Textron F13 Portable Power Unit S/C GMZ User manual

Type
User manual

This manual is also suitable for

INSTRUCTION MANUAL
F13
Portable Power Unit
52056087 REV 2 © 2012 Greenlee Textron Inc. 3/12
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
Register this product at www.greenlee.com
Serial Code GMZ
Español ............... 13
Français .............. 25
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
2
Safety
Safety is essential in the use and maintenance of
Greenlee Utility tools and equipment. This manual and
any markings on the tool provide information for avoid-
ing hazards and unsafe practices related to the use of
this tool. Observe all of the safety information provided.
Purpose of this Manual
This manual is intended to familiarize all personnel with
the safe operation and maintenance procedures for the
following tool:
F13 Portable Power Unit
Serial Code GMZ
Keep this manual available to all personnel.
Replacement manuals are available upon request at no
charge at www.greenlee.com.
Other Publications
Tool Owners/Users
SAE Standard J1273 (Hose and Hose Assemblies):
Publication 99930323
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
Table of Contents
Description .................................................................... 2
Safety ............................................................................ 2
Purpose of this Manual ................................................. 2
Other Publications ......................................................... 2
Important Safety Information .....................................3–4
Identication .................................................................. 5
Specications ................................................................ 6
Hose Connections ......................................................... 6
Operation ....................................................................... 7
Maintenance ...............................................................8–9
Troubleshooting ........................................................9–11
Illustrations and Parts Lists ....................................36–40
Description
The F13 Portable Power Unit is a compact unit provid-
ing a variable ow of 20 to 30 l/min (5 to 8 gpm) and a
maximum pressure of 138 bar (2000 psi). It is a light-
weight power source intended for use with open-center
system hydraulic tools. HTMA couplers are provided for
tool connection.
Its compact size and light weight allow use at remote
work sites that might not be accessible by a larger
power unit or hydraulic truck. The ability to get close to
the work area allows the use of shorter hydraulic hoses,
increasing tool efciency.
The simple design of the hydraulic circuit and reli-
able Honda gasoline-powered engine ensure years of
trouble-free operation, when serviced according to the
recommended maintenance schedule. Other features
include a large capacity hydraulic oil cooler, sight level
gauge, large 330 mm (13") diameter no-at wheels, and
quick-release telescoping handles.
The Honda engine is equipped with a low oil alert and
shutdown protection system.
All specications are nominal and may change as design
improvements occur. Greenlee Textron Inc. shall not be liable for
damages resulting from misapplication or misuse of its products.
KEEP THIS MANUAL
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
3
IMPORTANT SAFETY INFORMATION
SAFETY
ALERT
SYMBOL
This symbol is used to call your attention to hazards
or unsafe practices which could result in an injury or
property damage. The signal word, dened below,
indicates the severity of the hazard. The message
after the signal word provides information for pre-
venting or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result
in severe injury or death.
Hazards which, if not avoided, COULD result in
severe injury or death.
Hazards or unsafe practices which, if not avoided,
MAY result in injury or property damage.
Read and understand all of the
instructions and safety information
in this manual before operating or
servicing this tool.
Failure to observe this warning will
result in severe injury or death.
Fuel is ammable and explosive.
Stop engine before lling fuel tank.
Do not ll fuel tank when engine
is hot.
Do not ll fuel tank near an open
ame, sparks, or when smoking.
Failure to observe this warning will
result in severe injury or death.
Do not run power unit engine in a
conned area.
Engine exhaust fumes are toxic.
If inhaled, exhaust fumes could
cause injury or death.
Skin injection hazard:
Do not use hands to check for
leaks.
Do not hold hose or couplers
while the hydraulic system is
pressurized.
Depressurize the hydraulic system
before servicing or disconnecting
hoses.
Oil under pressure easily punctures
skin, causing serious injury, gan-
grene, or death. If you are injured by
escaping oil, seek medical attention
immediately.
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from
ying debris or hydraulic oil.
Wear hearing protection when using
this tool.
Long-term exposure to high noise
levels could result in hearing loss.
Do not disconnect tool, hoses, or ttings while the
power source is running or if the hydraulic uid is
hot. Hot hydraulic uid could cause serious burns.
Failure to observe this warning could result in severe
injury.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
4
Do not operate power unit without
safety guards in place.
Keep all parts of the body and
loose clothing away from the
engine fan.
Failure to observe this warning
could result in severe injury or death.
Engine, exhaust system, and other
components will be hot during and
after operation. Use care when
working around the power unit. Hot
surfaces could cause serious burns.
Do not let power unit engine run unattended.
Monitor the engine so that it can be shut down
immediately in case of a malfunction.
Failure to observe this warning could result in severe
injury or death.
Use the lifting eye and appropriate lifting equipment.
Make sure all components used to lift this power
unit are rated for 91 kg (200 lb) and are securely
attached to the frame of the power unit. Inadequate
components may fail and cause the power unit to
fall, resulting in injury or property damage.
Inspect the hydraulic hoses and couplings every
operating day. Repair or replace if leakage, crack-
ing, wear, or damage is evident. Damaged hoses
or couplers may fail, resulting in injury or property
damage.
Use this power source for manufacturer’s intended
purpose only. Use other than that which is
described in this manual may result in injury or
property damage.
Make sure that all bystanders are clear of the work
area when handling, starting, and operating the
power unit. Nearby personnel may be injured by
ying parts in the event of a tool malfunction.
Hydraulic oil may cause skin irritation.
Handle the tool and hoses with care to prevent
skin contact with hydraulic oil.
In case of accidental skin contact with hydraulic
oil, wash the affected area immediately to remove
the oil.
Failure to observe these precautions may result in
injury.
Procedure for connecting or disconnecting hydraulic
hoses, ttings or components:
1. Rotate the ow control knob to the OFF
position.
2. Switch the engine OFF.
3. Follow the sequence under “Hose Connections”
to prevent pressure buildup. In case some
pressure has built up, loosen hoses, ttings, or
components slowly.
Emergency stop procedure: Switch the engine OFF.
Note: Keep all decals clean and legible, and replace
when necessary.
IMPORTANT SAFETY INFORMATION
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
5
Identification
31 2 64 5
7
8
10
11
12
1314
9
1. Recoil Starter
2. Engine ON/OFF Switch
3. Gasoline Engine, 13 hp
4. Hydraulic Pump
5. Hydraulic Oil Cooler
6. Engine Oil Fill Cap and Level Gauge
7. Tool Connection—Return
8. Tool Connection—Pressure
9. Flow ON/OFF Control
10. Handle
11. Handle Release Knob
12. Hydraulic Reservoir, Fill Cap, and Filter
13. Lifting Bracket
14. Fuel Tank
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
6
Specifications
Portable Power Unit
Oil Flow
At 2500 rpm ....................................... 20 l/min (5 gpm)
At 3600 rpm ....................................... 30 l/min (8 gpm)
Working Pressure (nominal) ................. 138 bar (2000 psi)
Pressure Relief Valve .................Set at 150 bar (2175 psi)
Pump .............................................................. Gear pump
Maximum Oil Temperature .........................70 °C (160 °F)
Hydraulic Oil Tank Capacity
Minimum ...................................................... 6 l (6.3 qt)
Maximum ..................................................... 8 l (8.5 qt)
Gasoline Tank Capacity ................................ 6.5 l (1.8 gal)
Hydraulic System Compl. ................................9 l (2.4 gal)
Filter System (lter element) ........25 micron with by-pass
Engine ............................................... Honda GX390QXB7
13 hp 4-stroke gasoline
with oil alert system
Gasoline .......................................Regular or unleaded
Engine Oil .................................................. 1.1 l (1.2 qt)
Guaranteed Sound Power Level L
WA
....................101 dB
Sound Pressure Level 1 m L
PA
................................89 dB
Dimensions (LxWxH) ....................... 710 x 595 x 650 mm
(28" x 23.5" x 25.5")
Weight
Without Hydraulic Oil and Fuel .............. 76 kg (168 lb)
With All Fluids ........................................ 90 kg (198 lb)
Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic
uid which meets the following specications or HTMA
specications.
S.U.S. @
38 °C (100 °F) ..............................................140 to 225
99 °C (210 °F) ........................................... 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Pour Point ................................. –34 °C (–30 °F) minimum
Hose Connections
Do not disconnect tool, hoses, or ttings while the
power source is running or if the hydraulic uid is
hot. Hot hydraulic uid could cause serious burns.
Failure to observe this warning could result in severe
injury.
Connecting Hoses
1. Stop the power unit hydraulic ow.
2. Connect the return (tank) hose from the power unit
port to the tool return port (T).
Note: Return (tank) hose connection should always
be connected before pressure (supply) hose con-
nection to prevent pressure buildup inside the tool.
3. Connect the pressure (supply) hose from the power
unit pressure port to the tool pressure port (P).
Disconnecting Hoses
1. Stop the power unit hydraulic ow.
2.
Disconnect the pressure (supply) hose from the
power unit pressure port to the tool pressure port
(P).
Note: Pressure (supply) hose connection should
always be disconnected before return (tank)
hose connection to prevent pressure buildup inside
the tool.
3. Disconnect the return (tank) hose from the power
unit return port to the tool return port (T).
4. To prevent contamination, always install dust caps
over the hydraulic ports of the tool, hoses, and
power unit when disconnected.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Starting Instructions
Please observe the starting instructions on the front of
the power unit.
Start
1. Check the engine oil level.
2. Check the fuel level.
3. Check the hydraulic oil level at the sight glass.
4. Connect the hoses and tool.
5. Switch the fuel valve to ON.
6. To start a cold engine, activate the choke.
To start a warm engine, leave the choke knob in the
OPEN position.
7. Turn the engine switch to the ON position.
8. Pull the recoil starter. If the choke lever is in the
choke position to start the engine, gradually push it
to the OPEN position as the engine warms up.
9. Rotate the ow control lever to the desired ow rate.
Stop
1. Move the lever to OFF.
2. Turn off the ignition switch.
3. Turn the fuel valve to OFF.
Adjustable Hydraulic Oil Flow
The desired oil ow can be set on the front of the power
unit. A marking is engraved in the lever.
Turn the lever to the right until the marking is opposite
the required ow.
The pressure relief valve setting will be the same on all
ows.
Lifting the Power Unit
Use the lifting eye and appropriate lifting equipment.
Make sure all components used to lift this power
unit are rated for 91 kg (200 lb) and are securely
attached to the frame of the power unit. Inadequate
components may fail and cause the power unit to
fall, resulting in injury or property damage.
Stop the power unit engine before lifting. Take care
when attaching the lifting device (chain, strap, etc.) to
the lifting eye so as not to damage the power unit.
Operation
Choke Knob
Engine ON/OFF Switch
Fuel ON/OFF Switch
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
Maintenance
Filling up with Hydraulic Oil
1. Loosen the lter cover on top of the power unit.
2. Remove the lter element (see photo), and ll up
with oil. When oil is showing at the bottom of the
lter unit, there is enough oil in the power unit.
3. Insert the lter element again, mount the cover, and
the power unit is ready for use.
Note: When connecting new extension hoses, it is
necessary to fill up with extra 2 l (2.1 qt) of oil. Therefore,
always top up the power unit when connecting new
extension hoses.
Depressurizing Hydraulic System
Skin injection hazard:
Do not use hands to check for
leaks.
Do not hold hose or couplers
while the hydraulic system is
pressurized.
Depressurize the hydraulic system
before servicing or disconnecting
hoses.
Oil under pressure easily punctures
skin, causing serious injury, gan-
grene, or death. If you are injured by
escaping oil, seek medical attention
immediately.
Hydraulic system must be depressurized when perform-
ing maintenance or repair on the power unit hydraulic
system. Depressurizing the hydraulic system also makes
tool hose connections/disconnections easier.
1. Stop the power unit engine.
2. Move the ow ON/OFF lever to the ON position.
The system will be depressurized.
3. Before restarting the power unit engine, move the
ow ON/OFF lever to the OFF position.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
9
Maintenance (cont’d)
MAINTENANCE SCHEDULE
The service life of the power unit will be maximized
by proper care and maintenance. The maintenance
schedule below is recommended.
Note: Change engine oil after the first 5 hours of opera-
tion. Thereafter, change engine oil according to
the maintenance schedule below.
Every 5 Hours
1. Check engine crankcase oil level. Fill if necessary.
Refer to the Engine Owner’s Manual.
2. Check fuel tank level. Fill if necessary.
Refer to the Engine Owner’s Manual.
3. Check hydraulic reservoir oil level. Fill to FULL mark
on sight gauge. Do not overll reservoir. Refer to the
“Recommended Hydraulic Fluids” section.
Every 10 Hours
1. Wipe all power unit surfaces clean of grease,
dirt, and foreign material.
2. Inspect the hydraulic system hoses and ttings
for signs of leaks, cracks, wear, or damage.
Replace if necessary.
Every 25 Hours
Service engine air cleaner/pre-cleaner. Refer to the
Engine Owner’s Manual.
Every 50 Hours
Change engine crankcase oil and oil lter. Refer to the
Engine Owner’s Manual.
Every 100 Hours or Once Yearly
1. Drain hydraulic reservoir oil. Clean and ush res-
ervoir. Change hydraulic oil lter. Fill reservoir with
new, clean hydraulic oil. Refer to “Recommended
Hydraulic Fluids” section. Operate power unit to
circulate oil through the hydraulic system. Stop
power unit. Recheck hydraulic oil level. Fill reservoir
to the FULL mark on the sight gauge. Do not overll
reservoir.
2. Service engine air cleaner cartridge. Refer to the
Engine Owner’s Manual.
3. Perform a detailed inspection of the system
hoses and ttings as stated in 99930323—
SAE Standard J1273. Replace the hoses and/or
ttings if necessary.
Troubleshooting
Before You Begin
1. Any tool used with this power unit must be an
open-center system type tool.
2. Verify that the pressure and return hoses are con-
nected properly to the power unit and tool ports.
3. Power unit reservoir must be lled to the FULL mark
with hydraulic uid.
4. Start the power unit hydraulic oil ow. All separate
shut-off devices must be opened (ON/OFF valves,
etc.)
5. After verifying all of the above, check the tool to see
if it operates.
If the tool does not operate, it will be necessary
to pinpoint the power unit, tool, or hoses and the
problem area. The following steps will help to deter-
mine the problem area.
Determine the Problem Area
1. Stop the power unit hydraulic oil ow. Disconnect
the existing tool from the hoses and power unit.
2. Connect a known working tool to the hoses and
power unit. Refer to the tool’s operator’s manual
for correct hookup procedure. Start the power unit
hydraulic oil ow.
If the known working tool operates, the problem
is in the disconnected tool. Refer to the tool
operator’s manual for troubleshooting.
If the known working tool does not operate, the
problem is likely to be in the hoses or the power
unit. Proceed to Step 3.
3. Stop the power unit hydraulic oil ow. Disconnect
the existing hoses from the known working tool and
power unit.
4. Connect a different set of hoses to the known
working tool and power unit. Start the power unit
hydraulic oil ow.
If the known working tool operates with the
different set of hoses, the problem is in the
disconnected hoses.
If the known working tool does not operate,
the problem is in the power unit. Refer to the
trouble shooting charts in this manual.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
10
Troubleshooting (cont’d)
Problem Probable Cause Probable Remedy
Engine does not start. No fuel in tank. Fill fuel tank.
Low engine oil level. Check engine oil level.
Fill to FULL mark.
Flow ON/OFF handle in the ON
position.
Move handle to the OFF position.
Electrical short, broken wire, or
looseconnection.
Check wires and connections.
Repair or replace.
Refer to the Engine Owner’s Manual.
Engine lacks power, runs rough,
backres, etc.
Refer to the Engine Owner’s Manual.
Tool used with power unit is
inoperative.
Flow ON/OFF valve in the OFF
position.
Move ow ON/OFF valve to ON
position.
Tool is a closed-center system type. Use only open-center system tools.
No hydraulic uid in system or uid
level low.
Check uid level. Fill to FULL mark.
Check system for leaks.
Incorrect hydraulic uid viscosity. Use uid viscosity recommended.
Refer to “Recommended Hydraulic
Fluids.”
Hydraulic lter needs service. Replace hydraulic lter.
Power unit components (pump,
valve, etc.) worn or damaged.
Repair or replace components.
Engine output insufcient. Engine
needs adjustment, tune-up, etc.
Refer to the Engine Owner’s Manual.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
11
Troubleshooting (cont’d)
Problem Probable Cause Probable Remedy
Tool used with power unit operates
erratically.
Hydraulic uid cold. Viscosity of oil may be too high
at start of tool operation. Allow oil
to warm to operating temperature
Actuating tool intermittently will
reduce time required to warm oil to
an efcient operating temperature.
Hydraulic uid level low. Check uid level. Fill to FULL mark.
Check system for leaks.
Incorrect hydraulic uid viscosity. Use uid viscosity recommended.
Refer to “Recommended Hydraulic
Fluids.”
Air in system. Check pump suction line for damage
or loose clamps. Tighten clamps or
replace components if necessary. Fill
reservoir.
Hydraulic oil ow (gpm) incorrect
fortool being used.
Adjust engine rpm to achieve correct
ow (gpm) for tool being used.
Hydraulic lter needs service. Replace hydraulic lter.
Power unit components (pump,
valve, etc.) worn or damaged.
Repair or replace components.
Engine output insufcient. Engine
needs adjustment, tune-up, etc.
Refer to the Engine Owner’s Manual.
Tool used with power unit feels hot. Hydraulic uid level low. Check uid level. Fill to FULL mark.
Check system for leaks.
Hydraulic uid viscosity too light. Use uid viscosity recommended.
Refer to “Recommended Hydraulic
Fluids.”
Hydraulic uid dirty. Drain reservoir, ush, and ll with
clean uid. Change lter.
Hydraulic oil ow (gpm) incorrect
fortool being used.
Adjust engine rpm to achieve correct
ow (gpm) for tool being used.
Tool used with power unit operates
backward.
Hydraulic ow to tool reversed. Reverse ow to tool. Check for valve
in system that has reversed ow.
Check hoses for proper ow.
Hydraulic pressure and return lines
connected to incorrect power unit
ortool ports.
Disconnect hoses. Reverse couplers.
Reconnect hoses to proper power
unit and tool ports.
F13 Portable Power Unit
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
12
MANUAL DE INSTRUCCIONES
Unidad de Potencia
Portátil F13
Lea y entienda todas las instucciones y la infor-
mación sobre seguridad que aparecen en este
manual, antes de manejar estas herramientas o
darles mantenimiento.
Registre este producto en www.greenlee.com
Código de serie GMZ
52056087 REV 2 © 2012 Greenlee Textron Inc. 3/12
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
14
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar
y dar mantenimiento a las herramientas y equipo
Greenlee Utility. Este manual y todas las marcas
que ostenta la herramienta le ofrecen la información
necesaria para evitar riesgos y hábitos poco seguros
relacionados con su uso. Siga toda la información sobre
seguridad que se proporciona.
Propósito de este manual
Este manual tiene como propósito familiarizar a todo
el personal con los procedimientos de operación y
mantenimiento seguros para la herramienta siguiente:
Unidad de Potencia Portátil F13
Código de serie GMZ
Manténgalo siempre al alcance de todo el personal.
Puede obtener copias adicionales de manera gratuita,
previa solicitud en www.greenlee.com.
Otras Publicaciones
Para propietarios o usuarios de la herramienta
Norma SAE J1273 (Manguera y conjuntos de mangueras):
Publicación 99930323
¡No deseche ni descarte este producto!
Para información sobre reciclaje,
visite www.greenlee.com.
Índice
Descripción ................................................................. 14
Acerca de la seguridad ................................................ 14
Propósito de este manual ........................................... 14
Otras Publicaciones .................................................... 14
Importante información sobre seguridad ............... 15-16
Identicación ............................................................... 17
Especicaciones ......................................................... 18
Conexión de las mangueras ........................................ 18
Operación .................................................................... 19
Mantenimiento ........................................................ 20-21
Diagnóstico y Solución de Fallas ........................... 21-23
Ilustraciones y Lista de Piezas ............................... 36-40
Descripción
La Unidad de Potencia Portátil F13 es una unidad
compacta que suministra un ujo variable de 20 a 30l/
min (5 a 8 gpm) y una presión máxima de 138 bar (2000
psi). Es una fuente de potencia liviana diseñada para
usarse con herramientas hidráulicas con sistemas de
circuito abierto. Se incluyen acopladores HTMA para
llevar a cabo la conexión de la herramienta.
Su tamaño compacto y su peso liviano permiten su uso
en ubicaciones de trabajo remotas donde no pueden
llegar las unidades de potencia de mayor tamaño o los
camiones hidráulicos. Su capacidad de poder acercarse
al área de trabajo permite el uso de mangueras
hidráulicas más cortas, aumentando de esa manera la
ecacia de la herramienta.
El sencillo diseño del circuito hidráulico y el motor
Honda, accionado mediante gasolina y de gran
conabilidad, aseguran años de funcionamiento sin
problemas, cuando se le hace el servicio de acuerdo al
programa de mantenimiento recomendado. Entre otras
características se incluyen un enfriador de aceite para
aparatos hidráulicos de gran capacidad, indicador de
nivel con mirilla, ruedas de diámetro grande de 330 mm
(13 pulg.) que no se desinan, y asas telescópicas de
liberación rápida.
El motor Honda está equipado con una alerta de nivel
bajo de aceite y un sistema de protección y apagado.
Todas las especicaciones son nominales y pueden cambiar cuando
se realicen mejoras en el diseño. Greenlee Textron Inc. no será
responsable por daños que resulten de la aplicación o uso indebidos
de sus productos.
CONSERVE ESTE MANUAL
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
15
IMPORTANTE INFORMACIÓN SOBRE SEGURIDAD
SÍMBOLO DE
ALERTA SOBRE
SEGURIDAD
Este símbolo se utiliza para indicar un riesgo o práctica
poco segura que podría ocasionar lesiones o daños
materiales. Cada uno de los siguientes términos denota
la gravedad del riesgo. El mensaje que sigue a dichos
términos le indica cómo puede evitar o prevenir dicho
riesgo.
Peligros inmediatos que, de no evitarse,
OCASIONARÁN graves lesiones o incluso la muerte.
Peligros que, de no evitarse, PODRÍAN
OCASIONAR graves lesiones o incluso la muerte.
Peligro o prácticas peligrosas que, de no evitarse,
PUEDEN OCASIONAR lesiones o daños materiales.
Lea y entienda todas las instrucciones
y la información sobre seguridad
que aparecen en este manual, antes
de manejar esta herramienta o darle
mantenimiento.
De no observarse esta advertencia
pueden sufrirse graves lesiones o
incluso la muerte.
El combustible es inamable y
explosivo.
Apague el motor antes de llenar el
tanque de combustible.
No llene el tanque de combustible si
el motor está caliente.
No llene el tanque de combustible
cerca de llamas abiertas, chispas o
si está fumando.
De no observarse esta advertencia
pueden sufrirse graves lesiones o
incluso la muerte.
No haga funcionar el motor de
la unidad de potencia en un área
connada.
El motor emite emanaciones tóxicas.
La inhalación de estas emanaciones
podría provocar lesiones o la muerte.
Peligro de inyección cutánea:
No use las manos para localizar
fugas.
No toque la manguera ni los
acopladores mientras el sistema
hidráulico se encuentre presurizado.
Purgue la presión del sistema
hidráulico antes de darle manteni-
miento o desconectar las
mangueras.
El aceite bajo presión punza la
piel fácilmente provocando graves
lesiones, gangrena o la muerte. Si se
lesiona debido a una fuga de aceite,
solicite atención médica de inmediato.
Utilice protectores para ojos al
manejar o darle mantenimiento a esta
herramienta.
De no utilizar protectores para ojos
podría sufrir graves lesiones oculares
ocasionadas si el aceite para aparatos
hidráulicos, o restos de materiales
llegaran a saltar.
Al manejar esta herramienta utilice
protectores para oídos.
La exposición continua a altos niveles
de ruido podría resultar en pérdida de
la audición.
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
16
No desconecte la herramienta, ni las mangueras
o accesorios mientras la fuente de energía esté
encendida o el uido para aparatos hidráulicos esté
caliente. El uido para aparatos hidráulicos caliente
podría ocasionar quemaduras graves.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
No haga funcionar la unidad
de potencia si las protecciones
de seguridad no se encuentran
colocadas en su posición.
Mantenga todas las partes del
cuerpo y la vestimenta holgada
alejadas del ventilador del motor.
De no observarse esta advertencia
podrían sufrirse graves lesiones o
incluso la muerte.
El motor, el sistema de escape y
otros componentes pueden alcanzar
temperaturas sumamente altas
mientras están en operación o incluso
una vez que han sido apagados.
Sea precavido al trabajar alrededor
de la unidad de potencia. Las
supercies calientes podrían provocar
quemaduras graves.
No deje la herramienta desatendida mientras está
funcionando. Monitorice el motor de modo que pueda
apagarse de manera inmediata en la eventualidad de
un mal funcionamiento.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Utilice la argolla de izar y el equipo de izado adecuado.
Asegúrese que la capacidad nominal de todos los
componentes utilizados para izar la unidad de potencia
sea 91 kg (200 lb) y que estén rmemente sujetados
en el bastidor de la unidad de potencia. El uso de
componentes inadecuados podría provocar un fallo y
producir la caída de la unidad de potencia, y ocasionar
lesiones o daño a la propiedad.
Revise minuciosamente las mangueras hidráulicas
y los acoplamientos cada vez que vaya a utilizar la
herramienta. Repárelos o reemplácelos si presentan
fugas, grietas, desgaste o daños evidentes. Las
mangueras y acopladores averiados pueden fallar y
ocasionar lesiones o daños materiales.
Utilice esta fuente de potencia únicamente para
el propósito para el que ha sido diseñada por el
fabricante. Utilizarla de manera distinta a la descrita
en este manual podría ocasionar graves lesiones o
daños materiales.
Asegúrese que no haya otras personas en el área
de trabajo al manipular la unidad de potencia,
ponerla en funcionamiento o manejarla. El personal
del área podría sufrir lesiones si alguna pieza saliera
disparada al haber un desperfecto de la herramienta.
El aceite para aparatos hidráulicos podría causar
irritación dérmica.
Maneje la herramienta y las mangueras con cuidado
para evitar que el aceite para aparatos hidráulicos
entre en contacto con la piel.
En caso de un contacto accidental, lávese de
inmediato el área afectada a n de eliminar el aceite.
De no observarse estas advertencias podrían sufrirse
lesiones.
Procedimiento para conectar o desconectar las
mangueras, accesorios o demás componentes
hidráulicos:
1. Gire la perilla de control de ujo a la posición OFF
(CERRADO).
2. APAGUE el motor.
3. Siga la secuencia detallada en “Conexión de
las mangueras” a n de evitar una acumulación
de presión. En caso de que esto ocurra, aoje
lentamente las mangueras, los accesorios o los
componentes.
Procedimiento de apagado de emergencia: APAGUE el
motor.
Nota: Mantenga limpias y legibles todas las calcomanías
y reemplácelas cuando sea necesario.
IMPORTANTE INFORMACIÓN SOBRE SEGURIDAD
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
17
Identificación
31 2 64 5
7
8
10
11
12
1314
9
1. Cuerda de arranque con rebobinado
2. Interruptor ON/OFF (ENCENDIDO/APAGADO) del motor
3. Motor accionado mediante gasolina, 13 hp
4. Bomba hidráulica
5. Enfriador de aceite para aparatos hidráulicos
6. Tapón de llenado de aceite de motor e indicador de nivel
7. Conexión de la herramienta—Retorno
8. Conexión de la herramienta—Presión
9. Control de ujo ON/OFF (ABIERTO/CERRADO)
10. Asa
11. Perilla de liberación de asa
12. Depósito de aceite para aparatos hidráulicos, tapón de
llenado, y ltro
13. Abrazadera de izar
14. Tanque de combustible
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
18
Especificaciones
Unidad de Potencia Portátil
Flujo de aceite
A 2500 rpm ........................................ 20 l/min (5 gpm)
A 3600 rpm ........................................ 30 l/min (8 gpm)
Presión de funcionamiento
(nominal) .................................... 138 bar (2000 lb./pulg.
2
)
Válvula de alivio de presión .......................Establecida en
150 bar (2175 lb./pulg.
2
)
Bomba ........................................... Bomba de engranajes
Temperatura máxima de aceite ..................70 °C (160 °F)
Capacidad del tanque de aceite
para aparatos hidráulicos
Mínimo ..................................6 l (6,3 cuartos de galón)
Máximo .................................8 l (8,5 cuartos de galón)
Capacidad del tanque de gasolina ...........6,5 l (1,8 galón)
Compl. del sistema hidráulico .....................9 l (2,4 galón)
Sistema de ltro (elemento del ltro) ......... 25 micras con
derivación
Motor ...................................... Honda GX390QXB7 13 hp
de 4 tiempos a gasolina
con sistema de alerta de aceite
Gasolina .......................................Regular o sin plomo
Aceite de motor ..................1,1 l (1,2 cuartos de galón)
Nivel de potencia acústica garantizado L
WA
.........101 dB
Nivel de presión acústica a 1 m L
PA
........................89 dB
Dimensiones (LxAxAlt.) .................... 710 x 595 x 650 mm
(28 x 23,5 x 25,5 pulg.)
Peso
Sin aceite para aparatos
hidráulicos ni combustible ..................... 76 kg (168 lb)
Con todos los uidos ............................. 90 kg (198 lb)
Fluidos recomendados para aparatos hidráulicos
Puede emplearse cualquier uido para aparatos
hidráulicos, sin detergente, con base de petróleo y que
cumpla con las siguientes especicaciones de la HTMA.
S.U.S a:
38°C (100°F ) ................................................ 140 a 225
99°C (210°F) ................................................ 40 mínimo
Punto de inamación .....................170°C (340°F) mínimo
Punto de temperatura
de descongelación ......................... -34°C (-30°F) mínimo
Conexión de las mangueras
No desconecte la herramienta, ni las mangueras
o accesorios mientras la fuente de energía esté
encendida o el uido para aparatos hidráulicos esté
caliente. El uido para aparatos hidráulicos caliente
podría ocasionar quemaduras graves.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Conexión de las mangueras
1. Detenga el ujo hidráulico de la unidad de potencia.
2. Conecte la manguera de retorno (tanque) del oricio
de la unidad de potencia al oricio de retorno de la
herramienta (T).
Nota: La conexión de la manguera de retorno
(tanque) se debe hacer siempre antes de la con-
exión de la manguera de presión (suministro)
para evitar que se acumule presión dentro de la
herramienta.
3. Conecte la manguera de presión (suministro) del
oricio de presión de la unidad de potencia al
oricio de presión de la herramienta (P).
Desconexión de las mangueras
1. Detenga el ujo hidráulico de la unidad de potencia.
2. Desconecte la manguera de presión (suministro)
del oricio de presión de la unidad de potencia del
oricio de presión de la herramienta (P).
Nota: La conexión de la manguera de presión (sum-
inistro) se debe hacer siempre antes de desconectar
la manguera de retorno (tanque) para evitar que se
acumule presión dentro de la herramienta.
3. Desconecte la manguera de retorno (tanque) del
oricio de retorno de la unidad de potencia del
oricio de retorno de la herramienta (T).
4. Para evitar la contaminación, coloque siempre
tapas guardapolvo en los oricios hidráulicos de la
herramienta, mangueras y la unidad de potencia.
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
19
Instrucciones para el arranque
Cumpla las instrucciones para el arranque impresas en
el frente de la unidad de potencia.
Arranque
1. Revise el nivel de aceite del motor.
2. Revise el nivel de combustible.
3. Revise el nivel del aceite para aparatos hidráulicos a
través de la mirilla.
4. Conecte las mangueras y la herramienta.
5. Coloque la válvula de combustible en la posición
ON (ENCENDIDO).
6. Para arrancar un motor en frío, active el
estrangulador. Para arrancar un motor en caliente,
mantenga la perilla de estrangulación en la posición
OPEN (ABIERTO).
7. Lleve el interruptor del motor a la posición ON
(ENCENDIDO).
8. Tire de la cuerda de arranque con rebobinado.
Si la perilla de estrangulación está en la posición
de estrangulación para arrancar el motor, llévela
lentamente a la posición OPEN (ABIERTO) a medida
que el motor vaya calentando.
9. Gire la palanca de control de ujo hasta lograr el
caudal deseado.
Para apagar
1. Mueva la palanca a la posición OFF (APAGADO).
2. Apague el interruptor de encendido.
3. Coloque la válvula de combustible en la posición
OFF (APAGADO).
Flujo ajustable de aceite para aparatos hidráulicos
El ujo deseado de aceite se puede ajustar en el frente
de la unidad de potencia. La palanca tiene una marca
grabada.
Gire la palanca hacia la derecha hasta que la marca
quede frente al ujo requerido.
El ajuste de la válvula de alivio de presión será el mismo
para todos los caudales.
Izaje de la unidad de potencia
Utilice la argolla de izar y el equipo de izado adecuado.
Asegúrese que la capacidad nominal de todos los
componentes utilizados para izar la unidad de potencia
sea 91 kg (200 lb) y que estén rmemente sujetados
en el bastidor de la unidad de potencia. El uso de
componentes inadecuados podría provocar un fallo y
producir la caída de la unidad de potencia, y ocasionar
lesiones o daño a la propiedad.
Detenga el motor de la unidad de potencia antes de
izar. Sea precavido al acoplar el dispositivo de izado
(cadena, correa, etc.) a la argolla de izado para evitar
ocasionar daños a la unidad de potencia.
Operación
Perilla de
estrangulamiento
Interruptor ON/OFF
(ENCENDIDO/APAGADO)
del motor
Interruptor ON/OFF (ENCENDIDO/APAGADO)
del combustible
Unidad de Potencia Portátil F13
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
20
Mantenimiento
Llenado con aceite para aparatos hidráulicos
1. Aoje la tapa del ltro en la parte superior de la
unidad de potencia.
2. Retire el elemento de ltro (vea la fotografía), y llene
el depósito de aceite. Cuando el aceite alcanza el
nivel inferior de la unidad de ltro, ya hay suciente
aceite en la unidad de potencia.
3. Vuelva a introducir el elemento de ltro, coloque la
tapa, y la unidad de potencia ya está lista para el
uso.
Aviso: Al conectar mangueras de extensión nuevas, es
necesario agregar 2 l (2,1 cuartos de galón) de aceite
adicionales. Por lo tanto, al conectar mangueras nuevas
de extensión rellene de aceite hasta el nivel máximo.
PROGRAMA DE MANTENIMIENTO
El cuidado y mantenimiento adecuados prolongarán la
vida útil de la unidad de potencia. Se recomienda seguir
el programa de mantenimiento abajo indicado.
Nota: Cambie el aceite del motor después de las
primeras 5 horas de funcionamiento. Luego, cambie el
aceite del motor según el programa de mantenimiento
abajo indicado.
Cada 5 horas
1. Revise el nivel de aceite en el cárter del motor.
Llene según sea necesario. Consulte el Manual del
Propietario del Motor.
2. Revise el nivel en el tanque de combustible. Llene
según sea necesario. Consulte el Manual del
Propietario del Motor.
3. Revise el nivel del aceite en el depósito hidráulico.
Llene hasta la marca FULL (LLENO) en el indicador
visual. No llene el depósito demasiado. Consulte
la sección “Fluidos recomendados para aparatos
hidráulicos”.
Despresurización del sistema hidráulico
Peligro de inyección cutánea:
No use las manos para localizar
fugas.
No toque la manguera ni los
acopladores mientras el sistema
hidráulico se encuentre presurizado.
Purgue la presión del sistema
hidráulico antes de darle manteni-
miento o desconectar las
mangueras.
El aceite bajo presión punza la
piel fácilmente provocando graves
lesiones, gangrena o la muerte. Si se
lesiona debido a una fuga de aceite,
solicite atención médica de inmediato.
Debe purgarse la presión del sistema hidráulico al
realizarse tareas de mantenimiento o reparación en el
sistema hidráulico de la unidad de potencia. Al purgar
la presión del sistema hidráulico se facilita además la
conexión y desconexión de las mangueras.
1. Detenga el motor de la unidad de potencia.
2. Mueva la palanca de ujo ON/OFF (ABIERTO/
CERRADO) a la posición ON (ABIERTO). Se purgará
la presión del sistema.
3. Antes de volver a hacer funcionar el motor de la
unidad de potencia, mueva la palanca de ujo
ON/OFF (ABIERTO/CERRADO) a la posición
OFF (CERRADO).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Textron F13 Portable Power Unit S/C GMZ User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI