Installation
& Servicing
Instructions
THESE INSTRUCTIONS
TO BE RETAINED
BY USER
Vokèra is a licensed member of the Benchmark scheme
which aims to improve the standards of installation and
commissioning of domestic hot water systems in the UK.
Neutro
Wood pellet boiler
DearCustomer
Firstofallwewouldliketothankyouforthetrustyouhaveplacedinuswhenpurchasingoneof
ourproducts.
Wehavepreparedthisshortmanualforyouinanattempttomakeitaseasyaspossibleforyou
touseourproduct.
We
also advise youtoshowthespecifictechnicalinformation given onthefollowing pages to
those in charge of assembling the unit and making the product operational so that these
operationscanbecarriedoutascorrectlyaspossible.
LISTOFCONTENTS
Chapter1Introduction

1.1 Productsizeandconstructionfeatures
1.2 Producttechnicalfeatures
1.3 Fuelfeatures
Chapter2Installation
2.1 Indoorpositioning
2.2 Fumeextractionfluefeatures
2.2.1 Outsidewallextraction
2.2.2 Roofextractionbymeansoftraditionalflue
2.3 Hydraulicconnectionfeatures
2.4 Controlboardwiringdiagram
2.5
Productcoveringassemblyinstructions
Chapter3Useoftheproduct
3.1 Controlpanel
3.2 Lightingforthefirsttime
3.3 Conditionsforuse
3.4 Safetydevices
3.5 Usermenu
3.6 Onewayradiocontrol
Chapter4Maintenance
4.1 Scheduledmaintenance
4.2 Yearlymaintenance
4.3 Unscheduledmaintenance
4.4 Troubleshooting
Theseinstructionscoverthebasicprinciplestoensurethesatisfactoryinstallationofthe
stove,althoughdetailmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentBuildingRegulations,LocalAuthority
Byelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
ItshouldbenotedthattheBuildingRegulationsrequirementsmaybemetbyadoptingthe
relevantrecommendationsgiveninBritishStandardsBS8303,BS6461andEN123911
(replacingBS7566whichhasbeenwithdrawn)asanalternativemeanstoachievean
equivalentlevelofperformanceto
thatobtainedfollowing theguidancegiveninApproved
DocumentJ.
PleasenotethatitisalegalrequirementunderEngland andWalesBuildingRegulationsthat
theinstallationofthestoveiseithercarriedoutunderLocalAuthorityBuildingControl
approvalorisinstalledbyaCompetentPersonregisteredwitha
Governmentapproved
CompetentPersonsScheme.HETASLtdoperatesuchaSchemeandalistingoftheir
RegisteredCompetentPersonscanbefoundontheirwebsiteat
www.hetas.co.uk.
PREAMBLE
Wewouldliketohelpyouunderstandourmanualbylistingbrieflythemeaningofthesymbols
characterisingthemostimportantandsignificantinformationgiven:
Warningsandsafety
Importantinformation
Themanufacturerdeclinesanyliabilityforanydamagecausedtopeopleorpropertybecauseof
failuretoobservethesimplerulesofinstallationanduse,describedin thismanual.
You are also reminded that in installing the product you must observe relevant national and
localbuildingregulations.
Inpursuingcontinuousimprovement ofitsproductsandcustomersatisfaction,the
manufacturerreservestherighttomakeallnecessarymodificationstoimprovethequalitylevel
ofitsproducts,withoutpriornotice.
1. INTRODUCTION
1.1PRODUCTSIZEANDCONSTRUCTIONFEATURES
Weshowbelowthemaindimensionsofthepelletheater.

 

 

TypicalDimensions
Height 1015mm
Width 580mm
Depth 585mm
Weight 230kg
Fumeoutletdiameter 80mm
Airintakediameter 45mm
Waterpipediameter ¾”
Tankcapacity 28kg
Boilercapacity 10litres
Figure1.1.: Productsize
1.2 PRODUCTTECHNICALFEATURES
Our products are in conformity with BS EN 13240/2001 (solidfuel household equipmen t) and
subsequentamendments,andalreadyinlinewiththedraftofEuropeanstandardBSEN14785
(pelletheatinghouseholdequipmen t).
Theyarealsoinaccordancewithlegalprovisions,thatincorporatethefollowingdirectives:
‐ 89/336EEC(EMCdirective)andsubsequentamendments;
‐ 73/23EEC(lowvoltagedirective)andsubsequentamendments;
‐ 89/106EEC(fitnessforuse)andsubsequentamendments.
Belowisashortandsimplenoteonthemainperformancesandfittingsofourproduct:
PERFORMANCE
Min 4.7Ratedheatinput[kW]
Max 14.5
Min 3.5Overallheatoutput[kW]
Max 11.9
Min 3Outputtoheatingsystem[kW]

Max 10.3
Min 0.5OutputDirecttoroom[kW]
Max 1.6
StartUp 352Powerrequirements[W]
Rated 154
Maximumworkingwater
pressure[bar]
2
Maximumtemperatureinside
theboiler(°C)
80
CombustiongastemperatureºC 170
Massflowofgasesburnt[g/s] 14.8
Minimumdraught[Pa] 10
COvalues[%] <0.04
Max.heatablevolume[m
3
] 320*
Min 73.5Overallefficiency[%]

Max 81.5
Min 1Pelletconsumption[kg/h]
Max 3.1
atnominalflow 9Autonomy[h]
atminimum 28
Boilercapacity[litres] 10
MAINFITTINGS
Controlledcombustionsystemwithfumetemperaturerecovery Serial
Fumedraughtcontrolpressurestat Serial
Dualcombustionsystem Serial
Airtightchamberoperation Serial
Selfcleaningglass Serial
Onewayradiocontrol Serial
Automaticrelightingintheeventofblackout Serial
Possibilityofsettingpower(5levels) Serial
Weeklyprogrammer Serial
Twowayradiocontrol Optional
GSMmodule Optional
*values calculated on the basis of act 10/91 for rooms with thermal requirement of 30 kcal/hm
3
and
heightof3m.Thedatagivenaboveareapproximate;theproducercompanyreservestherighttomake
anychangeinordertoimprovetheproduct’sperformance.
The results in the table were obtained using certified pellet based on Austrian and German
standardsDIN51731,DINPLUSandÖNORMM7135.
You are reminded that the ESC (European Standardisation Committee) is in the process of
definingfutureEuropeantechnicalstandardsthatwillgovernboththetechnicalfeaturesof
this
fuelandtheeconomicandenvironmentalaspectsassociatedwiththeproductionline.
1.3 Fuelfeatures
The main feature of this heater is that it burns a natural fuel (the pellet) obtained in an
environmentallyfriendly way from scraps of the timber industry (wood chippings, sawdust,
etc.).
Woodchippingsandsawdustfromwoodproducts,afterhavingbeendulyrecleanedanddried,
are
compactedinstateoftheartveryhighpressureplants,intopureroundedwoodpieces:the
pellet.Eachroundedpiececanhavevariablelengthsandthicknesses,respectivelybetween1÷3
cm in length and 6÷8 mm in diameter. The pellet’s main features are low moisture content
(below 12%), its high de nsity (=600
kg/m
3
0 as well as its regularity and compactness that give
thistypeoffuelcharacteristicsofhighcalorificpower(I.C.P.4000÷5000kcal/kg).
Figure1.1:Woodinpelletform.
The pellet to be used to feed the hea ter must have high quality characteristics such as, those
defined by standards DIN 51731 and ÖNORM M 71 35, some basic details of which we set out
below.
Qualitystandardfor
woodinpelletform
Unitofmeasurement
ÖnormM7135
DIN51731
DINplus
Diameter Mm from4to10 from4to10 from4to10
Length Mm 5xD
1
<50 5xD
1
Density Kg/dm3 >1,12 1,0/1,4 >1,12
MoistureContent % <10 <12 <10
Ashes % <0,50 <1,50 <0,50
CalorificPower Kwh/kg >5 4.86/5.42 >5
Sulphur % <0,04 <0,08 <0,04
Nitrogen % <0,3 <0,3 <0,3
Chlorine % <0,02 <0,03 <0,02
Powders %weight <2,3‐ <2,3
Bindingagents %ofpressedmass <2 2 <2

1
Notmorethan20%ofthepelletmayhavealengthgreaterthan7.5timesitsdiameterD.
2
TheDINprohibitstheuseofanyaddedsubstance.However,thisprohibitionisnotvalidforsmallheatingsystems.
DINplusproposesthecombinationofthequalitativeparametersproposedbystandardDIN
51731andbyAustrianstandardÖnormM7135.
Thepellet,asalsostipulatedbycurrentItalianlegislationgoverningthecommercial
technology characteristics of fuels (DPCM 2.10.1995) must be produced exclusively with
untreatedwoodchippings,withnootheraddedmaterials.
Itisstrictlyprohibitedtouseanysolidorliquidfuelotherthanthepelletto
feedthestove.
Inordertooptimisetheuseoftheproductwerecommendusingpelletswhich
havebeen given a quality certificate by an authorised body. The use of pellets other
than those directed by the installer may lead to heater malfunction and to the
guaranteebecominginvalid.
Storingandevenmoving
thepelletsareimportantoperationstobecarriedoutwithcare:
Thefuelmustbestoredinadryplaceawayfromcold;
Thepelletsmustbemovedsoastoavoidexcessive 
crumblingintofinedust.
Observance of these two simple rules makes it possible
both to obtain better fuel
efficiencyandtopreservethemechanicalmovingpartsoftheapparatus.
Iftheproductiskeptoutofserviceforlongperiodsoftime(overfifteendays),the
tankmustbeemptiedofanyresi dual fuel,inordertopreventanyexcessive
dampnessofthefuelcausingtheproducttomalfunction.
Ahighmoisturecontentinthepelletmaycauseittocrumbleintodust,thatcreates
agreateraccumulationofresidueinthebr azierareaandblockageofthefuelfeed
system(auger).
2INSTALLATIONINS.
Foracorrectinstallationoftheheaterandtopreventtheuprisingofpossibleproblemsduring
running the heater, we are supplying some simple recommendations for the installation
accordingtoregulationsUNI10683,UNI9615,UNI9731,UNICIG7129andfollowingupdating
referredtodomestic
gasuseunits.
2.1Indoorpositioning
Ourproductisaheaterthatdrawsairthatisnecessaryforitscombustionprocessdirectlyfrom
theenvironmenttobeheated.
For this reason and for the even more important reason of safety for the people using it, the
heater must be installed in a sufficiently ventilated place in
order to guarantee a continuous
flowofairatalltimes.
Itisthereforeessentialtomakeairventsconnectedtotheoutside.Seeexampleinfigure2.1
DetailA
Figure2.1:Exampleofmakinganairvent.
IncompliancewiththeindicationsreportedunderregulationUNI10683,the
airinletsmusthavethefollowingfeatures:
1.Theymusthaveaclearspaceofnotlessthan80cm
2
;
2.Theymustbemadeataheightclosetothefloor;
3.They must be suitably protected by a wire mesh or grille in such a way
thattheminimumpassagespaceisnotandmaynotbereduced;
4.They must be placed in such a way that they are not
obstructed in
anyway.
The correct inflow of fresh air may be guaranteed by usi ng apertures
towardsanadjacentroom,providedthatithasdirectventilation,and
itisnotanenvironmentwithafirehazard,suchas storerooms, garages
or warehouses,asregulatedbyregulationUNI10683
Our heater should be installed
in rooms where there is no equipment operating in airtight
conditions inrelation tothe room, or apparatusthat may place the roomitself ina vacuum in
relationtotheoutsideenvironmentandthuscauseproblemsofpoordraughtforourproduct(
regulationUNI10683).
Combustionproductsfromourheatermustnotbeextractedintosharedfl ues.
Whencheckingequipmentcompatibility,itisgoodpracticetocheckwhetherthesupportplane
(floor)hasa bearing capacity (kg)that is suitedto theweightof theproduct itmustsustain. If
not,correctsafetymeasuresmustbetaken(eg.Loaddistributionplate).
Wheninstalling
theheater,itisadvisabletoplanasuitabledistancefromthewallsoftheroom
inordertoprovideanyaccessnecessarybothintherear(atleast20cmisrecommended)and
to the side of the product (80 cm is recommended) (for example to carry out appropriate
cleaning
workcorrectly).
Havingplaced theoutermostoverall part ofthe heaterat adistance of80 cmfrom
combustible and/or flammable material, if this distance cannot be maintained it is
useful to arrange for heat protection to be provided ( regulations UNI 7129 , UNI
10683)
Do not get close to, and above all do not touch with flammable material the outer
surfaces of the combustion chamber that, after continuous product use, may reach
hightemperatures.
Once the installation has been completed , pay attention in placing the
power switch in a position which will allows an easy and comfortable
access.
If the floor is made of combustible material (eg. parquet), it is advisable to protect it using a
sheetofnoncombustiblematerialplacedunderneathandaroundtheheater.
Figure2.2:Positioningdistances.
2.2Fumeextractionfluefeatures
Themainfeaturescharacterisingthefumeextractionfluearegiven.Theyarebasedonwhatis
setoutinstandardsUNI7129andUNI10683/98:
‐ Inspectionvalves(I);
‐ Minimum height of the pipe directly connected to the heater fume extraction outlet
mustbebetween2‐3m;
‐ If
itisnecessarytohaveahorizontalsection,itisadvisabletomakeitwith amaximum
lengthof1.5mandwithaninclineof3‐5%inordertohelpthefumestoescape;
‐ Useofacowlthatiswindresistantand rainresistantinorderto
avoidachangeinthe
slightconditionofoverpressuretheflueisin,(itisstronglyrecommendednottousea
horizontalsectionattheendoftheflue).
The reduction in pressure in the flue is necessary so as to help the normal flow of
fumes from the combustion chamber towards the outside, in the event of a mains
powercut.
Remember that excess heat disposal is managed in an optimum way from the
electroniccontrolpanel(modulation,switchoffstage,etc.).
‐ Flues must be made of appropriate materials to resist combustionproducts and
condensation(theinspectionvalvesshouldallowtodischargepossiblecondensation)
‐ The flues must be manufactured
in order to insure the maximum smoke resistance
(regulationUNI10683/98)
‐ Ductinsulationparticularlyontheoutsidepartexposedtotheweather.
Avoidmakingcompletelyhorizontalsections.
Figure2.3:Fumeextractionflue
Intheroomwheretheheatgeneratormustbeinstalled,theremustbenofume‐
extractionhoodsalreadyinexistenceorinstall ed,inordertoavoiddepressingthe
atmosphere.
Theairventsmustnotbeclosed.
Keeptheflueclean,performingacleaningoperationatleastonceayear;itisalso
advisabletocleanboththefluecowlandthefumepipeconnection.
2.2.1Outsidewallextraction
Oneoftheinstallationsolutionsthatmaybeadoptedisthatofplacingthepelletheatercloseto
anoutsidewalloftheroomsothatthefumesareextracteddirectlytotheoutside(figure2.4).
Hereafter please find some recommendations reported under regulation UNI 7129 referred to
thisparticular
plant:
‐ Always guarantee that there is an inspection va lve (I) that will allow effective and
periodiccleaningtobecarriedout,andanycondensationformedtobeeliminated;
‐ Thecowl(T)mustbestrictlywindproofandrainproof;
‐ Insulatethefumeextractionflueappropriatelyinthesectionwhereitgoes
throughthe
wall.
Thefumeextractionfluethatiscompletelyoutsidemustbemadeofdoublewallstainlesssteel
in order to guarantee that there is both greater resistance to atmospheric agents and correct
fumeextractiontemperature.
Figure2.4:Outsidewallextraction
2.2.2Roofextractionbymeansofatraditionalflue
Pelletcombustionfumesmaybeextractedalsousingapreexistingtraditionalflue(figure2.5),
providedthatitismadetostandard(refertostandardUNI10683).Belowisa shortlistofsome
ofthemainfeaturesgiveninthestanda rdthatcharacteriseagoodchimney(C):
‐ Suitable insulation
and proofing particularly in its outer section that is exposed to the
weather;
‐ Uniforminternalsection(theremustbenosectionrestrictions);
‐ Made of material that is resistant to high temperatures, the action of combustion
productsandthecorrosiveactionofanycondensationformed;
‐ Predominantlyverticalcoursewith
deviationsfromtheaxisofnomore than45°;
Itisadvisabletoprovideforachambertocollectsolidmatterandanycondensation(R)thatcan
beinspectedbymeansofanairtightwindow(I).
Figure2.5:Extractionbymeansofatraditionalflue.
WerecommendtofollowindicationsreportedunderregulationsUNI9615and9731referredto
dimensionsofthechimney(C)andhowevertoavoidusingsectionssmallerthan100mm.
In the case where there are larger sections, it is necessary to insert a steel pipe (A) inside
the
masonryone(C),asshowninfigure2.6.

Thesteelfluepipemustbesuitableinsulatedwithahightemperatureresistantrock
woolorvermiculitematerial(B).
Figure2.6:Exampleofextractionflueconnection.
Inthecaseoffireintheextractionflueorduct,switchoffthe heater
immediatelyanddisconnectitfromthehousemainspowersupply.
2.3ConnectiontoCentralheatingsystem
Inordertobeabletooperate,theheatermustbe suitablyconnectedtoaheatingsystem.For
this type of installation also, some simple suggestions are provided that will undoubtedly be
helpfulwheninstallingtheproduct(refertoregulationUNI10412andfollowingupdating)
Thedrainagecockisplacedatthelowestpointofthewatercircuit.
 Werecommendtoinstalltheballvalveonthedeliverywaterpipeandonthereturn
waterpipe(pleaserefertotheenclosedschematicdrawing).Thiswillenableaquick
andeasymaintenanceoperationincaseofneed.
Allwaterheatinginstallationsshouldbedesigned,beforeproductinstallation,
andinstalledbya
competentheatingengineerinaccordancewithBS5449:1990;CodeofPracticeforCentral
HeatingSystemsforDomesticPremises.Furtherguidanceisavailablefromthefollowing
sources:BSEN14336:2004HeatingSystemsinBuildings.Installationandcommissioningof
waterbasedheatingsystems.BSEN12828:
2003;HeatingSystemsinBuildings.Designofwater
basedheatingsystems.BSEN12831:2003;HeatingSystemsinBuildings.Methodforcal culation
ofthedesignheatload.
The ball valve mounted on the inlet pipe must be open in normal system operating
conditionsinordertoallowwatertobeaddedtotheboiler.Itmaybeclosedwhenit
isnecessarytodrainthesystem.
Thedeliveryandreturnpipeshaveadiameterof¾".
Thecorrectfunctioningoftheexpansionboxopenrequiresthattheexpansionbox
isplacedataheightnotlessthan7metersinrespecttothestove.
Theexpansionvesselmustbemadeofacoveredvessellocatedabovethehighestpointreached
bythewaterin
thesystem.
Thesafety,inletandoutletpipesmustbeprotectedfromicewherethismayoccur.
The safety pipe must allow the highest part of the generator to be in contact with the
atmosphere and not have reverse gradients, except for the section intended to lead into the
upper
partoftheexpansionvessel.
Theinletpipemustallowthelowestpartofthegeneratortobeincontactwiththelowestpart
of the expansion vessel and must not have reverse gradients capable of preventing circulation
bygravityinthecircuit(safetyandinletpipes,stove,expansionvessel).
The outlet pipe in contact with the outside must have a section at least equal to that of the
safetypipe.Theoverflowpipemayalsobeusedasanoutletpipeprovidedthatithas asection
notsmallerthanthatofthesafetypipe.
Ourgeneratormustnotbemountedinsideclosedexpansionvesselcircuits.
2.4Controlboardwiringdiagram
Forgeneralpurposes,thediagramofthecontrolboardinputandoutputconnections
isgiven.Thisdiagramisexpresslyintendedforthetechnicalpersonnelinchargeofinstallation
andmaintenance.
Formountingourproductparalleltoatraditionalgasboiler,accordingtothediagram
shownitisnecessarytoconnectathreewayvalveonthesamepins(15and16)usedforthe
recirculationpump.
M
Figure 2.9: Controlboardwiringdiagram
2.5Instructionsformountingproductcovering
Formountingtheoutercovering, simpleinstructions areprovided:
1. Useacrossheadscrewdriver.
2. Liftthetop(1),removethetwoscrewsholdingthedisplay.
Takecarewhenmovingthe topinordertoavoiddamaging or disconnecting theflat
connectingcablebetweentheboardandthe
display
3. Liftthesidepanelontherighthandside(2).
4. Repeatthesameprocessonthelefthandside.
5. Dismountthelowerpanel(3)removethescrewplacedonthebaseofthefrontdoor,
removethecarter.
Figure2.10:Pelletheaterinstructionsformountingproduct
5. Forsomemodelsitmightbenecessarytoliftandmovethesheetmetaltopofthe
heatersidewaysinordertoinsertthesidemajolicatiles.
3.0 MAINTENANCE
3.1 SCHEDULEDMAINTENANCE
It is necessary to perform periodic maintenance of the heater in order to ensure constantly
correctandeffectiveoperation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59