Brigade Electronics ZS-1000-SG (5886) User manual

Category
Car video systems
Type
User manual

This manual is also suitable for

1
ZoneSafe
User Manual
Tag Tester - ZS-1000-TT
Smart Gateway - ZS-1000-SG
www.brigade-electronics.com
2 3
Document Name
ZoneSafe Tag Tester Manual
Contents
1. Introduction 3
2. Tag Tester 4
2.1 How It Works 4
2.2 What’s In The Box 4
2.3Specication 4
2.4 LED Indicators 5
3. Smart Gateway 5
3.1 How It Works 5
3.2 What’s In The Box 5
3.3Specication 6
3.4LEDIndicators 6
4. Installation 7
4.1 Installation Consideration for all Devices 7
4.2 Fixings 7
4.3 Additional Brackets 8
4.4 Adaptor plates 9
4.5 Cable Entry 9
5. Wiring For Tag Tester & Smart Gateway 10
5.1 Tag Tester Range Adjustment 11
5.2 PoE Daughter Board Kit 12
6.Conguration&Settings 13
6.1NetworkConnection 13
6.2TagTester&SmartGatewaySettings 14
6.2.1General 14
6.2.2Alarms 14
6.2.3Date&Time 14
6.2.4Relays 14
6.2.5Inputs 14
6.2.6WebServer 14
6.2.7AccessControl 14
7. FCC Compliance Information 15
Information in this document is subject to change without notice.You do not have permission to reproduce, publish
or share any part of this document either electronically or printed in part or full without prior written consent from
Brigade Electronics.
1. Introduction
The Tag Tester and Smart Gateway are part of a modular ZoneSafe system and have the following uses:
Tag Tester : Detects ZoneSafe Tags and indicates to the user the battery status of a Tag, it also has network capability
and relays.
Smart Gateway : ‘The unit detects Antenna Units instead of tags and can either be part of our vehicle proximity system
or an Independent Antenna Unit.
4
5
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS DRAWI NG IS THE PROPERTY OF AND MAY EMBODY PROP RIETA RY INFORMA TION
OWNED BY AVONWOOD DEVE LOPMEN TS LTD. IT IS PROVIDED UNDER A CONFID ENTIAL
RELATION SHIP FOR A SPECIFIC PURPOSE. THE RECIP IENT AGREES TO USE IT ONLY FOR
SUCH PURP OSE.
AS IND ICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL POINT
DRILL POINT
DRILL POINT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTERY
28.00
14.00 14.00
1. Present the tag within range of the Tag
Tester (1 - 4m - adjustable).
2. The Tag Tester will read the battery level
of the tag.
3. The Tag Tester indicates to the user
whether the tag battery level is good (tick)
or has low battery (cross) on the front of
the unit.
The Tag Tester can also activate peripheral
devices using its relays.
2. Tag Tester
2.1 How It Works
2.2 What’s In The Box
Components
Tag Tester Power Supply
Unit
M12 Cable
Gland
M4 Screws (x 4) 2 Way Screw
Terminal
5 Way Screw
Terminal (x 2)
2.3 Speci cation
2.4 LED Indicators
• Power LED (Blue ashes 1sec on/o = normal
operation)
• BatteryOKLED(Green3secon=tagbatteryOK)
• BatteryLowLED(Red3secon=tagbatteryLow)
TAG BATTERY LEVEL IS GOOD
TAG BATTERY LEVEL IS LOW
The Tag Tester tests the status of any ZoneSafe
active tag. The unit reads a tag and displays the
status of the battery, using red or green indicator
LEDs and optional audible indicators. Daily use
of the tag test unit ensures tag batteries ok.
3. Smart Gateway
3.1 How It Works
In the example applications here it shows the wall
mounted Smart Gateway unit detecting a forklift
tted with a ZoneSafe proximity warning system
using Antenna Units. If proximity warning is not
required for the operator then an Independent
Antenna unit can be mounted to the vehicle to
trigger the Smart Gateway instead of a full system.
The Smart Gateway detects the Antenna Unit and
activates one or both of its relays which trigger, in
these examples, a barrier or projection light.
Contact us for further information.
Vehicle Access
Control Using a
Smart Gateway
and an
Antenna Unit
Warning Projector Lights
Using Smart Gateway and Antenna Unit
Tag Tester
Electrical Voltage
Power
24VDCInput(+/-5%
<10W
Mechanical Dimensions (incl. glands)
Material
Weight
Relay
Input
155x155x60(mm)
ABS/PC
.45kg
2x Rated Current 1A @30V
x1
Communications Ethernet 10-BaseT or 100-BaseTx
Environment Ingress Protection
Temperature
IP67(withnoholesdrilled)
-10
O
C to +50
O
C
Radio Transmit Frequency
Recieve Frequency
Range
125kHz
RegionSpecic*
Adjustable 1-4m approx.
Receive: 50m typ
POWER LED
*868.3MHz,902.4MHz,867.0MHz,919.0MHz
3.2 What’s In The Box
Component
Smart
Gateway Unit
Power Supply
Unit
M12 Cable
Gland
M4 Screws (x 4) 2 Way Screw
Terminal
5 Way Screw
Terminal (x 2)
6 7
The following considerations should be made before installation:
• No metal should be within 200mm of the top, bottom and
sides of the reader (see image on right).
• Nometalshouldbeinfrontoftheunit.
• Install power supply at least 1m away or greater.
• Make a note of the serial number located on the back of
the device. You will need this to set up and connect to the
network.
4. Installation
4.1 Installation Consideration for both
Devices
3.3 Speci cation
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS DRAW ING IS THE PROP ERTY OF AND M AY EMBODY PROPRIET ARY INFO RMATION
OWNED B Y AVONW OOD DEVE LOPMENTS LTD. IT IS PROVID ED UNDER A CONF IDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIP IENT AGRE ES TO USE IT ONLY FOR
SUCH PUR POSE.
AS IND ICATED IN ISO 2768-1
TOLERANCE CL ASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
HOLE FOR POE
HOLE FOR POE
CONN3
CONN2
CONN5 CONN1
HOLE FOR POE
CONN4
HOLE FOR POE
J4
J5
LD1
LD2
LD3
LD4
HARDWARE
ADDRESS
2
0
0
.
0
0
200.00 200.00
2
0
0
.
0
0
60.00 155.00
1
5
5
.
0
0
200mm
3.4 LED Indicators
The Smart Gateway oers visual and audible
indicators for both tag / vehicle detection & reader
status:
• Power LED (Blue ashes 1sec on/o = normal
operation)
• Antenna/VehicleDetectLED(Blueashes50ms
On=antennaunitdetected)
4.2 Fixings
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS D RAWING IS THE PROPERTY OF A ND MAY EMBODY PROPRIET ARY IN FORMATIO N
OWNED BY AVO NWOOD DEVELO PMENTS LTD. IT IS PR OVIDED U NDER A CONF IDENTIAL
RELATION SHIP F OR A SPECIFIC PURPOSE. THE RE CIPIENT AGREES TO U SE IT O NLY FO R
SUCH PURPOSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL POINT
DRILL POINT
DRILL POINT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTERY
28.00
14.00 14.00
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS D RAWING I S TH E PROPER TY OF AND M AY EMBO DY PRO PRIETA RY INFO RMATION
OWNED BY AVO NWOOD DEVELOP MENTS L TD. IT IS PR O VIDED UN DER A CONFID ENTIAL
RELATION SHIP F OR A SPECIFIC P URPOSE. THE RE CIPIENT AGREES TO US E IT ON LY FOR
SUCH PURPOSE.
AS INDICATED IN ISO 2768-1
TOLERANCE C LASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL PO INT
DRILL POINT
DRILL PO INT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTER Y
28.00
14.00 14.00
DRILL POINT
DRILL POINT
DRILL POINT DRILL POINT
AMPS
ThishastheoptionfordrillingthroughtheboxandxingusingscrewsorboltswhileretainingitsIPrating.
Maxscrew/boltsizeM4.
Smart Gateway
Electrical Voltage
Power
24VDCInput(+/-5%
<10W
Mechanical Dimensions (incl. glands)
Material
Weight
Relay
Input
155x155x60(mm)
ABS/PC
.45kg
2x Rated Current 1A @30V
x1
Communications Ethernet 10-BaseT or 100-BaseTx
Environment Ingress Protection
Temperature
IP67(withnoholesdrilled)
-10
O
C to +50
O
C
Radio Receive Frequency
Transmit Frequency
Range
125kHz
RegionSpecic*
Adjustable 3-9m approx.
*868.3MHz,902.4MHz,867.0MHz,919.0MHz
NOTE: ZoneSafe must be tted and commissioned by an approved installer. No responsibility will be
accepted for damage to systems caused by incorrect installation or misuse. Detection accuracy will
depend on environmental and installation factors.
200mm
200mm 200mm
READ LED
POWER LED
8 9
4.3 Additional Brackets
All ZoneSafe units come installed with four M5 threaded inserts in the AMPS hole pattern on the back. These can be
xedtodirectly,adapterplatescanbettedtothebackoftheunits,RAMmountscanbeusedandwealsohavea
rangeofadditionalbracketsallofwhichhavetheAMPSholeconguration.
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
AVONWOOD INTERNAL
PIVOTLOC
BRACKET SHARED
IMAGES
AS SHOWN
SHEET
N/A
A
A0
THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPR IETARY INFO RMATION
OWNED BY AVONWOOD DEVELOPMENTS L TD. IT IS PROVIDED UNDER A C ONFIDENTIAL
RELATIONSHIP FOR A SPE CIFIC PURPOSE . THE RE CIPIENT AGR EES TO U SE IT ONL Y FOR
SUCH PURP OSE.
MH
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDG
ES = f
1 / 1
UNLESS OTHERWISE STATED
EXPLODED VIEW
02 7125 - PIN BRACKET
BOLT
WASHER
NUT
WASHER
02 7124 - PLAIN BRACKET
UNLOCK
ROTATE TO NEW POSITION
LOCK POSITION
LOCK PIN
BUTTON HEAD M5X12
M5 SHAKEPROOF
M5 PLAIN WASHER
MAX TORQUE 1.6Nm
1
5
.
0
0
1
5
.
0
0
2
0
.
0
0
1
5
.
0
0
1
5
.
0
0
10.00
30.00
3
8
.
0
0
5.
80
8
0
.
0
0
58.00
HOLE POSITIONS
AND DIMENSIONS
OVERALL DIMENSIONS
80.00
9
6
.
0
0
68.90
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
POLE MOUNT
BRACKET IMAGES
SHEET
A2
THIS DRAWING IS THE PROPERTY OF A ND MAY EMBODY PROPRIETARY IN FORMATION
OWNED BY AVONWOOD DEVELO PMENTS LTD. IT IS PROVIDED UNDE R A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFI CPUR POSE. THE RECIPIENT AGREE S TOU SE IT ONLY FOR
SUCH PURPOSE.
AS IN DICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
1
0
0
.
0
0
77.00
40.23
2
4
.
7
5
1
9
.
5
0
The PivotLoc Bracket which
canberotatedandlockedo
in one of 11 angled positions.
The Pole Mount Bracket can be
used on poles with a diameter
of between 50-100mm with
the use of worm drive hose
clamps x2 or zip / cable ties
(not included).
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
AVONWOOD INTERNAL
PIVOTLOC
BRACKET SHARED
IMAGES
AS SHOWN
SHEET
N/A
A
A0
THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPR IETARY INFO RMATION
OWNED BY AVONWOOD DEVELOPMENTS L TD. IT IS PROVIDED UNDER A C ONFIDENTIAL
RELATIONSHIP FOR A SPE CIFIC PURPOSE . THE RE CIPIENT AGR EES TO U SE IT ONL Y FOR
SUCH PURP OSE.
MH
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDG
ES = f
1 / 1
UNLESS OTHERWISE STATED
EXPLODED VIEW
02 7125 - PIN BRACKET
BOLT
WASHER
NUT
WASHER
02 7124 - PLAIN BRACKET
UNLOCK
ROTATE TO NEW POSITION
LOCK POSITION
LOCK PIN
BUTTON HEAD M5X12
M5 SHAKEPROOF
M5 PLAIN WASHER
MAX TORQUE 1.6Nm
1
5
.
0
0
1
5
.
0
0
2
0
.
0
0
1
5
.
0
0
1
5
.
0
0
10.00
30.00
3
8
.
0
0
5.
80
8
0
.
0
0
58.00
HOLE POSITIONS
AND DIMENSIONS
OVERALL DIMENSIONS
80.00
9
6
.
0
0
68.90
Right Angle Mounting Bracket.
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A3
THIS DRAWI NG IS THE PR OPERTY O F AND MAY EMBO DY PROP RIETARY INFORMATION
OWNED B Y AVONWO OD DEVE LOPMENTS LTD. IT IS PRO VIDED UN DER A CONFIDENTIA L
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIP IENT AG REES TO USE IT ONLY FOR
SUCH PU RPOSE.
AS INDICA T ED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OT HERWISE ST ATED
4.4 Adaptor plates
An adaptor plate is available for all the units. These attach via four
countersunk M5 nylon patched screws.
The plate provides slots and holes on the sides, it is rubber backed to
prevent scratching. Two of these plates can be bolted back to back to
clamp between vertical fence railing, the rubber backing helping to grip
in place.
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A2
THIS DRAW I NG IS T H E PR OPER TY OF A ND MAY EMBODY PROP RIET A RY IN FORM ATION
OWNED BY AV ONWO OD DEVELO PMENTS LTD. IT IS PROVID ED UNDER A CONFIDE NTIAL
RELATION SHIP FOR A SPECIFI C PURPOSE. TH E RE CIPIE NT AGREES TO USE IT ONLY FOR
SUCH PUR POSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
4.00
3.00
RUBBER BACK
ALUMINIUM PLATE
6
.
6
0
5
.
5
0
4
.
5
0
4
0
.
0
0
5
.
5
0
VARIOUS FIXING HOLES AND SLOT
COUNTER SUNK AT TACHMENT HOLES
IN THE AMPS PATTERN.
1
3
8
.
0
0
190.00
AdaptorPlatettedtothePlusenclosure
• AlternativelyusetheAMPSholecongurationforRAMMountFixtures,use1.5”ballttings.
• BackxwiththefourAMPSholestosuityourapplication.
• Shake-proof washers are recommended and thread locking liquid can also be used.
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS DRAW ING IS T HE PROPER TY OF AND MAY EMBO DY PROPR IETARY IN FORMATIO N
OWNED B Y AVONW OOD DEVE LOPMENT S LTD. IT I S PROVID ED UND ER A CONF IDENTIAL
RELATION SHIP FOR A SPECIFIC P URPOSE. THE RECIP IENT AGR EES TO US E IT ONLY FOR
SUCH PUR POSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL POINT
DRILL POINT
DRILL POINT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTERY
28.00
14.00 14.00
DETAIL A
SCALE 1 : 1
SECTION B-B
SCALE 2:1
SECTION C-C
SCALE 2:1
VIEW D-D
SCALE 1 :3
A
B B
C C
D
1
1
2
3 4 5 6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A1
THIS DRAWING IS THE P R OPE RTY OF AND MAY EMBODY PROPRIETAR Y INFORMATION
OWNED BY AVONWOOD DEVELOPMENTS LTD. IT IS PRO VIDE D UNDER A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIPIENT AGREE S TO USE IT ONLY FOR
SUCH PURPOSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
30.00
3
8
.
0
0
3.00
7.40
12.00
1.60
5.40
3.00
1.60
10.00
M5 X 0.8mm PITCH
M5 INT T OOTH SHAKEPROOF
M5 PLAIN
FIXTURE
0.00
200mm
200.00
38.00
30.00
AMPS HOLE
CONFIGURATION
DETAIL A
SCALE 1 : 1
SECTION B-B
SCALE 2:1
SECTION C-C
SCALE 2:1
VIEW D-D
SCALE 1 :3
A
B B
C C
D
1
1
2
3 4 5 6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A1
THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPRIETARY INFORMATION
OW NED BY AVONWOOD DEVELOPMENTS LTD. IT IS PROVIDED UNDER A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIPIENT AGREES TO USE IT ONLY FOR
SUCH PURPOSE.
AS INDICAT ED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
30.00
3
8
.
0
0
3.00
7.40
12.00
1.60
5.40
3.00
1.60
10.00
M5 X 0.8mm PITCH
M5 INT TOOTH SHAKEPR OOF
M5 PLAIN
FIXTURE
0.00
200mm
200.00
DETAIL A
SCALE 1 : 1
SECTION B-B
SCALE 2:1
SECTION C-C
SCALE 2:1
VIEW D-D
SCALE 1 :3
A
B B
C C
D
1
1
2
3 4 5 6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A1
THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPRIETARY INFORMATION
OW NED BY AVONWOOD DEVELOPMENTS LTD. IT IS PROVIDED UNDER A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIPIENT AGREES TO USE IT ONLY FOR
SUCH PURPOSE.
AS INDICAT ED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
30.00
3
8
.
0
0
3.00
7.40
12.00
1.60
5.40
3.00
1.60
10.00
M5 X 0.8mm PITCH
M5 INT TOOTH SHAKEPR OOF
M5 PLAIN
FIXTURE
0.00
200mm
200.00
THREAD LOCK
M5 PLAIN
M5 INT TOOTH SHAKE-PROOF
M5 X 0.8mm PITCH
THREAD LOCK
RAM Mount Ball
Base Fixing Option
(examplexingnotincluded)
DRILL POINTS
Drill marks
Drill marks
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPRIETARY INFO RMATION
OWNED BY AVO NWOOD DEVE LOPMENTS L TD. IT IS PROVIDED UNDER A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RE CIPIENT AGREES TO USE IT ONLY FOR
SUCH PURPOSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL POINT
DRILL POINT
DRILL POINT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTERY
28.00
14.00 14.00
4.5 Cable Entry
• Supply24VDC+/-5%10WorusethePoweroverEthernet(PoEdaughterboardmoduleneeded-seepage12).
Use a suitable Cat5e data cable to connect comms.
• Runpoweranddataintoyourdeviceusingwaterproofcableglands,(Max16mmDiameter)orinternallythreaded
conduit (Max 20mm diameter). Only use the central drill point as indicated above.
• Holes can be made by drilling through one of the marked locations on the box.
• ForanIP67applicationuseratedglandsorenterthroughtheundersidewith suitably sealed conduit. Entry through
the back is possible but if ingress protection is needed then the entry hole must be suitably sealed.
NOTE:
Please make a note of the
serial number located on
the back of the device. You
will need this to set up and
connect to the network.
CENTRAL
DRILL POINT
PivotLoc Bracket Kit - ZSM7154-A Pole Mount Bracket Kit - ZSM7154-BRight Angle Bracket Kit - ZSM7154-C
P/NZSM6908-E
NOTE : Care should be taken when drilling holes through enclosure.
THE MAXIMUM THREAD ENGAGEMENT DEPTH OF 8MM MUST NOT BE EXCEEDED
10 11
5.0 Wiring For Tag Tester & Smart Gateway
SECTION B-B
SCALE 2 : 1
B B
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
HARDWARE
INSTALLATION
BOM REF:
A0
THIS DRAWING IS T HE P ROPERTY OF AND MAY EMBODY
PROPRIETARY INFORMATION OWNED BY AVONWOOD
DEVELOPMENTS LTD. IT IS PROVIDED UNDER A
CONFIDENTIAL RELATIONSHIP FOR A SPECIFIC PURPOSE.
THE RECIPIEN T AGREES TO USE IT ONLY FOR SUCH
PURPOSE.
DRILL POINTS A - M16 GLAND MAX
DRILL POINTS B - M20 GLAND MAX
DRILL POINT A
DRILL POI NT B
DRILL POINT A
DRILL POINT A
DRILL POINT A
DRILL POI NT B
DRILL POINT FOR
INSIDE FIXING
4.5mm HOLE MAX
DRILL POINT FOR
INSIDE FIXING
4.5mm HOLE MAX
DRILL POINT FOR
INSIDE FIXING
4.5mm HOLE MAX
DRILL POINT FOR
INSIDE FIXING
4.5mm HOLE MAX
M5 THREADED
INSERTS
POE PCB
POE HEADER
J5
2
0
0
.
0
0
200.00 200.00
2
0
0
.
0
0
2
0
0
.
0
0
200.00200.00
2
0
0
.
0
0
HARDWARE
ADDRESS
LD4
LD3
LD2
LD1
J5
J4
HOLE FOR POE
CONN4
HOLE FOR POE
CONN1CONN5
CONN2
CONN3
HOLE FOR POE
HOLE FOR POE
CONN1:ANT
(2 Way for Antenna)
PinNo. Description
1 Antenna -
2 Antenna +
CONN2:INPUT
(2 Way for Volt Free Contacts)
PinNo. Description
1 0V
2 Input +
CONN3 & 5 : RELAY 1 & 2
(5 Way)
Pin No. Description
1 0V
2 N/O
3 N/C
4 Common
5
+ 24V OUT
(100mA max)
CONN4:POWER
(2 Way for Power)
PinNo. Description
1 OVIN
2 +24VIN
RV1 - Range
Turn clockwise to increase the
detection range or anti-clockwise
to reduce the range
PCBLEDINDICATORS
ID Description Function
LD1 Ethernet Link
LEDisONwhenEthernetport
has a valid link
LD2 Ethernet Speed
LEDisONwhenEthernetisin
100Mbps mode
LD3 Ethernet Activity
LED blinks when there is activity
on the Ethernet port
LD4 Ethernet Duplex
LEDisONwhenEthernetisin
half duplex mode
J4ETHERNET(8Way)
PinNo. Description
1 BLUE/WHITE
2 BLUE
3 ORANGE/WHITE
4 ORANGE
5 GREEN/WHITE
6 GREEN
7 BROWN/WHITE
8 BROWN
VIEW A-A
SCALE 1 : 1
SECTION C-C
SCALE 1 : 1
A
C
C
1
1 2 3 4
5
6
A
B
C
D
E
F
REV: DATE: CHANGE:
STATUS:
CUSTOMER:
SCALE @
DRAWN BY:
REV:
DRAWING NO:
TITLE:
UNCONTROLLED
SHEET
A0
THIS DRAWING IS THE PROPERTY OF AND M AY EMBODY PROPRIETARY INFORMATION
OWNED BY AVO NWOOD DEVE LOPMENTS LTD. IT IS PROVIDED UNDER A CONFIDENTIAL
RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RE CIPIENT AGREES TO USE IT ONLY FOR
SUCH PURPOSE.
AS INDICATED IN ISO 2768-1
TOLERANCE CLASS
LINEAR = f
ANGULAR = f
BROKEN EDGES = f
1 / 1
UNLESS OTHERWISE STATED
POWER INDICATOR
DRILL POINT
DRILL POINT
DRILL POINT
DRILL POINT
AMPS
POWER INDICATOR
READ INDICATOR
155.00
1
5
5
.
0
0
60.00
GOOD BATTERY
BAD BATTERY
28.00
14.00 14.00
1
2
3
5
4
1
2
1
2
3
5
4
1
2
1
2
1
8
5.1 Tag Tester Range Adjustment
HOLE FOR POE DAUGHTERBOARD
(DAUGHTERBOARD)
(DAUGHTERBOARD)
12 13
ThePoE(PowerOverEthernet)DaughterBoardisttedtotheReaderPCBasshowninFigure4below.
5.2 PoE Daughter Board Kit
Please ensure that the plastic spacers are inserted correctly as per Figure 5 below.
For further information about ethernet wiring, please see page 5.
The range on the Reader can be adjusted to detect tags between 1 and 4 metres away. The adjuster is marked as RV1
onpage11.Usingaatheadscrewdriver,turntheadjustertochangethesizeofthedetectionzone.
• Turn the adjuster clockwise to increase the size of the detection zone
• Turn the adjuster anti-clockwise to decrease the size of the detection zone
Pleasenote-Maximumandminimumrangecanbeaectedbythemountinglocationoftheunitandpowersupply
ratings.
6. Conguration & Settings
6.1 Network Connection
AllReaders areshippedwithDHCP enabledand a DHCPname using theSerial Number ofthe device.TheSerial
NumbercanbeidentiedfromthelabelonthebackoftheReaderandthehardwareaddress.
When the device is connected to a network port it will be assigned an IP address from your network’s DHCP server if
available. To discover the IP address assigned to a particular device you will need to use the Lantronix Device Installer
software,whichcanbedownloadedfromhttp://www.lantronix.com.
Runthe“LantronixDeviceInstaller”softwarefromaPConthesamenetworkasTheReader.
It will automatically start searching for devices on the network.
Device Installer will show all devices located on your network. To identify the correct device from its
SerialNumber,double-clickadevicewiththename“xPico”.ThiswillshowaDeviceInfotab.Usethe
DHCPDeviceNamepropertyvaluetodetermineifthisisthecorrectdevice.
Having determined the correct device, note the IP Address assigned to it and open a web browser to
thataddress,forexamplehttp://10.0.0.121.Whenpromptedforausernameandpassword,leaveboth
eldsblankandclickOK.
SNAP IN NYLON SPACER
J5
POE HEADER
14 15
6.2 Tag Tester & Smart Gateway Settings
Once connected, the user can access the following Reader settings via the internal webpage:
6.2.1 General
TheGeneralSettingspagecontainstheprimaryusercongurableparametersofthedevice.
A tooltip is displayed when hovering the cursor over each setting explaining its purpose. Click the Save button for
changestotakeeect.
The Alarms page contains the alarm settings for the device.
A tooltip is displayed when hovering the cursor over each setting explaining its purpose. Click the Save button for changes to
take eect.
6.2.2 Alarms
TheDate&Timesettingsallowyoutocheckandsetthecurrentdate/timeonthedevice.Thisvaluewillbeusedto
recordthetimeofeventsandtagreads.ClicktheSavebuttonforchangestotakeeect.
6.2.3 Date & Time
6.2.4 Relays
The Relays page contains the relay settings for the device.
A tooltip is displayed when hovering the cursor over each setting explaining its purpose. Click the Save button for
changestotakeeect.
6.2.5 Inputs
The Inputs page contains the input settings for the device.
A tooltip is displayed when hovering the cursor over each setting explaining its purpose. Click the Save button for
changestotakeeect.
TheWebServerpageallowscongurationoftheHTTPsettingsforsendingeventdataandtagreaddatatotheMy
ZoneSafe website and retrieval of Access Control settings. A tooltip is displayed when hovering the cursor over each
settingexplainingitspurpose.ClicktheSavebuttonforchangestotakeeect.
6.2.6 Web Server
6.2.8 Access Control
The Access Control web page displays a list of RFID tag numbers that are permitted if the Access Control Mode is
enabled in the General settings (See section 11). Tag numbers can be manually added or removed using this page. The
Clear All Tags button will remove the complete list of permitted tags from the device.
Ifthe“GetAccessListEnable”optionisenabled,thesoftwarewillperiodicallyrequestalistofpermittedtagnumbers
for this device from the My ZoneSafe website.
7. FCC Compliance Information
Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttopart
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
ChangesormodicationstoZoneSafe™systemsnotexpresslyapprovedbyBrigadeElectronicsmayvoidtheuser’s
authority to operate the equipment.
FCCID:2ACWNZSR6663
16
www.brigade-electronics.com
4017
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Brigade Electronics ZS-1000-SG (5886) User manual

Category
Car video systems
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI