Moen 7030 User manual

Category
Sanitary ware
Type
User manual

This manual is also suitable for

Model Numbers
7025, 7030, 7034, 7037
87025, 87030, 87034 Series
U.S. Patent Pending
Other Foreign and Domestic Patents Pending
INS215A
OWNER’S MANUAL
Exclusively from
INS215A
1
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
PRODUCT FEATURES
Newly styled handle
and spout receptor
Filtered
water
button
Filtered
water outlet
Easy to replace
water filter
Electronic
filter life
indicator
Deck plate models
Deck ring model
INS215A
2
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
WELCOME TO MOEN
®
Congratulations! You’ve purchased the revolutionary
PureTouch
®
Classic Filtering Faucet System. This faucet is
designed to provide great tasting, cleaner water with just one
touch. To get the most enjoyment from your Moen PureTouch
Filtering System, please read all installation and operating
instructions carefully. With simple care and maintenance, the
PureTouch Filtering Faucet System will provide many years of
reliable performance. If you should have any questions, please
call us toll-free at 1-877-DRINK-H2O (1-877-374-6542).
TABLE OF CONTENTS
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Water Filtration Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . .3
Parts Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Filter Replacement Instructions . . . . . . . . . . . . . . . . . . . . . . .8
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
California Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Performance Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
WATER FILTRATION SAFEGUARDS
Your PureTouch
®
Classic
Filtering Faucet System integrates carbon block
filtration technology designed by Culligan
®
International into a faucet
spout. This technology is fast and effective at reducing contaminants
commonly found in water and is certified by NSF
®
International. The
PureTouch Filtering Faucet System and installation must comply with
State and Local laws and regulations. To ensure optimal operation of
your new Moen faucet, please read the following safeguards carefully.
MicroTech™ Filter Cartridges
MicroTech filter cartridges will reduce :
Chlorine, Taste and Odor (MicroTech 400, 600)
Lead (MicroTech 400, 600)
Cysts (Cryptosporidium, Giardia)(MicroTech 600)*
* The contaminants removed or reduced by this filter are not necessarily in your water.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters
that may contain filterable cysts.
MicroTech filter cartridges are designed for replacement after
dispensing 200 gallons of filtered water. Water conditions and usage
may affect filter life and water taste.
The electronic indicator will signal when filter replacement is necessary
(see page 9).
Use only MicroTech 400 or 600 filter cartridges with the PureTouch
Classic
Filtering Faucet System.
Filter flow rate = .4-.6 gpm at rated pressure (20psi min. - 125psi max.).
Water Temperature
Minimum/Maximum faucet operating temperature = 40° - 150°F.
CAUTION: Do not filter water above 100° F.
MicroTech Filter Flushing Instructions
New MicroTech Filter Cartridge: After installing a new filter into the
faucet, allow cold water to run through the filtered water outlet for 5
minutes to flush out any loose carbon particles. The filter life
indicator will alternately flash amber and green for the first five
minutes after the indicator is manually reset (see page 9) as an aid
in timing the filter flushing period.
Daily Use: Allow cold water to run through the filter for 10-15
seconds prior to first use. If the filter has not been used for several
days, run cold water through the filter for 60 seconds prior to use.
Questions
If you have any questions please call our toll-free helpline,
1-877-DRINK-H2O. Monday through Friday 8:00 a.m. to 8:00 p.m.
1-877-(374-6542) Saturday 8:00 a.m. to 6:30 p.m.
3
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
INS215A
INS215A
4
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
PARTS DESCRIPTION
1
4
5
6
7
8
9
10
30
17
16
18
19
20
15
24
28
25
26
27
13
14
3
2
12
11
31
31
21
22
23
DESCRIPTION
1
Solid Handle Body
2
Set Screw
3
Plug Button
4
Dome & Pivot
Retainer Assembly
5
Cartridge Screw
6
Handle Adapter &
Connector Assembly
7
Pivot Stop
8
Spout Retaining Nut
9
Bearing Washer
10
"D" Washer
11
Retainer Clip
12
1225 Cartridge
13
Filter Cartridge
14
Filltering Appliance
15
Lower Spout Assembly
16
Threaded Shank
17
Supply Tubes (2)
18
Bottom Bearing Washer
19
1/2" Threaded Fitting
20
Deck Ring with Gasket
21
Deck Plate
22
Mounting Bracket
23
Mounting Nut
24
Side Spray
(Spray Models)
25
Hose Guide with Gasket
(Side Spray Models)
26
Spray Hose
27
Extended Locknut
(Side Spray Models)
28
Swivel Nut (Spray Models)
29
Mounting Tool
30
Deck Plate
(Spray in Deck Models)
31
Support Plate with Gasket
29
5
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
INSTALLATION INSTRUCTIONS
CAUTION: Always turn water supplies OFF before removing existing
faucet. Turn faucet on to relieve water pressure and to ensure water is
completely off.
OLD FAUCET REMOVAL: Your old faucet may attach in a number of different
ways depending on the brand. To remove, reverse steps in installation
instruction sheet of old faucet, follow instructions in a DIY type of book or
follow instructions listed below.
After years of use, you may need to use a penetrating oil spray on the faucet
mounting hardware to help loosen corrosion and assist in removing the faucet
connections.
Disconnect water supply lines from faucet supply lines. Remove mounting
hardware using a basin wrench or channel lock pliers. Lift out faucet.
Thoroughly clean and dry the mounting surface after removal of old faucet.
INSTALLING THE PURETOUCH
®
Classic
FILTERING FAUCET SYSTEM
Helpful Tools: Phillips screwdriver, two adjustable wrenches
CAUTION: Do not use with portable washing devices, i.e.
dishwashers, washing machines.
NOTE: Do not bend supply tubes until instructed in step 4.
HINTS:
When using flexible supplies, we recommend threaded fittings be installed
onto supply lines before placing faucet through sink holes (see step 6). For
installations on tile countertops, remove rubber gasket from underneath support
plate (31) or deck ring (20) and apply a bead of putty in its place. Roll the putty into
the diameter of a pencil. When applied in the groove, the putty should protrude a
minimum of 1/16".
Side Spray Installation (side spray models only)
1. Locate foam gasket on hose guide (25) by sliding gasket onto shank and tucking
outer edge of gasket under the hose guide (25). Do not drive the center of the
gasket up into the hose guide. Install hose guide (25) through furthest left or
right hole in sink. From under sink, thread extended locknut (27) (either side
up) on shank of hose guide and tighten by hand. Feed spray hose (26) down
through the hose guide (25) (do not connect spray hose to faucet until step 6 ).
INS215A
25
25
27
26
2a. WARNING: Do not straighten bent supply tubes until
step 4.
DECK PLATE MODELS: Install faucet through deck holes
(threaded shank (16) to back). Center faucet on sink with
support plate (31) oriented in sink holes.
DECK RING MODELS: Place deck ring (20) over supply
tubes (17) and threaded shank (16) against bottom of
faucet body. Install faucet through deck hole (threaded
shank (16) to back).
FOR ALL MODELS
: Position spout to side to keep faucet
from tilting forward. Refer to step 2b for installation of
mounting bracket (22).
2b.
IMPORTANT: DECK THICKNESS (countertop)
Your deck thickness determines whether the mounting
bracket (22) is installed open side up or down. For spray
models, a groove on the threaded shank (16) indicates the
minimum amount of thread length which must be exposed for proper
attachment of nuts (23) and (28). For models without spray, a minimum of 1/2"
of threaded shank (16) must be exposed for proper attachment of nut (23).
Position mounting bracket onto threaded shank (16) and around supply tubes
(17). Do NOT kink tubing. Install mounting nut (23) and tighten by hand.
3. Be sure faucet is positioned evenly on sink. Make final tightening of mounting
nut (23) with mounting tool (29).
4. Carefully straighten each supply tube using two
hands. At this time, affix the Caution Hang Tag onto
either supply tube over the 1/2” threaded fitting (19).
If using flexible supply lines with compression fittings,
thread supply line nuts on finger tight, then holding
one threaded fitting with a wrench, tighten nut with
another wrench, rotating one half turn. Do not
overtighten. Connect the existing hot and cold water
supply lines to the two (2) 1/2” threaded fittings. The
hot supply tube is always to the left when threaded
shank (16) is positioned to rear.
INS215A
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
6
SINK
GROOVE
GROOVE
Back View of
Faucet Installation
SINK
For deck thickness over
1-1/8" deep, install
mounting bracket (22)
OPEN SIDE DOWN.
DECK RING
SINK
For deck thickness up to
1-1/8" deep, install
mounting bracket (22)
OPEN SIDE UP.
GROOVE
CAUTION:
Severe bends of the supply
lines may cause crimping
and restricted water flow
could result.
22
SINK
Deck ring
5. FOR MODELS WITH SPRAY IN DECK PLATE (30),
install spray hose (26) and spray head (24)
through deck plate hole.
6. TO CONNECT SPRAY HOSE FOR ALL SPRAY
MODELS:
Connect spray hose swivel nut (28) to the
threaded shank (16). Tighten swivel nut by hand
plus 1/4 turn with pliers or channel locks being
careful not to twist the spray hose (26). DO NOT
OVERTIGHTEN.
Flushing is required. See flushing instructions
below.
INS215A
7
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
26
24
LINE FLUSHING INSTRUCTIONS
IMPORTANT: Pipe chips, sand, stones and other solids found in new and
renovated plumbing can damage the sealing surfaces of the filter cartridge and
cause a leak. To avoid damage, DO NOT TURN ON SUPPLY VALVES until
instructed below.
Before you insert the filter and filtering appliance:
1. Turn faucet on in the full cold position (handle
pointing to the right) and allow cold water to flow
for 15 seconds
2. Without turning the faucet off, turn the handle to the full hot position (handle
pointing to the left) and allow hot water to flow for 15 seconds.
3. If side spray is installed, without turning the faucet off, turn the handle to the
mid/mix position (handle pointing toward you) and turn on the spray for 15
seconds.
4. Shut off faucet.
5. You are now ready to insert the filter and filtering appliance.
Sink
1. Install a new filter by wetting the outlet ports with
water and then inserting into the round filter ports
on the faucet head and pushing the filter and head
together. Both outlet ports must be
fully inserted into the filter ports.
2. Install the filter and faucet head
assembly on to the spout by wetting the
faucet head o-ring seal and rubber spacer and
then carefully sliding the free end of the filter
into the spout. The head will need to be initially
turned approximately 1/2 turn counter clockwise from
its normal position to slip past the safety catch. Lock the
head into place by simultaneously pushing and twisting the
head clockwise. When properly installed the head will feel
secure, and will be correctly oriented on the spout.
3. Reset the filter life indicator by pushing the filter
button 3 times. Wait 10 seconds. You should not be
running water while resetting the filter life indicator
because the filter button will remain depressed with the
first push as it switches to filter mode. The filter life indicator
has been correctly reset if a short series of rapidly flashing green
light occurs, indicating that the new filter flushing
period has begun.
4. Flush the filter (see page 3) for 5 minutes before
initial use.
Your new Moen faucet is now ready for normal use.
To replace or install filter -
1. Turn off the faucet. Remove the faucet head by
twisting it approximately 1/4 turn counter clockwise to
unlock it. Gently pull the faucet head away from the
spout and twist it approximately another 1/4 turn to get
the faucet head past the safety catch. The faucet head and
depleted filter (if one is installed) can now be pulled
completely out of the spout.
2. The filter is held to the faucet head by two outlet
ports, which connect into the head. Remove the old
filter by simply pulling it straight off. Discard the old filter
and install a new MicroTech 400 or 600 filter.
Note: The faucet will function correctly in unfiltered stream mode
with or without a filter installed. The faucet will not function correctly in
filter mode without a filter. If a filter is not installed and the filter button is
depressed, unfiltered water will flow from both the filtered water outlet and the
stream outlet aerator, and the filter button will not automatically stay depressed.
Use only Microtech 400 or 600 filter cartridges with the PureTouch
Classic
Filtering Faucet system. The Microtech filters are high performance carbon block
filters developed specifically for the PureTouch system.
Outlet Ports
Filtering Appliance
Faucet head o-ring seal
Filter
Spacer
MICROTECH
FILTER INSTALLATION/REPLACEMENT
INS215A
8
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
INS215A
9
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
OPERATING INSTRUCTIONS
Controlling The Water
The PureTouch system has two options for water delivery; unfiltered stream and
filtered water.
STREAM MODE
: Unfiltered water in regular stream flow.
When the water is turned on at the faucet, the spout will always begin
operating in the regular stream mode.
FIL
TERED WATER MODE: Filtered water dispensed through the separate
filtered water outlet.
Pressing the front filtered water button will divert water through the filter and
dispense filtered water from a separate outlet. To exit the filter mode, shut off
the faucet.
CAUTION: Only filter cold water. Do not filter water above 100° F.
Electronic Indicator
The flashing light on the electronic filter life indicator provides information
regarding the performance of the filter. The indicator provides you with
information throughout the life of the filter to help communicate the level at
which it is performing. Only reset the indicator when installing a new filter.
Resetting the indicator at any other time will cause incorrect filter life indication.
*If fast red doesn’t change to slow amber/green after memory has been reset,
reset was not complete and needs to be redone. Follow step 3 on page 8.
The electronic indicator is powered by a replaceable, standard 3V lithium watch
battery (2032) designed to last several years.
Battery Replacement
Follow filter replacement instructions to remove filter
appliance. Locate battery compartment drawer, pull out
and replace battery, positive side up. Keep the battery
and battery compartment dry. The electronic indicator
will retain the correct filter life information when the
battery is removed and replaced.
Indicator Color Performance
Amber & Green A new filter must be flushed with cold
water for 5 minutes after it is installed.
This procedure helps clean the filter of
loose carbon particles
Green Filter performing with optimum
efficiency
Amber Caution: Filter is ready for replacement
(approximately 16 gallons left).
Red Warning: Filter is ready for replacement
(approximately 8 gallons left).
Red (fast) Filter life is depleted, discard old filter
and replace with a new MicroTech 400
or 600 filter.
TROUBLESHOOTING
PROBLEM: Water flows from both outlets, filter and unfiltered, when the filter button is
pushed.
SOLUTION: No filter is installed, install a filter.
PROBLEM: After installing a new filter, the filter life indicator still flashes red.
SOLUTION: Filter life indicator was not reset, or the attempt to reset the indicator did
not work. Perform reset sequence.
PROBLEM: Reversed Hot & Cold positions.
SOLUTION: HELPFUL HINTS: IT IS NOT NECESSARY TO SHUT OFF WATER SUPPLIES.
HANDLE SCREW REQUIRES A 7/64” HEX KEY WRENCH.
1. Remove plug button (3) from the handle by prying the button
upwards from the bottom center. If a tool is required, use something
which will not scratch the handle. Remove set screw (2), handle body
(1), dome and pivot retainer assembly (4), cartridge screw (5), handle
adapter and handle connector assembly (6).
2. Turn cartridge stem around so that the notch is turned one half turn or
180°.
3. Reinstall as follows: Be sure retainer clip (11) is present on cartridge
stem and raised edge of pivot stop (7) faces front. Note orientation of
handle adapter & connector assembly (6 ) in the exploded view.
Completely tighten cartridge screw (5) to prevent unwanted closure
of faucet. Thread on dome clockwise until hand tight. Reinstall handle
body (1), set screw (2) and plug button (3).
PROBLEM: Faucet head is loose and water flows freely from between the head and
spout.
SOLUTION: The head was not locked in place correctly. Reinstall the head and filter
assembly.
PROBLEM: Slow or uneven water flow in filtered mode.
SOLUTION: Filter cartridge may be clogged with captured contaminants. Replace filter
cartridge. If problem persists call Moen Helpline at 1-877-DRINK-H2O
(1-877-374-6542)
PROBLEM: Electronic display doesn’t function.
SOLUTION: Replace battery.
PROBLEM: Irregular/low water flow
SOLUTION: Remove the areator from filtering head and flush thoroughly, then reinstall.
Moen aerators comply with government regulations to save both water and
energy. Your old faucet may not have met these standards.
PROBLEM: Faucet head spacer is mis-aligned
SOLUTION: Wet faucet head spacer prior to installing the filter and faucet head assembly.
If condition persists call Moen Helpline at 1-877-DRINK-H2O (1-877-374-6542).
TURN STEM
1/2 TURN
NOTCHED
FLAT
ON STEM
7
CARE AND MAINTENANCE
All that is needed to clean your faucet is a soft damp cloth. Moen does not
recommend the use of scour pads, cleansers or chemicals. The abrasive nature
of these substances could damage the faucet’s finish. A non abrasive car wax will
help to protect the finish. DO NOT SUBMERGE OR PLACE FAUCET HEAD IN
DISHWASHER.
INS215A
10
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
INS215A
11
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
PureTouch Classic Filtering Faucet System Warranty
Definitions:
“Faucet” - That part of the PureTouch Filtering Faucet System that includes the handle, spout receptor,
1225 cartridge, escutcheon, hose and mounting hardware (numbers 1-17 & 23-40 & 42 in parts
description (page 4)).
“Filtering Appliance” - The end of the faucet that includes the filter life monitor and push button (number
14 in parts description (page 4)).
“Filter” - That part of the PureTouch Filtering Faucet System that is to be replaced once 200 gallons of
water have run through the system (number 13 in parts description (page 4)).
Moen products have been manufactured under the highest standards of quality and workmanship. Moen
warrants to the original consumer purchaser that for as long as the original consumer purchaser occupies the
location of original product installation (the “Warranty Period”), that the Faucet (see definition for “Faucet”
above) will be leak and drip-free during normal use and all parts and finishes of the Faucet will be free from
defects in material and manufacturing workmanship (the “Consumer Faucet Warranty Period”). All parts and
finishes of the Filtering Appliance (see definition for “Filtering Appliance” above) will be free from defects
in material and manufacturing workmanship for a period of one (1) year from the original date of purchase
(the “Consumer Filtering Appliance Warranty Period”). All other purchases (including purchases for
industrial, commercial and business use) are warranted for a period of five (5) years from the original date of
purchase (the “Commercial Warranty Period”) for the Faucet (“Commercial Faucet Warranty Period”) and six
(6) months for the Filtering Appliance (“Commercial Filtering Appliance Warranty Period”). The Filter (see
definition for “Filter” above) is warranted to all purchasers to be free from defects in material and
manufacturing workmanship for a period of thirty (30 days) from the original date of purchase (“Filter
Warranty Period”).
If the Faucet should develop a leak or drip during the applicable “Faucet Warranty Period”, Moen will
FREE OF CHARGE provide the parts necessary to put the faucet back in good working condition and will
replace FREE OF CHARGE any part or finish that proves defective in material and manufacturing
workmanship under normal installation, use and service. If the Filtering Appliance should prove defective
in material and manufacturing workmanship under normal installation, use and service during the applicable
“Filtering Appliance Warranty Period”, Moen will FREE OF CHARGE replace any part or finish. If the filter
should prove defective in material and manufacturing workmanship under normal installation, use and
service during the “Filter Warranty Period”, Moen will FREE OF CHARGE replace the filter. Replacement
parts may be obtained by calling 1-800-289-6636 (1 -800-465-6130 in Canada), or by writing to the address
shown on the back of this booklet. Proof of purchase (original sales receipt) from the original consumer
purchaser must accompany all warranty claims. Defects or damage caused by the use of other than genuine
Moen parts are not covered by this warranty. This warranty is applicable only to faucets purchased after
February 1998 and shall be effective from the date of purchase as shown on the purchaser’s receipt.
This warranty is extensive in that it covers repair or replacement of defective parts and finishes for the
periods indicated. However, damage due to installation error, product abuse, product misuse or use of
cleaners containing abrasives, alcohol or other organic solvents, whether performed by a contractor, service
company or yourself, is excluded from this warranty. Moen will not be responsible for labor charges and/or
damage incurred in installation, repair or replacement, nor for any indirect, incidental or consequential
damages, losses, injury or costs of any nature relating to this product or its parts. Except as provided by law,
this warranty is in lieu of and excludes all other warranties, conditions and guarantees, whether expressed or
implied, statutory or otherwise, included without restriction those of merchantability or of fitness for use.
Some states, provinces and nations do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal
rights and you may also have other rights which vary by state, province or nation. Moen will advise you of
the procedure to follow in making warranty claims. Simply write to or call Moen. Explain the defect and
include proof of purchase and your name, address, area code and telephone number.
INS215A
12
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
Norme 53 : Effets sur la santé (PureTouch avec MicroTech 400, 600)
Réduction de kyste
Réduction de plomb
Lead Reduction
FEATURES
Refines treated water to premium quality
All filters take out disinfectant chlorine
MicroTech™ 600 reduces parasitic protozoan cysts including
Giardia &
,
Cryptosporidium
All filters absorb common earthy, moldy, fishy tastes and odors
with MicroTech™ 600 FIlter or MicroTech™ 400 (Chlorine & lead only)
PERFORMANCE CERTIFIED BY NSF/ANSI*
Average Average
USEPA Challenge Effluent
Average
Percent
Parameter MCL mg/L mg/L
Reduction
AESTHETIC EFFECTS
Chlorine — 2.0 0.35
93.3
Taste and Odor
HEALTH EFFECTS
Lead @ 8.5 pH (MicroTech 400)
Lead @ 8.5 pH (MicroTech 600)
.015
.015
.15
.13
.011
.006
94.6
97.7
Cysts (3-4 um particles)
1,055,000 particles
45
particles
99.99
*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH
=
7.5 ±
.05; temp. = 68° ± 5°F, 20° ± 2.5°C except where noted.
OPERATING SPECIFICATIONS
Capacity: MicroTech 600 and 400 Filters
certified for chlorine, taste and odor, and lead reduction for up to 200 gallons (750 L)
Pressure requirement: 20-125 psi (0.7 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Flow Rate: 0.5 gpm (1.89 Lpm)
GENERAL INSTALLATION/OPERATION/MAINTENANCE REQUIREMENTS
Flush to drain for 5 minutes at full flow.
Replace filters when capacity is reached, or when flow becomes too slow.
SPECIAL NOTICES
Installation instructions, parts and service availability, and warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter
cartridges. List price of MicroTech 600 filter is $20.00. List price of MicroTech 400 filter is $16.00. Consumer price varies by retailer.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not
necessarily in your water.
Check for compliance with state and local laws and regulations.
Filter life indicator runs on a standard 3V lithium watch battery (2032).
Faucet warranted for lifetime on leaks,drips and finish defects, filtering head warranted for one year, filter warranted for 30 days.
See Owner's Manual for commercial warranties.
The electronic filter life indicator will change from green to red when cartridge needs replacing. See the PureTouch System Owner's
Manual for additional electronic filter life indicator information.
Standard No. 42:
Aesthetic Effects (PureTouch w/MicroTech 400, 600)
Chemical Unit - Unité chimique - Unidad química
Chlorine Reduction, Class I
Taste and Odor Reduction
Standard No. 53:
Health Effects (PureTouch w/MicroTech 400, 600)
Cyst Reduction
NSF INTERNATIONAL STANDARDS
The PureTouch Filtering Faucet System has been tested and Certified by NSF only for the functions listed immediately above.
Le système de robinet avec filtre PureTouch a été testé et homologué par NSF seulement pour les fonctions précitées.
El Sistema de Mezcladora Filtradora PureTouch ha sido comprobado y Certificado por la NSF únicamente para las funciones indicadas inmediatamente arriba.
NSF's Certification Program is
accredited by the American
National Standards Institute
Lead @ 6.5 pH (MicroTech 600) .015 .17 .013 96.5
ANSI
ACCREDITED
CERTIFICATION
PROGRAM
Water usage or quality may affect filter life.
Maximum
Effluent
mg/L
0.006
0.008
0.003
24 particles
Minimum
Percent
Reduction
92.3
92.7
95.3
99.95
.14
82.5
NORMES INTERNATIONALES NSF
ESTÁNDARES INTERNACIONALES DE LA NSF
Norme 42 Effets visuels : (PureTouch avec MicroTech 400, 600)
Estándar No. 47 Efectos Estéticos (PureTouch con MicroTech 400, 600)
Réduction de chlore, Classe 1
Réduction de goût et d’odeur
Reducción de cloro, clase I
Reducción de olor y gusto
Estándar No. 53 Efectos en la salud (PureTouch con MicroTech 400, 6000)
(600 only) (600 seulement) Reducción de quistes
Reducción de plomo
Lead @ 6.5 pH (MicroTech 400) .015 .15 0.002 .003 98.8 98.0
NSF's Certification Program is
accredited by
the Dutch Council for Accreditation
Tested and Certified
to ANSI/NSF
Standards 42 & 53
NSF®
For purchases made in Iowa: This form must be signed and dated by the buyer and seller prior to
consummation of this sale.This form should be retained on file by the seller for a minimum of two
years.
Buyer____________________________________ Seller ____________________________________
Name_____________________________________Name____________________________________
Address___________________________________Address__________________________________
City_____________________State____Zip_______City_____________________State___ Zip _____
Signature______________________ Date________Signature_______________________ Date______
PureTouch
®
ClassicFiltering Faucet System
INS215A
4
HELPLINE: 1-877-DRINK-H2O
1-877-(374-6542)
PARTS DESCRIPTION
1
4
5
6
7
8
9
10
30
17
16
18
19
20
15
24
28
25
26
27
13
14
3
2
12
11
31
31
21
22
23
DESCRIPTION
1
Solid Handle Body
2
Set Screw
3
Plug Button
4
Dome & Pivot
Retainer Assembly
5
Cartridge Screw
6
Handle Adapter &
Connector Assembly
7
Pivot Stop
8
Spout Retaining Nut
9
Bearing Washer
10
"D" Washer
11
Retainer Clip
12
1225 Cartridge
13
Filter Cartridge
14
Filltering Appliance
15
Lower Spout Assembly
16
Threaded Shank
17
Supply Tubes (2)
18
Bottom Bearing Washer
19
1/2" Threaded Fitting
20
Deck Ring with Gasket
21
Deck Plate
22
Mounting Bracket
23
Mounting Nut
24
Side Spray
(Spray Models)
25
Hose Guide with Gasket
(Side Spray Models)
26
Spray Hose
27
Extended Locknut
(Side Spray Models)
28
Swivel Nut (Spray Models)
29
Mounting Tool
30
Deck Plate
(Spray in Deck Models)
31
Support Plate with Gasket
29
Brevet américain
Autres brevets nationaux et étrangers en instance
Numéros de modèle
7025, 7030, 7034, 7037
87025, 87030, 87034 Series
INS215A
GUIDE D’UTILISATION
Exclusively from
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Moen 7030 User manual

Category
Sanitary ware
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages