Comnet CNGE8FX4TX4MS User manual

Category
Network switches
Type
User manual
INSTALLATION AND OPERATION MANUAL
CNGE8FX4TX4MS
ENVIRONMENTALLY HARDENED MANAGED
ETHERNET SWITCH WITH (4) 10/100/1000TX
+ (4) 100/1000FX SFP PORTS
V1.10 – July 2010
The ComNet™ CNGE8FX4TX4MS Managed Ethernet Switch provides
transmission of (4) 100/1000 BASE-TX and (4) 10/100/1000FX combo ports.
Unlike most Ethernet switches, these environmentally hardened units are
designed for deployment in difficult operating environments, and are available
for use with either conventional CAT-5e copper or optical transmission media.
Ports 1 4 support the 10/100/1000 Mbps Ethernet IEEE 802.3 protocol, and
auto-negotiating and auto-MDI/MDIX features are provided for simplicity and
ease of installation. Ports 5 8 are 10/100/1000 configurable for copper or
100/1000 fiber media for use with multimode or single mode optical fiber
without need for configuration, selected by optional SFP modules. These
network managed layer 2 switches are optically and electrically compatible
with any IEEE 802.3 compliant Ethernet devices. Plug-and-play design
ensures ease of installation, and no electrical or optical adjustments are ever
required. The CNGE8FX4TX4MS incorporates LED indicators for monitoring the
operating status of the managed switch and network.
2
Content
Overview ............................................................................................................................... 1!
Introduction...................................................................................................................................1!
ComNet CNGE8FX4TX4MS Features...........................................................................................4!
CNGE8FX4TX4MS Technical Specifications ................................................................................6!
Packing List ..................................................................................................................................8!
Safety Precaution..........................................................................................................................8!
Hardware Description.......................................................................................................... 9!
Front Panel....................................................................................................................................9!
Top View .....................................................................................................................................10!
Wiring the Power Inputs..............................................................................................................10!
LED Indicators ............................................................................................................................12!
Ports............................................................................................................................................13!
Cabling........................................................................................................................................14!
DIN-Rail Mounting Installation.......................................................................................... 17!
Wall Mount Plate Mounting............................................................................................... 19!
Hardware Installation ........................................................................................................ 20!
Installation Steps ........................................................................................................................20!
X-Ring Application ......................................................................................................................21!
Coupling Ring Application ..........................................................................................................22!
Dual Homing Application ............................................................................................................23!
Console Management ....................................................................................................... 24!
Connecting to the Console Port .................................................................................................24!
Pin Assignment ...........................................................................................................................25!
Login through the Console Interface ..........................................................................................26!
CLI Management ........................................................................................................................28!
System Commands Set.......................................................................................................................... 30!
Port Commands Set............................................................................................................................... 32!
Trunk Commands Set ............................................................................................................................ 34!
DMI Commands Set ............................................................................................................................... 36!
VLAN Commands Set ............................................................................................................................ 36!
Spanning Tree Commands Set .............................................................................................................. 38!
QOS Commands Set.............................................................................................................................. 40!
IGMP Commands Set ............................................................................................................................ 41!
Mac / Filter Table Commands Set.......................................................................................................... 41!
SNMP Commands Set ........................................................................................................................... 42!
Port Mirroring Commands Set ............................................................................................................... 45!
802.1x Commands Set........................................................................................................................... 45!
TFTP Commands Set ............................................................................................................................. 47!
SystemLog, SMTP and Event Commands Set ...................................................................................... 48!
SNTP Commands Set ............................................................................................................................ 50!
X-ring Commands Set ............................................................................................................................ 51!
Web-Based Management.................................................................................................. 52!
About Web-based Management.................................................................................................52!
Preparing for Web Management.................................................................................................52!
System Login ..............................................................................................................................53!
Main interface .............................................................................................................................54!
System Information.....................................................................................................................55!
DHCP Server – System configuration.........................................................................................57!
DHCP Client – System Configuration .........................................................................................58!
DHCP Server - Port and IP Bindings ..........................................................................................58!
4
TFTP – Firmware Update ............................................................................................................59!
TFTP – Restore Configuration.....................................................................................................59!
TFTP - Backup Configuration .....................................................................................................60!
System Event Log – Syslog Configuration .................................................................................61!
System Event Log - SMTP Configuration ...................................................................................62!
System Event Log - Event Configuration....................................................................................63!
Fault Relay Alarm ........................................................................................................................64!
SNTP Configuration ....................................................................................................................65!
IP Security...................................................................................................................................68!
User Authentication ....................................................................................................................69!
Port Statistics..............................................................................................................................70!
Port Control.................................................................................................................................71!
Port Trunk ...................................................................................................................................72!
Aggregator setting.................................................................................................................................. 72!
Aggregator Information .......................................................................................................................... 73!
State Activity .......................................................................................................................................... 74!
Port Mirroring ..............................................................................................................................75!
Rate Limiting ...............................................................................................................................76!
DMI (Digital Monitoring Interface) ...............................................................................................77!
VLAN configuration .....................................................................................................................78!
VLAN configuration - Port-based VLAN ................................................................................................. 79!
802.1Q VLAN.......................................................................................................................................... 81!
Rapid Spanning Tree ..................................................................................................................84!
RSTP - System Configuration ................................................................................................................ 84!
RSTP - Port Configuration...................................................................................................................... 85!
SNMP Configuration ...................................................................................................................87!
System Configuration ............................................................................................................................. 87!
Trap Configuration.................................................................................................................................. 88!
SNMPV3 Configuration .......................................................................................................................... 89!
QoS Configuration ......................................................................................................................92!
QoS Policy and Priority Type ................................................................................................................. 92!
Port Base Priority ................................................................................................................................... 94!
COS Configuration ................................................................................................................................. 94!
TOS Configuration.................................................................................................................................. 94!
IGMP Configuration ....................................................................................................................95!
X-Ring .........................................................................................................................................97!
LLDP Configuration.....................................................................................................................99!
Security .....................................................................................................................................100!
802.1X/Radius Configuration ............................................................................................................... 100!
MAC Address Table ............................................................................................................................. 103!
Factory Default..........................................................................................................................107!
Save Configuration ...................................................................................................................107!
System Reboot .........................................................................................................................107!
Help ................................................................................................................................... 108!
LED Diagnostic Indicators .............................................................................................. 108!
1
Overview
Introduction
To create reliability in your network, the ComNet CNGE8FX4TX4MS 4 10/100/1000T + 4 SFP
Managed Switch comes equipped with a proprietary redundant network protocol—X-Ring
provides users with an easy way to establish a redundant Ethernet network with ultra
high-speed recovery time less than 20ms. Also, the long MTBF (Mean Time Between Failures)
ensures that the switch will continue to operate until a Gigabit network infrastructure has
been established, without requiring any extra upgrade costs.
Aside from 4 x 10/100/1000Base-T fast Ethernet ports, the CNGE8FX4TX4MS comes
equipped with 4 SFP (mini-GBIC) ports. Traditional RJ45 ports can be used for uplinking
wide-band paths in short distance (< 100 m), while the SFP slots can be used for the
application of wideband uploading and long distance transmissions to fit the field request
flexibility. Also, the long MTBF (Mean Time Between Failures) ensures that the
CNGE8FX4TX4MS will continue to operate until a Gigabit network infrastructure has been
established, without requiring any extra upgrade costs.
SFP Advantages
The SFP fiber slots provide a lot of flexibility when planning and implementing a network. The
slot can accept any SFP-type fiber module and these modules are designed for transmitting
over distances of either 550m (multi-mode), 10km, 30km, 50km, 70km or 110km
(single-mode)—and the slot supports SFP modules for WDM single-fiber transmissions. This
means that you can easily change the transmission mode and distance of the switch by
simply pulling out the SFP module and plugging in a different module. The SFP modules are
hot-swappable and plug-and-play.
SFP with DMI (Digital Monitoring Interface) function
The ComNet™ SFP supports a digital monitoring interface (DMI) function that allows
real-time access to device operating parameters, and includes optional digital features such
2
as soft control and monitoring of SFP I/O signals. In addition, you can set up the action of
alarms and warnings by ports to manage your devices.
High-Speed Transmission
The CNGE8FX4TX4MS includes a switch controller that can automatically sense transmission
speeds (10/100/1000 Mbps). The RJ45 interface can also be auto-detected, so MDI or MDI-X
is automatically selected and a crossover cable is not required. All Ethernet ports have
memory buffers that support the store-and-forward mechanism. This assures that data is
properly transmitted.
Dual Power Input
The redundant power input design of the CNGE8FX4TX4MS is with power reserve protection
to prevent the switch from being damaged by using the wrong power source. When one of
power input has failed, the P-Fail LED will turn on and send an alarm through a relay output to
notify the user.
Flexible Mounting
The CNGE8FX4TX4MS is a compact size and can be mounted on a DIN-rail or panel. It can
be used in any location where space is scarce.
Advanced Protection
The power line of the CNGE8FX4TX4MS supports up to 3,000 V
DC
EFT protection, which
protects the switch from unregulated voltage and provides greater reliability. This high
voltage protection feature protects all the ports and makes the CNGE8FX4TX4MS suitable for
us in harsh industrial environments
Wide Operating Temperature
The ambient operating temperature of the CNGE8FX4TX4MS is between -40
o
C ~ 75
o
C.
3
Easy Troubleshooting
LED indicators make troubleshooting quick and easy. Each 10/100/1000 Base-TX port has 2
LEDs that display the link status and transmission speed. The three power indicators: PWR1,
PWR2 and P-Fail assist in diagnosing any problems quickly.
4
ComNet CNGE8FX4TX4MS Features
Provides four 10/100/1000Base-T Mbps Ethernet ports
Provides four SFP (mini-GBIC) port (supports 100/1000 Mbps Dual Mode)
SFPs support DMI function
Supports full/half duplex flow control
Supports auto-negotiation
Supports MDI/MDI-X auto-crossover
Supports Packet Buffer up to 1Mb
Supports MAC Address up to 8Kb
Supports surge (EFT) protection 3,000 V
DC
Supports 6,000 V
DC
Ethernet ESD protection
Power Supply
Wide-range Redundant Power Design
Reverse Power Polarity Protection
Current Overload Protection
Case/Installation
IP-30 Protection
DIN Rail and Wall Mount Design
Spanning Tree
Support IEEE802.1d Spanning Tree
Support IEEE802.1w Rapid Spanning Tree
VLAN
Port Based VLAN
Support 802.1 Q Tag VLAN
GVRP
X-Ring
X-Ring, Dual Homing and Couple Ring Topology
Provide redundant backup feature with a recovery time below 20ms
Port Trunk with LACP
QoS (Quality of Service)
Support IEEE 802.1p Class of Service
Per port provides 4 priority queues
Port Base, Tag Base and Type of Service Priority
5
Bandwidth Control
Ingress Packet Filter and Egress Rate Limit
Broadcast/Multicast Packet Filter Control
Port Mirror: Monitor traffic in switched networks.
TX Packet only
RX Packet only
Both of TX and RX Packet
System Event Log
System Log Server/Client
SMTP e-mail Alert
Relay Alarm Output System Events
Security
Port Security: MAC address entries/filter
IP Security: IP address security management to prevent unauthorized intruder
Login Security: IEEE802.1X/RADIUS
SNMP Trap
Device cold start
Power status
Authentication failure
X-Ring topology changed
Port Link up/Link down
IGMP with Query mode for Multi Media Application
TFTP Firmware Update and System Configure Restore and Backup
Ambient operating temperature range -40
o
C ~ 75
o
C
6
CNGE8FX4TX4MS Technical Specifications
Communication
Compatibility
IEEE 802.3, 802.3u, 802.3ab
IEEE 802.3x, 802.3z, 802.3ad
IEEE 802.1d, 802.1p, 802.1Q, 802.1x
IEEE 802.1ab
LAN
10/100/1000Base-T, 1000Base-X
Transmission Speed
Up to 1000 Mbps
Interface
Connectors
4 x RJ45 (4-port 10/100/1000TX)
4 x 100/1000 SFP sockets
6-pin removable screw terminal (Power & Relay)
LED Indicators
Unit: Power1, Power2, P-Fail, R-Master
Ethernet port: Link/Active, 1000M
SFP: Link/Active
Network Management
Configuration
Web browser, Telnet, Serial Console, Windows
Utility, TFTP, SNMP v1/v2c/v3, Port Speed/Duplex
Configuration
VLAN
IEEE 802.1Q, GVRP, Port-based, VLAN
Redundancy
X-Ring (Recovery time < 20ms), Dual Homing,
Couple Ring, 802.1w/d RSTP/STP
Security
IP Access security, post security, DHCP Server,
Port and IP Binding, 802.1X Port Access Control
Traffic Control
IGMP Snooping/Query for multicast group
management Port Trunking, Static/802.3ad LACP
Rate limit and storm control
IEEE 802.1p QoS Cos/TOS/DSCP priority queuing
IEEE 802.3x flow control
7
Diagnostics
Port Mirroring, Real-time traffic statistic, MAC
Address Table, SNTP, Syslog, E-Mail Alert,
SNMP, Trap, RMON
Power
Power Consumption
13 Watts
Power Input
2 x Unregulated +12 ~ 48 V
DC
Fault Output
1 Relay Output
Mechanism
Dimensions (WxHxD)
59.6 x 152 x 105 mm
Enclosure
IP-30, Metal shell with solid mounting kits
Mounting
DIN-Rail, Wall Mount
Protection
ESD (Ethernet)
6,000 V
DC
Surge (EFT for power)
3,000 V
DC
Reverse Power Protection
Yes
Current Overload Protection
Yes
Environment
Operating Temperature Range
-40
o
C ~ 75
o
C
Operating Humidity Range
5% ~ 95% (non-condensing)
Storage Temperature
-40
o
C ~ 85
o
C
Storage Humidity
5% ~ 95% (non-condensing)
Certification
Safety
UL508, cUL
EMC
FCC Class A,
CE EN61000-6-2
CE EN61000-6-4
CE EN61000-4-2 (ESD)
CE EN61000-4-3 (RS)
CE EN61000-4-4 (EFT)
8
CE EN61000-4-5 (Surge)
CE EN61000-4-6 (CS)
CE EN61000-4-8 (Magnetic Field)
CE EN61000-4-11 (Voltage DIP)
CE EN61000-3-2 (Harmonics Current)
CE EN61000-3-3 (Voltage Fluctuation & Flickers)
Free Fall
IEC60068-2-32
Shock
IEC60068-2-27
Vibration
IEC60068-2-6
Packing List
1 x 4 10/100/1000T + 4 SFP Managed Switch
1 x RS232 Cable
1 x User Manual
2 x Wall Mounting Bracket and Screws
Safety Precaution
Attention:
IF DC voltage is supplied by an external circuit, please use
a protection device on the power supply input.
9
Hardware Description
In this section, we will introduce the CNGE8FX4TX4MS’s hardware spec, port, cabling
information, and wiring installation.
Front Panel
The Front Panel of the CNGE8FX4TX4MS is shown as follows:
Front Panel of the CNGE8FX4TX4MS Managed Switch
10
Top View
The top panel of the CNGE8FX4TX4MS is equipped with one terminal block connector for
two DC power inputs.
Top panel of the 4 10/100/1000T + 4 SFP Switch
Wiring the Power Inputs
Primary Secondary (Redundant)
Voltage Input Power Input
Insert the positive and negative wires into the V+ and V- contacts on the terminal block
connector.
11
Tighten the wire-clamp screws to prevent the wires from loosening.
Note
The wire gauge for the terminal block should be in the range between 12~ 20 AWG.
12
LED Indicators
There are LEDs that display the power status and network status and are located on the front
panel of the CNGE8FX4TX4MS switch. Each has its own specific meaning as noted below.
Color
Description
On
The switch is the master of the X-ring group
Green
Off
The switch is not the master of the X-ring
group
On
Power input 1 is active
Green
Off
Power input 1 is inactive
On
Power input 2 is active
Green
Off
Power input 2 is inactive
On
Power input 1 or 2 is inactive or port link
down (depends on Fault Relay Alarm
configuration)
Red
Off
Power input 1 and 2 are both functional, or
no power inputs
On
SFP port is linking
Blinking
Transmitting or receiving data
Green
Off
Not connected to network
On
Connected to network
Blinking
Data is being transmitted or received
Green
Off
Not connected to network
On
Connected to network at speed of
1000Mbps
Green
Off
Connected to network at speed of
10/100Mbps
LED indicators of the CNGE8FX4TX4MS Switch
13
Ports
RJ45 ports (Auto MDI/MDIX): The RJ45 ports are auto-sensing for 10Base-T, 100Base-TX
or 1000Base-T device connections. Auto MDI/MDIX means that you can connect to another
switch or workstation without changing straight through or crossover cabling. See figures
below for straight-through and crossover cable schematic.
RJ45 Pin Assignments
Pin Number
Assignment
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Note
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
All ports on this managed switch support automatic MDI/MDI-X operation. You can use
straight-through cables (See Figure below) for all network connections to PCs or servers, or
to other switches or hubs. In a straight-through cable, pins 1, 2, 3, and 6, at one end of the
cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The
10BASE-T/100BASE-TX/1000BASE-T MDI and MDI-X port pin outs are as presented below.
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
14
Straight Through Cable Schematic
Cross Over Cable Schematic
Cabling
Use the four twisted-pair, Category 5e or above cabling for all RJ45 port connections. The
length of cable between the switch and the link partner (switch, hub, workstation, etc.) must
be less than 100 meters (328 ft.) long.
The small form-factor pluggable (SFP) devices that are the compact optical transceivers used
for optical communication for both telecommunication and data communication applications.
To connect the transceiver and LC cable, please follow the steps shown:
1. Insert the SFP device into the SFP receptacle. Notice that the triangle mark is the
bottom of the module.
SFP Receptacle
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115

Comnet CNGE8FX4TX4MS User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI