marked with the type plate or
the front, rounded surface. The safety sensor must only be used within
the assured switching distances ≤ s
ao
and ≥ s
ar
.
The safety sensor and the CST 34-.-1 or CST 34-S-2 actuators are
supplied with integrated mounting plate. With the slotted holes of the
mounting plates, possible tolerances can be horizontally and vertically
compensated. The components are fitted with M4 screws.
The safety sensors and the actuators can be clipped onto the mounting
plate with different actuating directions. Both components are fixed by
means of a locking cap.
The actuator must be permanently fitted to the safety guards
and protected against displacement by suitable measures
(tamperproof screws, gluing, drilling of the screw heads).
The mounting plates must be pinned after their fixation.
The mounting brackets also must be secured by means of
the supplied locking pin to protect them against tampering.
The CST-S-3 and CST 180 actuators must be protected by
tamper-proof screws or a tamper-proof fitting.
At an ambient temperature of over 55°C, the safety sensor
must be fitted so that it is protected against unintentional
contact with persons.
To avoid any interference inherent to this kind of system and any
reduction of the switching distances, please observe the following
guidelines:
Minimum distance between two sensors: 100 mm
4
Operating instructions
Safety sensor
CSS 34
EN
3.2 Dimensions
All measurements in mm.
Safety sensor size
27
97,2
35
108,2
M12x1
Dimensions Actuator
2735
97,2
101,7
Alternative suitable actuators with different design: refer
to www.schmersal.net.
Integrated mounting plate
35
8
27
101,7
42,5
4,5
50
R4,6
R2,1
¤5
Holes to be pinned Hole for the pin
3.3 Actuating positions of the safety sensor with regard to the
actuator
Lateral actuation Actuation from front
CST 34-S-1
CSS ..-34-S
CST 34-V-1
CSS ..-34-V
CST 34-S-3
CSS ..-34-S
CSS ..-34-V
CST 34-S-3
CST 34-S-2
CSS ..-34-S
CSS ..-34-V
CST 34-S-2
CST 180-1/-2
CSS ..-34-S
CSS ..-34-V CST 180-1/-2
3.4 Switch distance
Actuators and switching distances (to EN 60947-5-3)
Actuator Sensor CSS ..-34-S
(Actuation from side)
CSS ..-34-V
(Actuation from front)
CST 34-V-1 s
n
s
ao
s
ar
10 mm
8 mm
13 mm
12 mm
10 mm
15 mm
CST 34-S-1
CST 34-S-3
s
n
s
ao
s
ar
14 mm
12 mm
17 mm
15 mm
13 mm
18 mm
CST 34-S-2
(increased
misalignment)
s
n
s
ao
s
ar
14 mm
12 mm
17 mm
10 mm
8 mm
16 mm
CST 180-1
CST 180-2
s
n
s
ao
s
ar
10 mm
8 mm
13 mm
12 mm
10 mm
16 mm
Key
S
n
Rated operating distance
S
ao
Assured switching distance
S
ar
Assured switch-off distance
Maximum misalignment from side
Y
X
5
CSS 34
Operating instructions
Safety sensor
EN
Actuation from side
The side allows for a maximum height misalignment (X) of sensor
and actuator of 36 mm (e.g. mounting tolerance or due to guard door
sagging). Increased misalignment, max. 53 mm, possible when the
CST 34-S-2 actuator is used. The axial misalignment (Y) is max. ± 10
mm.
Maximum misalignment from front
Z
Actuation from front
The front face allows for an axial misalignment
(Z) of max. ± 8 mm.
3.5 Adjustment
The distance between the sensor and the actuator must be set to < S
ao
.
If variations in the clearance between the sensor and the actuator is
detected (e.g. sagging of a safety guard), this distance must be reduced
by 4 mm. The yellow LEDs and the diagnostic output indicate the
different ranges.
Recommended Adjustment
Align the safety sensor and actuator at a distance of 0.5 x s
ao
.
The correct functionality of both safety channels must be checked by
means of the connected safety-monitoring module.
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
The power supply for the safety sensors must provide protection
against permanent over-voltage. Under fault conditions, the voltage
must not exceed 60 V. supply units according to IEC 60204-1 is
recommended.
The safety outputs can be integrated into the safety circuit of the control
system. For applications of PL e / control category 4 to ISO 13849-1,
the safety outputs of the safety sensor or sensor of the chain must be
wired to a safety monitoring module of the same control category .
Requirements for the connected safety-monitoring module
Dual-channel safety input, suitable for p-type safety sensors with NO
function.
Digital inputs to EN 61131-2, Table "Standard operating ranges for
digital inputs (current sinking)"
The safety sensors cyclically switch off the output to test them. The
switch-off times of max. 500 μs must be tolerated by the evaluating
device. Short-circuit recognition by the evaluation is not necessary.
Note on the total length of a safety sensor chain, refer to paragraph
"Series-wiring". The maximum load current of 250 mA per safety
channel must be observed. Contactors with higher load currents must
be controlled by intermediate control relays.
Information for the selection of suitable safety-monitoring
modules can be found in the Schmersal catalogues or in the
online catalogue on the Internet: www.schmersal.net.
The self-monitoring safety sensors of the CSS 34F0 or CSS 34F1
series can replace the safety-monitoring module. Therefore, they can
only be used as the first sensor of a series-wired sensor chain. (refer to
operating instructions CSS 34F0 / CSS 34F1).
If the safety sensor is connected to electronic safety-
monitoring modules, we recommend that you set a
discrepancy time of 100 ms. The safety inputs of the safety-
monitoring module must be able blanking a test impulse of
approx. 1 ms. The safety-monitoring module does not need to
have a cross-wire short monitoring function, if necessary, the
cross-wire short monitoring function must be disabled.
4.2 Series-wiring
Series-wiring can be set up. The number of devices is limited for safety
reasons. Series-wiring of CSS 34-…-SD with serial diagnostics is
possible for up to 31 devices. A 200 m long sensor chain can be set up.
Please note that voltage losses could occur (due to cable length, cable
section, voltage drop/sensor)! For longer cable lengths, the section of
the connecting cables must be taken as large as possible.
Wiring examples for series-wiring, refer to appendix.
Protection is not required when pilot wires are laid. The cables however
must be separated from the supply and energy cables. The max. fuse
rate for a sensor chain depends on the section of the connecting cable
of the sensor.
Cable design in case of serial diagnostics
The wiring capacitance of the connecting cable of the safety sensor
must not exceed 50 nF.
Depending on the strand structure, normal unshielded 30 m long control
cables LIYY 0.25 mm
2
to 1.5 mm
2
have a wiring capacitance of approx.
3 … 7 nF.
When wiring SD devices, please observe the voltage drop
on the cables and the current carrying capacity of the
individual components.
Accessories for the series-wiring
For convenient wiring and series-wiring of SD components,
the SD junction boxes PFB-SD-4M12-SD (variant for the
field) and PDM-SD-4CC-SD (variant for control cabinet on
carrier rail) are available along with additional comprehensive
accessories. Detailed information is available on the Internet,
www.schmersal.net.
6
Operating instructions
Safety sensor
CSS 34
EN
5. Diagnostic functions
5.1 Operating principle of the diagnostic LEDs
The safety sensor indicates the operating condition and faults by means
of three-colour LEDs located in the lateral surfaces of the sensor.
The following LED indicators are the same for safety sensors
with conventional diagnostic output as for those with a serial
diagnostic function.
The green LED indicates that the safety sensor is ready for operation.
The sensor is not actuated.
The yellow LED indicates the switching condition of the safety outputs.
The flashing can be used to prematurely detect variations in the
clearance between the sensor and the actuator (e.g. sagging of a safety
guard). The sensor must be adjusted before the distance to the actuator
increases and before the safety outputs are disabled, thus stopping the
machine. If an error is detected, the red LED will be activated.
Flash codes red diagnostic LED
LED indication (red) Error cause
1 flash pulse Error output Y1
2 flash pulses Error output Y2
3 flash pulses Cross-wire Y1/Y2
4 flash pulses ambient temperature too high
5 flash pulses Wrong or defective actuator
Continuous red Internal error
5.2 Operating principle of the electronic diagnostic output
Table 1: Examples of the diagnostic function of the safety-sensor with conventional diagnostic output
Sensor function LED
green red yellow
Diagnostic
output
Safety outputs
Y1, Y2
Note
I. Supply voltage On Off Off 0 V 0 V Voltage on, no evaluation of the voltage quality
II. actuated On Off On 24 V 24 V The yellow LED always signals the presence of an actuator
within range
III. Actuated, actuator
in limit area
On Off Flashes
(1Hz)
24 V pulsed 24 V The sensor must be adjusted before the distance to the
actuator increases and before the safety outputs are disabled,
thus stopping the machine
IV. Error warning,
sensor actuated
On Flashes On 0 V 24 V After 30 minutes if the error is not rectified
V. Error On Flashes On 0 V 0 V Refer to table with flash codes
The short-circuit proof diagnostic output can be used for central
visualisation or control functions, e.g. in a PLC.
The electronic diagnostic output signals faults before the safety outputs
are disabled, thus enabling a controlled shutdown.
The diagnostic output is not a safety-relevant output!
The closed condition of the safety guard, i.e. the sensor is actuated,
is indicated through a positive signal. If the sensor is operating near
the limit of its switching distance, e.g. due to the sagging of the safety
guard, the sensor will emit a 1 Hz cyclic signal before the safety outputs
are disabled.
The diagnostic output can also be used to detect clearance variations
between the sensor and the actuator in the same way as the yellow
LED.
An active fault causes the diagnostic output to be disabled. The safety
outputs are disabled after max. 30 minutes if the fault is not rectified.
The signal combination, diagnostic output disabled and safety channels
still enabled, can be used to stop the production process in a controlled
manner.
Error
Any error that does not immediately affect the functionality of the safety
sensor (e.g. the ambient temperature being too high, interference
potential at a safety output, cross-wire short) will lead to a delayed
shut-down.
After fault rectification, the error message is reset by opening and re-
closing the corresponding safety guard. The safety outputs enable and
allow a restart.
Error warning
The safety outputs are disabled after 30 minutes if the error is not
rectified. The signal combination, diagnostic output disabled and
safety channels still enabled, can be used to stop the production
process in a controlled manner.
7
CSS 34
Operating instructions
Safety sensor
EN
5.3 Safety-sensors with serial diagnostic function
Safety sensors with serial diagnostic cable have a serial input and
output cable instead of the conventional diagnostic output. If CSS
sensors are daisy-chained, the diagnostic data are transmitted through
the series-wiring of the inputs and outputs.
Max. 31 sensors can be wired in series. For the evaluation of the serial
diagnostics line either the PROFIBUS-Gateway SD-I-DP-V0-2 or the
Universal-Gateway SD-I-U-… are used. This serial diagnostic interface
is integrated as a slave in an existing field bus system. In this way, the
diagnostic signals can be evaluated by means of a PLC. The necessary
software for the integration of the SD-Gateway is available for download
at www.schmersal.net.
Detailed information about the use of the serial diagnostics
can be found in the operating instructions of the PROFIBUS-
Gateway SD-I-DP-V0-2 and the Universal-Gateway SD-I-U-….
Accessories SD interface
For ease of wiring and series-wiring of SD devices,
considerable accessories are available. Detailed information
is available on the Internet, www.schmersal.net.
The response data and the diagnostic data are automatically and
permanently written in the assigned input byte of the PLC for each
safety sensor in the series-wired chain. The request data for each
safety sensor are transmitted to the device through an output byte of
the PLC.
In the event of a communication error between the field bus Gateway
and the safety sensor, the switching condition of the safety output of the
safety sensor is maintained.
The following operational information is automatically and permanently
written in an input byte of the PLC for each CSS 34 sensor of the
series-wired chain
Bit 0: safety outputs enabled
Bit 1: safety sensor actuated, actuator identified
Bit 4: both safety inputs live
Bit 5: safety sensor actuated in hysteresis area
Bit 6: error warning, switch-off delay activated
Bit 7: error, safety outputs switched off
Error
A fault has occured, which causes the safety outputs to be disabled.
The fault is reset, when the cause is eliminated and bit 7 of the request
byte changes from 1 to 0 or the safety guard is opened. Faults at
the safety outputs are only deleted upon the next release, as the
fault rectification cannot be detected sooner. For devices with serial
diagnostic, a bit can be set/deleted in the call telegram to reset the fault.
For devices with serial diagnostic, a bit can be set/deleted in the call
telegram to reset the fault.
Error warning
A fault has occurred, which causes the safety outputs to be disabled
after 30 minutes. The safety outputs initially remain enabled. This
enables the shutdown of the process in a controlled manner. An error
warning is deleted when the cause of error is eliminated.
Diagnostic error (warning)
If an error (warning) is signalled in the response byte, detailed fault
information can be read out.
Table 2: Function of the visual diagnostic LEDs, the serial status signals and the safety outputs by means of an example
System condition LED Safety outputs serial diagnostic byte bit no.
green red yellow Y1, Y2 7 6 5 4 3 2 1 0
Supply voltage on, not actuated On Off Off 0 V 0 0 0 0 0 0 0 0
Actuated, safety outputs enabled On Off On 24 V 0 0 0 1 0 0 1 1
Actuated in limit area On Off Flashes
(1Hz)
24 V 0 0 1 1 0 0 1 1
Actuated, warning On On/
flashes
On 24 V 0 1 0 1 0 0 1 1
Actuated, fault On On/
flashes
On 0 V 1 1 0 1 0 1 1 0
The shown bit order of the diagnostic byte is an example. A different combination of the operational conditions will lead to a change of the bit order.
Table 3: I/O data and diagnostic data
Communication directions: Request byte: from the PLC to the local safety sensor
Response byte: from the local safety sensor to the PLC
Warning/error byte: from the local safety sensor to the PLC
Bit n° Request byte Response byte Diagnostic
error warning
Diagnostic
error
Bit 0: Error reset Safety output activated Error output Y1 Error output Y1
Bit 1: --- Actuator detected Error output Y2 Error output Y2
Bit 2: --- --- Cross-wire Y1/Y2 Cross-wire Y1/Y2
Bit 3: --- --- Temperature too high Temperature too high
Bit 4: --- Input condition X1 and X2 --- incorrect or defective actuator
Bit 5: --- Actuated in limit area Internal device error Internal device error
Bit 6: --- Error warning Communication error between the field
bus Gateway and the safety switch
---
Bit 7: Error reset Error (enabling path switched off) Operating voltage too low ---
The described condition is reached, when Bit = 1
8
Operating instructions
Safety sensor
CSS 34
EN
8. Appendix
8.1 Wiring examples
The application examples shown are suggestions. They however do not release the user from carefully checking whether the switchgear and its set-
up are suitable for the individual application.
Wiring example 1: Series-wiring of the CSS 34 with conventional diagnostic output
The voltage is supplied to both safety inputs of the last safety sensor of the chain (considered from the safety-
monitoring module). The safety outputs of the first safety sensor are wired to the safety-monitoring module.
X1
Y1
X2
Y2
12356 8
X1
X2
A1
A2
Y1
Y2
12356 8
X1
4
Y1
4
Y1
X2
7
Y2
7
Y2
OUT
A1
A2
OUT
SPS/PLC
24 VDC
GND
CST 34-S-1
CSS 34
CST 34-S-1
CSS 34
Safety outputs → Evaluation
Wiring example 2: Series-wiring of the CSS 34 with serial diagnostic function
The safety outputs of the first safety sensor are wired to the safety-monitoring module.
The serial Diagnostic Gateway is connected to the serial diagnostic input of the first safety sensor.
Field bus
1235468
X1
Y1
X2
SD IN
SD OUT
A1
A2
1235468
X1
Y1
X2
7
Y2
7
Y2
SD IN
SD OUT
A1
A2
X1
Y1
X2
Y2
SD INSD OUT
Y1
Y2
SD IN
24 VDC
GND
CST 34-S-1
CSS 34
CST 34-S-1
CSS 34
Safety outputs → Evaluation
Gateway
6. Set-up and maintenance
6.1 Functional testing
The safety function of the safety components must be tested. The
following conditions must be previously checked and met:
1. Fitting of the sensor and the actuator
2. Fitting and integrity of the power cable
3. The system is free of dirt and soiling (in particular metal chips)
6.2 Maintenance
In the case of correct installation and adequate use, the safety sensor
features maintenance-free functionality.
A regular visual inspection and functional test, including the following
steps, is recommended:
• Check the fitting of the safety sensor and the actuator
• Remove possible metal chips
• Check the cable for damage.
Measures must be taken to protect against manipulation or
against the bypassing of safety device, for example, using an
extra actuator.
Damaged or defective components must be replaced.
7. Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate
manner in accordance with the national prescriptions and legislations.
9
CSS 34
Operating instructions
Safety sensor
EN
8.2 Wiring configuration and connector accessories
Function safety switchgear Pin configuration
of the connector
5
8
4
3
2
1
7
6
Colour codes of the Schmersal
connectors
Poss. colour codes of other
customary connectors
or the integrated
cable
with conventional
diagnostic output
with serial
diagnostic function
IP67 / IP69
to DIN 47100
IP69K
(PVC)
to
IEC 60947-5-2: 2007
A1 U
e
1 WH BN BN
X1 Safety input 1 2 BN WH WH
A2 GND 3 GN BU BU
Y1 Safety output 1 4 YE BK BK
OUT Diagnostic output SD output 5 GY GY GY
X2 Safety input 2 6 PK VT PK
Y2 Safety output 2 7 BU RD VT
IN without function SD input 8 RD PK OR
Connecting cables with coupling (female)
IP67 / IP69, M12, 8-pole - 8 x 0.23 mm²
to DIN 47100
Connecting cables with coupling (female)
IP69K, M12, 8-pole - 8 x 0.21 mm²
Cable length Part number Cable length Part number
2.5 m
5.0 m
10.0 m
103011415
103007358
103007359
5.0 m
5.0 m, angled
10.0 m
15.0 m
101210560
101210561
103001389
103014823
10
EN
CSS34-F-EN
Operating instructions
Safety sensor
CSS 34
Place and date of issue: Wuppertal, 13. November 2019
Authorised signature
Philip Schmersal
Managing Director
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform
to the applicable European Directives.
Name of the component: CSS 34
Type: See ordering code
Description of the component: Non-contact safety sensor
Relevant Directives: 2006/42/EC
2014/30/EU
2011/65/EU
Machinery Directive
EMC-Directive
RoHS-Directive
Applied standards: EN 60947-5-3:2013
ISO 14119:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Notied body for the prototype test: TÜV Rheinland Industrie Service GmbH
Alboinstraße 56
12103 Berlin
ID n°: 0035
EC- test certicate: 01/205/5194.02/19
Person authorised for the compilation
of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
9. EU Declaration of conformity
The currently valid declaration of conformity can be
downloaded from the internet at www.schmersal.net.
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30, 42279 Wuppertal
Germany
Phone: +49 202 6474-0
Telefax: +49 202 6474-100
Internet: www.schmersal.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

schmersal CSS 12-34-V-SD-M-ST Operating instructions

Category
Gateways/controllers
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI